1.
Morphologie ; 101(332): 19-32, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27423215

RESUMEN

INTRODUCTION: Transcathether heart valve replacement has gained considerable acceptance during the last decades. It is now part of the armamentarium for aortic valve replacement. The procedure proved to be highly efficient. However the issues of the blood compatibility and tissue durability were not raised and the adverse events were probably under-reported, according to observations of thrombosis after deployment. MATERIAL AND METHOD: Bovine pericardium leaflets were sewn inside a 26mm diameter stainless steel stent to manufacture these valves (one control and two experimental). The correlation between the trauma and the acute thombogenicity of bovine pericardium leaflets, after crimping and ballooning, was investigated via an in vitro blood flow with labeled platelets. These leaflets were processed for histology: scanning electron microscopy, light microscopy, and transmission electron microscopy. RESULTS: The control specimens showed a regular pericardium structure with some blood cells deposited on the collagen fibrous surface (inflow) and scarce blood cells deposited on the serous surface (outflow). After crimping and ballooning, the structure of the pericardium was severely injured, eventually with delaminations and ruptures. The blood cell uptake was considerably increased compared to the control. CONCLUSION: It would therefore be appropriate to pay more attention to the design of the valves. Specifically, the incorporation of a buffer tissue or fabric between the pericardium and the metallic stent is suggested. The issue of ballooning deserves detailed and in depth investigation regarding the lifetime of the device.


Asunto(s)
Valvuloplastia con Balón/instrumentación , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Diseño de Prótesis/efectos adversos , Trombosis/etiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Animales , Válvula Aórtica/cirugía , Circulación Sanguínea , Bovinos , Voluntarios Sanos , Humanos , Microscopía Electrónica de Rastreo , Microscopía Electrónica de Transmisión , Pericardio/patología , Pericardio/cirugía , Pericardio/ultraestructura , Stents/efectos adversos , Propiedades de Superficie , Trombosis/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA