Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
Cell ; 185(6): 995-1007.e18, 2022 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-35303429

RESUMEN

Several ebolaviruses cause outbreaks of severe disease. Vaccines and monoclonal antibody cocktails are available to treat Ebola virus (EBOV) infections, but not Sudan virus (SUDV) or other ebolaviruses. Current cocktails contain antibodies that cross-react with the secreted soluble glycoprotein (sGP) that absorbs virus-neutralizing antibodies. By sorting memory B cells from EBOV infection survivors, we isolated two broadly reactive anti-GP monoclonal antibodies, 1C3 and 1C11, that potently neutralize, protect rodents from disease, and lack sGP cross-reactivity. Both antibodies recognize quaternary epitopes in trimeric ebolavirus GP. 1C11 bridges adjacent protomers via the fusion loop. 1C3 has a tripartite epitope in the center of the trimer apex. One 1C3 antigen-binding fragment anchors simultaneously to the three receptor-binding sites in the GP trimer, and separate 1C3 paratope regions interact differently with identical residues on the three protomers. A cocktail of both antibodies completely protected nonhuman primates from EBOV and SUDV infections, indicating their potential clinical value.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Antivirales , Ebolavirus , Fiebre Hemorrágica Ebola , Animales , Epítopos , Glicoproteínas/química , Subunidades de Proteína
2.
Cell ; 177(6): 1566-1582.e17, 2019 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-31104840

RESUMEN

Ebola virus (EBOV) remains a public health threat. We performed a longitudinal study of B cell responses to EBOV in four survivors of the 2014 West African outbreak. Infection induced lasting EBOV-specific immunoglobulin G (IgG) antibodies, but their subclass composition changed over time, with IgG1 persisting, IgG3 rapidly declining, and IgG4 appearing late. Striking changes occurred in the immunoglobulin repertoire, with massive recruitment of naive B cells that subsequently underwent hypermutation. We characterized a large panel of EBOV glycoprotein-specific monoclonal antibodies (mAbs). Only a small subset of mAbs that bound glycoprotein by ELISA recognized cell-surface glycoprotein. However, this subset contained all neutralizing mAbs. Several mAbs protected against EBOV disease in animals, including one mAb that targeted an epitope under evolutionary selection during the 2014 outbreak. Convergent antibody evolution was seen across multiple donors, particularly among VH3-13 neutralizing antibodies specific for the GP1 core. Our study provides a benchmark for assessing EBOV vaccine-induced immunity.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Linfocitos B/fisiología , Fiebre Hemorrágica Ebola/inmunología , Adulto , Secuencia de Aminoácidos/genética , Animales , Anticuerpos Monoclonales/aislamiento & purificación , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , Linfocitos B/metabolismo , Chlorocebus aethiops , Vacunas contra el Virus del Ébola/inmunología , Ebolavirus/genética , Ebolavirus/metabolismo , Ebolavirus/patogenicidad , Epítopos/sangre , Femenino , Glicoproteínas/genética , Fiebre Hemorrágica Ebola/metabolismo , Fiebre Hemorrágica Ebola/virología , Humanos , Inmunoglobulina G/inmunología , Células Jurkat , Estudios Longitudinales , Masculino , Ratones , Ratones Endogámicos BALB C , Sobrevivientes , Células Vero , Proteínas del Envoltorio Viral/genética
3.
Nature ; 586(7830): 509-515, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32967005

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the aetiological agent of coronavirus disease 2019 (COVID-19), an emerging respiratory infection caused by the introduction of a novel coronavirus into humans late in 2019 (first detected in Hubei province, China). As of 18 September 2020, SARS-CoV-2 has spread to 215 countries, has infected more than 30 million people and has caused more than 950,000 deaths. As humans do not have pre-existing immunity to SARS-CoV-2, there is an urgent need to develop therapeutic agents and vaccines to mitigate the current pandemic and to prevent the re-emergence of COVID-19. In February 2020, the World Health Organization (WHO) assembled an international panel to develop animal models for COVID-19 to accelerate the testing of vaccines and therapeutic agents. Here we summarize the findings to date and provides relevant information for preclinical testing of vaccine candidates and therapeutic agents for COVID-19.


Asunto(s)
Infecciones por Coronavirus/tratamiento farmacológico , Infecciones por Coronavirus/prevención & control , Modelos Animales de Enfermedad , Pandemias/prevención & control , Neumonía Viral/tratamiento farmacológico , Neumonía Viral/prevención & control , Animales , Betacoronavirus/efectos de los fármacos , Betacoronavirus/inmunología , COVID-19 , Vacunas contra la COVID-19 , Infecciones por Coronavirus/inmunología , Hurones/virología , Humanos , Mesocricetus/virología , Ratones , Neumonía Viral/inmunología , Primates/virología , SARS-CoV-2 , Vacunas Virales/inmunología
4.
N Engl J Med ; 387(14): 1292-1302, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36036522

RESUMEN

BACKGROUND: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS: A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS: In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).


Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Humanos , Estudios Prospectivos , Resultado del Tratamiento
5.
N Engl J Med ; 384(13): 1240-1247, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33789012

RESUMEN

During the 2018-2020 Ebola virus disease (EVD) outbreak in North Kivu province in the Democratic Republic of Congo, EVD was diagnosed in a patient who had received the recombinant vesicular stomatitis virus-based vaccine expressing a ZEBOV glycoprotein (rVSV-ZEBOV) (Merck). His treatment included an Ebola virus (EBOV)-specific monoclonal antibody (mAb114), and he recovered within 14 days. However, 6 months later, he presented again with severe EVD-like illness and EBOV viremia, and he died. We initiated epidemiologic and genomic investigations that showed that the patient had had a relapse of acute EVD that led to a transmission chain resulting in 91 cases across six health zones over 4 months. (Funded by the Bill and Melinda Gates Foundation and others.).


Asunto(s)
Ebolavirus/genética , Fiebre Hemorrágica Ebola/transmisión , Adulto , Teorema de Bayes , República Democrática del Congo/epidemiología , Vacunas contra el Virus del Ébola/inmunología , Ebolavirus/aislamiento & purificación , Resultado Fatal , Genoma Viral , Fiebre Hemorrágica Ebola/diagnóstico , Fiebre Hemorrágica Ebola/epidemiología , Fiebre Hemorrágica Ebola/terapia , Humanos , Masculino , Mutación , Filogenia , ARN Viral/sangre , Recurrencia
6.
Am J Pathol ; 193(12): 2031-2046, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37689386

RESUMEN

The pathophysiology of long-recognized hematologic abnormalities in Ebolavirus (EBOV) disease (EVD) is unknown. From limited human sampling (of peripheral blood), it has been postulated that emergency hematopoiesis plays a role in severe EVD, but the systematic characterization of the bone marrow (BM) has not occurred in human disease or in nonhuman primate models. In a lethal rhesus macaque model of EVD, 18 sternal BM samples exposed to the Kikwit strain of EBOV were compared to those from uninfected controls (n = 3). Immunohistochemistry, RNAscope in situ hybridization, transmission electron microscopy, and confocal microscopy showed that EBOV infects BM monocytes/macrophages and megakaryocytes. EBOV exposure was associated with severe BM hypocellularity, including depletion of myeloid, erythroid, and megakaryocyte hematopoietic cells. These depletions were negatively correlated with cell proliferation (Ki67 expression) and were not associated with BM apoptosis during disease progression. In EBOV-infected rhesus macaques with terminal disease, BM showed marked hemophagocytosis, megakaryocyte emperipolesis, and the release of immature hematopoietic cells into the sinusoids. Collectively, these data demonstrate not only direct EBOV infection of BM monocytes/macrophages and megakaryocytes but also that disease progression is associated with hematopoietic failure, notably in peripheral cytopenia. These findings inform current pathophysiologic unknowns and suggest a crucial role for BM dysfunction and/or failure, including emergency hematopoiesis, as part of the natural history of severe human disease.


Asunto(s)
Ebolavirus , Fiebre Hemorrágica Ebola , Animales , Humanos , Ebolavirus/fisiología , Macaca mulatta , Médula Ósea , Progresión de la Enfermedad
7.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38047465

RESUMEN

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Asunto(s)
Desfibriladores Implantables , Humanos , Calidad de Vida , Estudios Prospectivos , Encuestas y Cuestionarios , Medición de Resultados Informados por el Paciente
8.
J Infect Dis ; 228(Suppl 4): S322-S336, 2023 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-37788501

RESUMEN

The mass production of the graphics processing unit and the coronavirus disease 2019 (COVID-19) pandemic have provided the means and the motivation, respectively, for rapid developments in artificial intelligence (AI) and medical imaging techniques. This has led to new opportunities to improve patient care but also new challenges that must be overcome before these techniques are put into practice. In particular, early AI models reported high performances but failed to perform as well on new data. However, these mistakes motivated further innovation focused on developing models that were not only accurate but also stable and generalizable to new data. The recent developments in AI in response to the COVID-19 pandemic will reap future dividends by facilitating, expediting, and informing other medical AI applications and educating the broad academic audience on the topic. Furthermore, AI research on imaging animal models of infectious diseases offers a unique problem space that can fill in evidence gaps that exist in clinical infectious disease research. Here, we aim to provide a focused assessment of the AI techniques leveraged in the infectious disease imaging research space, highlight the unique challenges, and discuss burgeoning solutions.


Asunto(s)
COVID-19 , Enfermedades Transmisibles , Humanos , Inteligencia Artificial , Pandemias , Diagnóstico por Imagen/métodos , Enfermedades Transmisibles/diagnóstico por imagen
9.
J Infect Dis ; 228(Suppl 7): S474-S478, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37596837

RESUMEN

Although there are now approved treatments and vaccines for Ebola virus disease, the case fatality rate remains unacceptably high even when patients are treated with the newly approved therapeutics. Furthermore, these countermeasures are not expected to be effective against disease caused by other filoviruses. A meeting of subject-matter experts was held during the 10th International Filovirus Symposium to discuss strategies to address these gaps. Several investigational therapeutics, vaccine candidates, and combination strategies were presented. The greatest challenge was identified to be the implementation of well-designed clinical trials of safety and efficacy during filovirus disease outbreaks. Preparing for this will require agreed-upon common protocols for trials intended to bridge multiple outbreaks across all at-risk countries. A multinational research consortium including at-risk countries would be an ideal mechanism to negotiate agreement on protocol design and coordinate preparation. Discussion participants recommended a follow-up meeting be held in Africa to establish such a consortium.


Asunto(s)
Ebolavirus , Infecciones por Filoviridae , Filoviridae , Fiebre Hemorrágica Ebola , Humanos , Fiebre Hemorrágica Ebola/prevención & control , Fiebre Hemorrágica Ebola/epidemiología , Brotes de Enfermedades/prevención & control , África
10.
J Infect Dis ; 228(4): 371-382, 2023 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-37279544

RESUMEN

BACKGROUND: Ebola virus (EBOV) disease (EVD) is one of the most severe and fatal viral hemorrhagic fevers and appears to mimic many clinical and laboratory manifestations of hemophagocytic lymphohistiocytosis syndrome (HLS), also known as macrophage activation syndrome. However, a clear association is yet to be firmly established for effective host-targeted, immunomodulatory therapeutic approaches to improve outcomes in patients with severe EVD. METHODS: Twenty-four rhesus monkeys were exposed intramuscularly to the EBOV Kikwit isolate and euthanized at prescheduled time points or when they reached the end-stage disease criteria. Three additional monkeys were mock-exposed and used as uninfected controls. RESULTS: EBOV-exposed monkeys presented with clinicopathologic features of HLS, including fever, multiple organomegaly, pancytopenia, hemophagocytosis, hyperfibrinogenemia with disseminated intravascular coagulation, hypertriglyceridemia, hypercytokinemia, increased concentrations of soluble CD163 and CD25 in serum, and the loss of activated natural killer cells. CONCLUSIONS: Our data suggest that EVD in the rhesus macaque model mimics pathophysiologic features of HLS/macrophage activation syndrome. Hence, regulating inflammation and immune function might provide an effective treatment for controlling the pathogenesis of acute EVD.


Asunto(s)
Ebolavirus , Fiebre Hemorrágica Ebola , Linfohistiocitosis Hemofagocítica , Síndrome de Activación Macrofágica , Animales , Síndrome de Activación Macrofágica/terapia , Macaca mulatta
11.
Heart Lung Circ ; 32(2): 261-268, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36372717

RESUMEN

BACKGROUND: A cardiac implantable electronic device (CIED) survey was undertaken in Australia and New Zealand for calendar year 2021. The survey involved pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). The survey was conducted on the 50th anniversary of the first survey for both Australia and New Zealand in 1972; that initial survey being conducted by two of the current authors. RESULTS AND CONCLUSIONS: For 2021, there were 19,410 PMs (17,971 in 2017) sold in Australia for new implants and 2,282 (1,811 in 2017) sold in New Zealand. The number of new PM implants per million population was 755 for Australia (745 in 2017) and 446 for New Zealand (384 in 2017). Unlike previous recent surveys, the percentage of PM replacements compared to total sales in both Australia and New Zealand rose. Pulse generator types implanted were predominantly dual chamber; Australia 77% (73% in 2017) and New Zealand 70% (68% in 2017). There were 1,509 biventricular PMs implanted in Australia (1,247 in 2017) and 172 in New Zealand (118 in 2017). Transvenous pacing leads were >90% active fixation in the atrium and ventricle. There was an increase in ICD usage with Australia 4,519 new implants (4,212 in 2017) and New Zealand 449 (396 in 2017). New ICD implants per million population were 187 for Australia (175 in 2017) and 88 for New Zealand (90 in 2017). For the first time the survey included implantable event monitors with 6,933 being implanted in Australia. However, for proprietary reasons, survey figures for subcutaneous implantable defibrillators, leadless pacemakers and conduction system pacing have not been included. Both Australia and New Zealand have high PM and ICD implant numbers compared to the rest of the Asia Pacific region.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Nueva Zelanda/epidemiología , Aniversarios y Eventos Especiales , Australia/epidemiología , Encuestas y Cuestionarios
12.
N Engl J Med ; 381(24): 2293-2303, 2019 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-31774950

RESUMEN

BACKGROUND: Although several experimental therapeutics for Ebola virus disease (EVD) have been developed, the safety and efficacy of the most promising therapies need to be assessed in the context of a randomized, controlled trial. METHODS: We conducted a trial of four investigational therapies for EVD in the Democratic Republic of Congo, where an outbreak began in August 2018. Patients of any age who had a positive result for Ebola virus RNA on reverse-transcriptase-polymerase-chain-reaction assay were enrolled. All patients received standard care and were randomly assigned in a 1:1:1:1 ratio to intravenous administration of the triple monoclonal antibody ZMapp (the control group), the antiviral agent remdesivir, the single monoclonal antibody MAb114, or the triple monoclonal antibody REGN-EB3. The REGN-EB3 group was added in a later version of the protocol, so data from these patients were compared with those of patients in the ZMapp group who were enrolled at or after the time the REGN-EB3 group was added (the ZMapp subgroup). The primary end point was death at 28 days. RESULTS: A total of 681 patients were enrolled from November 20, 2018, to August 9, 2019, at which time the data and safety monitoring board recommended that patients be assigned only to the MAb114 and REGN-EB3 groups for the remainder of the trial; the recommendation was based on the results of an interim analysis that showed superiority of these groups to ZMapp and remdesivir with respect to mortality. At 28 days, death had occurred in 61 of 174 patients (35.1%) in the MAb114 group, as compared with 84 of 169 (49.7%) in the ZMapp group (P = 0.007), and in 52 of 155 (33.5%) in the REGN-EB3 group, as compared with 79 of 154 (51.3%) in the ZMapp subgroup (P = 0.002). A shorter duration of symptoms before admission and lower baseline values for viral load and for serum creatinine and aminotransferase levels each correlated with improved survival. Four serious adverse events were judged to be potentially related to the trial drugs. CONCLUSIONS: Both MAb114 and REGN-EB3 were superior to ZMapp in reducing mortality from EVD. Scientifically and ethically sound clinical research can be conducted during disease outbreaks and can help inform the outbreak response. (Funded by the National Institute of Allergy and Infectious Diseases and others; PALM ClinicalTrials.gov number, NCT03719586.).


Asunto(s)
Alanina/análogos & derivados , Anticuerpos Monoclonales/uso terapéutico , Antivirales/uso terapéutico , Fiebre Hemorrágica Ebola/tratamiento farmacológico , Ribonucleótidos/uso terapéutico , Adenosina Monofosfato/análogos & derivados , Adolescente , Adulto , Alanina/efectos adversos , Alanina/uso terapéutico , Anticuerpos Monoclonales/efectos adversos , Antivirales/efectos adversos , Niño , Preescolar , República Democrática del Congo/epidemiología , Brotes de Enfermedades , Ebolavirus/genética , Femenino , Fiebre Hemorrágica Ebola/mortalidad , Humanos , Lactante , Recién Nacido , Infusiones Intravenosas , Masculino , ARN Viral/sangre , Ribonucleótidos/efectos adversos , Método Simple Ciego , Adulto Joven
13.
J Cardiovasc Electrophysiol ; 33(6): 1085-1095, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35478368

RESUMEN

INTRODUCTION: The extravascular implantable cardioverter-defibrillato (EV ICD) system with substernal lead placement is a novel nontransvenous alternative to current commercially available ICD systems. The EV ICD provides defibrillation and pacing therapies without the potential long-term complications of endovascular lead placement but requires a new procedure for implantation with a safety profile under evaluation. METHODS: This paper summarizes the development of the EV ICD, including the preclinical and clinical evaluations that have contributed to the system and procedural refinements to date. RESULTS: Extensive preclinical research evaluations and four human clinical studies with >140 combined acute and chronic implants have enabled the development and refinement of the EV ICD system, currently in worldwide pivotal study. CONCLUSION: The EV ICD may represent a clinically valuable solution in protecting patients from sudden cardiac death while avoiding the long-term consequences of transvenous hardware. The EV ICD offers advantages over transvenous and subcutaneous systems by avoiding placement in the heart and vasculature; relative to subcutaneous systems, EV ICD requires less energy for defibrillation, enabling a smaller device, and provides pacing features such as antitachycardia and asystole pacing in a single system.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Paro Cardíaco/diagnóstico , Paro Cardíaco/etiología , Paro Cardíaco/terapia , Humanos
14.
Europace ; 24(5): 762-773, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-34662385

RESUMEN

AIMS: The aim of this study is to provide a thorough, quantified assessment of the substernal space as the site of extravascular implantable cardioverter-defibrillator (ICD) lead placement using computed tomography (CT) scans and summarizing adverse events and defibrillation efficacy across anatomical findings. Subcutaneous ICDs are an alternative to transvenous defibrillators but have limitations related to ICD lead distance from the heart. An alternative extravascular system with substernal lead placement has the potential to provide defibrillation at lower energy and pacing therapies from a single device. METHODS AND RESULTS: A multi-centre, non-randomized, retrospective analysis of 45 patient CT scans quantitatively and qualitatively assessing bony, cardiac, vascular, and other organ structures from two human clinical studies with substernal lead placement. Univariate logistic regression was used to evaluate 15 anatomical parameters for impact on defibrillation outcome and adjusted for multiple comparisons. Adverse events were summarized. Substernal implantation was attempted or completed in 45 patients. Defibrillation testing was successful in 37 of 41 subjects (90%) using ≥10 J safety margin. There were two intra-procedural adverse events in one patient, including reaction to anaesthesia and an episode of transient atrial fibrillation during ventricular fibrillation induction. Anatomical factors associated with defibrillation failure included large rib cage width, myocardium extending very posteriorly, and a low heart position in the chest (P-values <0.05), though not significant adjusting for multiple comparisons. CONCLUSION: Retrospective analysis demonstrates the ability to implant within the substernal space with low intra-procedural adverse events and high defibrillation efficacy despite a wide range of anatomical variability.


Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Humanos , Estudios Retrospectivos , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia
15.
Am J Pathol ; 190(9): 1867-1880, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32479821

RESUMEN

The most commonly reported symptom of post-Ebola virus disease syndrome in survivors is arthralgia, yet involvement of the joints in acute or convalescent Ebola virus infection is not well characterized in human patients or animal models. Through immunohistochemistry, we found that the lining synovial intima of the stifle (knee) is a target for acute infection by Ebola virus/Kikwit, Ebola virus/Makona-C05, and Marburg virus/Angola in the rhesus macaque model. Furthermore, histologic analysis, immunohistochemistry, RNAscope in situ hybridization, and transmission electron microscopy showed that synoviocytes of the stifle, shoulder, and hip are a target for mouse-adapted Ebola virus/Yambuku-Mayinga infection during acute disease in rhesus macaques. A time course of infection study with Ebola virus/Kikwit found that the large joint synovium became immunopositive beginning on postinfection day 6. In total, the synovium of 28 of 30 rhesus macaques with terminal filovirus disease had evidence of infection (64 of 96 joints examined). On the basis of immunofluorescence, infected cell types included CD68+ type A (macrophage-like) synoviocytes and CD44+ type B (fibroblast-like) synoviocytes. Cultured primary human fibroblast-like synoviocytes were permissive to infection with Ebola and Marburg viruses in vitro. Because synovial joints include immune privileged sites, these findings are significant for future investigations of filovirus pathogenesis and persistence as well as arthralgias in acute and convalescent filovirus disease.


Asunto(s)
Infecciones por Filoviridae/virología , Sinoviocitos/virología , Animales , Células Cultivadas , Filoviridae , Humanos , Macaca mulatta
16.
J Cardiovasc Electrophysiol ; 32(9): 2371-2378, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34322918

RESUMEN

BACKGROUND: Transvenous implantable cardioverter defibrillators (TV ICD) provide life-saving therapy for millions of patients worldwide. However, they are susceptible to several potential short- and long- term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD system's novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs. STUDY DESIGN: The EV ICD pivotal study is a prospective, multicenter, single-arm, nonrandomized, premarket clinical study designed to examine the safety and acute efficacy of the system. This study will enroll up to 400 patients with a Class I or IIa indication for implantation of an ICD. Implanted subjects will be followed up to approximately 3.5 years, depending on when the patient is enrolled. OBJECTIVE: The clinical trial is designed to demonstrate safety and effectiveness of the EV ICD system in human use. The safety endpoint is freedom from major complications, while the efficacy endpoint is defibrillation success. Both endpoints will be assessed against prespecified criteria. Additionally, this study will evaluate antitachycardia pacing performance, electrical performance, extracardiac pacing sensation, asystole pacing, appropriate and inappropriate shocks, as well as a summary of adverse events. CONCLUSION: The EV ICD pivotal study is designed to provide clear evidence addressing the safety and efficacy performance of the EV ICD System.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Desfibriladores Implantables/efectos adversos , Humanos , Estudios Prospectivos , Resultado del Tratamiento
17.
Arch Virol ; 166(12): 3513-3566, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34463877

RESUMEN

In March 2021, following the annual International Committee on Taxonomy of Viruses (ICTV) ratification vote on newly proposed taxa, the phylum Negarnaviricota was amended and emended. The phylum was expanded by four families (Aliusviridae, Crepuscuviridae, Myriaviridae, and Natareviridae), three subfamilies (Alpharhabdovirinae, Betarhabdovirinae, and Gammarhabdovirinae), 42 genera, and 200 species. Thirty-nine species were renamed and/or moved and seven species were abolished. This article presents the updated taxonomy of Negarnaviricota as now accepted by the ICTV.


Asunto(s)
Mononegavirales , Virus , Humanos
18.
Emerg Infect Dis ; 26(7): 1553-1556, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32568043

RESUMEN

A 46-year-old patient with previously documented Ebola virus persistence in his ocular fluid, associated with severe panuveitis, developed a visually significant cataract. A multidisciplinary approach was taken to prevent and control infection. Ebola virus persistence was assessed before and during the operation to provide safe, vision-restorative phacoemulsification surgery.


Asunto(s)
Catarata , Ebolavirus , Fiebre Hemorrágica Ebola , Ojo , Humanos , Persona de Mediana Edad , Sobrevivientes
19.
Arch Virol ; 165(12): 3023-3072, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32888050

RESUMEN

In March 2020, following the annual International Committee on Taxonomy of Viruses (ICTV) ratification vote on newly proposed taxa, the phylum Negarnaviricota was amended and emended. At the genus rank, 20 new genera were added, two were deleted, one was moved, and three were renamed. At the species rank, 160 species were added, four were deleted, ten were moved and renamed, and 30 species were renamed. This article presents the updated taxonomy of Negarnaviricota as now accepted by the ICTV.


Asunto(s)
Mononegavirales/clasificación , Terminología como Asunto
20.
Intern Med J ; 50(8): 1000-1003, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32881225

RESUMEN

An increase in coronavirus disease (COVID-19) infections prompted Level 4 lockdown throughout New Zealand from 25 March 2020. We have investigated trends in coronary and electrophysiology (EP) procedures before and during this lockdown. The number of acute procedures for ST elevation myocardial infarction remained stable. In contrast, the number of in-patient angiograms and percutaneous intervention procedures fell by 53% compared with the previous 4 weeks in 2020 and by 56% compared with the corresponding period in 2019. Further study is required to determine the reasons for these trends.


Asunto(s)
Servicio de Cardiología en Hospital , Infecciones por Coronavirus , Control de Infecciones/estadística & datos numéricos , Pandemias , Intervención Coronaria Percutánea , Neumonía Viral , Infarto del Miocardio con Elevación del ST , Betacoronavirus , COVID-19 , Electrofisiología Cardíaca/métodos , Electrofisiología Cardíaca/tendencias , Servicio de Cardiología en Hospital/organización & administración , Servicio de Cardiología en Hospital/estadística & datos numéricos , Angiografía Coronaria/estadística & datos numéricos , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/prevención & control , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Control de Infecciones/métodos , Control de Infecciones/organización & administración , Masculino , Persona de Mediana Edad , Nueva Zelanda/epidemiología , Pandemias/prevención & control , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricos , Neumonía Viral/epidemiología , Neumonía Viral/prevención & control , SARS-CoV-2 , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/terapia , Carga de Trabajo/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA