Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Appl Clin Med Phys ; 20(2): 63-70, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30628154

RESUMEN

In-phantom and in-vivo three dimensional conformal radiation therapy (3DCRT) and volumetric modulated arc therapy (VMAT) skin doses, measured with and without bolus in a female anthropomorphic phantom RANDO and in patients, were compared against treatment planning system calculated values. A thorough characterization of the metal oxide semiconductor field effect transistor measurement system was performed prior to the measurements in phantoms and patients. Patients with clinical indication for postoperative external radiotherapy were selected. Skin dose showed higher values with 3DCRT technique compared with VMAT. The increase in skin dose due to the use of bolus was quantified. It was observed that, in the case of VMAT, the bolus effect on the skin dose was considerable when compared with 3DCRT. From the point of view of treatment time, bolus cost, and positioning reproducibility, the use of bolus in these situations can be optimized.


Asunto(s)
Neoplasias de la Mama/radioterapia , Fantasmas de Imagen , Radiometría/instrumentación , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos , Piel/efectos de la radiación , Femenino , Humanos , Órganos en Riesgo/efectos de la radiación , Pronóstico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Semiconductores
2.
J Appl Clin Med Phys ; 19(1): 250-258, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29193644

RESUMEN

PURPOSE: The purpose of this study was to evaluate the efficacy of needle holders in reducing staff hand exposure during biopsies guided by computed tomography fluoroscopy (CTF), through the analysis of data acquired during a detailed monitoring study, undertaken in parallel with an ongoing optimization process to reduce hand irradiation. METHODS: Hand monitoring was performed with 11 extremity detectors, two per finger (base and tip) and one on the back of the wrist, for the left (dominant) hand, during two series of biopsies with comparable characteristics. The first series (47 biopsies) were performed with only quick-check method (QC) and occasional side-handle (SH) manipulation of the needle. The second series (63 biopsies) were performed after introducing needle holders (NH) in the course of an optimization process. RESULTS: Choice of technique (QC, QC + NH, QC + SH) by the interventional radiologist (IR) was related to biopsy difficulty. Measured hand exposure was low (< 1 mSv) for all QC-only procedures, and for most of the QC + NH procedures. Occasional side-handle manipulation still occurred during challenging biopsies, so that 8% of biopsies in the second series accounted for ~70% of total fingertip dose (~90 mSv). The methodology used allowed a detailed insight into the dose reduction achievable with needle holders during real procedures, without the limitations of phantom measurements. CONCLUSIONS: Needle holders proved effective in reducing mean hand exposure during clinical procedures where real-time manipulation was necessary. Occasional side-handle manipulation was found to contribute disproportionately to hand exposure. This highlights the importance of individual hand monitoring during CTF guided procedures.


Asunto(s)
Fluoroscopía/instrumentación , Mano/efectos de la radiación , Exposición Profesional/análisis , Fantasmas de Imagen , Protección Radiológica/métodos , Radiografía Intervencional/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Biopsia con Aguja , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos
3.
Phys Med ; 32(11): 1397-1404, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27780674

RESUMEN

PURPOSE: To study the impact of shielding elements in the proximity of Intra-Operative Radiation Therapy (IORT) irradiation fields, and to generate graphical and quantitative information to assist radiation oncologists in the design of optimal shielding during pelvic and abdominal IORT. METHOD: An IORT system was modeled with BEAMnrc and EGS++ Monte Carlo codes. The model was validated in reference conditions by gamma index analysis against an experimental data set of different beam energies, applicator diameters, and bevel angles. The reliability of the IORT model was further tested considering shielding layers inserted in the radiation beam. Further simulations were performed introducing a bone-like layer embedded in the water phantom. The dose distributions were calculated as 3D dose maps. RESULTS: The analysis of the resulting 2D dose maps parallel to the clinical axis shows that the bevel angle of the applicator and its position relative to the shielding have a major influence on the dose distribution. When insufficient shielding is used, a hotspot nearby the shield appears near the surface. At greater depths, lateral scatter limits the dose reduction attainable with shielding, although the presence of bone-like structures in the phantom reduces the impact of this effect. CONCLUSIONS: Dose distributions in shielded IORT procedures are affected by distinct contributions when considering the regions near the shielding and deeper in tissue: insufficient shielding may lead to residual dose and hotspots, and the scattering effects may enlarge the beam in depth. These effects must be carefully considered when planning an IORT treatment with shielding.


Asunto(s)
Abdomen/efectos de la radiación , Abdomen/cirugía , Pelvis/efectos de la radiación , Pelvis/cirugía , Dosis de Radiación , Protección Radiológica/instrumentación , Radioterapia/instrumentación , Diseño de Equipo , Periodo Intraoperatorio , Modelos Biológicos , Método de Montecarlo , Huesos Pélvicos/efectos de la radiación , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA