Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Radiology ; 254(2): 460-8, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20093517

RESUMEN

PURPOSE: To determine the frequency of preoperative computed tomography (CT) in the evaluation of patients suspected of having appendicitis at one institution during the past 10 years and to determine whether changes in CT utilization were associated with changes in the negative appendectomy rate. MATERIALS AND METHODS: Institutional review board approval was obtained, and a waiver of informed consent was granted for this HIPAA-compliant study. A surgical database search yielded medical record numbers of 925 patients (526 [ 56.9%] men and 399 [43.1%] women; mean age, 38 years (range, 18-95 years]) who underwent urgent appendectomy between January 1998 and September 2007. Patients who were younger than 18 years of age at the time of surgery were excluded. CT, pathology, and surgery reports were reviewed. By using logistic regression, changes in the proportion of patients undergoing CT and in the proportion of patients undergoing each year appendectomy in which the appendix was healthy were evaluated. Subgroup analyses based on patient age ( 45 years) and sex also were performed. RESULTS: Prior to urgent appendectomy, 18.5% of patients underwent preoperative CT in 1998 compared with 93.2% of patients in 2007. The negative appendectomy rate for women 45 years of age and younger decreased from 42.9% in 1998% to 7.1% in 2007. However, the timing of the decline in negative appendectomy rates for women 45 years and younger could not be proved to be associated with the increase in CT use. There was no significant trend toward a lower negative appendectomy rate for men regardless of age or for women older than 45 years of age with increased use of preoperative CT. The shift from single-detector CT to multidetector CT and the use of decreasing section thickness also correlated with a reduction in false-positive diagnoses. CONCLUSION: Rising utilization of preoperative CT and advances in technology coincided with a decrease in the negative appendectomy rate for women 45 years and younger but not in men of any age or women older than 45 years.


Asunto(s)
Apendicectomía/estadística & datos numéricos , Apendicitis/diagnóstico por imagen , Apendicitis/cirugía , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios
2.
Radiology ; 251(3): 771-9, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19346514

RESUMEN

PURPOSE: To intraindividually compare a low tube voltage (80 kVp), high tube current computed tomographic (CT) technique with a standard CT protocol (140 kVp) in terms of image quality, radiation dose, and detection of malignant hypervascular liver tumors during the late hepatic arterial phase. MATERIALS AND METHODS: This prospective single-center HIPAA-compliant study had institutional review board approval, and written informed consent was obtained. Forty-eight patients (31 men, 17 women; age range, 35-77 years) with 60 malignant hypervascular liver tumors (mean diameter, 20.1 mm +/- 16.4 [standard deviation]) were enrolled. Pathologic proof of focal lesions was obtained with histopathologic analysis for 33 nodules and imaging follow-up after a minimum of 12 months for 27 nodules. Patients underwent dual-energy 64-section multi-detector row CT. By using vendor-specific software, two imaging protocols-140 kVp and 385 mA (protocol A) and 80 kVp and 675 mA (protocol B)-were compared during the late hepatic arterial phase of contrast enhancement. Paired t tests were used to compare tumor-to-liver contrast-to-noise ratio (CNR) for each lesion, mean image noise, and effective dose between the two data sets. Three readers qualitatively assessed the two data sets in a blinded and independent fashion. Lesion detection and characterization and reader confidence were recorded, as well as readers' subjective evaluations of image quality. Wilcoxon-Mann-Whitney statistical analysis was performed on this assessment. RESULTS: Image noise increased from 5.7 to 11.4 HU as the tube voltage decreased from 140 to 80 kVp (P < .0001), resulting in a significantly lower image quality score (4.0 vs 3.0, respectively) with protocol B according to all readers (P < .001). At the same time, protocol B yielded significantly higher CNR (8.2 vs 6.4) and lesion conspicuity scores (4.6 vs 4.1) than protocol A, along with a lower effective dose (5.1 vs 17.5 mSv) (P < .001 for all). CONCLUSION: By substantially increasing the tumor-to-liver CNR, a low tube voltage, high tube current CT technique improves the conspicuity of malignant hypervascular liver tumors during the late hepatic arterial phase while significantly reducing patient radiation dose.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Yopamidol , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Estadísticas no Paramétricas , Tomografía Computarizada por Rayos X/instrumentación
3.
AJR Am J Roentgenol ; 193(6): W515-22, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19933626

RESUMEN

OBJECTIVE: Bidimensional tumor measurements indicating a greater than 25% increase in tumor size are generally accepted as indicating tumor progression. We hypothesized that use of digital images and a homogeneous reader population would have lower interobserver variability than in previous studies. SUBJECTS AND METHODS: Eight board-certified radiologists measured tumor diameters in three planes in two consecutive MRI examinations of 22 patients with contrast-enhancing high-grade brain tumors. Products of tumor measurements were calculated, and determinations were made about tumor progression (> 25% increase in area). A variance components model was run on diameter products and the ratios of consecutive maximal diameter products. The variance components included patient examination effect, reader effect, and residual effect. RESULTS: Complete agreement was found among readers in 10 cases (45%), all indicating stable disease. In the other 12 cases, at least one reader considered progressive disease present. The variance components model showed variance due to readers was small, indicating only modest bias among readers. The residual variance component was large (0.038), indicating that repeated measurements on the same image likely are variable even for the same reader. This variability in measurement implies that repeated measurements by the typical reader have an inherent 14% false-positive rate in the diagnosis of progression of tumors that are stable. CONCLUSION: Our hypothesis was disproved. We found substantial interreader disagreement and indications that the very nature of the measurement method produces a high rate of false-positive readings of stable tumors. These findings should be considered in interpretation of images with this widely accepted criterion for brain tumor progression.


Asunto(s)
Neoplasias Encefálicas/patología , Imagen por Resonancia Magnética/métodos , Progresión de la Enfermedad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
4.
AJR Am J Roentgenol ; 193(6): 1568-75, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19933649

RESUMEN

OBJECTIVE: The purpose of our study was to evaluate the effect of varying volumes and rates of contrast material, use of a saline chaser, and cardiac output on aortic enhancement characteristics in MDCT angiography (MDCTA) using a physiologic phantom. MATERIALS AND METHODS: Volumes of 75, 100, and 125 mL of iopamidol, 370 mg I/mL, were administered at rates of 4, 6, and 8 mL/s. The effect of a saline chaser (50 mL of normal saline, 8 mL/s) was evaluated for each volume and rate combination. Normal, reduced (33% and 50%), and increased (25%) cardiac outputs were simulated. Peak aortic enhancement and duration of peak aortic enhancement were recorded. Analysis of variance models were run with these effects, and the estimated mean levels for the sets of factor combinations were determined. RESULTS: Lowering the volume of contrast material resulted in reduced peak enhancement (example, -56.2 HU [p < 0.0001] with 75 vs 125 mL) and reduced duration of 75% peak enhancement (example, -9.0 seconds [p < 0.0001] with 75 vs 125 mL). Increasing the rate resulted in increased peak enhancement (example, 104.5 HU [p < 0.0001] with a rate of 8 vs 4 mL/s) and decreased duration of 75% peak enhancement (example, -13.0 seconds [p < 0.001]). Use of a saline chaser resulted in increased peak enhancement, and this increase was inversely proportional to contrast material volume. Peak enhancement increased when reduced cardiac output was simulated. Peak enhancement decreased when increased cardiac output was simulated. CONCLUSION: Reducing contrast material volume from 125 to 75 mL, increasing the rate to 6 or 8 mL/s, and use of a saline chaser result in an aortic enhancement profile that better matches the approximately 5-second imaging window possible with 64-MDCTA of the abdomen and pelvis. Even smaller volumes of contrast material may be adequate in patients with reduced cardiac output.


Asunto(s)
Medios de Contraste/administración & dosificación , Angiografía Coronaria/métodos , Yopamidol/administración & dosificación , Fantasmas de Imagen , Cloruro de Sodio/administración & dosificación , Tomografía Computarizada por Rayos X/métodos , Análisis de Varianza , Velocidad del Flujo Sanguíneo , Diseño de Equipo , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador
5.
Radiology ; 248(1): 140-7, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18566172

RESUMEN

PURPOSE: To determine the effect of two pairs of echo times (TEs) for in-phase (IP) and opposed-phase (OP) 3.0-T magnetic resonance (MR) imaging on (a) quantitative analysis prospectively in a phantom study and (b) diagnostic accuracy retrospectively in a clinical study of adrenal tumors, with use of various reference standards in the clinical study. MATERIALS AND METHODS: A fat-saline phantom was used to perform IP and OP 3.0-T MR imaging for various fat fractions. The institutional review board approved this HIPAA-compliant study, with waiver of informed consent. Single-breath-hold IP and OP 3.0-T MR images in 21 patients (14 women, seven men; mean age, 63 years) with 23 adrenal tumors (16 adenomas, six metastases, one adrenocortical carcinoma) were reviewed. The MR protocol involved two acquisition schemes: In scheme A, the first OP echo (approximately 1.5-msec TE) and the second IP echo (approximately 4.9-msec TE) were acquired. In scheme B, the first IP echo (approximately 2.4-msec TE) and the third OP echo (approximately 5.8-msec TE) were acquired. Quantitative analysis was performed, and analysis of variance was used to test for differences between adenomas and nonadenomas. RESULTS: In the phantom study, scheme B did not enable discrimination among voxels that had small amounts of fat. In the clinical study, no overlap in signal intensity (SI) index values between adenomas and nonadenomas was seen (P < .05) with scheme A. However, with scheme B, no overlap in the adrenal gland SI-to-liver SI ratio between adenomas and nonadenomas was seen (P < .05). With scheme B, no overlap in adrenal gland SI index-to-liver SI index ratio between adenomas and nonadenomas was seen (P < .05). CONCLUSION: This initial experience indicates SI index is the most reliable parameter for characterization of adrenal tumors with 3.0-T MR imaging when obtaining OP echo before IP echo. When acquiring IP echo before OP echo, however, nonadenomas can be mistaken as adenomas with use of the SI index value.


Asunto(s)
Adenoma/diagnóstico , Neoplasias de las Glándulas Suprarrenales/diagnóstico , Imagen Eco-Planar/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Radiology ; 246(1): 125-32, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18096533

RESUMEN

PURPOSE: To prospectively evaluate, for the depiction of simulated hypervascular liver lesions in a phantom, the effect of a low tube voltage, high tube current computed tomographic (CT) technique on image noise, contrast-to-noise ratio (CNR), lesion conspicuity, and radiation dose. MATERIALS AND METHODS: A custom liver phantom containing 16 cylindric cavities (four cavities each of 3, 5, 8, and 15 mm in diameter) filled with various iodinated solutions to simulate hypervascular liver lesions was scanned with a 64-section multi-detector row CT scanner at 140, 120, 100, and 80 kVp, with corresponding tube current-time product settings at 225, 275, 420, and 675 mAs, respectively. The CNRs for six simulated lesions filled with different iodinated solutions were calculated. A figure of merit (FOM) for each lesion was computed as the ratio of CNR2 to effective dose (ED). Three radiologists independently graded the conspicuity of 16 simulated lesions. An anthropomorphic phantom was scanned to evaluate the ED. Statistical analysis included one-way analysis of variance. RESULTS: Image noise increased by 45% with the 80-kVp protocol compared with the 140-kVp protocol (P < .001). However, the lowest ED and the highest CNR were achieved with the 80-kVp protocol. The FOM results indicated that at a constant ED, a reduction of tube voltage from 140 to 120, 100, and 80 kVp increased the CNR by factors of at least 1.6, 2.4, and 3.6, respectively (P < .001). At a constant CNR, corresponding reductions in ED were by a factor of 2.5, 5.5, and 12.7, respectively (P < .001). The highest lesion conspicuity was achieved with the 80-kVp protocol. CONCLUSION: The CNR of simulated hypervascular liver lesions can be substantially increased and the radiation dose reduced by using an 80-kVp, high tube current CT technique.


Asunto(s)
Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/diagnóstico por imagen , Modelos Anatómicos , Tomografía Computarizada por Rayos X/métodos , Electricidad , Estudios Prospectivos , Dosis de Radiación
7.
Radiology ; 247(2): 558-66, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18349313

RESUMEN

PURPOSE: To retrospectively assess the diagnostic performance of time-resolved magnetic resonance (MR) angiography in the detection of stenoses and occlusions in the central veins of the chest, with angiographic and surgical findings and consensus readings serving as the reference standard. MATERIALS AND METHODS: Institutional review board approval was obtained, and the informed consent requirement was waived for this HIPAA-compliant study. Retrospective analysis was performed with 27 consecutive patients (12 male, 15 female; age range, 16-67 years) who underwent MR venography of the central veins. Six radiologists with varying levels of experience interpreted the studies. For each study, the readers were presented with time-resolved maximum intensity projection (MIP) images only, high-spatial-resolution images only, or both. Sensitivity and specificity were calculated for detection of stenoses and occlusions, as well as for confidence levels, study interpretation time, and determination of the side of the body on which upper extremity contrast material injection was performed. RESULTS: The addition of time-resolved angiographic images to the high-spatial-resolution images resulted in improved specificity in the detection of venous occlusions (0.99 vs 0.96, P = .03), in reader confidence (P < .001), and in the ability to infer the side of injection (83% correct compared with 32% correct, P < .001), without increasing the average time required for study interpretation. Use of time-resolved angiographic data sets as a stand-alone technique had high sensitivity (0.95) but only moderate specificity (0.56) in the detection of venous stenoses or occlusions. CONCLUSION: Time-resolved angiographic images are a useful adjunct to high-spatial-resolution images in the evaluation of central venous stenoses and occlusions.


Asunto(s)
Angiografía por Resonancia Magnética/métodos , Tórax/irrigación sanguínea , Enfermedades Vasculares/diagnóstico , Adolescente , Adulto , Anciano , Análisis de Varianza , Constricción Patológica , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Flebografía , Estudios Retrospectivos , Sensibilidad y Especificidad
8.
Med Phys ; 35(4): 1358-64, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18491530

RESUMEN

The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographic system using techniques comparable to chest radiography. The phantom design enabled observer evaluation by a four-alternative forced choice paradigm. The acquired images were independently scored by five observers on five medical display devices: a 5 megapixel monochrome LCD, a 3 megapixel monochrome LCD, a 9 megapixel color LCD, a 5 megapixel monochrome CRT, and a mammographic-grade monochrome CRT. The data were analyzed using the method suggested by the manufacturer based on a nearest neighbor correction technique. They were further analyzed using a logistic regression response model with a natural threshold using an overall chi-square test for display type followed by pairwise comparisons for individual display performance. The differences between the display devices were small. The standard analysis of the results based on the manufacturer-recommended method did not yield any statistically discernible trend among displays. The logistic regression analysis, however, indicated that the 5 megapixel monochrome LCD was statistically significantly (p <0.0001) superior to the others, followed by the 3 megapixel monochrome LCD (p<0.0001). The three other displays exhibited lower but generally similar performance characteristics. The findings suggest that 5 and 3 megapixel monochrome LCDs provide comparable but subtly superior contrast detectability than other tested displays, with the former performing slightly better in the detection of subtle and fine details.


Asunto(s)
Terminales de Computador , Sensibilidad de Contraste , Presentación de Datos , Tomografía Computarizada por Rayos X/instrumentación , Interfaz Usuario-Computador , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
9.
Med Phys ; 35(6): 2204-13, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18649449

RESUMEN

Under typical dark conditions encountered in diagnostic reading rooms, a reader's pupils will contract and dilate as the visual focus intermittently shifts between the high luminance display and the darker background wall, resulting in increased visual fatigue and the degradation of diagnostic performance. A controlled increase of ambient lighting may, however, reduce the severity of these pupillary adjustments by minimizing the difference between the luminance level to which the eyes adapt while viewing an image (L(adp)) and the luminance level of diffusely reflected light from the area surrounding the display (L(s)). Although ambient lighting in reading rooms has conventionally been kept at a minimum to maintain the perceived contrast of film images, proper Digital Imaging and Communications in Medicine (DICOM) calibration of modern medical-grade liquid crystal displays can compensate for minor lighting increases with very little loss of image contrast. This paper describes two psychophysical studies developed to evaluate and refine optimum reading room ambient lighting conditions through the use of observational tasks intended to simulate real clinical practices. The first study utilized the biologic contrast response of the human visual system to determine a range of representative L(adp) values for typical medical images. Readers identified low contrast horizontal objects in circular foregrounds of uniform luminance (5, 12, 20, and 30 cd/m2) embedded within digitized mammograms. The second study examined the effect of increased ambient lighting on the detection of subtle objects embedded in circular foregrounds of uniform luminance (5, 12, and 35 cd/m2) centered within a constant background of 12 cd/m2 luminance. The images were displayed under a dark room condition (1 lux) and an increased ambient lighting level (50 lux) such that the luminance level of the diffusely reflected light from the background wall was approximately equal to the image L(adp) value of 12 cd/m2. Results from the first study demonstrated that observer true positive and false positive detection rates and true positive detection times were considerably better while viewing foregrounds at 12 and 20 cd/m2 than at the other foreground luminance levels. Results from the second study revealed that under increased room illuminance, the average true positive detection rate improved a statistically significant amount from 39.3% to 55.6% at 5 cd/m2 foreground luminance. Additionally, the true positive rate increased from 46.4% to 56.6% at 35 cd/m2 foreground luminance, and decreased slightly from 90.2% to 87.5% at 12 cd/m2 foreground luminance. False positive rates at all foreground luminance levels remained approximately constant with increased ambient lighting. Furthermore, under increased room illuminance, true positive detection times declined at every foreground luminance level, with the most considerable decrease (approximately 500 ms) at the 5 cd/m2 foreground luminance. The first study suggests that L(adp) of typical mammograms lies between 12 and 20 cd/m2, leading to an optimum reading room illuminance of approximately 50-80 lux. Findings from the second study provide psychophysical evidence that ambient lighting may be increased to a level within this range, potentially improving radiologist comfort, without deleterious effects on diagnostic performance.


Asunto(s)
Diagnóstico por Imagen/métodos , Iluminación/métodos , Medicina Clínica , Luz , Fenómenos Fisiológicos Oculares , Psicofísica , Factores de Tiempo
10.
Med Phys ; 35(6): 2554-7, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18649488

RESUMEN

The authors report interim clinical results from an ongoing NIH-sponsored trial to evaluate digital chest tomosynthesis for improving detectability of small lung nodules. Twenty-one patients undergoing computed tomography (CT) to follow up lung nodules were consented and enrolled to receive an additional digital PA chest radiograph and digital tomosynthesis exam. Tomosynthesis was performed with a commercial CsI/a-Si flat-panel detector and a custom-built tube mover. Seventy-one images were acquired in 11 s, reconstructed with the matrix inversion tomosynthesis algorithm at 5-mm plane spacing, and then averaged (seven planes) to reduce noise and low-contrast artifacts. Total exposure for tomosynthesis imaging was equivalent to that of 11 digital PA radiographs (comparable to a typical screen-film lateral radiograph or two digital lateral radiographs). CT scans (1.25-mm section thickness) were reviewed to confirm presence and location of nodules. Three chest radiologists independently reviewed tomosynthesis images and PA chest radiographs to confirm visualization of nodules identified by CT. Nodules were scored as: definitely visible, uncertain, or not visible. 175 nodules (diameter range 3.5-25.5 mm) were seen by CT and grouped according to size: < 5, 5-10, and > 10 mm. When considering as true positives only nodules that were scored definitely visible, sensitivities for all nodules by tomosynthesis and PA radiography were 70% (+/- 5%) and 22% (+/- 4%), respectively, (p < 0.0001). Digital tomosynthesis showed significantly improved sensitivity of detection of known small lung nodules in all three size groups, when compared to PA chest radiography.


Asunto(s)
Pulmón/diagnóstico por imagen , Pulmón/patología , National Institutes of Health (U.S.) , Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/métodos , Tomografía/métodos , Estudios de Cohortes , Humanos , Sensibilidad y Especificidad , Estados Unidos
11.
AJR Am J Roentgenol ; 190(4): 976-83, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18356445

RESUMEN

OBJECTIVE: The objective of our study was to test the hypothesis that the finding of hyperintense hippocampal signal intensity on T2-weighted MR images soon after febrile status epilepticus is associated with subsequent hippocampal volume loss and persistent abnormal signal intensity on T2-weighted images (i.e., mesial temporal sclerosis). SUBJECTS AND METHODS: Eleven children (mean age, 25 months) underwent initial MRI that included coronal temporal lobe imaging within 72 hours of febrile status epilepticus and follow-up imaging from 3 to 23 months later (mean, 9 months). A neuroradiologist blinded to clinical history graded initial and follow-up hippocampal signal intensity on a scale from 0 (normal) to 4 (markedly increased). Two blinded observers measured hippocampal volumes on initial and follow-up MR studies using commercially available software and volumes from 30 healthy children (mean age, 6.3 years). Initial signal intensity and hippocampal volume changes were compared using Kendall tau correlation coefficients. RESULTS: On initial imaging, hyperintense signal intensity ranging from 1 (minimally increased) to 4 (markedly increased) was seen in seven children. Four children had at least one hippocampus with moderate or marked signal abnormality, three children had a hippocampus with mild or minimal abnormality, and four children had normal signal intensity. The Kendall tau correlation coefficient between signal intensity increase and volume change was -0.68 (p < 0.01). Five children (two with temporal lobe epilepsy and two with complex partial seizures) had hippocampal volume loss and increased signal intensity on follow-up imaging, meeting the criteria for mesial temporal sclerosis. CONCLUSION: MRI findings of a markedly hyperintense hippocampus in children with febrile status epilepticus was highly associated with subsequent mesial temporal sclerosis.


Asunto(s)
Epilepsia del Lóbulo Temporal/patología , Hipocampo/patología , Imagen por Resonancia Magnética/métodos , Convulsiones Febriles/patología , Estado Epiléptico/patología , Niño , Preescolar , Epilepsia del Lóbulo Temporal/etiología , Femenino , Humanos , Lactante , Modelos Lineales , Masculino , Estudios Prospectivos , Esclerosis/etiología , Esclerosis/patología , Convulsiones Febriles/complicaciones , Estado Epiléptico/complicaciones
12.
AJR Am J Roentgenol ; 191(1): 190-7, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18562745

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate radiologists' agreement when using a 10-point scale of abnormal findings designed to standardize reporting of abdominal radiographs in neonates or infants with suspected necrotizing enterocolitis. MATERIALS AND METHODS: A 10-point scale of radiographic findings was devised at our institution and was in use for approximately 18 months before the initiation of this study. After institutional review board approval, 88 abdominal radiographs (anteroposterior and cross-table lateral) were randomly selected for review, allowing for an equal distribution of examinations throughout the scale according to the original examination report. The mean age of the patients in the total study population was 24.9 days (range, 0-56 days); 61 patients (47.3%) were girls and 68 (52.7%) were boys. Four pediatric radiologists having 20, 13, 7, and 5 years of experience scored images twice at least 4 weeks apart according to the scale, which was designed to characterize certainty and severity of disease in neonates and infants with possible necrotizing enterocolitis. Interobserver and intraobserver agreement was assessed by applying weighted kappa statistics. Operative and pathology reports were reviewed. RESULTS: The average intraobserver weighted kappa value was 0.792 (SD, 0.025; range, 0.635-0.946). The average interobserver weighted kappa value was 0.665 (SD, 0.035, range, 0.574-0.898). CONCLUSION: Substantial intraobserver and interobserver agreement was found when radiologists used a 10-point scale to report abnormal findings on abdominal radiographs in neonates or infants with suspected necrotizing enterocolitis. This scale warrants further evaluation as a potentially useful clinical tool.


Asunto(s)
Enterocolitis Necrotizante/diagnóstico por imagen , Radiografía Abdominal/métodos , Índice de Severidad de la Enfermedad , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
AJR Am J Roentgenol ; 190(2): W100-5, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18212190

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. MATERIALS AND METHODS: One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. RESULTS: Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). CONCLUSION: Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.


Asunto(s)
Carga Corporal (Radioterapia) , Tamaño Corporal , Fantasmas de Imagen , Radiografía Abdominal/métodos , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Dosis de Radiación , Efectividad Biológica Relativa , Estadística como Asunto , Tomografía Computarizada por Rayos X/instrumentación
14.
Invest Radiol ; 42(6): 399-405, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17507811

RESUMEN

OBJECTIVES: To determine quantitative and qualitative image quality in patients undergoing magnetic resonance (MR) cholangiography at 3.0 Tesla (T) compared with 1.5 T. MATERIALS AND METHODS: Fifty patients (30 women; mean age, 51 years) underwent MR cholangiography at 1.5 T; another 50 patients (25 women; mean age 51 years) were scanned at 3.0 T. MR sequence protocol consisted of breath-hold single-slice rapid acquisition with relaxation enhancement (RARE) and a respiratory-triggered 3D turbo spin echo (3D TSE) sequence. Maximum intensity projections were generated from the 3D TSE datasets. Contrast-to-noise ratio (CNR) measurements between the common bile duct (CBD), left and right intrahepatic duct (LHD, RHD), and periductal tissue were performed. Three radiologists assessed qualitatively the visibility of the CBD, LHD, and RHD and the overall diagnostic quality. RESULTS: Mean gain in CNR at 3.0 T versus 1.5 T in all 3 locations ranged for the RARE sequence from 7.7% to 38.1% and for the 3D TSE from 0.5% to 26.1% (P > 0.05 for all differences). Qualitative analysis did not reveal any significant difference between the 2 field strengths (P > 0.05). CONCLUSIONS: MR cholangiography at 3.0 T shows a trend toward higher CNR without improving image quality significantly.


Asunto(s)
Enfermedades de las Vías Biliares/diagnóstico , Pancreatocolangiografía por Resonancia Magnética/métodos , Pancreatitis/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Estadísticas no Paramétricas
15.
Med Phys ; 34(8): 3385-98, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17879801

RESUMEN

The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original mammograms. The mammograms were converted into luminance values corresponding to those displayed on a clinical soft-copy display station and subsequently analyzed by Laguerre-Gauss and Gabor channelized Hotelling observer models for differences in detectability performance with reduction in radiation dose. Performance was measured under a signal known exactly but variable detection task paradigm in terms of receiver operating characteristics (ROC) curves and area under the ROC curves. The results suggested that luminance mapping of digital mammograms affects performance of model observers. Reduction in dose levels by 50% lowered the detectability of masses with borderline statistical significance. Dose reduction did not have a statistically significant effect on detection of microcalcifications. The model results indicate that there is room for optimization of dose level in mammographic screening procedures.


Asunto(s)
Mamografía/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos , Área Bajo la Curva , Simulación por Computador , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Teóricos , Variaciones Dependientes del Observador , Curva ROC , Radiometría , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Med Phys ; 34(10): 3971-81, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17985642

RESUMEN

The purpose of this study was to examine the effects of different resolution and noise levels on task performance in digital mammography. This study created an image set with images at three different resolution levels, corresponding to three digital display devices, and three different noise levels, with noise magnitudes similar to full clinical dose, half clinical dose, and quarter clinical dose. The images were read by five experienced breast imaging radiologists. The data were then analyzed to compute two accuracy statistics (overall classification accuracy and lesion detection accuracy) and performance at four diagnostic tasks (detection of microcalcifications, benign masses, malignant masses, and discrimination of benign and malignant masses). Human observer results showed decreasing display resolution had little effect on overall classification accuracy and individual diagnostic task performance, but increasing noise caused overall classification accuracy to decrease by a statistically significant 21% as the breast dose went to one quarter of its normal clinical value. The noise effects were most prominent for the tasks of microcalcification detection and mass discrimination. When the noise changed from full clinical dose to quarter clinical dose, the microcalcification detection performance fell from 89% to 67% and the mass discrimination performance decreased from 93% to 79%, while malignant mass detection performance remained relatively constant with values of 88% and 84%, respectively. As a secondary aim, the image set was also analyzed by two observer models to examine whether their performance was similar to humans. Observer models differed from human observers and each other in their sensitivity to resolution degradation and noise. The primary conclusions of this study suggest that quantum noise appears to be the dominant image quality factor in digital mammography, affecting radiologist performance much more profoundly than display resolution.


Asunto(s)
Mamografía/métodos , Mamografía/normas , Radiología/métodos , Artefactos , Presentación de Datos , Humanos , Procesamiento de Imagen Asistido por Computador , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica , Magnificación Radiográfica , Reproducibilidad de los Resultados , Técnica de Sustracción
17.
AJR Am J Roentgenol ; 189(2): 476-86, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17646476

RESUMEN

OBJECTIVE: The purpose of this study was to use diffusion-weighted and diffusion tensor imaging to investigate the status of cerebral white matter (WM) at term gestation and the rate of WM maturation throughout the first year of life in healthy infants. MATERIALS AND METHODS: Fifty-three children (35 boys) ranging in age from 1.5 weeks premature to 51.5 weeks (mean age, 22.9 weeks) underwent conventional MRI, diffusion imaging in three directions (b = 1,000 s/mm2), and diffusion tensor imaging with gradient encoding in six directions, all on a 1.5-T MRI system. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) were measured in three deep WM structures (posterior limb of internal capsule, genu, and splenium of corpus callosum) and two peripheral WM regions (associational WM underlying prefrontal and posterior parietal cortex) with a standard region of interest (44 +/- 4 cm2). ADC and FA were expressed as a percentage of corresponding values measured in a group of healthy young adults. Mean ADC and FA values for deep and peripheral WM were plotted against gestational age normalized to term. The data were fit best with a broken-line linear regression model with a breakpoint at 100 days. ADC and FA values at term were estimated according to the intercept of the initial linear period (before day 100) with day 0. The slope of the linear fits was used to determine the rate of WM maturation in both the early and the late (after day 100) periods. Multivariate analysis of variance tests were used to compare deep and peripheral WM structures at term and at representative early and late ages (days 30 and 200) and to compare rates of ADC and FA maturation in early and late periods within the first year. RESULTS: At term, peripheral WM was less mature than deep WM according to results of extrapolation of ADC and FA values in the first 100 days of life to day 0 (p < 0.01). Mean ADC and FA value (percentage of mean adult value) for peripheral WM were 1.32 x 10(-3) mm2/s (163%) and 0.16 (32%), respectively, and 1.09 x 10(-3) mm2/s (143%) and 0.36 (54%), respectively, for deep WM. On day 30 and day 200, estimated mean ADC and FA continued to show greater diffusion (higher ADC) and less anisotropy (lower FA value) in peripheral WM (p <0.01). During the first year of postnatal life, both ADC and FA matured at higher rates before postnatal day 100 compared with a later time. Differences were observed in rates of maturation in the first 100 days when rates of decrease in ADC and increase in FA were compared between peripheral WM and deep WM; however, the maturational trends differed whether ADC or FA was examined. The early rate of ADC decrease (maturation) was twice as great for peripheral WM than for deep WM (p < 0.01) unexpectedly, but the opposite pattern was observed for FA. The early rate of FA increase (maturation) was approximately one half as great for peripheral WM as for deep WM (p = 0.01). Throughout the rest of the first year, no differences were observed in the rates of change in either index between peripheral WM and deep WM. CONCLUSION: At term, both ADC and FA differ significantly in peripheral WM and deep WM, deep WM structures being more mature. Both deep WM and peripheral WM mature more rapidly during approximately the first 3 months in comparison with the rest of the first year. Unexpected differences in early (first 100 days) rates of maturation assessed with diffusion-weighted (ADC) and diffusion tensor (FA) imaging suggest that these two techniques may be sensitive to different aspects of WM maturation in the early perinatal period.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/crecimiento & desarrollo , Imagen de Difusión por Resonancia Magnética/métodos , Anisotropía , Femenino , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Modelos Lineales , Masculino , Valores de Referencia
18.
AJR Am J Roentgenol ; 188(3): W233-8, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17312028

RESUMEN

OBJECTIVE: The purposes of this study were to determine the accuracy of abdominal radiography in the detection of acute small-bowel obstruction (SBO), to assess the role of reviewer experience, and to evaluate individual radiographic signs of SBO. MATERIALS AND METHODS: A retrospective study was performed in which the subjects were 90 patients with suspected SBO who underwent CT and abdominal radiography within 48 hours of each other. The patients were enrolled from June 1, 2003, to February 2004. Twenty-nine of the patients had proven SBO. Hard-copy radiographs were reviewed by three groups of radiologists: senior staff, junior staff, and second-year radiology residents. Each reviewer evaluated the quality of the radiographs, patient position for acquisition of the radiographs, and whether SBO was present. The reviewers rated their confidence on a five-point scale and recorded the presence or absence of specific radiographic signs of SBO. Chi-square tests were used to compare the three groups. A statistically significant finding was considered p < 0.05. Receiver operating characteristic (ROC) curves were fit with a 10-point confidence scale. RESULTS: The sensitivity for SBO among the six reviewers ranged from 59% to 93%. The senior staff members were significantly more accurate. The mean sensitivity, specificity, and accuracy for all six reviewers were 82%, 83%, and 83%, respectively. Three radiographic signs were highly significant (p < 0.001): two or more air-fluid levels, air-fluid levels wider than 2.5 cm, and air-fluid levels differing more than 5 mm from one another in the same loop of small bowel. ROC analysis showed that senior staff is significantly more accurate than the other groups in the detection of acute SBO. CONCLUSION: Our results confirmed that abdominal radiographs are accurate in the detection of acute SBO, that more-experienced radiologists are more accurate than less-experienced reviewers in the evaluation of abdominal radiographs, and that three types of air-fluid levels are highly predictive of the presence of SBO.


Asunto(s)
Obstrucción Intestinal/diagnóstico por imagen , Obstrucción Intestinal/epidemiología , Intestino Delgado/diagnóstico por imagen , Competencia Profesional/estadística & datos numéricos , Radiografía Abdominal/estadística & datos numéricos , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/estadística & datos numéricos
19.
Toxicol Lett ; 175(1-3): 111-7, 2007 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-18024011

RESUMEN

Historically, antidotal potencies of cyanide antagonists were measured as increases in the experimental LD(50) for cyanide elicited by the antidotes. This required the use of high doses of cyanide following pre-treatment with the putative antidote. Since IACUC guidelines at our institutions strongly discourage LD(50) determinations: we developed a new test paradigm that allowed for maximal survival of cyanide-treated animals with greatly reduced numbers of animals. Symptoms of cyanide toxicity include disruption of neuromuscular coordination, i.e., the righting reflex. Therefore, to establish a dose-response curve, the times required for recovery of this righting reflex with increasing doses of cyanide were measured. A cyanide dose that disrupted this righting reflex for approximately 1h with minimal deaths was then selected. Using this paradigm, the current cyanide antidotes, viz., nitrite plus thiosulfate and hydroxocobalamin, as well as some potential cyanide antidotes that we developed, were evaluated pre- and post-cyanide. This allowed, for the first time, the assessment of the post-cyanide effectiveness of the current antidotes against cyanide poisoning in a live animal. In addition, some prototype compounds were found to exhibit antidotal efficacy not only when injected i.p. following cyanide, but also when administered orally 30 min before cyanide. Pre-cyanide oral efficacy suggests that such compounds have the potential of being administered prophylactically before exposure to cyanide. This new test paradigm was found to be a powerful tool for assessing the efficacies of some novel antidotes against cyanide and should be equally applicable for evaluating putative antidotes for other neurotoxins.


Asunto(s)
Antídotos/uso terapéutico , Neurotoxinas/envenenamiento , Cianuro de Sodio/envenenamiento , Animales , Antídotos/administración & dosificación , Quimioterapia Combinada , Hidroxocobalamina/administración & dosificación , Hidroxocobalamina/uso terapéutico , Masculino , Ratones , Reflejo/efectos de los fármacos , Nitrito de Sodio/administración & dosificación , Nitrito de Sodio/uso terapéutico , Tiosulfatos/administración & dosificación , Tiosulfatos/uso terapéutico , Resultado del Tratamiento
20.
Acad Radiol ; 14(4): 486-94, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17368219

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.


Asunto(s)
Obesidad , Radiografía Abdominal/normas , Tomografía Computarizada por Rayos X/normas , Análisis de Varianza , Calibración , Femenino , Humanos , Fantasmas de Imagen , Dosis de Radiación , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA