Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Infect Dis ; 201(6): 835-42, 2010 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-20136413

RESUMEN

Immune activation has been suggested to increase susceptibility to human immunodeficiency virus type 1 (HIV-1) transmission, while at the same time it could be deemed essential for mounting an effective antiviral immune response. In this study, we compared levels of T cell activation between exposed seronegative (ESN) partners in HIV-1 discordant couples and HIV-unexposed control subjects in Dakar, Senegal. ESN subjects showed lower levels of CD38 expression on CD4(+) T cells than did control subjects. However, this was found to be associated with concurrent differences in the use of condoms: ESN subjects reported a higher degree of condom use than did control subjects, which correlated inversely with CD38 expression. In addition, we observed markedly higher levels of T cell activation in women compared with men, irrespective of sexual behavior. These findings question the relevance of low-level CD4(+) T cell activation in resistance to HIV-1 infection and underscore the need to take gender and sexual behavior characteristics of high-risk populations into account when analyzing correlates of protective immunity.


Asunto(s)
Linfocitos T CD4-Positivos/inmunología , Infecciones por VIH/inmunología , Seronegatividad para VIH/inmunología , VIH-1/inmunología , Activación de Linfocitos/inmunología , ADP-Ribosil Ciclasa 1/sangre , Adolescente , Adulto , Linfocitos T CD8-positivos/inmunología , Estudios de Casos y Controles , Condones/estadística & datos numéricos , Femenino , Infecciones por VIH/sangre , Infecciones por VIH/epidemiología , Infecciones por VIH/transmisión , Humanos , Entrevistas como Asunto , Masculino , Glicoproteínas de Membrana/sangre , Persona de Mediana Edad , Senegal/epidemiología , Distribución por Sexo , Conducta Sexual , Adulto Joven
2.
PLoS One ; 10(2): e0116663, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25688553

RESUMEN

BACKGROUND: A new CD4 point-of-care instrument, the CyFlow miniPOC, which provides absolute and percentage CD4 T-cells, used for screening and monitoring of HIV-infected patients in resource-limited settings, was introduced recently. We assessed the performance of this novel instrument in a reference laboratory and in a field setting in Senegal. METHODOLOGY: A total of 321 blood samples were obtained from 297 adults and 24 children, all HIV-patients attending university hospitals in Dakar, or health centers in Ziguinchor. Samples were analyzed in parallel on CyFlow miniPOC, FACSCount CD4 and FACSCalibur to assess CyFlow miniPOC precision and accuracy. RESULTS: At the reference lab, CyFlow miniPOC, compared to FACSCalibur, showed an absolute mean bias of -12.6 cells/mm3 and a corresponding relative mean bias of -2.3% for absolute CD4 counts. For CD4 percentages, the absolute mean bias was -0.1%. Compared to FACSCount CD4, the absolute and relative mean biases were -31.2 cells/mm3 and -4.7%, respectively, for CD4 counts, whereas the absolute mean bias for CD4 percentages was 1.3%. The CyFlow miniPOC was able to classify HIV-patients eligible for ART with a sensitivity of ≥ 95% at the different ART-initiation thresholds (200, 350 and 500 CD4 cells/mm3). In the field lab, the room temperature ranged from 30 to 35°C during the working hours. At those temperatures, the CyFlow miniPOC, compared to FACSCount CD4, had an absolute and relative mean bias of 7.6 cells/mm3 and 2.8%, respectively, for absolute CD4 counts, and an absolute mean bias of 0.4% for CD4 percentages. The CyFlow miniPOC showed sensitivity equal or greater than 94%. CONCLUSION: The CyFlow miniPOC showed high agreement with FACSCalibur and FACSCount CD4. The CyFlow miniPOC provides both reliable absolute CD4 counts and CD4 percentages even under the field conditions, and is suitable for monitoring HIV-infected patients in resource-limited settings.


Asunto(s)
Recuento de Linfocito CD4/métodos , Citometría de Flujo/métodos , Sistemas de Atención de Punto , Adolescente , Adulto , Anciano , Terapia Antirretroviral Altamente Activa , Niño , Preescolar , Femenino , Citometría de Flujo/instrumentación , Infecciones por VIH/sangre , Infecciones por VIH/tratamiento farmacológico , Humanos , Lactante , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Senegal , Adulto Joven
3.
J Immunol Methods ; 372(1-2): 7-13, 2011 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-21835181

RESUMEN

Laboratory follow-up of HIV patients in resource-limited settings requires appropriate instruments for CD4 T cell enumeration. In this study, we evaluated the application of a simplified, mobile and robust flow cytometry system, the Apogee Auto 40 analyzer (Auto40) using thermoresistant reagents, for CD4 T cell enumeration. We measured the absolute CD4 counts in fresh whole blood samples from 170 Senegalese subjects, including 129 HIV-positive (HIV+) patients and 41 HIV-negative (HIV-) controls. Based on volumetric primary CD4 gating, cells were stained with commercially available reagents (Easy MoAb CD4;Bio-D, Valenzano, Italy) and analyzed on the Auto40. The results were compared with those from the FACSCount system (Becton Dickinson, San Jose, USA). Repeatability analysis was performed on duplicate testing of 49 samples on both FACSCount and Auto40. The intra-run precision was measured by 10 replicates using 3 clinical blood samples with low, intermediate and high CD4 concentrations. The results from the two instruments were in good agreement. The percent similarity between the results of both instruments was 99%±relative standard deviation of 12.7%. The concordance correlation coefficient was 0.99. The absolute bias and limits of agreement (LOA) between the two instruments, calculated by Bland-Altman analysis, were clinically acceptable (bias: +4 cells/µl; LOA: -111 to +120 cells/µl). The clinical agreement between the two instruments at a cutoff of 200 CD4 cells/µl was 94%. The repeatability of measurements on the Auto40 was also similar to that observed with FACSCount system (bias +0.1 cells/µl, coefficient of variation 2.5% vs bias -1.1cells/µl, coefficient of variation 2.9% respectively). In conclusion, our results indicate that the Auto 40 system, using thermoresistant reagents, is suitable for CD4 T cell enumeration and will be a helpful tool to improve HIV laboratory monitoring in resource-limited settings.


Asunto(s)
Recuento de Linfocito CD4/normas , Linfocitos T CD4-Positivos/inmunología , Citometría de Flujo/normas , Infecciones por VIH/inmunología , VIH/inmunología , Recuento de Linfocito CD4/métodos , Linfocitos T CD4-Positivos/citología , Linfocitos T CD4-Positivos/virología , Citometría de Flujo/instrumentación , Citometría de Flujo/métodos , Infecciones por VIH/sangre , Infecciones por VIH/virología , Humanos , Indicadores y Reactivos/normas , Análisis de Regresión , Reproducibilidad de los Resultados , Senegal
4.
J Acquir Immune Defic Syndr ; 41(4): 416-24, 2006 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-16652048

RESUMEN

Alternative, affordable, and simple assays to monitor antiretroviral therapy (ART) in resource-poor settings are needed. We have evaluated and compared a heat-denatured (HD) HIV p24 amplified enzyme-linked immunosorbent assay from Perkin-Elmer and CD38CD8 T-cell levels, determined by flow cytometry, for their capacity to predict viral load (VL) in HIV-1-infected patients from Senegal. Median fluorescence intensity (MFI) of CD38 expression on memory (CD45RO) CD8 T cells correlated better with RNA VL than HD p24 antigenemia (R = 0.576, P < 0.0001 vs R = 0.548, P < 0.0001). MFI of CD38 expression on memory CD8 T cells could predict detectable RNA VL (VL = 2.6 log10) with a sensitivity of 87% and a specificity of 74%. A comparable sensitivity (89%) could be reached for HD p24 assay, but only to predict RNA VL of more than 5 logs, which might lead to unacceptable delays in clinical decision making. The clinical use of the HD p24 assay to monitor ART in Senegal would require more comparative data about the kinetics of p24 antigen and HIV RNA in peripheral blood as well as further evaluation regarding its sensitivity toward subtype A and CRF02. MFI of CD38 expression on memory CD8 T cells appeared to be a better alternative to monitor ART in HIV-infected patients from Senegal.


Asunto(s)
Biomarcadores , Linfocitos T CD8-positivos , Proteína p24 del Núcleo del VIH/sangre , Infecciones por VIH/virología , VIH-1/fisiología , Subgrupos de Linfocitos T , Carga Viral , ADP-Ribosil Ciclasa 1/análisis , Ensayo de Inmunoadsorción Enzimática , Femenino , Citometría de Flujo , Infecciones por VIH/inmunología , Humanos , Masculino , ARN Viral/sangre , Senegal , Sensibilidad y Especificidad , Estadística como Asunto
5.
J Acquir Immune Defic Syndr ; 39(1): 32-7, 2005 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-15851911

RESUMEN

Flow cytometry is an accurate but expensive method to determine absolute CD4 cell counts. We compared different methods to measure absolute CD4 counts in blood samples from HIV-infected and uninfected subjects using a research/clinical flow cytometer (FACScan); a dedicated clinical instrument (FACSCount); and a volumetric, mobile, open-system flow cytometer equipped with 3 fluorescence and 2 light scatter detectors (Cyflow SL blue). The FACScan and Cyflow were used as single-platform instruments, but they differ in running cost, which is a central factor for resource-poor settings. Direct volumetric and bead-based CD4 measurements on the Cyflow were compared with 2 bead-based single-platform CD4 measurements on the FACSCount and on FACScan (TruCount) in "Le Dantec" Hospital, Dakar, Senegal, using whole blood samples from 102 HIV+ and 28 HIV- subjects. The agreement between the various measurement methods was evaluated by Bland-Altman analysis. Volumetric CD4 measurements on the Cyflow using a no-lyse-no-wash (NLNW) procedure and a lyse-no-wash (LNW) procedure correlated well with each other (R2 = 0.98) and with CD4 measurements on the FACSCount (R2 = 0.97) and FACScan (R2 = 0.97), respectively. Red blood cell lysis had no negative effect on the accuracy of absolute CD4 counting on the Cyflow. An excellent correlation was observed between bead-based CD4 measurements on the Cyflow and CD4 measurements on the FACSCount (R2 = 0.99) and FACScan (R2 = 0.99). Rigid internal and external quality control monitoring and adequate training of technicians were considered essential to generate accurate volumetric CD4 measurements on the Cyflow.


Asunto(s)
Recuento de Linfocito CD4/economía , Recuento de Linfocito CD4/métodos , Infecciones por VIH/sangre , Infecciones por VIH/inmunología , Bélgica , Costos y Análisis de Costo , Citometría de Flujo/métodos , Humanos , Inmunofenotipificación/métodos , Pobreza , Valores de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA