Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Occup Environ Hyg ; 20(1): 40-53, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36256682

RESUMEN

In emergencies like the COVID-19 pandemic, the reuse or reprocessing of filtering facepiece respirators (FFRs) may be required to mitigate exposure risk. Research gap: Only a few studies evaluated decontamination effectiveness against SARS-CoV-2 that are practical for low-resource settings. This study aimed to determine the effectiveness of a relatively inexpensive ultraviolet germicidal irradiation chamber to decontaminate FFRs contaminated with SARS-CoV-2. A custom-designed UVGI chamber was constructed to determine the ability to decontaminate seven FFR models including N95s, KN95, and FFP2s inoculated with SARS-CoV-2. Vflex was excluded due to design folds/pleats and UVGI shadowing inside the chamber. Structural and functional integrity tolerated by each FFR model on repeated decontamination cycles was assessed. Twenty-seven participants were fit-tested over 30 cycles for each model and passed if the fit factor was ≥100. Of the FFR models included for testing, only the KN95 model failed filtration. The 3M™ 3M 1860 and Halyard™ duckbill 46727 (formerly Kimberly Clark) models performed better on fit testing than other models for both pre-and-post decontaminations. Fewer participants (0.3 and 0.7%, respectively) passed fit testing for Makrite 9500 N95 and Greenline 5200 FFP2 and only two for the KN95 model post decontamination. Fit testing appeared to be more affected by donning & doffing, as some passed with adjustment and repeat fit testing. A ≥ 3 log reduction of SARS-CoV-2 was achieved for worn-in FFRs namely Greenline 5200 FFP2. Conclusion: The study showed that not all FFRs tested could withstand 30 cycles of UVGI decontamination without diminishing filtration efficiency or facial fit. In addition, SARS-CoV-2 log reduction varied across the FFRs, implying that the decontamination efficacy largely depends on the decontamination protocol and selection of FFRs. We demonstrated the effectiveness of a low-cost and scalable decontamination method for SARS-CoV-2 and the effect on fit testing using people instead of manikins. It is recognized that extensive experimental evidence for the reuse of decontaminated FFRs is lacking, and thus this study would be relevant and of interest in crisis-capacity settings, particularly in low-resource facilities.


Asunto(s)
COVID-19 , Humanos , COVID-19/prevención & control , SARS-CoV-2 , Pandemias/prevención & control , Descontaminación/métodos , Equipo Reutilizado , Ventiladores Mecánicos
2.
BMC Infect Dis ; 20(1): 621, 2020 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-32831057

RESUMEN

BACKGROUND: We aimed to describe an outbreak of cutaneous abscesses caused by Panton-Valentine leukocidin (PVL)-producing methicillin-susceptible Staphylococcus aureus (MSSA) among gold mine workers. METHODS: In February 2018, we retrospectively reviewed a random sample of 50 medical records from 243 cases and conducted face-to-face interviews using a structured questionnaire. Pus aspirates were sent to the National Institute for Communicable Diseases from prospectively-identified cases (November 2017-March 2018). Nasopharyngeal swabs were collected during a colonisation survey in February 2018. Staphylococcus aureus isolates were screened with a conventional PCR for lukS/F-PV. Pulsed-field gel electrophoresis (PFGE) was performed to determine the genetic relatedness among the isolates. A sample of isolates were selected for whole genome sequencing (WGS). We conducted an assessment on biological risks associated with mining activities. RESULTS: From January 2017 to February 2018, 10% (350/3582) of mine workers sought care for cutaneous abscesses. Forty-seven medical files were available for review, 96% were male (n = 45) with a mean age of 43 years (SD = 7). About 52% (24/46) were involved in stoping and 28% (13/47) worked on a particular level. We cultured S. aureus from 79% (30/38) of cases with a submitted specimen and 14% (12/83) from colonisation swabs. All isolates were susceptible to cloxacillin. Seventy-one percent of S. aureus isolates (30/42) were PVL-PCR-positive. Six PFGE clusters were identified, 57% (21/37) were closely related. WGS analysis found nine different sequence types. PFGE and WGS analysis showed more than one cluster of S. aureus infections involving closely related isolates. Test reports for feed and product water of the mine showed that total plate counts were above the limits of 1000 cfu/ml, coliform counts > 10 cfu/100 ml and presence of faecal coliforms. Best practices were poorly implemented as some mine workers washed protective clothing with untreated water and hung them for drying at the underground surface. CONCLUSIONS: PVL-producing MSSA caused an outbreak of cutaneous abscesses among underground workers at a gold mining company. To our knowledge, no other outbreaks of PVL-producing S. aureus involving skin and soft tissue infections have been reported in mining facilities in South Africa. We recommend that worker awareness of infection prevention and control practices be strengthened.


Asunto(s)
Absceso/microbiología , Enfermedades de la Piel/epidemiología , Infecciones de los Tejidos Blandos/epidemiología , Infecciones Estafilocócicas/epidemiología , Staphylococcus aureus/patogenicidad , Adulto , Toxinas Bacterianas/metabolismo , Brotes de Enfermedades , Electroforesis en Gel de Campo Pulsado , Exotoxinas/metabolismo , Femenino , Oro , Humanos , Leucocidinas/metabolismo , Masculino , Meticilina/farmacología , Persona de Mediana Edad , Mineros , Estudios Retrospectivos , Enfermedades de la Piel/microbiología , Infecciones de los Tejidos Blandos/microbiología , Sudáfrica/epidemiología , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/genética , Staphylococcus aureus/metabolismo
3.
Artículo en Inglés | MEDLINE | ID: mdl-34639431

RESUMEN

This study aimed to detect airborne Mycobacterium tuberculosis (MTB) at nine public health facilities in three provinces of South Africa and determine possible risk factors that may contribute to airborne transmission. Personal samples (n = 264) and stationary samples (n = 327) were collected from perceived high-risk areas in district, primary health clinics (PHCs) and TB facilities. Quantitative real-time (RT) polymerase chain reaction (PCR) was used for TB analysis. Walkabout observations and work practices through the infection prevention and control (IPC) questionnaire were documented. Statistical analysis was carried out using Stata version 15.2 software. Airborne MTB was detected in 2.2% of samples (13/572), and 97.8% were negative. District hospitals and Western Cape province had the most TB-positive samples and identified risk areas included medical wards, casualty, and TB wards. MTB-positive samples were not detected in PHCs and during the summer season. All facilities reported training healthcare workers (HCWs) on TB IPC. The risk factors for airborne MTB included province, type of facility, area or section, season, lack of UVGI, and ineffective ventilation. Environmental monitoring, PCR, IPC questionnaire, and walkabout observations can estimate the risk of TB transmission in various settings. These findings can be used to inform management and staff to improve the TB IPC programmes.


Asunto(s)
Mycobacterium tuberculosis , Exposición Profesional , Tuberculosis , Atención a la Salud , Personal de Salud , Humanos , Control de Infecciones , Mycobacterium tuberculosis/genética , Exposición Profesional/análisis , Sudáfrica/epidemiología , Tuberculosis/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA