1.
Anesthesiology ; 141(3): 443-452, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557791

RESUMEN

BACKGROUND: The Hypotension Prediction Index (the index) software is a machine learning algorithm that detects physiologic changes that may lead to hypotension. The original validation used a case control (backward) analysis that has been suggested to be biased. This study therefore conducted a cohort (forward) analysis and compared this to the original validation technique. METHODS: A retrospective analysis of data from previously reported studies was conducted. All data were analyzed identically with two different methodologies, and receiver operating characteristic curves were constructed. Both backward and forward analyses were performed to examine differences in area under the receiver operating characteristic curves for the Hypotension Prediction Index and other hemodynamic variables to predict a mean arterial pressure (MAP) less than 65 mmHg for at least 1 min 5, 10, and 15 min in advance. RESULTS: The analysis included 2,022 patients, yielding 4,152,124 measurements taken at 20-s intervals. The area under the curve for the index predicting hypotension analyzed by backward and forward methodologies respectively was 0.957 (95% CI, 0.947 to 0.964) versus 0.923 (95% CI, 0.912 to 0.933) 5 min in advance, 0.933 (95% CI, 0.924 to 0.942) versus 0.923 (95% CI, 0.911 to 0.933) 10 min in advance, and 0.929 (95% CI, 0.918 to 0.938) versus 0.926 (95% CI, 0.914 to 0.937) 15 min in advance. No variable other than MAP had an area under the curve greater than 0.7. The areas under the curve using forward analysis for MAP predicting hypotension 5, 10, and 15 min in advance were 0.932 (95% CI, 0.920 to 0.940), 0.929 (95% CI, 0.918 to 0.938), and 0.932 (95% CI, 0.921 to 0.940), respectively. The R2 for the variation in the index due to MAP was 0.77. CONCLUSIONS: Using an updated methodology, the study found that the utility of the Hypotension Prediction Index to predict future hypotensive events is high, with an area under the receiver operating characteristics curve similar to that of the original validation method.


Asunto(s)
Hipotensión , Humanos , Hipotensión/diagnóstico , Hipotensión/fisiopatología , Estudios Retrospectivos , Estudios de Casos y Controles , Masculino , Femenino , Estudios de Cohortes , Valor Predictivo de las Pruebas , Aprendizaje Automático , Persona de Mediana Edad , Curva ROC , Algoritmos
2.
BMC Anesthesiol ; 24(1): 257, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39075354

RESUMEN

BACKGROUND: To enhance the utility of functional hemodynamic monitoring, the variables systolic slope (dP/dt) and dynamic arterial elastance (Eadyn) are calculated by the Hypotension Prediction Index (HPI) Acumen® Software. This study was designed to characterize the effects of phenylephrine and ephedrine on dP/dt and Eadyn. METHODS: This was a retrospective, non-randomized analysis of data collected during two clinical studies. All patients required intra-operative controlled mechanical ventilation and had an indwelling radial artery catheter connected to an Acumen IQ sensor. Raw arterial pressure waveform data was downloaded from the patient monitor and all hemodynamic measurements were calculated off-line. The anesthetic record was reviewed for bolus administrations of either phenylephrine or ephedrine. Cardiovascular variables prior to drug administration were compared to those following vasopressor administrations. The primary outcome was the difference for dP/dt and Eadyn at baseline compared with the average after the bolus administration. All data sets demonstrated non-normal distributions so statistical analysis of paired and unpaired data followed the Wilcoxon matched pairs signed-rank test or Mann-Whitney U test, respectively. RESULTS: 201 doses of phenylephrine and 100 doses of ephedrine were analyzed. All data sets are reported as median [95% CI]. Mean arterial pressure (MAP) increased from 62 [54,68] to 78 [76,80] mmHg following phenylephrine and from 59 [55,62] to 80 [77,83] mmHg following ephedrine. Stroke volume and cardiac output both increased. Stroke volume variation and pulse pressure variation decreased. Both drugs produced significant increases in dP/dt, from 571 [531, 645] to 767 [733, 811] mmHg/sec for phenylephrine and from 537 [509, 596] to 848 [779, 930] mmHg/sec for ephedrine. No significant changes in Eadyn were observed. CONCLUSION: Bolus administration of phenylephrine or ephedrine increases dP/dt but does not change Eadyn. dP/dt demonstrates potential for predicting the inotropic response to phenylephrine or ephedrine, providing guidance for the most efficacious vasopressor when treating hypotension. TRIAL REGISTRATION: Data was collected from two protocols. The first was deemed to not require written, informed consent by the Institutional Review Board (IRB). The second was IRB-approved (Effect of Diastolic Dysfunction on Dynamic Cardiac Monitors) and registered on ClinicalTrials.gov (NCT04177225).


Asunto(s)
Efedrina , Fenilefrina , Vasoconstrictores , Humanos , Estudios Retrospectivos , Fenilefrina/farmacología , Fenilefrina/administración & dosificación , Vasoconstrictores/administración & dosificación , Vasoconstrictores/farmacología , Efedrina/administración & dosificación , Efedrina/farmacología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Hipotensión/tratamiento farmacológico
3.
BMC Anesthesiol ; 24(1): 117, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38532344

RESUMEN

BACKGROUND: Abnormal diastolic function is an independent predictor of adverse postoperative outcomes. Mitral annular tissue Doppler velocity (e') is a key parameter for assessing diastolic function. The purpose of this study was to confirm that an acute increase in preload did not significantly impact the intraoperative measurement of e' and secondarily evaluate the impact of this acute intravascular volume increase on the clinical assessment of diastolic function using a previously described simplified algorithm. METHODS: This was a prospective, non-randomized study in adult patients undergoing elective cardiac surgeries requiring transesophageal echocardiographic monitoring, arterial pressure and Swan-Ganz catheter placements as part of the surgical procedure. Following baseline echocardiographic and hemodynamic measurements, 500 ml of crystalloid solution was infused over 10 min. Hemodynamic and echocardiographic measurements were repeated 5 min after fluid administration. RESULTS: Complete data sets were available from 84 of the 100 patients who were enrolled in this study. There was no significant change in the values of e'. The average baseline was 7.8 ± 2.0 cm/s (95%CI: 7.4, 8.2) and 8.1 ± 2.4 (95%CI: 7.6, 8.6) following the fluid bolus (p = 0.10). All hemodynamic variables associated with increased intravascular volume (central venous pressure, pulmonary arterial pressures and stroke volume variation) changed significantly. The overall distribution of diastolic function grades did not change following fluid administration (p = 0.69). However, there were many individual patient differences. When using this simplified algorithm, functional grading changed in 35 patients. Thirty of these 35 changes were only a single grade shift. 22 patients had worse functional grading after fluid administration while 13 had improved grading. Nine patients with normal diastolic function at baseline demonstrated diastolic dysfunction after fluid administration while 6 patients with baseline dysfunction normalized following the fluid bolus. CONCLUSION: We confirmed that e' is a robust measurement that is reproducible in the intraoperative setting despite variable vascular volume loading conditions, however, the clinical assessment of diastolic function was still altered in 42% of the patients following an intravenous fluid bolus.


Asunto(s)
Válvula Mitral , Disfunción Ventricular Izquierda , Adulto , Humanos , Estudios Prospectivos , Diástole , Hemodinámica , Ecocardiografía
4.
J Clin Monit Comput ; 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39196478

RESUMEN

Pulse oximetry (SpO2) is a critical monitor for assessing oxygenation status and guiding therapy in critically ill patients. Race has been identified as a potential source of SpO2 error, with consequent bias and inequities in healthcare. This study was designed to evaluate the incidence of occult hypoxemia and accuracy of pulse oximetry associated with the Massey-Martin scale and characterize the relationship between Massey scores and self-identified race. This retrospective single institute study utilized the Massey-Martin scale as a quantitative assessment of skin pigmentation. These values were recorded peri-operatively in patients enrolled in unrelated clinical trials. The electronic medical record was utilized to obtain demographics, arterial blood gas values, and time matched SpO2 values for each PaO2 ≤ 125 mmHg recorded throughout their hospitalizations. Differences between SaO2 and SpO2 were compared as a function of both Massey score and self-reported race. 4030 paired SaO2-SpO2 values were available from 579 patients. The average error (SaO2-SpO2) ± SD was 0.23 ± 2.6%. Statistically significant differences were observed within Massey scores and among races, with average errors that ranged from - 0.39 ± 2.3 to 0.53 ± 2.5 and - 0.55 ± 2.1 to 0.37 ± 2.7, respectively. Skin color varied widely within each self-identified race category. There was no clinically significant association between error rates and Massey-Martin scale grades and no clinically significant difference in accuracy observed between self-reported Black and White patients. In addition, self-reported race is not an appropriate surrogate for skin color.

5.
BMC Anesthesiol ; 22(1): 297, 2022 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-36123624

RESUMEN

The Anesthesia Quality Institute (AQI) promotes improvements in clinical care outcomes by managing data entered in the National Anesthesia Clinical Outcomes Registry (NACOR). Each case included in NACOR is classified as "performance met" or "performance not met" and expressed as a percentage for a length of time. The clarity associated with this binary classification is associated with limitations on data analysis and presentations that may not be optimal guides to evaluate the quality of care. High compliance benchmarks present another obstacle for evaluating quality. Traditional approaches for interpreting statistical process control (SPC) charts depend on data points above and below a center line, which may not provide adequate characterizations of a QI process with a low failure rate, or few possible data points below the center line. This article demonstrates the limitations associated with the use of binary datasets to evaluate the quality of care at an individual organization with QI measures, describes a method for characterizing binary data with continuous variables and presents a solution to analyze rare QI events using g charts.


Asunto(s)
Anestesia , Anestesiología , Mejoramiento de la Calidad
6.
Anesthesiology ; 135(2): 273-283, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33901281

RESUMEN

BACKGROUND: Excessive or inadequate fluid administration causes complications, but despite this, fluid administration during noncardiac surgery is highly variable. Goal-directed management helps optimize the amount and timing of fluid administration; however, implementation is difficult because algorithms are complex. The authors therefore tested the performance of the Acumen Assisted Fluid Management software (Edwards Lifesciences, USA), which is designed to guide optimal intravenous fluid administration during surgery. METHODS: In this multicenter, prospective, single-arm cohort evaluation, the authors enrolled 330 adults scheduled for moderate- to high-risk noncardiac surgery that required arterial catheter insertion and mechanical ventilation. Clinicians chose a fluid strategy based on a desired 10%, 15%, or 20% increase in stroke volume (SV) in response to a fluid bolus. Dedicated fluid management software prompted "test" or "recommended" boluses, and clinicians were free to initiate a "user" bolus of 100 to 500 ml of crystalloid or colloid. Clinicians were free to accept or decline the software prompts. The authors primarily compared the fraction of software-recommended boluses that produced suitable increases in SV to a 30% reference rate. On an exploratory basis, we compared responses to software-recommended and clinician-initiated boluses. RESULTS: Four hundred twenty-four of 479 (89%) software-recommended fluid boluses and 508 of 592 (86%) clinician-initiated fluid boluses were analyzed per protocol. Of those, 66% (95% CI, 62 to 70%) of delivered fluid boluses recommended by the software resulted in desired increases in SV, compared with the 30% reference rate, whereas only 41% (95% CI, 38 to 44%) of clinician-initiated boluses did (P < 0.0001). The mean ± SD increase in SV after boluses recommended by the software was 14.2 ± 13.9% versus 8.3 ± 12.1% (P < 0.0001) for those initiated by clinicians. CONCLUSIONS: Fluid boluses recommended by the software resulted in desired SV increases more often, and with greater absolute SV increase, than clinician-initiated boluses. Automated assessment of fluid responsiveness may help clinicians optimize intraoperative fluid management during noncardiac surgery.


Asunto(s)
Fluidoterapia/métodos , Cuidados Intraoperatorios/métodos , Terapia Asistida por Computador/métodos , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
Anesth Analg ; 132(3): 770-776, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32815872

RESUMEN

BACKGROUND: Perioperative pulse oximetry hemoglobin saturation (Spo2) measurement is associated with fewer desaturation and hypoxia episodes. However, the sigmoidal nature of oxygen-hemoglobin dissociation limits the accuracy of estimation of the partial pressure of oxygen (Pao2) >80 mm Hg and correspondingly limits the ability to identify when Pao2 >80 mm Hg but falling. We hypothesized that a proxy measurement for oxygen saturation (Oxygen Reserve Index [ORI]) derived from multiwavelength pulse oximetry may allow additional warning time before critical desaturation or hypoxia. To test our hypothesis, we used a Masimo multiwavelength pulse oximeter to compare ORI and Spo2 warning times during apnea in high-risk surgical patients undergoing cardiac surgery. METHODS: This institutional review board-approved prospective study (NCT03021473) enrolled American Society of Anesthesiologists physical status III or IV patients scheduled for elective surgery with planned preinduction arterial catheter placement. In addition to standard monitors, an ORI sensor was placed and patients were monitored with a pulse oximeter displaying the ORI, a nondimensional parameter that ranges from 0 to 1. Patients were then preoxygenated until ORI plateaued. Following induction of anesthesia, mask ventilation with 100% oxygen was performed until neuromuscular blockade was established. Endotracheal intubation was accomplished using videolaryngoscopy to confirm placement. The endotracheal tube was not connected to the breathing circuit, and patients were allowed to be apneic. Ventilation was resumed when Spo2 reached 94%. We defined ORI warning time as the time from when the ORI alarm registered (based on the absolute value and the rate of change) until the Spo2 decreased to 94%. We defined the Spo2 warning time as the time for Spo2 to decrease from 97% to 94%. The added warning time provided by ORI was defined as the difference between ORI warning time and Spo2 warning time. RESULTS: Forty subjects were enrolled. Complete data for analysis were available from 37 patients. The ORI alarm registered before Spo2 decreasing to 97% in all patients. Median (interquartile range [IQR]) ORI warning time was 80.4 seconds (59.7-105.9 seconds). Median (IQR) Spo2 warning time was 29.0 seconds (20.5-41.0 seconds). The added warning time provided by ORI was 48.4 seconds (95% confidence interval [CI], 40.4-62.0 seconds; P < .0001). CONCLUSIONS: In adult high-risk surgical patients, ORI provided clinically relevant added warning time of impending desaturation compared to Spo2. This additional time may allow modification of airway management, earlier calls for help, or assistance from other providers. The potential patient safety impact of such monitoring requires further study.


Asunto(s)
Apnea/diagnóstico , Procedimientos Quirúrgicos Cardíacos , Alarmas Clínicas , Hipoxia/diagnóstico , Monitoreo Intraoperatorio , Oximetría , Oxihemoglobinas/metabolismo , Anciano , Apnea/sangre , Apnea/etiología , Biomarcadores/sangre , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Diagnóstico Precoz , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Hipoxia/sangre , Hipoxia/etiología , Intubación Intratraqueal , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Valor Predictivo de las Pruebas , Estudios Prospectivos , Respiración Artificial
8.
BMC Anesthesiol ; 21(1): 105, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33823811

RESUMEN

BACKGROUND: Intraoperative brain function monitoring with processed electroencephalogram (EEG) indices, such as the bispectral index (BIS) and patient state index (PSI), may improve characterization of the depth of sedation or anesthesia when compared to conventional physiologic monitors, such as heart rate and blood pressure. However, the clinical assessment of anesthetic depth may not always agree with available processed EEG indices. To concurrently compare the performance of BIS and SedLine monitors, we present a data collection system using shared individual generic sensors connected to a custom-built passive interface box. METHODS: This prospective, non-blinded, non-randomized study will enroll 100 adult American Society of Anesthesiologists (ASA) class I-III patients presenting for elective procedures requiring general anesthesia. BIS and SedLine electrodes will be placed preoperatively according to manufacturer recommendations and their respective indices tracked throughout anesthesia induction, maintenance and emergence. The concordance between processed EEG indices and clinical assessments of anesthesia depth will be analyzed with chi-square and kappa statistic. DISCUSSION: Prior studies comparing brain function monitoring devices have applied both sensors on the forehead of study subjects simultaneously. With limited space and common sensor locations between devices, it is not possible to place both commercial sensor arrays according to the manufacturer's recommendations, thus compromising the validity of these comparisons. This trial utilizes a custom interface allowing signals from sensors to be shared between BIS and SedLine monitors to provide an accurate comparison. Our results will also characterize the degree of agreement between processed EEG indices and clinical assessments of anesthetic depth as determined by the anesthesiologists' interpretations of acute changes in blood pressure and heart rate as well as the administration, or change to the continuous delivery, of medications at these timepoints. Patient factors (such as burst suppression state or low power EEG conditions from aging brain), surgical conditions (such as use of electrocautery), artifacts (such as electromyography), and anesthesia medications and doses (such as end-tidal concentration of volatile anesthetic or hypnotic infusion dose) that lead to lack of agreement will be explored as well. TRIAL REGISTRATION: Clinical Trials ( ClinicalTrials.gov ), NCT03865316 . Registered on 4 February 2019 - retrospectively registered. SPONSOR: Masimo Corporation.


Asunto(s)
Electroencefalografía , Monitorización Neurofisiológica Intraoperatoria/instrumentación , Anestesia General , Humanos , Estudios Prospectivos
9.
J Cardiothorac Vasc Anesth ; 35(6): 1769-1775, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33446404

RESUMEN

OBJECTIVE: The hypotension prediction index (HPI) is a novel parameter developed by Edwards Lifesciences (Irvine, CA) that is obtained through an algorithm based on arterial pressure waveform characteristics. Past studies have demonstrated its accuracy in predicting hypotensive events in noncardiac surgeries. The authors aimed to evaluate the use of the HPI in cardiac surgeries requiring cardiopulmonary bypass (CPB). DESIGN: Prospective cohort feasibility study. SETTING: Single university medical center. PARTICIPANTS: Sequential adult patients undergoing elective cardiac surgeries requiring CPB between October 1, 2018, and December 31, 2018. INTERVENTIONS: HPI monitor was connected to the patient's arterial pressure transducer. Anesthesiologists and surgeons were blinded to the monitor output. MEASUREMENTS AND MAIN RESULTS: HPI values and hypotensive events were recorded before and after CPB. The primary outcomes were the area under the curve (AUC) of the receiver operating characteristic curve, sensitivity, and specificity of HPI predicting hypotension. The AUC, sensitivity, and specificity for HPI lead time to hypotension five minutes before the event were 0.90 (95% confidence interval [CI]: 0.853-0.949), 84% (95% CI: 77.7-90.5), and 84% (95% CI: 70.9-96.8), respectively. Ten minutes before the event AUC, sensitivity, and specificity for HPI lead time to hypotension were 0.83 (95% CI: 0.750-0.905), 79% (95% CI: 69.8-88.1), and 74% (95% CI: 58.8-89.6), respectively. Fifteen minutes before the hypotensive event AUC, sensitivity, and specificity for HPI lead time to hypotension were 0.83 (95% CI: 0.746-0.911), 79% (95% CI: 68.4-89.0), and 74% (95% CI: 58.8-89.6), respectively. CONCLUSION: HPI predicted hypotensive episodes during cardiac surgeries with a high degree of sensitivity and specificity.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hipotensión , Adulto , Presión Arterial , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Hipotensión/diagnóstico , Hipotensión/etiología , Estudios Prospectivos , Sensibilidad y Especificidad
10.
J Clin Monit Comput ; 35(4): 749-756, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32424516

RESUMEN

Acute hemoglobin desaturation can reflect rapidly decreasing PaO2. Pulse oximetry saturation (SpO2) facilitates hypoxia detection but may not significantly decrease until PaO2 < 80 mmHg. The Oxygen Reserve Index (ORI) is a unitless index that correlates with moderately hyperoxic PaO2. This study evaluated whether ORI provides added arterial desaturation warning in obese patients. This IRB approved, prospective, observational study obtained written informed consent from Obese (body mass index (BMI) kg m-2; 30 < BMI < 40) and Normal BMI (19 < BMI < 25) adult patients scheduled for elective surgery requiring general endotracheal anesthesia. Standard monitors and an ORI sensor were placed. Patient's lungs were pre-oxygenated with 100% FiO2. After ORI plateaued, general anesthesia was induced, and endotracheal intubation accomplished using a videolaryngoscope. Patients remained apneic until SpO2reached 94%. ORI and SpO2 were recorded continuously. Added warning time was defined as the difference between the time to SpO2 94% from ORI alarm start or from SpO2 97%. Data are reported as median; 95% confidence interval. Complete data were collected in 36 Obese and 36 Normal BMI patients. ORI warning time was always longer than SpO2 warning time. Added warning time provided by ORI was 46.5 (36.0-59.0) seconds in Obese and 87.0 (77.0-109.0) seconds in Normal BMI patients, and was shorter in Obese than Normal BMI patients difference 54.0 (38.0-74.0) seconds (p < 0.0001). ORI provided what was felt to be clinically significant added warning time of arterial desaturation compared to SpO2. This added time might allow earlier calls for help, assistance from other providers, or modifications of airway management.Trial registration ClinicalTrials.gov NCT03021551.


Asunto(s)
Oximetría , Oxígeno , Adulto , Humanos , Hipoxia , Obesidad , Estudios Prospectivos
11.
Anesth Analg ; 124(4): 1061-1070, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27984229

RESUMEN

The classic high-dose narcotic-based cardiac anesthetic has been modified to facilitate a fast-track, rapid recovery in the intensive care unit (ICU). Postoperative sedation is consequently now an essential component in recovery of the patient undergoing cardiac surgery. It must facilitate the patient's unawareness of the environment as well as reduce the discomfort and anxiety caused by surgery, intubation, mechanical ventilation, suction, and physiotherapy. Benzodiazepines seem well suited for this role, but propofol, opioids, and dexmedetomidine are among other agents commonly used for sedation in the ICU. However, what is an ideal sedative for this application? When compared with benzodiazepine-based sedation regimens, nonbenzodiazepines have been associated with shorter duration of mechanical ventilation and ICU length of stay. Current sedation guidelines recommend avoiding benzodiazepine use in the ICU. However, there are no recommendations on which alternatives should be used. In postcardiac surgery patients, inotropes and vasoactive medications are often required because of the poor cardiac function. This makes sedation after cardiac surgery unique in comparison with the requirements for most other ICU patient populations. We reviewed the current literature to try to determine if 1 sedative regimen might be better than others; in particular, we compare outcomes of propofol and dexmedetomidine in postoperative sedation in the cardiac surgical ICU.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Dexmedetomidina/administración & dosificación , Hipnóticos y Sedantes/administración & dosificación , Cuidados Posoperatorios/métodos , Propofol/administración & dosificación , Analgésicos Opioides/administración & dosificación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/tendencias , Humanos , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Cuidados Posoperatorios/tendencias
12.
J Cardiothorac Vasc Anesth ; 29(1): 69-75, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25440650

RESUMEN

OBJECTIVE: Because of its invasive nature, debated effect on patient outcome, and the development of alternative hemodynamic monitoring technologies, the intraoperative use of the pulmonary artery catheter (PAC) has significantly decreased. The authors conducted a survey of the members of the Society of Cardiovascular Anesthesiologists (SCA) to assess current use of the PAC and alternative hemodynamic monitoring technologies in patients undergoing cardiac surgery. DESIGN: A survey study. SETTING: Hospitals in North America, Europe, Asia, Australia, New Zealand, and South America. PARTICIPANTS: SCA members in North America, Europe, Asia, Australia, New Zealand, and South America. INTERVENTIONS: The survey was e-mailed by the SCA to roughly 6,000 of its members. MEASUREMENTS AND MAIN RESULTS: The survey was left open for 30 days. Respondents accessed the survey via a secured web-based database. A total of 854 questionnaires were completed. A total of 705 (82.6%) were from North American members. Four hundred twelve of the respondents (48.1%) worked in a private practice setting, while 350 (40.9%) were from an academic practice. A majority of the respondents (57.9%) were from hospitals that performed more than 400 cardiac surgeries a year, a subset of which (29.6%) did more than 800 cases annually. For cases using cardiopulmonary bypass, 583 (68.2%) of the respondents used a PAC more than 75% of the time, while 30 (3.5%) did not use the PAC at all. Ninety-four percent of respondents used transesophageal echocardiography (TEE) as part of the intraoperative monitoring. When not using a PAC, FloTrac/Vigileo was the alternative cardiac monitoring modality in 15.2% of the responses. Similar trends in monitor preferences were seen in off-pump coronary artery bypass grafting and minimally invasive/robotic heart surgery. CONCLUSIONS: The results of this study suggested that a majority of the respondents still prefer to use the PAC for most cardiac surgeries. Subgroup analysis of the data revealed that geographical location, type of practice, and surgeon support played a significant role in the decision to use a PAC. Although most respondents prefer to use TEE as a complimentary tool, TEE also remains the most popular supplemental/alternative hemodynamic monitoring technology.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Cateterismo de Swan-Ganz/métodos , Cateterismo de Swan-Ganz/estadística & datos numéricos , Recolección de Datos , Arteria Pulmonar/cirugía , Recolección de Datos/métodos , Humanos , Arteria Pulmonar/diagnóstico por imagen , Ultrasonografía
13.
J Clin Monit Comput ; 29(4): 467-73, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25267438

RESUMEN

Phenylephrine is often used to treat intra-operative hypotension. Previous studies have shown that the FloTrac cardiac monitor may overestimate cardiac output (CO) changes following phenylephrine administration. A new algorithm (4th generation) has been developed to improve performance in this setting. We performed a prospective observational study to assess the effects of phenylephrine administration on CO values measured by the 3rd and 4th generation FloTrac algorithms. 54 patients were enrolled in this study. We used the Nexfin, a pulse contour method shown to be insensitive to vasopressor administration, as the reference method. Radial arterial pressures were recorded continuously in patients undergoing surgery. Phenylephrine administration times were documented. Arterial pressure recordings were subsequently analyzed offline using three different pulse contour analysis algorithms: FloTrac 3rd generation (G3), FloTrac 4th generation (G4), and Nexfin (nf). One minute of hemodynamic measurements was analyzed immediately before phenylephrine administration and then repeated when the mean arterial pressure peaked. A total of 157 (4.6 ± 3.2 per patient, range 1-15) paired sets of hemodynamic recordings were analyzed. Phenylephrine induced a significant increase in stroke volume (SV) and CO with the FloTrac G3, but not with FloTrac G4 or Nexfin algorithms. Agreement between FloTrac G3 and Nexfin was: 0.23 ± 1.19 l/min and concordance was 51.1%. In contrast, agreement between FloTrac G4 and Nexfin was: 0.19 ± 0.86 l/min and concordance was 87.2%. In conclusion, the pulse contour method of measuring CO, as implemented in FloTrac 4th generation algorithm, has significantly improved its ability to track the changes in CO induced by phenylephrine.


Asunto(s)
Algoritmos , Gasto Cardíaco/efectos de los fármacos , Monitoreo Intraoperatorio/métodos , Fenilefrina/uso terapéutico , Arteria Radial/patología , Procesamiento de Señales Asistido por Computador , Anciano , Presión Sanguínea , Femenino , Frecuencia Cardíaca , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Volumen Sistólico
14.
Circulation ; 127(15): 1576-84, 2013 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-23513068

RESUMEN

BACKGROUND: Cardiac surgery is associated with a high risk of cardiovascular and other complications that translate into increased mortality and healthcare costs. This retrospective study was designed to determine whether the perioperative use of dexmedetomidine could reduce the incidence of complications and mortality after cardiac surgery. METHODS AND RESULTS: A total of 1134 patients who underwent coronary artery bypass surgery and coronary artery bypass surgery plus valvular or other procedures were included. Of them, 568 received intravenous dexmedetomidine infusion and 566 did not. Data were adjusted with propensity scores, and multivariate logistic regression was used. The primary outcomes measured included mortality and postoperative major adverse cardiocerebral events (stroke, coma, perioperative myocardial infarction, heart block, or cardiac arrest). Secondary outcomes included renal failure, sepsis, delirium, postoperative ventilation hours, length of hospital stay, and 30-day readmission. Dexmedetomidine use significantly reduced postoperative in-hospital (1.23% versus 4.59%; adjusted odds ratio, 0.34; 95% confidence interval, 0.192-0.614; P<0.0001), 30-day (1.76% versus 5.12%; adjusted odds ratio, 0.39; 95% confidence interval, 0.226-0.655; P<0.0001), and 1-year (3.17% versus 7.95%; adjusted odds ratio, 0.47; 95% confidence interval, 0.312-0.701; P=0.0002) mortality. Perioperative dexmedetomidine therapy also reduced the risk of overall complications (47.18% versus 54.06%; adjusted odds ratio, 0.80; 95% confidence interval, 0.68-0.96; P=0.0136) and delirium (5.46% versus 7.42%; adjusted odds ratio, 0.53; 95% confidence interval, 0.37-0.75; P=0.0030). CONCLUSION: Perioperative dexmedetomidine use was associated with a decrease in postoperative mortality up to 1 year and decreased incidence of postoperative complications and delirium in patients undergoing cardiac surgery. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov. Unique identifier: NCT01683448.


Asunto(s)
Agonistas de Receptores Adrenérgicos alfa 2/uso terapéutico , Procedimientos Quirúrgicos Cardíacos , Dexmedetomidina/uso terapéutico , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Lesión Renal Aguda/prevención & control , Agonistas de Receptores Adrenérgicos alfa 2/administración & dosificación , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Catecolaminas/metabolismo , Delirio/epidemiología , Delirio/etiología , Delirio/prevención & control , Dexmedetomidina/administración & dosificación , Femenino , Cardiopatías/epidemiología , Cardiopatías/etiología , Cardiopatías/prevención & control , Mortalidad Hospitalaria , Registros de Hospitales , Humanos , Hipnóticos y Sedantes/administración & dosificación , Hipnóticos y Sedantes/uso terapéutico , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/etiología , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/prevención & control , Readmisión del Paciente/estadística & datos numéricos , Atención Perioperativa , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Respiración Artificial/estadística & datos numéricos , Estudios Retrospectivos , Sepsis/epidemiología , Sepsis/etiología , Sepsis/prevención & control , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
15.
Cureus ; 16(4): e57908, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38725749

RESUMEN

Quality improvement (QI) projects are essential components of graduate medical education and healthcare organizations to improve patient outcomes. We systematically reviewed the literature on QI projects in anesthesiology graduate medical education programs to assess whether these projects are leading to publications. A literature search was conducted in July 2023, using PubMed, Embase, and the Central Register of Controlled Trials (CENTRAL) for articles describing QI initiatives originating within the United States and applicable to anesthesiology residency training programs. The following data were collected: intervention(s), sample size (number of participants or events), outcome metric(s), result(s), and conclusion(s). One hundred and fifty publications were identified, and 31 articles met the inclusion criteria. A total of 2,259 residents and 72,889 events were included in this review. Educational modalities, such as simulation, training sessions, or online curricula, were the most prevalent interventions in the included studies. Pre-intervention and post-intervention assessments were the most common outcome metrics reported. Our review of the literature demonstrates that few QI projects performed within anesthesiology training programs lead to published manuscripts. Further research should aim at increasing the impact of required QI projects within the sponsoring institution and specialty.

16.
Cureus ; 16(6): e61821, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38975435

RESUMEN

American Board of Anesthesiology (ABA) diplomates who pursue clinical fellowship training in pain medicine may be better suited to lead scholarly projects and serve as first authors of publications in peer-reviewed journals given their additional training and clinical expertise. The primary aim of this study was to determine whether ABA certification in pain medicine is associated with a greater number of peer-reviewed publications. The secondary aim included assessments of whether pain medicine fellowship training is associated with a higher publication rate (publications per year) or publication in a larger number of peer-reviewed journals. A literature search was conducted in December 2023 using the Scopus database for publications related to anesthesiology and pain medicine in the United States between 2013 and 2023. First authors identified through the search were then individually searched within the ABA physician directory. The following data were collected: author name and identification number, year of publication, publication type (article or review), year of primary anesthesiology certification, and year of fellowship, if applicable. This study identified 9,612 publications and 6,924 unique first authors. Pain medicine fellowship training was associated with a statistically significant increase (p-value < 0.001) in the number of publications (0.546; 95% confidence interval {CI}, 0.386-0.707), publications per year (0.140; 95% CI, 0.121-0.159), and publication in a larger number of peer-reviewed journals (0.256; 95% CI, 0.182-0.330) in regression models adjusted for the number of years from certification. This query of the Scopus database and ABA physician directory indicates that pain medicine fellowship training is associated with statistically significant increases in research productivity, as defined by the number of publications, publications per year, or the number of publications in peer-reviewed journals. However, these increases in research output would not lead to a marked increase in scholarship productivity to justify pursuing a fellowship for this purpose.

18.
PLoS One ; 16(7): e0254399, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34252138

RESUMEN

BACKGROUND: Respiratory heat exchange is an important physiological process occurring in the upper and lower respiratory tract and is usually completed when inspired gases reach the alveoli. Animal and human studies demonstrated that heat exchange can be modulated by altering pulmonary ventilation and perfusion. The purpose of this study was to examine the effect of acute ventilation-perfusion (V/Q) mismatch on respiratory heat exchange. In clinical practice, monitoring respiratory heat exchange might offer the possibility of real-time tracking of acute V/Q-mismatch. METHODS: In 11 anesthetized, mechanically ventilated pigs, V/Q-mismatch was established by means of four interventions: single lung ventilation, high cardiac output, occlusion of the left pulmonary artery and repeated whole-lung lavage. V/Q-distributions were determined by the multiple inert gas elimination technique (MIGET). Respiratory heat exchange was measured as respiratory enthalpy using the novel, pre-commercial VQm™ monitor (development stage, Rostrum Medical Innovations, Vancouver, CA). According to MIGET, shunt perfusion of low V/Q compartments increased during single lung ventilation, high cardiac output and whole-lung lavage, whereas dead space and ventilation of high V/Q compartments increased during occlusion of the left pulmonary artery and whole-lung lavage. RESULTS: Bohr dead space increased after pulmonary artery occlusion and whole-lung lavage, venous admixture increased during single lung ventilation and whole-lung lavage, PaO2/FiO2 was decreased during all interventions. MIGET confirmed acute V/Q-mismatch. Respiratory enthalpy did not change significantly despite significant acute V/Q-mismatch. CONCLUSION: Clinically relevant V/Q-mismatch does not impair respiratory heat exchange in the absence of additional thermal stressors and may not have clinical utility in the detection of acute changes.


Asunto(s)
Calor , Perfusión , Respiración Artificial , Respiración , Animales , Modelos Animales de Enfermedad , Hemodinámica , Espectrometría de Masas , Oxígeno/metabolismo , Presión Parcial , Porcinos
19.
MethodsX ; 7: 100979, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32670807

RESUMEN

Pigs are often used for experimental models of cardiogenic shock, cardiac arrest or acute lung injury with veno-arterial (VA) or veno-venous (VV) extracorporeal membrane oxygenation (ECMO) implementation. Percutaneous (as opposed to surgical) cannulation in experimental models has potential advantages, including, less surgical trauma or stressful stimuli and less bleeding complications when compared to open chest cannulation. However, pig anatomy can also be a challenge because of the deep location and angled anatomy of the femoral artery. The Seldinger technique and the use of a percutaneous cannulation kit is feasible in pigs. Summarized here we present (Graphical Abstract):•Percutaneous ECMO cannulation method for non-cardiac surgeon.•Establishment of this simple and rapid methods for pig experimental models.•Predictable complications of this method.