Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Occup Environ Hyg ; 18(12): 541-546, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34637686

RESUMEN

This in vitro study was aimed to assess the efficacy of dry steam in inactivating Human Coronavirus OC43 (HCoV-OC43) as surrogate of SARS-CoV-2, Human Influenza Virus A/H1N1/WSN/33 and Echovirus 7 on stainless steel, polypropylene, and cotton. The virus models were chosen on the basis of their transmission route and environmental resistance. Tests were carried out under a laminar flow cabinet, where two panels of each material were contaminated with a viral suspension. The inocula were left to dry and then the virus on untreated panel (control) was collected by swabbing in order to determine the initial titer. The other panel was treated using a professional vacuum cleaner equipped with a dry steam generator. Dry steam is generated in a boiler where tap water is heated up to 155 °C at 5.5 bar pressure and then during the passage along the flexible hose the temperature decreases to a value between 100 °C and 110 °C at the output. The dry steam was applied for four sec with a window wiper on metal and plastic panels or a brush covered by a microfiber cap on cotton, simulating the steam application during routine cleaning. After the treatment, infectious virus possibly remained on the surface was collected following the same swabbing procedure applied for controls. HCoV-OC43 and Echovirus 7 were titrated by end-point method on HCT-8 line cells and Vero cells, respectively, while Human Influenza Virus was quantified by plaque reduction assay on MDCK cells. Dry steam resulted effective against the three viruses on all tested materials, achieving a mean Log10 reduction factor ≥4 in viral titer of treated samples compared with controls according to UNI EN 14476:2019. Thus, dry steam may be proposed as an ease to use, effective, fast, and nontoxic alternative to chemicals for surface disinfection without damaging materials. Therefore, this device could be employed not only in healthcare facilities but also in occupational, domestic, and community settings, with advantages for environment and human health.


Asunto(s)
COVID-19 , Subtipo H1N1 del Virus de la Influenza A , Gripe Humana , Animales , Chlorocebus aethiops , Desinfección , Enterovirus Humano B , Humanos , SARS-CoV-2 , Vapor , Células Vero
2.
Antibodies (Basel) ; 12(4)2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38131799

RESUMEN

Factors associated with SARS-CoV-2 infection risk are still debated. This case-control study aims to investigate the possible relationship between SARS-CoV-2 infection, evaluated through antibody response, and the main sociodemographic, occupational, clinical-anamnestic, and biochemical factors in a population of Modena province (Northern Italy), mainly workers. Both workers who voluntarily joined the screening campaign proposed by companies and self-referred individuals who underwent serological testing were enrolled. Subjects with antibody positivity were recruited as cases (n = 166) and subjects tested negative (n = 239) as controls. A questionnaire on sociodemographic, occupational, and clinical data was administered through telephone interviews. Serum zinc/iron/copper/chromium/nickel, vitamins D/B12, folates, triglycerides, and LDL/HDL/total cholesterol were measured. Cases lived more often in urban areas (61.8% vs. 57%). Cases and controls did not differ significantly by working macrocategories, but the percentage of workers in the ceramic sector was higher among cases. Low adherence to preventive measures in the workplace was more frequent among seropositives. Folate concentration was significantly lower among cases. Therefore, adequate folate levels, living in rural areas, and good adherence to preventive strategies seem protective against infection. Workers in the ceramic sector seem to be at greater risk; specific factors involved are not defined, but preventive interventions are needed.

3.
Artículo en Inglés | MEDLINE | ID: mdl-32842654

RESUMEN

The formation of potentially carcinogenic N-nitrosamines, associated with monochloramine, requires further research due to the growing interest in using this biocide for the secondary disinfection of water in public and private buildings. The aim of our study was to evaluate the possible formation of N-nitrosamines and other toxic disinfection by-products (DBPs) in hospital hot water networks treated with monochloramine. The effectiveness of this biocide in controlling Legionella spp. contamination was also verified. For this purpose, four different monochloramine-treated networks, in terms of the duration of treatment and method of biocide injection, were investigated. Untreated hot water, municipal cold water and, limited to N-nitrosamines analysis, hot water treated with chlorine dioxide were analyzed for comparison. Legionella spp. contamination was successfully controlled without any formation of N-nitrosamines. No nitrification or formation of the regulated DBPs, such as chlorites and trihalomethanes, occurred in monochloramine-treated water networks. However, a stable formulation of hypochlorite, its frequent replacement with a fresh product, and the routine monitoring of free ammonia are recommended to ensure a proper disinfection. Our study confirms that monochloramine may be proposed as an effective and safe strategy for the continuous disinfection of building plumbing systems, preventing vulnerable individuals from being exposed to legionellae and dangerous DBPs.


Asunto(s)
Cloraminas , Desinfectantes , Purificación del Agua , Cloraminas/farmacología , Desinfectantes/farmacología , Desinfección , Humanos , Agua , Microbiología del Agua
4.
Int J Infect Dis ; 91: 174-176, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31707135

RESUMEN

Three cases of pneumonia caused by Legionella pneumophila serogroup 1 (Lp1) in immunosuppressed patients with repeated hospitalization were suspected as a healthcare-associated cluster. The environmental investigation did not reveal the presence of legionellae in the hospital patient rooms. Water samples collected from the homes of two patients were also negative for Legionella spp. In the absence of environmental strains potentially involved in the infections, we proceeded to genotype environmental Lp1 strains isolated in the hospital during routine water sampling during the decade 2009-2019 and recovered after long-term storage at -20°C. These 'historical' strains exhibited a high grade of similarity and stability over time, regardless of the disinfection systems. The different molecular profiles shown among the clinical and environmental strains excluded a nosocomial outbreak. The study suggests that the application of molecular typing may be a useful tool to discriminate hospital vs community-acquired cases, mostly for severely immunosuppressed patients in whom the symptomatology could be insidious and the incubation period could be prolonged. Moreover, the genotyping allowed us to exclude any link between the cases.


Asunto(s)
Técnicas de Genotipaje , Legionella pneumophila/aislamiento & purificación , Enfermedad de los Legionarios/microbiología , Anciano , Anciano de 80 o más Años , Infección Hospitalaria/microbiología , Brotes de Enfermedades , Femenino , Humanos , Terapia de Inmunosupresión , Legionella pneumophila/clasificación , Legionella pneumophila/genética , Enfermedad de los Legionarios/epidemiología , Enfermedad de los Legionarios/terapia , Masculino , Persona de Mediana Edad , Tipificación Molecular , Serogrupo
5.
Artículo en Inglés | MEDLINE | ID: mdl-32213901

RESUMEN

Many disinfection treatments can be adopted for controlling opportunistic pathogens in hospital water networks in order to reduce infection risk for immunocompromised patients. Each method has limits and strengths and it could determine modifications on bacterial community. The aim of our investigation was to study under real-life conditions the microbial community associated with different chemical (monochloramine, hydrogen peroxide, chlorine dioxide) and non-chemical (hyperthermia) treatments, continuously applied since many years in four hot water networks of the same hospital. Municipal cold water, untreated secondary, and treated hot water were analysed for microbiome characterization by 16S amplicon sequencing. Cold waters had a common microbial profile at genera level. The hot water bacterial profiles differed according to treatment. Our results confirm the effectiveness of disinfection strategies in our hospital for controlling potential pathogens such as Legionella, as the investigated genera containing opportunistic pathogens were absent or had relative abundances ≤1%, except for non-tuberculous mycobacteria, Sphingomonas, Ochrobactrum and Brevundimonas. Monitoring the microbial complexity of healthcare water networks through 16S amplicon sequencing is an innovative and effective approach useful for Public Health purpose in order to verify possible modifications of microbiota associated with disinfection treatments.


Asunto(s)
Desinfección , Hospitales , Microbiota , Microbiología del Agua , Purificación del Agua , Abastecimiento de Agua , Humanos , Legionella
6.
Am J Infect Control ; 40(3): 279-81, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21741121

RESUMEN

BACKGROUND: We report the results of 1-year application of monochloramine to control Legionella pneumophila contamination in a hospital hot water distribution system. METHODS: In the main building of the hospital, a device continuously distributing monochloramine was installed. Legionella pneumophila and Pseudomonas spp contamination was followed in comparison with 2 other water networks in the same building using chlorine dioxide. RESULTS: Monochloramine significantly reduced the number of contaminated sites compared with baseline (from 97.0% to 13.3%, respectively), chlorine dioxide device I (from 100% to 56.7%, respectively), and device II (from 100% to 60.8%, respectively). No positive sample exceeded 10(4) colony-forming units/L versus 59.4% at baseline. CONCLUSION: Monochloramine could represent a good alternative to chlorine dioxide in controlling legionellae contamination in public and private buildings.


Asunto(s)
Cloraminas/farmacología , Infección Hospitalaria/prevención & control , Desinfectantes/farmacología , Desinfección/métodos , Legionella pneumophila/efectos de los fármacos , Enfermedad de los Legionarios/prevención & control , Microbiología del Agua , Compuestos de Cloro/farmacología , Recuento de Colonia Microbiana , Hospitales , Humanos , Legionella pneumophila/aislamiento & purificación , Óxidos/farmacología , Pseudomonas/efectos de los fármacos , Pseudomonas/aislamiento & purificación , Infecciones por Pseudomonas/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA