RESUMEN
Diagnosing cardiac masses, especially those related to cardiac tumors, is often challenging in clinical practice. Though myxomas are the most common and well-known benign cardiac tumors, other rare and often-neglected tumors can be difficult to diagnose. In this case report, the authors describe a left ventricular cardiac mass with unique and striking imaging features.
Asunto(s)
Neoplasias Cardíacas , Mixoma , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/cirugía , Mixoma/diagnóstico por imagen , Mixoma/cirugía , Diagnóstico DiferencialRESUMEN
Nowadays, the diagnosis of cardiac myxomas (CM), particularly the histological types, remains a challenge. Two-dimensional (2D) transthoracic (TT) and transesophageal (TEE) echocardiography (ECHO) represent the first steps in the imaging pathway. 3D ECHO, implemented in imaging practice, appears to be an emerging diagnostic technique that overcomes some of the limitations of 2D ECHO while integrating the information provided by magnetic resonance (MRI). However, its role in the imaging arena is still debatable. Analyzing 17 myxomas in 13 patients, the study uncovers a diverse anatomical spectrum. Classical CM morphology is a minority, with most myxomas being sessile and originating from unexpected locations (right ventricular outflow tract and left atrial appendage). Texture and size variations are also noted. Comparing imaging, 2D TEE outperforms 2D TT in visualizing anatomical features, especially attachment types. 3D TEE confirms 2D TT findings and offers more detailed assessments, identifying peduncles missed in four cases by 2D TEE. Two small recurrent myxomas were exclusively detected by 3D TEE, not by 2D TEE or MRI. Two patients have papillary myxomas, one has an embolism. Another patient with a solid myxoma also suffers an embolism, with a clot found at the apex during surgery. Our study showed that CM has a wide anatomical spectrum beyond the typical features, making the diagnosis challenging. Therefore, a multimodality imaging approach is essential for distinguishing CM from other cardiac masses and differentiating myxoma histological types. These findings stress the importance of incorporating 3D ECHO alongside other imaging techniques for a comprehensive evaluation.
RESUMEN
After heart failure, infectious endocarditis is the second leading cause of death in patients with prosthetic valves. Aortic pseudoaneurysms are a serious complication of infective endocarditis in mechanical or bioprosthetic aortic prostheses. Diagnostic and management challenges are posed by aortic pseudoaneurysms. In these cases, a multi-modality imaging approach with a heart team is recommended. We described two cases of aortic pseudoaneurysms that developed as a result of infective endocarditis. The first case involved a TAVI patient who developed infective endocarditis as a result of diabetic foot complications. Because traditional echocardiography and computed tomography failed to show the anatomy of the lesion, we used 3D printing to show the anatomy, extension of the pseudoaneurysm, and proximity to the right coronary artery. The second case involved a patient who underwent Bentall's surgery with an aortic root and mechanical aortic valve and later developed infective endocarditis complicated by pseudoaneurysms. In this case, 3D printing was used for preoperative surgical planning.
Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Endocarditis/diagnóstico , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/cirugía , Impresión Tridimensional , Imagen Multimodal/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversosRESUMEN
The interaction between the implanter team and the imager team is critical to the success of transcatheter native mitral valve replacement (TMVR), a novel interventional procedure in the therapeutic arsenal for mitral regurgitation. This imaging scenario necessitates the addition of a new dedicated professional figure, dubbed "the interventional imager," with specific expertise in structural heart disease procedures. As its clinical application grows, knowledge of the various imaging modalities used in the TMVR procedure is required for the interventional imager and beneficial for the interventional implanter team. The purpose of this review is to describe the key steps of the procedural imaging pathway in TMVR using the Tendyne mitral valve system, with an emphasis on echocardiography. Pre-procedure cardiac multi-modality imaging screening and planning for TMVR can determine patient eligibility based on anatomic features and measurements, provide measurements for appropriate valve sizing, plan/simulate the access site, catheter/sheath trajectory, and pros- thesis positioning/orientation for correct deployment and predict the risks of potential procedural complications and their likelihood of success. Step-by-step echocardiographic TMVR intraoperative guidance includes: apical access assessment; support for catheter/sheath localization, trajectory and positioning, valve positioning and clocking; post deployment: correct clocking; hemodynamic assessment; detection of perivalvular leakage; obstruction of the left ventricular outlet tract; complications. Knowledge of the multimodality imaging pathway is essential for interventional imagers and critical to the procedure's success.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , EcocardiografíaRESUMEN
The incidence of right-sided infective endocarditis (RSIE) is steadily increasing and it has been reported to be associated with high risk of embolic events (EE). Aim of our study was to identify the clinical characteristics of patients with RSIE complicated by PE. Indeed, the identification of patients at high risk of significant PE who will benefit from a more aggressive therapeutic strategy may improve the prognosis. From January 2015 to September 2020, 176 patients (Pts) in 6 centers were found to have definite RSIE complicated by PE. Advanced imaging for PE including computed tomography pulmonary angiography (CTPA) was performed in 28 pts (16%) who represent our study group (24 male, mean age 50.6 ±18.29 years). They all underwent transesophageal echocardiography (TEE), in 12 cases (43%) also three-dimensional (3D) TEE, and 27 patients (99%) had both TEE and transthoracic echocardiography (TTE). A total of 53 vegetations (V) were detected. In 18 pts (64%) two or more vegetations were found. Native tricuspid valve was the most frequently involved valve (38 V, 71.7%), followed by catheter (5 V, 9.4%), tricuspid valve prosthesis (4 V, 7.5%), chordae and papillary muscle (2 V, 3.8%) and one vegetation (9%) in each of the following: pulmonic valve, inferior vena cava, eustachian valve, and right atrium. The most common location for vegetations was the anterior leaflet of the tricuspid valve (19 V, 35.8 %) followed by the posterior leaflet (11 V, 20.8%). The most common vegetations morphology was raceme-like shaped (35.8%). Staphylococcus aureus (S. aureus) was the most common causative pathogen (14 pts, 50%). The incidence of PE was very high in patients with vegetation length above 1.5 cm (median 17.6±6.5 mm by TEE). Our results suggest that a routine CTPA should be advised in the presence of vegetations larger than 1.5 cm and with S. aureus infection. This behavior would identify patients at high risk of PE who will benefit from a more aggressive therapeutic strategy, leading to an improvement in the prognosis. Further prospective studies are required to better confirm our hypothesis.
Asunto(s)
Endocarditis , Embolia Pulmonar , Infecciones Estafilocócicas , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Endocarditis/complicaciones , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/epidemiología , Staphylococcus aureusRESUMEN
Mucopolysaccharidoses, a rare inherited disorder of lysosomal storage, account for less than 0.1% of all genetic diseases. The penetrance is highly variable and clinically it varies from severe fetal-neonatal forms to attenuated diseases diagnosed in adult individuals. The majority of the patients have been reported to show cardiac abnormalities since pediatric age, however, there is a minority of patients with attenuated disease diagnosed in the adolescent and adult age. The haematopoietic stem cell transplantation and enzyme replacement therapy are the current therapies for these disorders. Thanks to these treatments, Mucopolysaccharidoses patients live longer than in the past. Even though enzyme replacement therapy has been demonstrated to reduce left ventricular mass in patients with cardiomyopathy, the efficacy on valve abnormalities has not been clearly demonstrate yet. Furthermore, thanks to the current therapy, to better understanding and to the advent on new technologies, an increasing number of adolescent and adult patients diagnosed with MPS are followed up in the adult echocardiographic laboratory. Indeed, a systematic descriptive study describing the echocardiographic features of valvular involvement and their evolution in adolescent and adult patients lacks of medical literature and this was the aim of our investigation. Our results showed that all the valves are affected, mainly the mitral valve with a higher prevalence compared to the pediatric age. The echocardiographic features of MPS differs from other valvular disease of adolescent and adult age, and knowing them can avoid misdiagnosis. Our observations also suggest that the progression of cardiac involvement slows after the initiation of the therapy in our group of age. Further studies on larger population are required to confirm our results.
Asunto(s)
Cardiopatías Congénitas , Insuficiencia de la Válvula Mitral , Mucopolisacaridosis , Adolescente , Niño , Ecocardiografía , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Mucopolisacaridosis/complicaciones , Mucopolisacaridosis/diagnóstico por imagen , Mucopolisacaridosis/epidemiologíaRESUMEN
Stuck valve is a very rare and severe complication that occurs in mechanical valve replacement patients with ineffective anticoagulation. However, with COVID-19 restriction measures, it became challenging to regularly assess INR to make sure it falls within the target therapeutic range to prevent this complication. We present a series of 10 patients who either underwent transthoracic echocardiography for a suspected stuck valve or were seen at the outpatient valve clinic with the residual consequences of a stuck valve during the COVID-19 restriction measures in our institute. Stuck prosthetic valves incident has increased significantly during this period, particularly those in the mitral position for which urgent replacement and prolonged hospitalization were necessary. Particularly with the COVID-19 restrictions in place, these cases highlight the need for physicians to be aware of the dramatic increase in the incidence of stuck prosthetic valves in patients on chronic warfarin therapy.
Asunto(s)
COVID-19 , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anticoagulantes/uso terapéutico , Ecocardiografía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , IncidenciaRESUMEN
INTRODUCTION: Microbubbles (MBs) or cavitation is high-velocity, echo-bright findings present during the closing or opening of a mechanical valve (MVP). Cavitation bubble growth or gas emboli are less frequently described. We evaluated the hemodynamic parameters involved in the formation of gas emboli and the impact of gas emboli on requests for additional investigations. METHODS AND RESULTS: Transthoracic echocardiographic studies (TTE) of 57 patients (31 males, mean age 46.8 ± 13.8 years) with gas emboli were evaluated after heart valve replacement surgery. The majority (72%, n = 42) had a mitral or combined mitral/aortic MVP, with 28% (n = 16) an aortic MVP. The last TTE with and without gas emboli were considered for the same patient and the no emboli group was the control group (42 patients). The patient's blood pressure (BP) and heart rate (HR) were available for each TTE. Comparing the two TTEs, the systolic and diastolic BP, transmitral and aortic gradients, and left ventricular ejection fraction were similar but the HR (80.9 ± 18.7 vs 72.5 ± 13.9 bpm, P = .02) was significantly higher in the group with gas emboli. A TEE was performed 52 times in 27 patients, due to gas emboli, with one case positive for thrombus/vegetation. For 19 patients, a brain CT was requested. In two patients, the indication for the brain CT was gas emboli but the result was negative. CONCLUSION: Gas emboli are frequently present and associated to an increased HR. They can cause the misdiagnosis of endocarditis or thrombus formation with significant additional requests for diagnostic examinations.
Asunto(s)
Prótesis Valvulares Cardíacas , Microburbujas , Adulto , Ecocardiografía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular IzquierdaRESUMEN
Masked hypertension (MH) is traditionally diagnosed with 24-hour ambulatory blood pressure monitoring (24-ABPM). This is relatively costly and could cause discomfort during the night. We studied the validity of daytime ABP (DT-ABPM) in young National Guard soldiers and determined the prevalence in comparison to the standard 24-ABPM. A prospective study of 196 soldiers aged 21-50 years, without a history of hypertension or antihypertensive medication use. Each participant was fitted with a 12h-ABPM. Patients were diagnosed with MH if the office blood pressure (OBP) was <140/90 mmHg and the average DT-ABPM was ≥135/85 mmHg. By pairing the average OBP with the 12 h-ABPM, the prevalence of MH was estimated as 18/196 (9.2%), the SBP MH (systolic blood pressure) of 8.2% and the DPB MH (diastolic blood pressure) of 3.1%. When we compared the daytime prevalence with the 24 h-ABPM, and the average OBP, the prevalence of MH was 29/196 (14.8%). No statistically significant difference was noted (kappa=0.74; 95% CI: 0.59 to 0.88). We conclude that DT-ABPM is a good method and convenient to detect MH, with no statistically significant difference when compared to the 24 h-ABPM. The prevalence of MH in young healthy soldiers was unexpectedly high.
Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial/métodos , Hipertensión Enmascarada/diagnóstico , Hipertensión Enmascarada/fisiopatología , Adulto , Presión Sanguínea/fisiología , Monitoreo Ambulatorio de la Presión Arterial/estadística & datos numéricos , Humanos , Masculino , Hipertensión Enmascarada/epidemiología , Persona de Mediana Edad , Personal Militar/estadística & datos numéricos , Prevalencia , Estudios Prospectivos , Factores de TiempoRESUMEN
We report a case of a recurrence of 5 cardiac myxomas in both atria with atypical anatomical features difficult to image. Although a multimodality imaging was performed, three-dimensional echocardiography (3DE) was the only technique able to correctly identify all the recurrences and the anatomical characteristics of the myxomas. MRI detected the blood supply of the mass but even after careful review was able to identify only 4 of the 5 lesions. Even though it was already reported the usefulness of 3DE to better delineate the site of attachment of cardiac tumors, it was never reported its sensibility in the setting of multiple myxomas; this case highlights the ability of the 3DE in this challenging scenario and its potential for being considered the key adjunctive modality for the anatomy when advanced surgical plan is required.
Asunto(s)
Ecocardiografía Tridimensional/métodos , Atrios Cardíacos/patología , Mixoma/diagnóstico por imagen , Adulto , Femenino , Neoplasias Cardíacas/patología , Humanos , Imagen por Resonancia Magnética/métodos , Mixoma/cirugía , Recurrencia Local de Neoplasia/cirugía , Reoperación/métodos , Resultado del TratamientoRESUMEN
We report a case of a 55-year-old male admitted for cardiogenic embolic ischemic stroke work up. A transesophageal (TE) echocardiography (E) with contrast study to rule out patent foramen ovale (PFO) was performed; two-dimensional (2D) analysis did not detect any bubbles passage during Valsalva manoeuvre in the standard 2D cross sectional planes; further real time three-dimensional (3D) TEE imaging revealed passage of bubbles in the left atrium (LA) by both real-time 3DTEE imaging and by the 2D unconventional cross-sectional planes allowed by 3DTEE imaging. Even though 2DTEE is considered to be the gold standard modality for diagnosing PFO, it has some limitations. It has never been reported about usefulness of 3DTEE in PFO imaging. Even in the presence of only a report, our case suggests that 3DE could have an additional value and will compliment 2D imaging in PFO assessment.
Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/instrumentación , Foramen Oval Permeable/diagnóstico , Medios de Contraste/administración & dosificación , Ecocardiografía Transesofágica/métodos , Accidente Cerebrovascular Embólico/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Humanos , Accidente Cerebrovascular Isquémico/etiología , Masculino , Microburbujas , Persona de Mediana Edad , Maniobra de Valsalva/fisiologíaRESUMEN
Cardiovascular emergencies represent life-threatening conditions requiring a high index of clinical suspicion. In an emergency scenario, a simple stepwise biomarker/imaging diagnostic algorithm may help prompt diagnosis and timely treatment along with related improved outcomes. This article describes several clinical cases of cardiovascular emergencies, such as coronary stent thrombosis-restenosis, takotsubo syndrome, acute myocarditis, massive pulmonary embolism, type A acute aortic dissection, cardiac tamponade, and endocarditis.
Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Enfermedades Cardiovasculares , Urgencias Médicas/clasificación , Tratamiento de Urgencia/métodos , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/terapia , HumanosRESUMEN
A 39-year-old woman underwent heart transplantation (HTx) for advanced heart failure. The donor was a 36-year-old young woman without past medical history. The first day after HTx, T-waves changes were noted. Echocardiography revealed akinesia/dyskinesia of all basal segments of the two ventricles. Coronary catheterization plus biopsy were done 7 days later showing no coronary obstruction, no rejection and complete recovery of wall motion abnormalities on echocardiogram, suggesting biventricular inverted takotsubo syndrome (TTS). This is a case of TTS during the first day after HTx, with completely denervated heart but because of the inotropic drug support it still represents a target for catecholamine-induced cardiac dysfunction.
Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Cardiomiopatía de Takotsubo/etiología , Médula Suprarrenal/metabolismo , Adulto , Cardiotónicos/uso terapéutico , Catecolaminas/sangre , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/fisiopatología , Estrés Fisiológico , Cardiomiopatía de Takotsubo/diagnóstico por imagen , Cardiomiopatía de Takotsubo/fisiopatologíaRESUMEN
We describe a case of a left atrial myxoma atypical for its anatomical features and site of attachment. Although an initial multimodality imaging was performed, the diagnosis of myxoma was possible only by three dimensional echocardiography (3DE) which was able to identify the pedicle and the attachment at the base of the interatrial septum, close to the origin of right inferior pulmonary vein. In fact the 3DE can electronically section the structures and obtain unique planes useful in visualizing correctly the anatomical features of the myxomas and as a result, it facilitates the surgical decision planning. Even the anatomical appearance was uncommon at surgery and the diagnosis could be confirmed only by pathology. This case highlights the diagnostic ability of the 3DE in similar challenging scenarios.
Asunto(s)
Tabique Interatrial/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Neoplasias Cardíacas/diagnóstico por imagen , Mixoma/diagnóstico por imagen , Diagnóstico Diferencial , Ecocardiografía Tridimensional , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Tomografía Computarizada por Rayos XRESUMEN
OBJECTIVE: Our aim was to evaluate left ventricular (LV) mechanics by using speckle tracking echocardiography (STE) in asymptomatic patients with abnormal origin of the left main coronary artery from the pulmonary trunk (ALCAPA), late after successful repair, in the presence of LV ejection fraction (EF) >50%. METHODS: We studied 30 ALCAPA patients (median age 4 years, range 1-25 years, NYHA class I, LVEF >50%) and 16 healthy age- and sex-matched controls (median age 5 years, range 1-25 years). All underwent standard echocardiographic evaluation and STE. RESULTS: LV dimensions and LVEF (63.6 ± 8.2% vs. 64.1 ± 5.1%, p = 0.826) were not different between patients and controls. Diastolic parameters were significantly abnormal in our patients versus controls (E/e' average: 11.9 ± 5.8 vs. 6.6 ± 3.0, p = 0.0014). Global LV longitudinal strain was significantly lower in ALCAPA patients versus controls (-17.6 ± 3.5% vs. -23.4 ± 3.1%, p < 0.0001). LV torsion (9.1 ± 4.9° vs. 11.9 ± 3.3°, p = 0.046) was significantly impaired in ALCAPA patients. CONCLUSIONS: After successful repair in asymptomatic ALCAPA patients, despite an LVEF >50%, diastolic function, LV longitudinal deformation and LV torsion remain impaired. We suggest including a detailed study of the diastolic function and cardiac mechanics in the clinical follow-up of these patients to identify the subgroup of patients at higher risk.
Asunto(s)
Síndrome de Bland White Garland/fisiopatología , Volumen Sistólico , Disfunción Ventricular Izquierda/fisiopatología , Adolescente , Adulto , Síndrome de Bland White Garland/diagnóstico por imagen , Síndrome de Bland White Garland/cirugía , Niño , Preescolar , Ecocardiografía/métodos , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Análisis Multivariante , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto JovenRESUMEN
Intermittent malfunction of a mechanical valve prosthesis is a rare condition that carries serious clinical implications. It results from the periodic entrapment of a prosthetic disk in either an open or closed position leading to transient intravalvular regurgitation or obstruction to flow. The intermittent nature of the malfunction poses a diagnostic challenge, particularly in the era of digital echocardiography. In this manuscript, we describe the Doppler and two-dimensional echocardiographic findings in a patient with intermittent prosthetic mitral valve malfunction.
Asunto(s)
Ecocardiografía/métodos , Análisis de Falla de Equipo/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Falla de PrótesisRESUMEN
Background: Aortic coarctation (CoA) is a congenital heart disease affecting 5-8% of patients, with long-term complications persisting despite successful correction. Stress echocardiography (SE) is increasingly used for evaluating cardiac function under stress, yet its role in repaired CoA remains under-explored. Objective: This study aimed to assess the predictive value of SE and myocardial strain in repaired CoA patients with a history of hypertension without significant gradients or with borderline gradients at rest. Methods: Between June 2020 and March 2024, we enrolled 35 consecutive CoA patients with successful repairs and either a history of hypertension or borderline Doppler gradients. Baseline and peak exercise echocardiographic measurements, including left ventricular mass index (LVMi) and global longitudinal strain (LVGLS), were recorded. Patients were followed for up to 4 years. Results: At baseline, the positive SE group had higher systolic blood pressure (SBP) and diastolic blood pressure (DBP) compared to the negative SE group. The positive SE group also exhibited significantly higher basal and peak trans-isthmic gradients. Positive SE was found in 45.7% of patients, with 68.7% of these requiring re-intervention during follow-up. A peak trans-isthmic gradient > 61 mmHg during exercise predicted recoarctation with 100% sensitivity and 71% specificity (AUC = 0.836, p < 0.004). Conclusions: SE identifies at-risk patients post-CoA repair, aiding in early intervention. A peak trans-isthmic gradient > 61 mmHg during exercise is a strong predictor of recoarctation. These findings support incorporating SE into routine follow-up protocols for CoA patients, particularly those with a history of hypertension and borderline gradients, to improve long-term outcomes and quality of life.
RESUMEN
Liver transplant (LT) candidates undergo transthoracic echocardiography (TTE) before surgery to assess cardiac function and evaluate the echocardiographic probability of pulmonary hypertension (PHT). The improvement of pulmonary artery systolic pressure (PAPS) after transplant is associated with higher survival rates in patients with mild or moderate PHT. Although studies analyze the outcomes of LT in patients treated for PHT, the prognostic value of PAPS in patients without PHT in the follow-up is unknown. The aim of our study is to evaluate pre- and post-LT cardiac function, right ventricular function, pulmonary artery pressure, and their association with long-term mortality. 102 patients who underwent LT between 2011 and 2018 were compared for echocardiographic and hemodynamic parameters pre- and post-LT. After LT, systolic blood pressure, heart rate (HR), and PASP significantly increased, while tricuspid annular plane systolic excursion/PAPS decreased. Moreover, the higher difference in HR and PASP between pre- and post-LT was highlighted in those patients who died during the follow-up period after LT. Among all the parameters tested, in the multi-variable Cox regression for mortality, left ventricular ejection fraction and PASP difference were predictors of mortality. This study highlights the importance of TTE in LT screening as a tool to stratify patients at higher risk of death due to advanced cirrhotic cardiomyopathy and the importance of the change of echocardiographic parameters, in particular right and left ventricular hemodynamics, during the follow-up period. These parameters could be used to guide a more aggressive therapy.
RESUMEN
Background: Trifecta™ is an externally wrapped bovine pericardial aortic valve with a favorable hemodynamic performance and acceptable rate of freedom from structural valve degeneration. However, recent reports of early Trifecta valve failure question its durability. Rheumatic valve disease in young population is predominant, there is no data on the Trifecta performance, durability or safety available worldwide over the middle age population, as well as there are no previous similar reports from Middle East region. We report on mid-term clinical and hemodynamic performance of Trifecta valve in middle age population with small aortic annuls, a single center report. Methods: A retrospective study of all patients who underwent Trifecta™ SAVR between June 2014 and December 2019 at a cardiac center in Riyadh, Saudi Arabia. Hemodynamic performance was analyzed by longitudinal Doppler echocardiography. Results: During a 5.5-year period, a total of 24 patients underwent SAVR with Trifecta™ valves at our heart center. Patients had a median age of 47.1 years (IQR = 37) and male:female ratio of 1:1. Patients had a median EuroScoreII of 2 (IQR = 1). The 19 mm valve was the most frequently used (29.2%) followed by the 21 mm and 23 mm (both 25.0%). Concomitant procedure was (54.2%). All patients survived their operations and most (87.0%) had their symptoms relieved. A 30-day mortality rate of 4.2%. Patients were followed up for a median of 58.5 months (IQR = 38), during which 8.3% required re interventions, giving an overall freedom from re-intervention of 91.7%. The re-intervention after valve implantation was recorded in two (8.3%). These re-interventions were performed 3 years post initial surgery and were due to structural valve deterioration (SVD). The mean gradient reduced significantly from 43.6 ± 23.9 mmHg (median = 41, IQR = 21) at baseline to 13.0 ± 7.4 mmHg (median = 11, IQR = 5) one-week post intervention (p < 0.001). The average mean gradients were stable from post-operation to follow-up (13.0 ± 7.4 vs 14.1 ± 6.4 mmHg). Conclusion: Our study confirms excellent mid-term durability, clinical and hemodynamic performance of the Trifecta™ valve in middle age population, despite the fact of non-statically significant trend-up of transvalvular gradient over the follow up period. Further long-term studies with larger sample-size are warranted to confirm these results.
RESUMEN
The Ross procedure is gaining recognition as a significant option for aortic valve replacement (AVR), and is particularly beneficial in specific patient groups. Although categorized as a class IIb recommendation in the 2020 American College of Cardiology (ACC)/American Heart Association (AHA), and the European Society of Cardiology (ESC) management guidelines on valvular heart disease, recent studies bolster its credibility. Research, including a propensity-matched study, underlines the Ross procedure's association with enhanced long-term survival and reduced adverse valve-related events compared to other AVR types. This positions the Ross procedure as a primary option for AVR in young and middle-aged adults within specialized centers, and potentially the only choice for children and infants requiring AVR. This review meticulously examines the Ross procedure, covering historical perspectives, surgical techniques, imaging, and outcomes, including hemodynamic performance and quality of life, especially focusing on pediatric and young adult patients. It explores contemporary techniques and innovations like minimally invasive approaches and tissue engineering, underscoring ongoing research and future directions. A summarization of comparative studies and meta-analyses reiterates the Ross procedure's superior long-term outcomes, valve durability, and preservation of the left ventricular function, accentuating the crucial role of patient selection and risk stratification, and pinpointing areas for future research.