Gen Physiol Biophys ; 33(3): 281-4, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24968408

RESUMEN

The low shear viscometer LS300 permits measurements of viscosity with the same precision of the LS30 but is now fully controlled by the windows based software. That allows to determine viscosity at several shear rates and to establish flow curves enabling determination of the viscosity of non-Newtonian fluids. The viscosity of whole blood of ten adults was determined via flow curves approximated by Casson. The sensitivity of the LS300 was evaluated by determining the viscosity of water at rising temperatures and by establishing flow curves of ten specimen of the same blood sample.


Asunto(s)
Viscosidad Sanguínea , Eritrocitos/citología , Reología/instrumentación , Adulto , Fenómenos Biofísicos , Sedimentación Sanguínea , Diseño de Equipo , Humanos , Masculino , Resistencia al Corte , Programas Informáticos , Temperatura
2.
Gen Physiol Biophys ; 33(3): 285-93, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24968409

RESUMEN

The LS300 viscometer permits automated measurements of viscosity at several shear rates of non-Newtonian fluids. We determined whole blood and plasma viscosity, aggregation, red blood cell deformability, and hematocrit of 66 healthy adults. The effects of the anticoagulants EDTA, heparin and citrate, and of centrifugation on blood viscosity (n=12) and red blood cell geometry (n=5) were investigated. With regard to the whole blood viscosity of adults, the best agreement was obtained by Casson's calculation compared to the methods of Ostwald, Bingham and Newton. The approximated flow curve of plasma showed only marginal differences between the method of Newton and Ostwald, whereas the latter gave the best quality of approximation. Centrifugation and the anticoagulants had a significant impact on whole blood viscosity and yield shear stress, whereas erythrocyte geometry remained unaffected. By linear regression of hematocrit with viscosity and yield shear stress, its impact on blood viscosity could be calculated in a hematocrit range of 0.32-0.50. Determination of whole blood viscosity should be performed in a standardized manner at several shear rates and without centrifugation of the blood samples.


Asunto(s)
Viscosidad Sanguínea , Adulto , Anticoagulantes/química , Automatización , Interpretación Estadística de Datos , Agregación Eritrocitaria , Deformación Eritrocítica , Eritrocitos/citología , Femenino , Hematócrito , Humanos , Masculino , Resistencia al Corte , Programas Informáticos , Estrés Mecánico , Viscosidad