Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Antimicrob Chemother ; 77(10): 2867-2875, 2022 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-35978470

RESUMEN

BACKGROUND: Lateral flow immunoassays (LFIA) have shown their usefulness for detecting CTX-M- and carbapenemase-producing Enterobacterales (CPEs) in bacterial cultures. Here, we have developed and validated the BL-DetecTool to detect CTX-M enzymes and carbapenemases directly from clinical samples. METHODS: The BL-DetecTool is an LFIA that integrates an easy sample preparation device named SPID (Sampling, Processing, Incubation and Detection). It was evaluated in three University hospitals on urine, blood culture (BC) and rectal swab (RS) specimens either of clinical origin or on spiked samples. RS evaluation was done directly and after a 24 h enrichment step. RESULTS: The CTX-M BL-DetecTool was tested on 485 samples (154 BC, 150 urines, and 181 RS) and revealed a sensitivity and specificity of 97.04% (95% CI 92.59%-99.19%) and 99.43% (95% CI 97.95%-99.93%), respectively. Similarly, the Carba5 BL-DetecTool was tested on 382 samples (145 BC, 116 urines, and 121 RS) and revealed a sensitivity and specificity of 95.3% (95% CI 89.43%-98.47%) and 100% (95% CI 98.67%-100%), respectively. While with the Carba5 BL-DetecTool five false negatives were observed, mostly in RS samples, with the CTX-M BL-DetecTool, in addition to four false-negatives, two false-positives were also observed. Direct testing of RS samples revealed a sensitivity of 78% and 86% for CTX-M and carbapenemase detection, respectively. CONCLUSIONS: BL-DetecTool showed excellent biological performance, was easy-to-use, rapid, and could be implemented in any microbiology laboratory around the world, without additional equipment, no need for electricity, nor trained personnel. It offers an attractive alternative to costly molecular methods.


Asunto(s)
Infecciones por Enterobacteriaceae , Proteínas Bacterianas/genética , Cultivo de Sangre , Infecciones por Enterobacteriaceae/diagnóstico , Infecciones por Enterobacteriaceae/microbiología , Humanos , Sensibilidad y Especificidad , beta-Lactamasas/genética
2.
Microb Biotechnol ; 15(2): 603-612, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34342151

RESUMEN

Early detection of expanded-spectrum cephalosporin (ESC) resistance is essential not only for an effective therapy but also for the prompt implementation of infection control measures to prevent dissemination in the hospital. We have developed and validated a lateral flow immunoassay (LFIA), called LFIA-CTX test, for the detection of ESC (cefotaxime) hydrolytic activity based on structural discrimination between the intact antibiotic and its hydrolysed product. A single bacterial colony was suspended in an extraction buffer containing cefotaxime. After a 30-min incubation, the solution is loaded on the LFIA for reading within 10 min. A total of 348 well-characterized Gram-negative isolates were tested. Among them, the 38 isolates that did not express any cefotaxime-hydrolysing ß-lactamase gave negative results. Of the 310 isolates expressing at least one cefotaxime-hydrolysing ß-lactamase, all were tested positive, except three OXA-48-like producers, which were repeatedly detected negative. Therefore, the sensitivity was 99.1% and the specificity was 100%. The LFIA-CTX test is efficient, fast, low-cost and easy to implement in the workflow of a routine microbiology laboratory.


Asunto(s)
Cefalosporinas , beta-Lactamasas , Antibacterianos , Cefotaxima , Hidrólisis , Inmunoensayo , Pruebas de Sensibilidad Microbiana
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA