Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Cardiol Young ; 30(9): 1346-1349, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32600496

RESUMEN

We present our recent experience with a 6-month-old infant with a personal history of short bowel syndrome that presented with fever, cyanosis, and cardiogenic shock secondary to severe pulmonary hypertension and right ventricular failure without pulmonary thromboembolism. He did not present signs of toxin-mediated disease or Kawasaki disease. He was finally diagnosed with SARS-CoV-2 infection. If this presentation is confirmed in future research, the severe cardiovascular impairment in children with COVID-19 could be also attributable to the primary pulmonary infection, not only to a multisystem inflammatory syndrome but also in children without heart disease.


Asunto(s)
Angiografía por Tomografía Computarizada , Infecciones por Coronavirus , Insuficiencia Cardíaca , Hipertensión Pulmonar , Pandemias , Neumonía Viral , Choque Cardiogénico , Síndrome de Respuesta Inflamatoria Sistémica , Betacoronavirus/aislamiento & purificación , COVID-19 , Angiografía por Tomografía Computarizada/métodos , Infecciones por Coronavirus/complicaciones , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/tratamiento farmacológico , Infecciones por Coronavirus/fisiopatología , Infecciones por Coronavirus/terapia , Cuidados Críticos/métodos , Ecocardiografía/métodos , Electrocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Lactante , Masculino , Neumonía Viral/complicaciones , Neumonía Viral/diagnóstico , Neumonía Viral/fisiopatología , Neumonía Viral/terapia , Radiografía Torácica , Respiración Artificial/métodos , SARS-CoV-2 , Índice de Severidad de la Enfermedad , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Síndrome de Respuesta Inflamatoria Sistémica/diagnóstico , Síndrome de Respuesta Inflamatoria Sistémica/fisiopatología , Resultado del Tratamiento , Tratamiento Farmacológico de COVID-19
3.
JAMA Netw Open ; 7(5): e2413446, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38805223

RESUMEN

Importance: Surfactant administration may be needed in late preterm through full-term neonates, but the pathophysiology of their respiratory failure can be different from that of early preterm neonates. The lung ultrasonography score (LUS) is accurate to guide surfactant replacement in early preterm neonates, but to our knowledge, it has not yet been studied in the late preterm through full-term neonatal population. Objective: To assess whether LUS is equally accurate to predict surfactant need in late preterm through full-term neonates as in early preterm neonates. Design, Setting, and Participants: This prospective, international, multicenter diagnostic study was performed between December 2022 and November 2023 in tertiary academic neonatal intensive care units in France, Italy, Spain, and the US. Late preterm through full-term neonates (≥34 weeks' gestation) with respiratory failure early after birth were enrolled. Exposure: Point-of-care lung ultrasonography to calculate the neonatal LUS (range, 0-18, with higher scores indicating worse aeration), which was registered in dedicated research databases and unavailable for clinical decision-making. Main Outcomes and Measures: The main outcomes were the area under the curve (AUC) in receiver operating characteristic analysis and derived accuracy variables, considering LUS as a replacement for other tests (ie, highest global accuracy) and as a triage test (ie, highest sensitivity). Sample size was calculated to assess noninferiority of LUS to predict surfactant need in the study population compared with neonates born more prematurely. Correlations of LUS with the ratio of hemoglobin oxygen saturation as measured by pulse oximetry (SpO2) to fraction of inspired oxygen (FiO2) and with the oxygen saturation index (OSI) were assessed. Results: A total of 157 neonates (96 [61.1%] male) were enrolled and underwent lung ultrasonography at a median of 3 hours (IQR, 2-7 hours) of life; 32 (20.4%) needed surfactant administration (pretest probability, 20%). The AUC was 0.87 (95% CI, 0.81-0.92). The highest global accuracy and sensitivity were reached for LUS values higher than 8 or 4 or lower, respectively. Subgroup analysis gave similar diagnostic accuracy in neonates born late preterm (AUC, 0.89; 95% CI, 0.81-0.97; n = 111) and early term and later (AUC, 0.84; 95% CI, 0.73-0.96; n = 46). After adjusting for gestational age, LUS was significantly correlated with SpO2:FiO2 (adjusted ß, -10.4; 95% CI, -14.0 to -6.7; P < .001) and OSI (adjusted ß, 0.2; 95% CI, 0.1-0.3; P < .001). Conclusions and Relevance: In this diagnostic study of late preterm through full-term neonates with respiratory failure early after birth, LUS accuracy to predict surfactant need was not inferior to that observed in earlier preterm neonates. An LUS higher than 8 was associated with highest global accuracy (replacement test), suggesting that it can be used to guide surfactant administration. An LUS value of 4 or lower was associated with the highest sensitivity (triage test), suggesting it is unlikely for this population to need surfactant.


Asunto(s)
Recien Nacido Prematuro , Pulmón , Surfactantes Pulmonares , Síndrome de Dificultad Respiratoria del Recién Nacido , Ultrasonografía , Humanos , Recién Nacido , Surfactantes Pulmonares/administración & dosificación , Surfactantes Pulmonares/uso terapéutico , Estudios Prospectivos , Femenino , Ultrasonografía/métodos , Masculino , Pulmón/diagnóstico por imagen , Síndrome de Dificultad Respiratoria del Recién Nacido/diagnóstico por imagen , Edad Gestacional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA