Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Nucleic Acids Res ; 51(13): 6841-6856, 2023 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-37246713

RESUMEN

Horizontal gene transfer is tightly regulated in bacteria. Often only a fraction of cells become donors even when regulation of horizontal transfer is coordinated at the cell population level by quorum sensing. Here, we reveal the widespread 'domain of unknown function' DUF2285 represents an 'extended-turn' variant of the helix-turn-helix domain that participates in both transcriptional activation and antiactivation to initiate or inhibit horizontal gene transfer. Transfer of the integrative and conjugative element ICEMlSymR7A is controlled by the DUF2285-containing transcriptional activator FseA. One side of the DUF2285 domain of FseA has a positively charged surface which is required for DNA binding, while the opposite side makes critical interdomain contacts with the N-terminal FseA DUF6499 domain. The QseM protein is an antiactivator of FseA and is composed of a DUF2285 domain with a negative surface charge. While QseM lacks the DUF6499 domain, it can bind the FseA DUF6499 domain and prevent transcriptional activation by FseA. DUF2285-domain proteins are encoded on mobile elements throughout the proteobacteria, suggesting regulation of gene transfer by DUF2285 domains is a widespread phenomenon. These findings provide a striking example of how antagonistic domain paralogues have evolved to provide robust molecular control over the initiation of horizontal gene transfer.


Asunto(s)
Conjugación Genética , Proteobacteria , Proteínas Bacterianas/genética , Proteínas Bacterianas/metabolismo , Transferencia de Gen Horizontal , Proteobacteria/genética , Percepción de Quorum/genética , Factores de Transcripción/metabolismo , Activación Transcripcional
2.
Proc Natl Acad Sci U S A ; 119(5)2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35074874

RESUMEN

For nearly 50 years, the vision of using single molecules in circuits has been seen as providing the ultimate miniaturization of electronic chips. An advanced example of such a molecular electronics chip is presented here, with the important distinction that the molecular circuit elements play the role of general-purpose single-molecule sensors. The device consists of a semiconductor chip with a scalable array architecture. Each array element contains a synthetic molecular wire assembled to span nanoelectrodes in a current monitoring circuit. A central conjugation site is used to attach a single probe molecule that defines the target of the sensor. The chip digitizes the resulting picoamp-scale current-versus-time readout from each sensor element of the array at a rate of 1,000 frames per second. This provides detailed electrical signatures of the single-molecule interactions between the probe and targets present in a solution-phase test sample. This platform is used to measure the interaction kinetics of single molecules, without the use of labels, in a massively parallel fashion. To demonstrate broad applicability, examples are shown for probe molecule binding, including DNA oligos, aptamers, antibodies, and antigens, and the activity of enzymes relevant to diagnostics and sequencing, including a CRISPR/Cas enzyme binding a target DNA, and a DNA polymerase enzyme incorporating nucleotides as it copies a DNA template. All of these applications are accomplished with high sensitivity and resolution, on a manufacturable, scalable, all-electronic semiconductor chip device, thereby bringing the power of modern chips to these diverse areas of biosensing.


Asunto(s)
Técnicas Biosensibles/instrumentación , Electrónica/instrumentación , Pruebas de Enzimas/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , ADN , Diseño de Equipo/instrumentación , Cinética , Dispositivos Laboratorio en un Chip , Miniaturización/instrumentación , Nanotecnología/instrumentación , Semiconductores
3.
Anal Bioanal Chem ; 414(10): 3187-3196, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34741182

RESUMEN

We present an electrochemical impedimetric-based biosensor for monitoring the variation in human milk oligosaccharide (HMO) composition. 2'-Fucosyllactose (2'FL) is an HMO associated with infant growth, cognitive development, and protection from infectious diarrhea, one of the major causes of infant death worldwide. Due to genetic variation, the milk of some women (non-secretors) contains no or very little 2'FL with potential implications for infant health and development. However, there is currently no technology to analyze the presence and concentration of HMOs in human milk at the point-of-care (POC). The lack of such technology represents a major impediment to advancing human milk research and improving maternal-infant health. Towards this unmet need, we report an impedimetric assay for HMOs with an α-1,2 linkage, the most abundant of which is 2'FL. The sensor uses a lectin for affinity, specifically Ulex europaeus agglutinin I (UEA), with electrochemical readout. In spiked studies, the sensor exhibited a high degree of linearity (R2 = 0.991) over 0.5 to 3.0 µM with a 330-nM detection limit. The sensor performance was clinically validated using banked human milk samples and correctly identified all secretor vs. non-secretor samples. Furthermore, despite the short 35-min assay time and low sample volume (25 µL), the assay was highly correlated with HPLC measurements. This bedside human milk testing assay enables POC, "sample-to-answer" quantitative HMO measurement, and will be a valuable tool to assess milk composition.


Asunto(s)
Leche Humana , Sistemas de Atención de Punto , Cromatografía Líquida de Alta Presión , Femenino , Humanos , Lactante , Leche Humana/química , Oligosacáridos/química
4.
Sensors (Basel) ; 21(11)2021 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-34072374

RESUMEN

A plasmonic sensing platform was developed as a noninvasive method to monitor gas-phase biomarkers related to cystic fibrosis (CF). The nanohole array (NHA) sensing platform is based on localized surface plasmon resonance (LSPR) and offers a rapid data acquisition capability. Among the numerous gas-phase biomarkers that can be used to assess the lung health of CF patients, acetaldehyde was selected for this investigation. Previous research with diverse types of sensing platforms, with materials ranging from metal oxides to 2-D materials, detected gas-phase acetaldehyde with the lowest detection limit at the µmol/mol (parts-per-million (ppm)) level. In contrast, this work presents a plasmonic sensing platform that can approach the nmol/mol (parts-per-billion (ppb)) level, which covers the required concentration range needed to monitor the status of lung infection and find pulmonary exacerbations. During the experimental measurements made by a spectrometer and by a smartphone, the sensing examination was initially performed in a dry air background and then with high relative humidity (RH) as an interferent, which is relevant to exhaled breath. At a room temperature of 23.1 °C, the lowest detection limit for the investigated plasmonic sensing platform under dry air and 72% RH conditions are 250 nmol/mol (ppb) and 1000 nmol/mol (ppb), respectively.


Asunto(s)
Fibrosis Quística , Biomarcadores , Pruebas Respiratorias , Fibrosis Quística/diagnóstico , Espiración , Humanos , Resonancia por Plasmón de Superficie
5.
Sens Actuators B Chem ; 2962019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-32831479

RESUMEN

Rapid, on-site detection of fentanyl is of critical importance, as it is an extremely potent synthetic opioid that is prone to abuse. Here we describe a wearable glove-based sensor that can detect fentanyl electrochemically on the fingertips towards decentralized testing for opioids. The glove-based sensor consists of flexible screen-printed carbon electrodes modified with a mixture of multiwalled carbon nanotubes and a room temperature ionic liquid, 4-(3-butyl-1-imidazolio)-1-butanesulfonate). The sensor shows direct oxidation of fentanyl in both liquid and powder forms with a detection limit of 10 µM using square-wave voltammetry. The "Lab-on-a-Glove" sensors, combined with a portable electrochemical analyzer, provide wireless transmission of the measured data to a smartphone or tablet for further analysis. The integrated sampling and sensing methodology on the thumb and index fingers, respectively, enables rapid screening of fentanyl in the presence of a mixture of cutting agents and offers considerable promise for timely point-of-need screening for first responders. Such a glove-based "swipe, scan, sense, and alert" strategy brings chemical analytics directly to the user's fingertips and opens new possibilities for detecting substances of abuse in emergency situations.

6.
IEEE J Solid-State Circuits ; 53(7): 2054-2064, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30559530

RESUMEN

High-density biosensor arrays are essential for many cutting-edge biomedical applications including point-of-care vaccination screening to detect multiple highly-contagious diseases. Typical electrochemical biosensing techniques are based on the measurement of sub-pA currents for micron-sized sensors requiring highly-sensitive readout circuits. Such circuits are often too complex to scale down for high-density arrays. In this paper, a high-density 4,096-pixel electrochemical biosensor array in 180 nm CMOS is presented. It uses a coulostatic discharge sensing technique and interdigitated electrode geometry to reduce both the complexity and size of the readout circuitry. Each biopixel contains an interdigitated microelectrode with a 13 aA low-leakage readout circuit directly underneath. Compared to standard planar electrodes, the implemented interdigitated electrodes achieve a maximum amplification factor of 10.5× from redox cycling. The array's sensor density is comparable to state-of-the-art arrays, all without augmenting the sensors with complex post-processing. The detection of anti-Rubella and anti-Mumps antibodies in human serum is demonstrated.

7.
Proc Natl Acad Sci U S A ; 112(13): 4104-9, 2015 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-25787256

RESUMEN

Symbiosis islands are integrative and conjugative mobile genetic elements that convert nonsymbiotic rhizobia into nitrogen-fixing symbionts of leguminous plants. Excision of the Mesorhizobium loti symbiosis island ICEMlSym(R7A) is indirectly activated by quorum sensing through TraR-dependent activation of the excisionase gene rdfS. Here we show that a +1 programmed ribosomal frameshift (PRF) fuses the coding sequences of two TraR-activated genes, msi172 and msi171, producing an activator of rdfS expression named Frameshifted excision activator (FseA). Mass-spectrometry and mutational analyses indicated that the PRF occurred through +1 slippage of the tRNA(phe) from UUU to UUC within a conserved msi172-encoded motif. FseA activated rdfS expression in the absence of ICEMlSym(R7A), suggesting that it directly activated rdfS transcription, despite being unrelated to any characterized DNA-binding proteins. Bacterial two-hybrid and gene-reporter assays demonstrated that FseA was also bound and inhibited by the ICEMlSym(R7A)-encoded quorum-sensing antiactivator QseM. Thus, activation of ICEMlSym(R7A) excision is counteracted by TraR antiactivation, ribosomal frameshifting, and FseA antiactivation. This robust suppression likely dampens the inherent biological noise present in the quorum-sensing autoinduction circuit and ensures that ICEMlSym(R7A) transfer only occurs in a subpopulation of cells in which both qseM expression is repressed and FseA is translated. The architecture of the ICEMlSym(R7A) transfer regulatory system provides an example of how a set of modular components have assembled through evolution to form a robust genetic toggle that regulates gene transcription and translation at both single-cell and cell-population levels.


Asunto(s)
Sistema de Lectura Ribosómico , Secuencias Repetitivas Esparcidas , Percepción de Quorum , Ribosomas/ultraestructura , Secuencia de Bases , Sitios de Unión , Técnicas de Transferencia de Gen , Islas Genómicas , Espectrometría de Masas , Mesorhizobium/metabolismo , Plantas/microbiología , Plásmidos/metabolismo , Regiones Promotoras Genéticas , Biosíntesis de Proteínas , Rhizobium/metabolismo , Ribosomas/química , Simbiosis , Factores de Transcripción , Transcripción Genética , Técnicas del Sistema de Dos Híbridos , beta-Galactosidasa/metabolismo
8.
IEEE Sens J ; 17(3): 589-597, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28943809

RESUMEN

Portable and easy-to-use point-of-care (POC) diagnostic devices hold high promise for dramatically improving public health and wellness. In this paper, we present a mobile health (mHealth) immunoassay platform based on audio jack embedded devices, such as smartphones and laptops, that uses electrochemical impedance spectroscopy (EIS) to detect binding of target biomolecules. Compared to other biomolecular detection tools, this platform is intended to be used as a plug-and-play peripheral that reuses existing hardware in the mobile device and does not require an external battery, thereby improving upon its convenience and portability. Experimental data using a passive circuit network to mimic an electrochemical cell demonstrate that the device performs comparably to laboratory grade instrumentation with 0.3% and 0.5° magnitude and phase error, respectively, over a 17 Hz to 17 kHz frequency range. The measured power consumption is 2.5 mW with a dynamic range of 60 dB. This platform was verified by monitoring the real-time formation of a NeutrAvidin self-assembled monolayer (SAM) on a gold electrode demonstrating the potential for POC diagnostics.

9.
Sensors (Basel) ; 17(6)2017 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-28556804

RESUMEN

Currently, Cystic Fibrosis (CF) patients lack the ability to track their lung health at home, relying instead on doctor checkups leading to delayed treatment and lung damage. By leveraging the ubiquity of the smartphone to lower costs and increase portability, a smartphone-based peripheral pH measurement device was designed to attach directly to the headphone port to harvest power and communicate with a smartphone application. This platform was tested using prepared pH buffers and sputum samples from CF patients. The system matches within ~0.03 pH of a benchtop pH meter while fully powering itself and communicating with a Samsung Galaxy S3 smartphone paired with either a glass or Iridium Oxide (IrOx) electrode. The IrOx electrodes were found to have 25% higher sensitivity than the glass probes at the expense of larger drift and matrix sensitivity that can be addressed with proper calibration. The smartphone-based platform has been demonstrated as a portable replacement for laboratory pH meters, and supports both highly robust glass probes and the sensitive and miniature IrOx electrodes with calibration. This tool can enable more frequent pH sputum tracking for CF patients to help detect the onset of pulmonary exacerbation to provide timely and appropriate treatment before serious damage occurs.


Asunto(s)
Teléfono Inteligente , Fibrosis Quística , Electrodos , Humanos , Pulmón
10.
Sens Actuators B Chem ; 235: 126-135, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27725788

RESUMEN

Cellular phone penetration has grown continually over the past two decades with the number of connected devices rapidly approaching the total world population. Leveraging the worldwide ubiquity and connectivity of these devices, we developed a mobile phone-based electrochemical biosensor platform for point-of-care (POC) diagnostics and wellness tracking. The platform consists of an inexpensive electronic module (< $20) containing a low-power potentiostat that interfaces with and efficiently harvests power from a wide variety of phones through the audio jack. Active impedance matching improves the harvesting efficiency to 79%. Excluding loses from supply rectification and regulation, the module consumes 6.9 mW peak power and can measure < 1 nA bidirectional current. The prototype was shown to operate within the available power budget set by mobile devices and produce data that matches well with that of an expensive laboratory grade instrument. We demonstrate that the platform can be used to track the concentration of secretory leukocyte protease inhibitor (SLPI), a biomarker for monitoring lung infections in cystic fibrosis patients, in its physiological range via an electrochemical sandwich assay on disposable screen-printed electrodes with a 1 nM limit of detection.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38814775

RESUMEN

Opioid tampering and diversion pose a serious problem for hospital patients with potentially life-threatening consequences. The ongoing opioid crisis has resulted in medications used for pain management and anesthesia, such as fentanyl and morphine, being stolen, substituted with a different substance, and abused. This work aims to mitigate tampering and diversion through analytical verification of the administered drug before it enters the patient. We present an electrochemical-based sensor and miniaturized wireless potentiostat that enable real-time intravenous (IV) monitoring of opioids, specifically fentanyl and morphine. The proposed system is connected to an IV drip system during surgery or post-operation recovery. Measurement results of two opioids are presented, including calibration curves and data on the sensor performance concerning pH, temperature, interference, reproducibility, and long-term stability. Finally, we demonstrate real-time fluidic measurements connected to a flow cell to simulate IV administration and a blind study classified using a machine-learning algorithm. The system achieves limits of detection (LODs) of 1.26 µg/mL and 2.75 µg/mL for fentanyl and morphine, respectively, while operating with >1-month battery lifetime due to an optimized ultra-low power 36 µA sleep mode.

12.
Front Bioeng Biotechnol ; 12: 1363186, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38544982

RESUMEN

Hydrolytic enzymes play crucial roles in cellular processes, and dysregulation of their activities is implicated in various physiological and pathological conditions. These enzymes cleave substrates such as peptide bonds, phosphodiester bonds, glycosidic bonds, and other esters. Detecting aberrant hydrolase activity is vital for understanding disease mechanisms and developing targeted therapeutic interventions. This study introduces a novel approach to measuring hydrolase activity using giant magnetoresistive (GMR) spin valve sensors. These sensors change resistance in response to magnetic fields, and here, they are functionalized with specific substrates for hydrolases conjugated to magnetic nanoparticles (MNPs). When a hydrolase cleaves its substrate, the tethered magnetic nanoparticle detaches, causing a measurable shift in the sensor's resistance. This design translates hydrolase activity into a real-time, activity-dependent signal. The assay is simple, rapid, and requires no washing steps, making it ideal for point-of-care settings. Unlike fluorescent methods, it avoids issues like autofluorescence and photobleaching, broadening its applicability to diverse biofluids. Furthermore, the sensor array contains 80 individually addressable sensors, allowing for the simultaneous measurement of multiple hydrolases in a single reaction. The versatility of this method is demonstrated with substrates for nucleases, Bcu I and DNase I, and the peptidase, human neutrophil elastase. To demonstrate a clinical application, we show that neutrophil elastase in sputum from cystic fibrosis patients hydrolyze the peptide-GMR substrate, and the cleavage rate strongly correlates with a traditional fluorogenic substrate. This innovative assay addresses challenges associated with traditional enzyme measurement techniques, providing a promising tool for real-time quantification of hydrolase activities in diverse biological contexts.

13.
IEEE J Solid-State Circuits ; 48(5): 1290-1301, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-24761029

RESUMEN

Magnetic nanotechnologies have shown significant potential in several areas of nanomedicine such as imaging, therapeutics, and early disease detection. Giant magnetoresistive spin-valve (GMR SV) sensors coupled with magnetic nanotags (MNTs) possess great promise as ultra-sensitive biosensors for diagnostics. We report an integrated sensor interface for an array of 256 GMR SV biosensors designed in 0.18 µm CMOS. Arranged like an imager, each of the 16 column level readout channels contains an analog front- end and a compact ΣΔ modulator (0.054 mm2) with 84 dB of dynamic range and an input referred noise of 49 nT/√Hz. Performance is demonstrated through detection of an ovarian cancer biomarker, secretory leukocyte peptidase inhibitor (SLPI), spiked at concentrations as low as 10 fM. This system is designed as a replacement for optical protein microarrays while also providing real-time kinetics monitoring.

14.
Lab Chip ; 23(18): 4033-4043, 2023 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-37603416

RESUMEN

Sample preparation is essential for nucleic acid assays, affecting their sensitivity and reliability. However, this process often results in a significant loss or dilution of the analyte, which becomes a bottleneck that limits downstream assay performance, particularly for assays that accept a limited input sample volume. To overcome this challenge, we present an evaporative-based sample enrichment method that uses an airjet to concentrate analytes within a small, defined volume by reversing the coffee-ring effect. A small, concentrated sample can then be collected for analysis to increase the initial sample load. The effectiveness of the reported airjet enrichment was quantified using qPCR of λ-DNA, HeLa-S3 RNA, and heat-inactivated SARS-CoV-2 samples. Comparisons between airjet enrichment and conventional evaporative concentration methods demonstrated significant advantages of airjet enrichment, including the ability to concentrate a high percentage of analyte within a 1 µL volume. The enrichment method was then integrated and adapted for various fluid volumes commonly found in nucleic acid sample preparation procedures. Here, airjet enrichment reduced the overall Cq by an average of 9.27 cycles for each analyte, resulting in a 600-fold enrichment from the initial concentration. To perform selective enrichment and prevent salt-based interference in downstream analysis, PEG was added to reduce the co-enrichment of salt. In addition, a preliminary study was conducted to explore the integration of airjet enrichment into ELISA using rabbit IgG as a model antigen. These findings demonstrate how airjet enrichment can be easily integrated into existing laboratory protocols with minimal modification and significantly improve the performance of biosensors.


Asunto(s)
COVID-19 , Animales , Conejos , Reproducibilidad de los Resultados , SARS-CoV-2 , Cloruro de Sodio , ARN
15.
Biosens Bioelectron ; 227: 115097, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36858023

RESUMEN

Stress is part of everyone's life and is exacerbated by traumatic events such as pandemics, disasters, violence, lifestyle changes, and health disorders. Chronic stress has many detrimental health effects and can even be life-threatening. Long-term stress monitoring outside of a hospital is often accomplished by measuring heart rate variability. While easy to measure, this digital biomarker has low specificity, greatly limiting its utility. To address this shortcoming, we report a non-invasive, wearable biomolecular sensor to monitor cortisol levels in sweat. Cortisol is a neuroendocrine hormone that regulates homeostasis as part of the stress pathway. Cortisol is detected using an electrochemical sensor functionalized with a pseudoknot-assisted aptamer and a flexible microfluidic sweat sampling system. The skin-worn microfluidic sampler provides rapid sweat collection while separating old and new sweat. The conformation-switching aptamer provides high specificity towards cortisol while being regenerable, allowing it to monitor temporal changes continuously. The aptamer was engineered to add a pseudoknot, restricting it to only two states, thus minimizing the background signal and enabling high sensitivity. An electrochemical pH sensor allows pH-corrected amperometric measurements. Device operation was demonstrated invitro with a broad linear dynamic range (1 pM - 1 µM) covering the physiological range and a sub-picomolar (0.2 pM) limit of detection in sweat. Real-time, on-body measurements were collected from human subjects using an induced stress protocol, demonstrating in-situ signal regeneration and the ability to detect dynamic cortisol fluctuations continuously for up to 90 min. The reported device has the potential to improve prognosis and enable personalized treatments.


Asunto(s)
Hidrocortisona , Microfluídica , Monitoreo Fisiológico , Estrés Psicológico , Sudor , Dispositivos Electrónicos Vestibles , Dispositivos Electrónicos Vestibles/normas , Hidrocortisona/análisis , Aptámeros de Nucleótidos , Sudor/química , Electroquímica , Concentración de Iones de Hidrógeno , Límite de Detección , Microfluídica/instrumentación , Microfluídica/métodos , Microfluídica/normas , Estrés Psicológico/fisiopatología , Reproducibilidad de los Resultados , Electrodos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/normas , Humanos , Sensibilidad y Especificidad
16.
Front Bioeng Biotechnol ; 11: 1256267, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37790251

RESUMEN

Complications posed by preterm birth (delivery before 37 weeks of pregnancy) are a leading cause of newborn morbidity and mortality. The previous discovery and validation of an algorithm that includes maternal serum protein biomarkers, sex hormone-binding globulin (SHBG), and insulin-like growth factor-binding protein 4 (IBP4), with clinical factors to predict preterm birth represents an opportunity for the development of a widely accessible point-of-care assay to guide clinical management. Toward this end, we developed SHBG and IBP4 quantification assays for maternal serum using giant magnetoresistive (GMR) sensors and a self-normalizing dual-binding magnetic immunoassay. The assays have a picomolar limit of detections (LOD) with a relatively broad dynamic range that covers the physiological level of the analytes as they change throughout gestation. Measurement of serum from pregnant donors using the GMR assays was highly concordant with those obtained using a clinical mass spectrometry (MS)-based assay for the same protein markers. The MS assay requires capitally intense equipment and highly trained operators with a few days turnaround time, whereas the GMR assays can be performed in minutes on small, inexpensive instruments with minimal personnel training and microfluidic automation. The potential for high sensitivity, accuracy, and speed of the GMR assays, along with low equipment and personnel requirements, make them good candidates for developing point-of-care tests. Rapid turnaround risk assessment for preterm birth would enable patient testing and counseling at the same clinic visit, thereby increasing the timeliness of recommended interventions.

17.
Nano Lett ; 11(7): 2579-83, 2011 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-20804215

RESUMEN

We report an autoassembly protein array capable of rapidly screening for aberrant antibody-antigen binding events. Our technique combines magnetic nanoparticle technology with proximity-based, magnetically responsive nanosensors for rapid (under 15 min) and high-density screening of antibody cross-reactivity at sensitivities down to 50 fM in a homogeneous assay. This method will enable the identification of the precise cause of aberrant or cross-reactive binding events in an easy-to-use, rapid, and high-throughput manner.


Asunto(s)
Anticuerpos/análisis , Anticuerpos/inmunología , Reacciones Cruzadas/inmunología , Nanotecnología , Análisis por Matrices de Proteínas , Reacciones Antígeno-Anticuerpo , Ensayos Analíticos de Alto Rendimiento , Inmunoensayo , Magnetismo
18.
ACS Omega ; 7(43): 39097-39106, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36340178

RESUMEN

Monitoring the anti-epileptic drug carbamazepine (CBZ) is crucial for proper dosing, optimizing a patient's clinical outcome, and managing their medication regimen. Due to its narrow therapeutic window and concentration-related toxicity, CBZ is prescribed and monitored in a highly personalized manner. We report an electrochemical conformation-changing aptasensor with two assay formats: a 30 min assay for routine monitoring and a 5 min assay for rapid emergency testing. To enable "sample-to-answer" testing, a de novo CBZ aptamer (K d < 12 nM) with conformational switching due to a G-quadruplex motif was labeled with methylene blue and immobilized on a gold electrode. The electrode fabrication and detection conditions were optimized using electrochemical techniques and visualized by atomic force microscopy (AFM). The aptasensor performance, including reproducibility, stability, and interference, was characterized using electrochemical impedance spectroscopy and voltammetry techniques. The aptasensor exhibited a wide dynamic range in buffer (10 nM to 100 µM) with limits of detection of 1.25 and 1.82 nM for the 5 and 30 min assays, respectively. The clinical applicability is demonstrated by detecting CBZ in finger prick blood samples (<50 µL). The proposed assays provide a promising method to enable point-of-care monitoring for timely personalized CBZ dosing.

19.
IEEE Trans Biomed Circuits Syst ; 16(4): 692-702, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35900998

RESUMEN

This paper presents an analog front-end (AFE) for fast-scan cyclic voltammetry (FSCV) with analog background subtraction using a pseudo-differential sensing scheme to cancel the large non-faradaic current before seeing the front-end. As a result, the AFE can be compact and low-power compared to conventional FSCV AFEs with dedicated digital back-ends to digitize and subtract the background from subsequent recordings. The reported AFE, fabricated in a 0.18- µ m CMOS process, consists of a class-AB common-mode rejection circuit, a low-input-impedance current conveyor, and a 1st-order current-mode delta-sigma (ΔΣ) modulator with an infinite impulse response quantizer. This AFE achieves an effective dynamic range of 83 dB with a state-of-the-art 39.2 pArms input-referred noise when loaded with a 1 nF input capacitance (26.5 pArms open-circuit) across a 5 kHz bandwidth while consuming an average power of 3.7 µW. This design was tested with carbon-fiber microelectrodes scanned at 300 V/s using flow-injection of dopamine, a key neurotransmitter.


Asunto(s)
Dopamina , Neurotransmisores , Carbono , Diseño de Equipo , Microelectrodos
20.
Sci Rep ; 12(1): 22520, 2022 12 29.
Artículo en Inglés | MEDLINE | ID: mdl-36581649

RESUMEN

Although universal biometrics have been broadly called for, and there are many validated technologies to recognize adults, these technologies have been ineffective in newborns and young children. The present work describes the development and clinical testing of a fingerprint capture system for longitudinal biometric recognition of newborns and young children to support vaccination and clinical follow-up. The reader consists of a high-resolution monochromatic imaging system with an ergonomic industrial design to comfortably support and align infant fingers for imaging without a platen. This imaging approach without a platen, also called free-space imaging, reduces fingerprint distortion and ensures a more consistent finger placement. This system was tested in a newborn ward and immunization clinic at an urban hospital in Baja, California, Mexico, from 2017 to 2019. Nearly five hundred children were enrolled and followed for up to 24 months. With a protocol of imaging all ten fingers, the failure to enroll (FTE) rate was < 1% when acquiring at least two fingers for all ages and < 2% when enrolling at least four fingers. The verification (1:1) true accept rate (TAR) was 77% for newborns enrolled at ≤ 3 days of age and 96% for those enrolled at ≥ 4 days of age, both at a time gap of 15-30 days after enrollment at a false accept rate (FAR) of 0.1%. Using the top-ranked match score, the identification rate (1:many) was 86% for the ≤ 3 days enrollment age and 97% for age ≥ 4 days for a single finger at 15-30 days after enrollment. The enrollment protocol and the frequency of updating will increase for infants compared to adults. However, these data suggest that a high-resolution, free space imaging technique may fill the final gap for universal biometrics across all populations called for by the United Nations Sustainable Development Goal 16.9.


Asunto(s)
Biometría , Hospitales Urbanos , Lactante , Adulto , Humanos , Recién Nacido , Niño , Preescolar , Estudios Prospectivos , Atención a la Salud , Vacunación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA