Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Am J Transplant ; 16(5): 1526-39, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26695524

RESUMEN

Hypothermic machine perfusion (HMP) is increasingly used in deceased donor kidney transplantation, but controversy exists regarding the value of perfusion biomarkers and pump parameters for assessing organ quality. We prospectively determined associations between perfusate biomarkers (neutrophil gelatinase-associated lipocalin [NGAL], kidney injury molecule 1, IL-18 and liver-type fatty acid-binding protein [L-FABP]) and pump parameters (resistance and flow) with outcomes of delayed graft function (DGF) and 6-mo estimated GFR (eGFR). DGF occurred in 230 of 671 (34%) recipients. Only 1-h flow was inversely associated with DGF. Higher NGAL or L-FABP concentrations and increased resistance were inversely associated with 6-mo eGFR, whereas higher flow was associated with higher adjusted 6-mo eGFR. Discarded kidneys had consistently higher median resistance and lower median flow than transplanted kidneys, but median perfusate biomarker concentrations were either lower or not significantly different in discarded compared with transplanted kidneys. Notably, most recipients of transplanted kidneys with isolated "undesirable" biomarker levels or HMP parameters experienced acceptable 6-mo allograft function, suggesting these characteristics should not be used in isolation for discard decisions. Additional studies must confirm the utility of combining HMP measurements with other characteristics to assess kidney quality.


Asunto(s)
Biomarcadores/metabolismo , Funcionamiento Retardado del Injerto/diagnóstico , Funcionamiento Retardado del Injerto/metabolismo , Hipotermia Inducida/instrumentación , Fallo Renal Crónico/cirugía , Trasplante de Riñón/efectos adversos , Donantes de Tejidos , Aloinjertos , Cadáver , Funcionamiento Retardado del Injerto/epidemiología , Funcionamiento Retardado del Injerto/etiología , Femenino , Estudios de Seguimiento , Humanos , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Preservación de Órganos , Perfusión , Pronóstico , Estudios Prospectivos , Factores de Tiempo , Obtención de Tejidos y Órganos
2.
Am J Transplant ; 15(6): 1623-31, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25762442

RESUMEN

Deceased donor kidneys with acute kidney injury (AKI) are often discarded due to fear of poor outcomes. We performed a multicenter study to determine associations of AKI (increasing admission-to-terminal serum creatinine by AKI Network stages) with kidney discard, delayed graft function (DGF) and 6-month estimated glomerular filtration rate (eGFR). In 1632 donors, kidney discard risk increased for AKI stages 1, 2 and 3 (compared to no AKI) with adjusted relative risks of 1.28 (1.08-1.52), 1.82 (1.45-2.30) and 2.74 (2.0-3.75), respectively. Adjusted relative risk for DGF also increased by donor AKI stage: 1.27 (1.09-1.49), 1.70 (1.37-2.12) and 2.25 (1.74-2.91), respectively. Six-month eGFR, however, was similar across AKI categories but was lower for recipients with DGF (48 [interquartile range: 31-61] vs. 58 [45-75] ml/min/1.73m(2) for no DGF, p < 0.001). There was significant favorable interaction between donor AKI and DGF such that 6-month eGFR was progressively better for DGF kidneys with increasing donor AKI (46 [29-60], 49 [32-64], 52 [36-59] and 58 [39-71] ml/min/1.73m(2) for no AKI, stage 1, 2 and 3, respectively; interaction p = 0.05). Donor AKI is associated with kidney discard and DGF, but given acceptable 6-month allograft function, clinicians should consider cautious expansion into this donor pool.


Asunto(s)
Lesión Renal Aguda/fisiopatología , Funcionamiento Retardado del Injerto/fisiopatología , Rechazo de Injerto/epidemiología , Rechazo de Injerto/fisiopatología , Trasplante de Riñón , Donantes de Tejidos , Adulto , Aloinjertos , Biopsia , Estudios de Cohortes , Femenino , Tasa de Filtración Glomerular/fisiología , Humanos , Incidencia , Riñón/patología , Riñón/fisiopatología , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo
3.
Am J Transplant ; 14(4): 886-96, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24612768

RESUMEN

Accurate and reliable assessment tools are needed in transplantation. The objective of this prospective, multi-center study was to determine the associations of the alpha and pi iso-enzymes of glutathione S-transferase (GST), measured from perfusate solution at the start and end (base and post) of kidney allograft machine perfusion, with subsequent delayed graft function (DGF). We also compared GST iso-enzyme perfusate levels from discarded versus transplanted kidneys. A total of 428 kidneys were linked to outcomes as recorded by the United Network of Organ Sharing. DGF, defined as any dialysis in the first week of transplant, occurred in 141 recipients (32%). Alpha- and pi-GST levels significantly increased during machine perfusion. The adjusted relative risks (95% confidence interval) of DGF with each log-unit increase in base and post pi-GST were 1.14 (1.0-1.3) and 1.36 (1.1-1.8), respectively. Alpha-GST was not independently associated with DGF. There were no significant differences in GST values between discarded and transplanted kidneys, though renal resistance was significantly higher in discarded kidneys. We found pi-GST at the end of machine perfusion to be independently associated with DGF. Further studies should elucidate the utility of GST for identifying injured kidneys with regard to organ allocation, discard and recipient management decisions.


Asunto(s)
Biomarcadores/metabolismo , Funcionamiento Retardado del Injerto/diagnóstico , Gutatión-S-Transferasa pi/metabolismo , Glutatión Transferasa/metabolismo , Isoenzimas/metabolismo , Fallo Renal Crónico/complicaciones , Trasplante de Riñón/efectos adversos , Complicaciones Posoperatorias/diagnóstico , Funcionamiento Retardado del Injerto/enzimología , Funcionamiento Retardado del Injerto/etiología , Ensayo de Inmunoadsorción Enzimática , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Humanos , Fallo Renal Crónico/cirugía , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Perfusión , Complicaciones Posoperatorias/enzimología , Complicaciones Posoperatorias/etiología , Pronóstico , Estudios Prospectivos , Factores de Riesgo
4.
Kidney Int Rep ; 2(4): 749-758, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28730184

RESUMEN

INTRODUCTION: Existing methods to predict recipient allograft function during deceased-donor kidney procurement are imprecise. Understanding the potential renal reparative role for monocyte chemoattractant protein-1 (MCP-1), a cytokine involved in macrophage recruitment after injury, might help predict allograft outcomes. METHODS: We conducted a sub-study of the multicenter prospective Deceased Donor Study cohort, which evaluated deceased kidney donors from five organ procurement organizations from May 2010 to December 2013. We measured urine MCP-1 (uMCP-1) concentrations from donor samples collected at nephrectomy to determine associations with donor acute kidney injury (AKI), recipient delayed graft function (DGF), 6-month estimated GFR (eGFR), and graft failure. We also assessed perfusate MCP-1 concentrations from pumped kidneys for associations with DGF and 6-month eGFR. RESULTS: AKI occurred in 111 (9%) donors. Median (interquartile range) uMCP-1 concentration was higher in donors with AKI compared to donors without AKI (1.35 [0.41-3.93] ng/ml vs. 0.32 [0.11-0.80] ng/ml, p<0.001). DGF occurred in 756 (31%) recipients, but uMCP-1 was not independently associated with DGF. Higher donor uMCP-1 concentrations were independently associated with higher 6-month eGFR in those without DGF [0.77 (0.10, 1.45) ml/min/1.73m2 per doubling of uMCP1]. However, there were no independent associations between uMCP-1 and graft failure over a median follow-up of about 2 years. Lastly, perfusate MCP-1 concentrations significantly increased during pump perfusion but were not associated with DGF or 6-month eGFR. CONCLUSION: Donor uMCP-1 concentrations were modestly associated with higher recipient 6-month eGFR in those without DGF. However, the results suggest that donor uMCP-1 has minimal clinical utility given no associations with graft failure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA