1.
Ophthalmic Plast Reconstr Surg ; 33(6): 452-458, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27861329

RESUMEN

PURPOSE: To compare hydroxyapatite with acrylic implants after enucleation for uveal melanoma with respect to eyelid position, ocular motility, implant complications, and patient satisfaction. METHODS: Patients undergoing primary enucleation for uveal melanoma between May 2005 and November 2012 at the Liverpool Ocular Oncology Centre, United Kingdom, were randomized between hydroxyapatite and acrylic implants. Questionnaires were sent to patients and ocularists to comment on the main outcomes. RESULTS: A total of 416 patients were recruited in the study, of whom 281 were included, with 49.5% (139/281) and 50.5% (142/281) receiving a hydroxyapatite (HA) or acrylic (AC) implant. Mailed questionnaires completed at ≥18 months by patients showed no significant differences between the groups in eyelid position, prosthetic motility, socket complications, and patient satisfaction. Complications included implant extrusion (1% vs 4%), enophthalmos (26% vs 26%), and superior sulcus deformity (24% vs 24%) with HA and AC implants, respectively, (Fisher exact test p > 0.0125 in all, Bonferroni correction). Questionnaires completed by ocularists indicated no significant differences in eyelid opening, prosthetic motility, and other complications at 6 months (Fisher exact test, p > 0.05 in all); there was a higher prevalence of ptosis with AC than HA implants (46% vs 25%, p = 0.03) and a greater need for ocularists' treatment with HA than AC (50% vs 28%, p = 0.03). CONCLUSIONS: Patient-reported outcomes after enucleation for uveal melanoma indicate no major differences between hydroxyapatite and acrylic implants in surgical outcomes and patient satisfaction. There was a higher prevalence of ptosis with AC and a greater need of ocularists' visits with HA at around 6 months observed by ocularists.


Asunto(s)
Durapatita , Enucleación del Ojo , Melanoma/cirugía , Implantes Orbitales , Polimetil Metacrilato , Implantación de Prótesis/métodos , Neoplasias de la Úvea/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Porosidad , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Encuestas y Cuestionarios , Resultado del Tratamiento , Adulto Joven
2.
Eye (Lond) ; 36(4): 812-817, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33888865

RESUMEN

PURPOSE: Retrospective case series evaluating the efficacy and safety of implanting XtraFocus™ pinhole device in pseudophakic patients with irregular corneal astigmatism with concurrent or standalone iris defect. METHODS: Electronic case records were searched for: uncorrected distance visual acuities (UDVA) and corrected distance visual acuities (CDVA), automatic or manifest refraction and spherical equivalent (SE). All main outcomes were evaluated preoperatively and postoperatively at 1, 3, 6, 9 and 12 months, along with patients' satisfactory outcome and complications. RESULTS: Eleven pseudophakic eyes of 11 patients with a mean age of 54 (range 27-81) years were included. Median UDVA improved significantly from logMAR 0.7 (range 0.1-1.22) pre-operatively to 0.4 (range 0-1.3) at 1-month (p = 0.002); median CDVA remained unchanged at logMAR 0.4 (range 0-0.1) pre-operatively and 0.4 (range 0-0.8) at 1-month (p = 0.36). There were no significant statistical differences in both UDVA and CDVA between the post-operative periods. Ten patients (90.9%) had initial UDVA improvement at 1-month post op. Eight (72.7%) patients expressed satisfaction with improved vision or reduction of glare/halos. Three (27.3%) patients had unsatisfactory visual outcome resulting in 2 requested for implant explantation due to worsening of glare and distressing floaters. CONCLUSIONS: XtraFocus™ is effective in improving vision or reducing glare in pseudophakic patients with irregular corneal astigmatism or intragenic iris trauma, with over 70% expressed satisfactory outcome. Disturbing floaters and glare preclude its use in some resulting in implant explantation.


Asunto(s)
Astigmatismo , Enfermedades de la Córnea , Lesiones Oculares , Adulto , Anciano , Anciano de 80 o más Años , Astigmatismo/etiología , Astigmatismo/cirugía , Enfermedades de la Córnea/cirugía , Lesiones Oculares/cirugía , Ojo Artificial/efectos adversos , Humanos , Iris/cirugía , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Refracción Ocular , Estudios Retrospectivos , Resultado del Tratamiento
3.
J Cataract Refract Surg ; 45(5): 685-689, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30879718

RESUMEN

We describe two patients in whom postsurgical refractive error occurred after routine refractive lens exchange cataract surgery with multifocal intraocular lens insertion most likely attributable to the presence of underlying corneal epithelial basement membrane dystrophy (EBMD). In Case 1, there was an unexpected hyperopic postoperative spherical equivalent refractive error of +1.50 diopters and in Case 2, a cylindrical refractive error of 2.75 diopter cylinder. We examine the possible causes of error and discuss potential management strategies to prevent and address these unpredictable postoperative outcomes. The importance of comprehensive and careful ocular surface assessment before cataract or refractive surgery as part of the presurgical workup is reemphasized. EBMD can be subtle and if overlooked, can affect the validity of biometric keratometric measurements preoperatively, resulting in an inaccurate biometry measurement, incorrect IOL selection, and reduced visual performance and patient satisfaction.


Asunto(s)
Membrana Basal/patología , Extracción de Catarata/métodos , Catarata/complicaciones , Síndrome de Cogan/complicaciones , Lentes Intraoculares Multifocales , Refracción Ocular/fisiología , Anciano , Membrana Basal/cirugía , Síndrome de Cogan/diagnóstico , Síndrome de Cogan/cirugía , Topografía de la Córnea , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Microscopía con Lámpara de Hendidura
4.
BMJ Case Rep ; 20132013 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-23616314

RESUMEN

This case illustrates an overlooked metastatic lung carcinoma to the orbit. The rapid onset of symptoms and oedema mimicked a cellulitis. The patient was initially treated with a broad-spectrum topical and intravenous antibiotic therapy. The white blood cell count (WBC) and C reactive protein (CRP) were normal. Compressive optic neuropathy and serous retinal detachment ensued. The initial chest x-ray revealed lung shadows; however, this was not reviewed. Eventually, CT of the chest was organised and showed a lung mass. The management of such a case remains a challenge for the uninitiated, and high index of suspicion is required to ensure early appropriate management. Despite complete resolution of the swelling with sequential chemotherapy (cisplatin and etoposide) and radiotherapy, the visual prognosis remained grim.


Asunto(s)
Exoftalmia/etiología , Neoplasias Pulmonares/patología , Neoplasias Orbitales/secundario , Anciano , Biopsia , Diagnóstico Diferencial , Exoftalmia/diagnóstico , Exoftalmia/terapia , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Neoplasias Orbitales/diagnóstico , Neoplasias Orbitales/terapia , Tomografía Computarizada por Rayos X