Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Neurogastroenterol Motil ; 28(4): 554-68, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26863609

RESUMEN

BACKGROUND: Current investigations of stomach function are based on small test meals that do not reliably induce symptoms and analysis techniques that rarely detect clinically relevant dysfunction. This study introduces the large 'Nottingham Test Meal' (NTM) for assessment of gastric motor and sensory function by non-invasive imaging. METHODS: NTM comprises 400 mL liquid nutrient (0.75 kcal/mL) and 12 solid agar-beads (0 kcal) with known breaking strength. Gastric fullness and dyspeptic sensations were documented by 100 mm visual analogue scale (VAS). Gastric emptying (GE) were measured in 24 healthy volunteers (HVs) by gastric scintigraphy (GS) and magnetic resonance imaging (MRI). The contribution of secretion to gastric volume was assessed. Parameters that describe GE were calculated from validated models. Inter-observer agreement and reproducibility were assessed. KEY RESULTS: NTM produced moderate fullness (VAS ≥30) but no more than mild dyspeptic symptoms (VAS <30) in 24 HVs. Stable binding of meal components to labels in gastric conditions was confirmed. Distinct early and late-phase GE were detected by both modalities. Liquid GE half-time was median 49 (95% CI: 36-62) min and 68 (57-71) min for GS and MRI, respectively. Differences between GS and MRI measurements were explained by the contribution of gastric secretion. Breaking strength for agar-beads was 0.8 N/m(2) such that median 25 (8-50) % intact agar-beads and 65 (47-74) % solid material remained at 120 min on MRI and GS, respectively. Good reproducibility for liquid GE parameters was present and GE was not altered by agar-beads. CONCLUSIONS & INFERENCES: The NTM provided an objective assessment of gastric motor and sensory function. The results were reproducible and liquid emptying was not affected by non-nutrient agar-beads. The method is potentially suitable for clinical practice.


Asunto(s)
Gastroenterología/métodos , Gastropatías/diagnóstico , Adulto , Anciano , Femenino , Vaciamiento Gástrico/fisiología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Cintigrafía , Reproducibilidad de los Resultados , Adulto Joven
2.
Phys Med Biol ; 60(3): 1367-83, 2015 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-25592405

RESUMEN

MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean ± SD coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 ± 2% at large gastric volumes (>200 ml). Mean ± SD secretion volumes post meal ingestion were 64 ± 51 ml and 110 ± 40 ml at 15 and 75 min, respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient ± std err of 1.06 ± 0.10 and intercept -11 ± 24 ml. In conclusion, (i) rapid volume acquisition and respiratory triggered T1 mapping removed the requirement to image during prolonged breath-holds (ii) semi-automatic analysis greatly reduced the time required to derive measurements and (iii) correction for secretion volumes provided accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice.


Asunto(s)
Vaciamiento Gástrico , Imagen por Resonancia Magnética/métodos , Estómago/patología , Adulto , Algoritmos , Automatización , Calibración , Ingestión de Alimentos , Femenino , Mucosa Gástrica/metabolismo , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Variaciones Dependientes del Observador , Periodo Posprandial , Cintigrafía , Reproducibilidad de los Resultados , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA