Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Ultrasound Med Biol ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38969526

RESUMEN

OBJECTIVE: Dynamic Ultrasound Localization Microscopy (DULM) has first been developed for non-invasive Pulsatility measurements in the rodent brain. DULM relies on the localization and tracking of microbubbles (MBs) injected into the bloodstream, to obtain highly resolved velocity and density cine-loops. Previous DULM techniques required ECG-gating, limiting its application to specific datasets, and increasing acquisition time. The objective of this study is to eliminate the need for ECG-gating in DULM experiments by introducing a motion-matching method for time registration. METHODS: We developed a motion-matching algorithm based on tissue Doppler that leverages the cyclic tissue motion within the brain. Tissue Doppler was estimated for each group of frames in the acquisitions, at multiple locations identified as local maxima in the skin above the skull. Subsequently, each group of frames was time-registered to a reference group by delaying it based on the maximum correlation value between their respective tissue Doppler signals. This synchronization ensured that each group of frames aligned with the brain tissue motion of the reference group, and consequently, with its cardiac cycle. As a result, velocities of MBs could be averaged to retrieve flow velocity variations over time. RESULTS: Initially validated in ECG-gated acquisitions in a rat model (n = 1), the proposed method was successfully applied in a mice model in 2D (n = 3) and in a feline model in 3D (n = 1). Performing time-registration with the proposed motion-matching method or by using ECG-gating leads to similar results. For the first time, dynamic velocity and density cine-loops were extracted without the need for any information on the animal ECG, and complex dynamic markers such as the Pulsatility index were estimated. CONCLUSION: Results suggest that DULM can be performed without external gating, enabling the use of DULM on any ULM dataset where enough MBs are detectable. Time registration by motion-matching represents a significant advancement in DULM techniques, making DULM more accessible by simplifying its experimental complexity.

2.
Phys Med Biol ; 69(4)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38181421

RESUMEN

A rise in blood flow velocity variations (i.e. pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with large penetration depth and high spatiotemporal resolution. The development of dynamic ultrasound localization microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures only 2D-projected and hence biased velocities . Herein, we present 3D DULM: using a single ultrasound scanner at high frame rate (1000-2000 Hz), this method can produce dynamic maps of microbubbles flowing in the bloodstream and extract quantitative pulsatility measurements in the cat brain with craniotomy and in the mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, which could be mapped with ultrasound down to a few tens of micrometers for the first time. We also performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the brain, which could be linked to early signs of neurodegenerative diseases.


Asunto(s)
Microscopía , Enfermedades Neurodegenerativas , Animales , Ratones , Microscopía/métodos , Ultrasonografía/métodos , Arterias , Hemodinámica
3.
Commun Biol ; 6(1): 667, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37353519

RESUMEN

Our daily endeavors occur in a complex visual environment, whose intrinsic variability challenges the way we integrate information to make decisions. By processing myriads of parallel sensory inputs, our brain is theoretically able to compute the variance of its environment, a cue known to guide our behavior. Yet, the neurobiological and computational basis of such variance computations are still poorly understood. Here, we quantify the dynamics of sensory variance modulations of cat primary visual cortex neurons. We report two archetypal neuronal responses, one of which is resilient to changes in variance and co-encodes the sensory feature and its variance, improving the population encoding of orientation. The existence of these variance-specific responses can be accounted for by a model of intracortical recurrent connectivity. We thus propose that local recurrent circuits process uncertainty as a generic computation, advancing our understanding of how the brain handles naturalistic inputs.


Asunto(s)
Corteza Visual Primaria , Corteza Visual , Corteza Visual/fisiología , Neuronas/fisiología , Encéfalo
4.
Vision (Basel) ; 6(4)2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-36278674

RESUMEN

A study was conducted to determine stable cortical contrast response functions (CRFs) accurately and repeatedly in the shortest possible experimentation time. The method consisted of searching for experimental temporal aspects (number and duration of trials and number and distribution of contrasts used) with a model based on inhomogeneous Poisson spike trains to varying contrast levels. The set of values providing both short experimental duration and maximizing fit of the CRFs were saved, and then tested on cats' visual cortical neurons. Our analysis revealed that 4 sets of parameters with less or equal to 6 experimental visual contrasts satisfied our premise of obtaining good CRFs' performance in a short recording period, in which the number of trials seems to be the experimental condition that stabilizes the fit.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA