Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Scand J Gastroenterol ; 59(8): 925-932, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38950889

RESUMEN

OBJECTIVES: Recently, artificial intelligence (AI) has been applied to clinical diagnosis. Although AI has already been developed for gastrointestinal (GI) tract endoscopy, few studies have applied AI to endoscopic ultrasound (EUS) images. In this study, we used a computer-assisted diagnosis (CAD) system with deep learning analysis of EUS images (EUS-CAD) and assessed its ability to differentiate GI stromal tumors (GISTs) from other mesenchymal tumors and their risk classification performance. MATERIALS AND METHODS: A total of 101 pathologically confirmed cases of subepithelial lesions (SELs) arising from the muscularis propria layer, including 69 GISTs, 17 leiomyomas and 15 schwannomas, were examined. A total of 3283 EUS images were used for training and five-fold-cross-validation, and 827 images were independently tested for diagnosing GISTs. For the risk classification of 69 GISTs, including very-low-, low-, intermediate- and high-risk GISTs, 2,784 EUS images were used for training and three-fold-cross-validation. RESULTS: For the differential diagnostic performance of GIST among all SELs, the accuracy, sensitivity, specificity and area under the receiver operating characteristic (ROC) curve were 80.4%, 82.9%, 75.3% and 0.865, respectively, whereas those for intermediate- and high-risk GISTs were 71.8%, 70.2%, 72.0% and 0.771, respectively. CONCLUSIONS: The EUS-CAD system showed a good diagnostic yield in differentiating GISTs from other mesenchymal tumors and successfully demonstrated the GIST risk classification feasibility. This system can determine whether treatment is necessary based on EUS imaging alone without the need for additional invasive examinations.


Asunto(s)
Aprendizaje Profundo , Diagnóstico por Computador , Endosonografía , Neoplasias Gastrointestinales , Tumores del Estroma Gastrointestinal , Curva ROC , Humanos , Diagnóstico Diferencial , Tumores del Estroma Gastrointestinal/diagnóstico por imagen , Tumores del Estroma Gastrointestinal/patología , Tumores del Estroma Gastrointestinal/diagnóstico , Neoplasias Gastrointestinales/diagnóstico por imagen , Neoplasias Gastrointestinales/diagnóstico , Femenino , Persona de Mediana Edad , Masculino , Anciano , Adulto , Medición de Riesgo , Sensibilidad y Especificidad , Anciano de 80 o más Años
2.
J Gastroenterol Hepatol ; 39(4): 740-745, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38229203

RESUMEN

BACKGROUND AND AIM: Stereomicroscopic on-site evaluation (SOSE) is a rapid evaluation method for endoscopic ultrasound-guided tissue acquisition (EUS-TA) with a high diagnostic sensitivity when the stereomicroscopically visible white core (SVWC) cut-off value (≥ 11 mm) is met. We prospectively examined the association between SVWCs and the adequacy of tissue specimens, assuming subsequent comprehensive genome profiling (CGP). METHODS: This study included 66 consecutive patients with suspected unresectable pancreatic cancer who underwent EUS-TA. The primary endpoint was the frequency of combined samples with ≥ 20% tumor cell content that met over twice the SVWC (T-SVWC) cut-off value, achieved through multiple punctures. The secondary endpoints were the number of punctures, the percentage of SVWC cut-off values, adverse events, the positive diagnosis rate, and the tissue section area. RESULTS: The median number of EUS-TA punctures for suspected unresectable pancreatic cancer was 3 (range, 3-4); SVWC and T-SVWC cut-off values were obtained in 171/206 specimens and 65/66 patients, respectively. There were no EUS-TA-related adverse events. The positive diagnosis rate of EUS-TA was 95.5%. Among the 63 patients meeting the T-SVWC cut-off value in pathological diagnoses, the median tumor cell content was 40% (range, 5-80%), with 57 patients having tumor cell content ≥ 20%. The median tissue section area was 15 (range, 3-40) mm2. CONCLUSIONS: When performing EUS-TA for unresectable pancreatic cancer with the intention of subsequent CGP, obtaining a high tumor cell content (≥ 20%) by assessing the T-SVWC cut-off value via SOSE may serve as a novel indicator for on-site estimation of CGP suitability for EUS-TA specimens.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Pancreáticas , Humanos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/genética , Endosonografía , Microscopía
3.
Dig Dis Sci ; 69(7): 2567-2572, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38750279

RESUMEN

BACKGROUND: The cutoff value for stereomicroscopic on-site evaluation (SOSE) in endoscopic ultrasound-guided tissue acquisition (EUS-TA) has high diagnostic sensitivity when a Franseen needle is employed for upper gastrointestinal subepithelial lesions (SELs) (stereomicroscopically visible white core [SVWC] ≥ 4 mm). AIM: We aimed to determine whether high diagnostic sensitivity could be obtained when EUS-TA was performed using a Fork-tip needle. METHODS: Twenty-one patients were prospectively registered. Patients underwent EUS-TA using a Fork-tip needle for upper gastrointestinal SELs at Kitasato University Hospital between January and November 2022. Punctures were made twice using the needle, and SOSE was conducted for each specimen. Blood and physical examination were performed to assess adverse events. Pathological diagnosis was made using hematoxylin and eosin-stained sections and immunohistochemical staining. Statistical comparisons were completed using Fisher's exact tests. RESULTS: The diagnostic rate of EUS-TA was 100% (21/21 cases). The final diagnosis was gastrointestinal stromal tumor in 17 (81.0%) and leiomyoma in 4 (19.0%) patients. SOSE was conducted on all 42 punctures, and the tissue sampling rate was 100% (42/42 punctures). Specimens with SVWC ≥ 4 mm were collected in 97.6% punctures (41/42 punctures) and the diagnostic sensitivity for these specimens was 100% (41/41 punctures), which is significantly higher (p < 0.0238) compared to the absence of cutoff value (diagnostic sensitivity of 0%). No EUS-TA-related adverse events occurred. CONCLUSIONS: EUS-TA combined with SOSE for upper gastrointestinal SEL using a fork-tip needle had a high diagnostic rate, and the cutoff value of SVWC ≥ 4 mm had high diagnostic sensitivity.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Gastrointestinales , Tumores del Estroma Gastrointestinal , Agujas , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Tumores del Estroma Gastrointestinal/patología , Tumores del Estroma Gastrointestinal/diagnóstico por imagen , Tumores del Estroma Gastrointestinal/diagnóstico , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Adulto , Estudios Prospectivos , Neoplasias Gastrointestinales/patología , Neoplasias Gastrointestinales/diagnóstico , Neoplasias Gastrointestinales/diagnóstico por imagen , Leiomioma/patología , Leiomioma/diagnóstico por imagen , Anciano de 80 o más Años
4.
Pancreatology ; 22(2): 311-316, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34969602

RESUMEN

OBJECTIVE: In sample isolation processing by stereomicroscopy (SIPS), a technique used to assess the quality of specimens collected during endoscopic ultrasound (EUS)-guided tissue acquisition (EUS-TA), the cutoff value of stereomicroscopically visible white core (SVWC) (≥11 mm) indicates high diagnostic sensitivity. However, the procedure of SIPS is complicated and time-consuming. Therefore, we devised the stereomicroscopic on-site evaluation (SOSE), a new rapid assessment method that is simpler than SIPS and only determines if the SVWC cutoff value is attained. We aimed to examine the usefulness of SOSE in a multicenter, prospective setting. METHODS: Seventy patients from multiple institutions with solid pancreatic masses suspected to be pancreatic cancer were included. EUS-TA was performed using a 22-gauge Franseen needle. SVWCs were measured on-site using stereomicroscopy. The primary outcome was the sensitivity of SVWC cutoff value in EUS-TA with SOSE. RESULTS: The total number of punctures was 214 and SOSE was performed on 150 punctures. The SVWC cutoff value collection rate was 100% per lesion, with 80% in the first pass, 79% in the second pass, and 78% per puncture in all passes. The median time taken to determine the SVWC cutoff value for SOSE was 47 s. The sensitivity of the SVWC cutoff value was 93.2% for histology and 96.6% for cytology + histology. The per-lesion accuracy of pathological diagnosis reached the highest level (98.6%) at the second puncture. CONCLUSIONS: SOSE showed high diagnostic sensitivity and may be a new rapid assessment method for the diagnosis of malignant pancreatic cancer using EUS-TA.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Pancreáticas , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Endosonografía/métodos , Humanos , Agujas , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Estudios Prospectivos
5.
J Hepatobiliary Pancreat Sci ; 31(1): 25-33, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37817303

RESUMEN

BACKGROUND: Post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP) is more common in patients with asymptomatic common bile duct stones (CBDSs) and normal anatomy than in those with symptomatic CBDS; however, studies on the effect of surgically altered anatomy are lacking. We aimed to investigate whether asymptomatic CBDS in balloon enteroscopy-assisted ERCP cases for surgically altered anatomy also has a high incidence of PEP and analyze the risk factors for PEP. METHODS: We retrospectively analyzed 108 consecutive patients who underwent initial ERCP for CBDS with surgically altered anatomies and with naive papilla at Kitasato University Hospital from April 2015 to December 2022. RESULTS: Study participants were as follows: 92 (85%) patients with symptomatic CBDS and 16 (15%) patients asymptomatic CBDS. The overall bile duct cannulation success rate was 89.8%, with PEP occurring in 7.4% of patients (symptomatic CBDS: 3.3%, asymptomatic CBDS: 31.3%). PEP incidence was significantly higher for asymptomatic CBDS (p = .0017). Multivariate analysis identified asymptomatic CBDS and precut sphincterotomy as significant risk factors for PEP. CONCLUSIONS: Asymptomatic CBDS may be a risk factor for PEP onset in balloon enteroscopy-assisted ERCP with surgically altered anatomy. Therefore, the procedure should be performed after obtaining sufficient informed consent and adequate preparation.


Asunto(s)
Cálculos Biliares , Pancreatitis , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Pancreatitis/epidemiología , Pancreatitis/etiología , Cálculos Biliares/diagnóstico por imagen , Cálculos Biliares/etiología , Cálculos Biliares/cirugía , Conducto Colédoco
6.
Clin Endosc ; 57(1): 89-95, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37070203

RESUMEN

BACKGROUND/AIMS: In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs). METHODS: In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA's diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs. RESULTS: The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture. CONCLUSION: Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.

7.
Clin Endosc ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38919058

RESUMEN

Background/Aims: To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC). Methods: Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings. Results: We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively. Conclusions: The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.

8.
Intern Med ; 62(19): 2783-2793, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-36792197

RESUMEN

Objective The effect of sarcopenia on the prognosis of patients undergoing chemotherapy for unresectable pancreatic ductal adenocarcinoma remains largely unexplored. In this retrospective study, we investigated the relationship between sarcopenia and the prognosis of patients receiving first-line nanoparticle albumin-bound paclitaxel plus gemcitabine for unresectable pancreatic ductal adenocarcinoma. Methods We enrolled 251 patients with unresectable metastatic or locally advanced pancreatic ductal adenocarcinoma who had received chemotherapy between January 2015 and December 2020 at Kitasato University Hospital. Univariate and multivariate analyses were performed using the stratified Cox proportional hazards model to determine variables significantly associated with the progression-free and overall survival. Propensity score matching was performed to mitigate selection bias effects. Results In the propensity score-matched cohort, the progression-free and overall survival were not significantly different between the sarcopenia and non-sarcopenia groups (p=0.335, and 0.679 respectively). The skeletal muscle index decreased by 4.4% and 6.5% in the sarcopenia and non-sarcopenia groups, respectively, during the early treatment phase (p=0.084). There were no significant differences between groups with regard to major adverse events or drug toxicity occurrences. Both the progression-free and overall survival were significantly shorter in the skeletal muscle index loss group than in the non-skeletal muscle index loss group (p=0.026 and 0.045, respectively). Conclusion Skeletal muscle index loss during the initial treatment phase may be an early marker for the long-term prognosis of patients receiving nanoparticle albumin-bound paclitaxel plus gemcitabine as first-line treatment for unresectable pancreatic ductal adenocarcinoma.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Sarcopenia , Humanos , Desoxicitidina/efectos adversos , Sarcopenia/etiología , Estudios Retrospectivos , Paclitaxel Unido a Albúmina/uso terapéutico , Neoplasias Pancreáticas/complicaciones , Neoplasias Pancreáticas/tratamiento farmacológico , Carcinoma Ductal Pancreático/complicaciones , Carcinoma Ductal Pancreático/tratamiento farmacológico , Gemcitabina , Pronóstico , Paclitaxel/efectos adversos , Albúminas/uso terapéutico , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/patología , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Neoplasias Pancreáticas
9.
Cardiovasc Interv Ther ; 32(4): 425-429, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28028747

RESUMEN

An 81-year-old male with severe symptomatic aortic stenosis with ventricular tachycardia was referred for treatment. Balloon aortic valvuloplasty was performed under cardiopulmonary resuscitation. Though transcatheter aortic valve implantation (TAVI) was considered high risk for annulus rupture and aortic regurgitation due to annular calcification, TAVI was performed because of extremely high surgical risk. Moderate-to-severe aortic regurgitation (AR) remained and progression of acidosis could not be managed with continuous hemodiafiltration. His autopsy revealed the development of non-occlusive mesenteric ischemia (NOMI) as the cause of progressive acidosis. AR and hemodynamic instability might contribute to the development and progression of NOMI after TAVI.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Isquemia Mesentérica/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Acidosis/etiología , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Valvuloplastia con Balón , Reanimación Cardiopulmonar , Resultado Fatal , Humanos , Masculino , Taquicardia Ventricular/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA