Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
1.
J Vasc Interv Radiol ; 35(7): 972-978, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38663514

RESUMEN

PURPOSE: To examine the natural history of splenic artery aneurysms (SAAs) at a single institution and assess the effect of patient factors and aneurysm characteristics on aneurysm growth. MATERIALS AND METHODS: This single-center retrospective study included patients with SAAs who underwent serial imaging over 30 years (1990-2020). Data regarding patient demographics and aneurysm characteristics were collected. The variables contributing to aneurysm growth were assessed using nonparametric tests for continuous variables and chi-square test for categorical variables. Multivariable linear regression was performed using aneurysm growth rate as a continuous dependent variable. RESULTS: A total of 132 patients were included in this study. The median maximum diameter of the SAAs was 15.8 mm (range, 4.0-50.0 mm). Growth over time was observed in 39% of the aneurysms, whereas the remaining 61% were stable in size. Of aneurysms that increased in size, the median aneurysm growth rate was 0.60 mm/y (range, 0.03-5.00 mm/y). Maximum aneurysm diameter of >2 cm and the presence of >50% mural thrombus were significant positive predictors for aneurysm growth (P = .020 and P = .022, respectively). Greater than 50% rim calcification was a significant negative predictor for aneurysm growth (P = .009) in multivariate analysis. CONCLUSIONS: A larger baseline SAA size, presence of mural thrombus, and lack of rim calcification are associated with increased aneurysm growth rate.


Asunto(s)
Aneurisma , Progresión de la Enfermedad , Arteria Esplénica , Humanos , Arteria Esplénica/diagnóstico por imagen , Aneurisma/diagnóstico por imagen , Estudios Retrospectivos , Femenino , Masculino , Persona de Mediana Edad , Factores de Riesgo , Anciano , Adulto , Factores de Tiempo , Valor Predictivo de las Pruebas , Anciano de 80 o más Años , Calcificación Vascular/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Adulto Joven , Trombosis/diagnóstico por imagen , Trombosis/etiología , Medición de Riesgo
2.
J Vasc Interv Radiol ; 33(11): 1321-1328.e1, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35863632

RESUMEN

PURPOSE: To investigate the relationship between anatomic factors and primary patency of brachiocephalic arteriovenous fistulae (AVFs) after stent graft (SG) placement for cephalic arch stenosis (CAS). MATERIALS AND METHODS: This retrospective study reviewed all cephalic arch SGs placed in brachiocephalic AVFs in a tertiary academic medical center between 2014 and 2017. Sixty-three patients were included in the study. The mean patient age at the time of SG placement was 62.6 years ± 19, and the mean patient follow-up was 1,994 days ± 353. A cohort of patients (n = 31) who underwent brachiocephalic fistulograms for CAS but only received percutaneous transluminal angioplasty (PTA) was the control group. Patient demographic characteristics, AVF anatomy, SG type, and clinical outcomes were reviewed. The duration of primary cephalic arch patency after SG placement was compared with that after previous PTA. RESULTS: The median AVF age at the time of data retrieval was 345 days. The primary patency of CAS after SG placement at 6 months, 12 months, and 3 years was 64%, 49.9%, and 23.5%, respectively. Primary cephalic arch patency was significantly associated with the SG diameter (P = .007) but not with cephalic vein-axillary vein junction anatomy, size of feeding artery, or SG length (P > .05). The primary patency of CAS in patients treated with PTA only (n = 31) at 6 months, 12 months, and 3 years was 61%, 35%, and 0%, respectively, which was significantly lower than that in patients treated with SG placement (P = .01). CONCLUSIONS: This study showed that the primary patency of CAS after SG placement was significantly higher than that of PTA-only treatment. Moreover, primary cephalic arch patency after SG placement was significantly associated with the SG diameter.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Humanos , Derivación Arteriovenosa Quirúrgica/efectos adversos , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Grado de Desobstrucción Vascular , Constricción Patológica/etiología , Estudios Retrospectivos , Diálisis Renal/efectos adversos , Resultado del Tratamiento , Stents
3.
AJR Am J Roentgenol ; 217(5): 1141-1152, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33594907

RESUMEN

BACKGROUND. Primary colon cancer location affects survival of patients with metastatic colorectal cancer (mCRC). Outcomes based on primary tumor location after salvage hepatic radioembolization with 90Y resin microspheres are not well studied. OBJECTIVE. The objectives of this study are to assess the survival outcomes of patients with advanced chemorefractory mCRC treated with 90Y radioembolization, as stratified by primary tumor location, and to explore potential factors that are predictive of survival. METHODS. A total of 99 patients who had progressive mCRC liver metastases while receiving systemic therapy and who were treated with 90Y radioembolization at a single center were retrospectively analyzed. For 89 patients, tumor response on the first imaging follow-up examination (CT or MRI performed at a mean [± SD] of 1.9 ± 0.9 months after 90Y radioembolization) was evaluated using RECIST. Overall survival (OS), OS after 90Y radioembolization, and hepatic progression-free survival (PFS) were calculated using the Kaplan-Meier method. Outcomes and associations of outcomes with tumor response were compared between patients with left- and right-sided tumors. RESULTS. A total of 74 patients had left-sided colon cancer, and 25 patients had right-sided colon cancer. Median OS from the time of mCRC diagnosis was 37.2 months, median OS after 90Y radioembolization was 5.8 months, and median hepatic PFS was 3.3 months. Based on RECIST, progressive disease on first imaging follow-up was observed in 38 patients (43%) after 90Y radioembolization and was associated with shorter OS after 90Y radioembolization compared with observation of disease control on first imaging follow-up (4.0 vs 10.5 months; p < .001). Patients with right-sided primary tumors showed decreased median OS after 90Y radioembolization compared with patients with left-sided primary tumors (5.4 vs 6.2 months; p = .03). Right- and left-sided primary tumors showed no significant difference in RECIST tumor response, hepatic PFS, or extrahepatic disease progression (p > .05). Median survival after 90Y radioembolization was significantly lower among patients with progressive disease than among those with disease control in the group with left-sided primary tumors (4.2 vs 13.9 months; p < .001); however, this finding was not observed in the group with right-sided primary tumors (3.3 vs 7.2 months; p = .05). CONCLUSION. Right-sided primary tumors were independently associated with decreased survival among patients with chemorefractory mCRC after 90Y radioembolization, despite these patients having a similar RECIST tumor response, hepatic PFS, and extrahepatic disease progression compared with patients with left-sided primary tumors. CLINICAL IMPACT. Primary colon cancer location impacts outcomes after salvage 90Y radioembolization and may help guide patient selection.


Asunto(s)
Neoplasias Colorrectales/patología , Embolización Terapéutica/métodos , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/terapia , Terapia Recuperativa/métodos , Radioisótopos de Itrio/uso terapéutico , Anciano , Neoplasias Colorrectales/mortalidad , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Neoplasias Hepáticas/mortalidad , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Criterios de Evaluación de Respuesta en Tumores Sólidos , Terapia Recuperativa/efectos adversos
4.
Radiology ; 294(1): 5-17, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31746691

RESUMEN

Imaging and image-guided procedures play an imperative role in the screening, diagnosis, and surveillance of cancer. Although emerging imaging techniques now enable more precise molecular characterization of tumors, multigenetic tumor profiling for targeted therapeutic selection remains limited to direct tissue acquisition. Even in the context of targeted therapy, tumors adapt to acquire resistance. This necessitates serial monitoring, traditionally through tissue acquisition, to identify the molecular mechanism of resistance and to guide second-line therapy. An alternative to tissue acquisition is the collection of circulating tumor markers such as cell-free nucleic acids and circulating tumor cells in the peripheral blood. This noninvasive diagnostic approach is referred to as the liquid biopsy. The liquid biopsy is currently used clinically for therapeutic guidance when tissue acquisition is impossible or when the specimen is inadequate. It is also being studied in the context of screening, diagnosis, and surveillance. As cancer treatment continues to move toward a focus on precision medicine, this developing technology may alter and/or augment the role of imaging in the management of cancer. This review aims to outline the use of liquid biopsy in cancer and its potential impact on diagnostic imaging and image-guided procedures.


Asunto(s)
Neoplasias/patología , Humanos , Biopsia Líquida
6.
J Vasc Interv Radiol ; 30(7): 1089-1097, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31147241

RESUMEN

PURPOSE: To evaluate effectiveness of the polytetrafluoroethylene-covered nitinol mesh microvascular plug (MVP) and compare it with other devices in pulmonary arteriovenous malformation (PAVM) embolization in patients with hereditary hemorrhagic telangiectasia (HHT). MATERIALS AND METHODS: Twenty-five patients (average age 35 y; range, 15-56 y) with hereditary hemorrhagic telangiectasia (HHT) and de novo PAVM embolization with at least 1 MVP between November 2015 and May 2017 were retrospectively evaluated. Retrospective data were also obtained from prior embolization procedures in the same patient population with other embolic devices dating back to 2008. Technical success, complications, PAVM persistence rates, and category of persistence were analyzed. RESULTS: In 25 patients, 157 PAVMs were treated: 92 with MVP, 35 with AMPLATZER vascular plug (AVP), 6 with AVP plus coils, and 24 with coils. The per-PAVM technical success rates were 100% with MVP; 97%, AVP; 100%, AVP plus coils; and 100%, coils. PAVM persistence rates and median follow-up were as follows: MVP, 2% (1/92) (510 d); AVP, 15% (3/20) (1,447 d); AVP plus coils, 20% (1/5) (1,141 d); coils, 46.7% (7/15) (1,141 d). Persistence owing to recanalization for MVP, AVP, AVP plus coils, and coils was 2%, 15%, 0%, and 33%. No difference was found between persistence rates of MVP vs AVP (P = .098). Embolization with a vascular plug (MVP or AVP) with or without coils had a statistically significant lower persistence rate (5.4%) than embolization with coils alone (46.7%) (P = .022). CONCLUSIONS: PAVM embolization with MVP had a high technical success rate and a low persistence rate comparable to AVP and lower than coil embolization alone.


Asunto(s)
Aleaciones , Malformaciones Arteriovenosas/terapia , Materiales Biocompatibles Revestidos , Embolización Terapéutica/instrumentación , Politetrafluoroetileno , Arteria Pulmonar/anomalías , Venas Pulmonares/anomalías , Telangiectasia Hemorrágica Hereditaria/terapia , Adolescente , Adulto , Malformaciones Arteriovenosas/diagnóstico por imagen , Malformaciones Arteriovenosas/fisiopatología , Embolización Terapéutica/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Telangiectasia Hemorrágica Hereditaria/diagnóstico por imagen , Telangiectasia Hemorrágica Hereditaria/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
8.
AJR Am J Roentgenol ; 211(3): 672-676, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30016144

RESUMEN

OBJECTIVE: Pulmonary embolism (PE) is associated with a higher mortality rate in patients with congestive heart failure (CHF) than in those without heart failure. The purpose of this study was to evaluate if inferior vena cava (IVC) filter placement provides any mortality benefit in patients admitted with CHF and PE. MATERIALS AND METHODS: The 2005-2014 Nationwide Inpatient Sample (NIS) was used for this study. Adults (≥ 18 years old) with PE were identified using International Classification of Diseases, 9th revision, Clinical Modification (ICD-9-CM) diagnosis codes. Patients with CHF were identified using the Elixhauser comorbidity variable (CM_CHF) in the NIS database. IVC filter placement was identified using the ICD-9-CM procedure code 38.7 (interruption of the vena cava). A multivariate logistic regression model was used to determine the association of IVC filter placement with in-hospital mortality. The model was adjusted for demographics, hospital characteristics, comorbidities, and PE severity indexes (pressor dependence, mechanical ventilation, nonseptic shock, and use of thrombolytic therapy). RESULTS: During the study years, 425,877 patients with a comorbidity of CHF were hospitalized with PE (44% male; mean age, 71.5 years old). Of them, 67,237 patients (15.8%) received an IVC filter during the admission, and 50,338 (11.8%) died during the hospital stay. The all-cause in-hospital mortality rate among patients who received an IVC filter was 9.7% (6541 of 67,237 patients) compared with 12.2% (43,796 of 358,638 patients) among those without an IVC filter (p < 0.001), with an absolute risk reduction of 2.5%. The multivariate adjusted hazard ratio of in-hospital mortality associated with IVC filter placement was 0.535 (95% CI, 0.518-0.551; p < 0.001). CONCLUSION: A lower all-cause mortality rate was observed in patients with CHF and PE who received an IVC filter while hospitalized. In the absence of data from randomized controlled trials, this study suggests that IVC filters could help prevent in-hospital death among patients admitted with PE and CHF.


Asunto(s)
Insuficiencia Cardíaca/mortalidad , Embolia Pulmonar/mortalidad , Filtros de Vena Cava , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Mortalidad Hospitalaria , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/etiología , Embolia Pulmonar/terapia , Tasa de Supervivencia , Resultado del Tratamiento , Adulto Joven
9.
J Vasc Interv Radiol ; 28(1): 78-87, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27884687

RESUMEN

Whole-blood viscoelastic testing can identify patient-specific coagulation disturbances, allowing for targeted repletion of necessary coagulation factors and differentiation between coagulopathy and surgical bleeding that requires intervention. Viscoelastic testing complements standard coagulation tests and has been shown to decrease transfusion requirements and improve survival in bleeding patients. Viscoelastic testing also can be used to predict bleeding and improve the care of patients undergoing interventional radiology (IR) procedures.


Asunto(s)
Trastornos de la Coagulación Sanguínea/diagnóstico , Pruebas de Coagulación Sanguínea/métodos , Coagulación Sanguínea , Pérdida de Sangre Quirúrgica/prevención & control , Viscosidad Sanguínea , Hemorragia/prevención & control , Radiografía Intervencional/métodos , Trastornos de la Coagulación Sanguínea/sangre , Trastornos de la Coagulación Sanguínea/complicaciones , Trastornos de la Coagulación Sanguínea/terapia , Elasticidad , Hemorragia/sangre , Hemorragia/etiología , Humanos , Valor Predictivo de las Pruebas , Radiografía Intervencional/efectos adversos , Reproducibilidad de los Resultados , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
J Vasc Interv Radiol ; 28(10): 1371-1377, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28689934

RESUMEN

PURPOSE: To compare overall survival and toxicities after yttrium-90 (90Y) radioembolization and chemoembolization with drug-eluting embolics (DEE) in patients with infiltrative hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Retrospective review of 50 patients with infiltrative HCC without main portal vein invasion who were treated with 90Y radioembolization (n = 26) or DEE chemoembolization (n = 24) between March 2007 and August 2012 was completed. Infiltrative tumors were defined by cross-sectional imaging as masses that lacked well-demarcated boundaries, and treatment allocations were made by a multidisciplinary tumor board. Median age was 63 years; median tumor diameter was 9.0 cm; and there were no significant differences between groups in performance status, severity of liver disease, or HCC stage. Toxicities were graded by Common Terminology Criteria for Adverse Events v4.03. Overall survival from treatment was assessed by Kaplan-Meier analysis, with analysis of potential predictors of survival with log-rank test. RESULTS: There was no difference in the average number of procedures performed in each treatment group (DEE, 1.5 ± 1.1; 90Y, 1.6 ± 0.5; P = .97), and technical success was achieved in all cases. Abdominal pain (73% vs 33%; P = .004) and fever (38% vs 8%; P = .01) were more frequent after DEE chemoembolization. There was no significant difference in median overall survival between treatment groups after treatment (DEE, 9.9 months; 90Y, 8.1 months; P = .11). CONCLUSIONS: 90Y radioembolization and DEE chemoembolization provided similar overall survival in the treatment of infiltrative HCC without main portal vein invasion. Abdominal pain and fever were more frequent after DEE chemoembolization.


Asunto(s)
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Biopsia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Quimioembolización Terapéutica , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Radiofármacos , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Radioisótopos de Itrio
11.
Radiographics ; 37(1): 346-357, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27689831

RESUMEN

Noninvasive physiologic vascular studies play an important role in the diagnosis and characterization in peripheral arterial disease (PAD) of the lower extremity. These studies evaluate the physiologic parameters of blood flow through segmental arterial pressures, Doppler waveforms, and pulse volume recordings. Collectively, they comprise a powerful toolset for defining the functionality of the arterial system, localizing the site of disease, and providing prognostic data. This technology has been widely adopted by diverse medical specialty practitioners, including radiologists, surgeons, cardiologists, and primary care providers. The use of these studies increased substantially between 2000 and 2010. Although they do not employ imaging, they remain a critical component for a comprehensive radiologic vascular laboratory. A strong presence of radiology in the diagnosis of PAD adds value in that radiologists have shifted to noninvasive alternatives to diagnostic catheter angiography (DCA), such as computed tomography (CT) and magnetic resonance (MR) angiography, which provide a more efficient, less-expensive, and lower-risk alternative. Other specialties have increased the use of DCA during the same period. The authors provide a review of the relevant anatomy and physiology of PAD as well as the associated clinical implications. In addition, guidelines for interpreting the ankle-brachial index, segmental pressures, Doppler waveforms, and pulse volume recordings are reviewed as well as potential limitations of these studies. Noninvasive physiologic vascular studies are provided here for review with associated correlating angiographic, CT, and/or MR findings covering the segmental distribution of PAD as well as select nonatherosclerotic diagnoses. ©RSNA, 2016.


Asunto(s)
Angiografía/normas , Cateterismo Periférico/normas , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Guías de Práctica Clínica como Asunto , Radiología/normas , Cardiología/normas , Humanos , Estados Unidos
12.
J Comput Assist Tomogr ; 41(2): 289-293, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27824665

RESUMEN

PURPOSE: Treatment response to drug-eluting bead chemoembolization (DEB-TACE) is well established for patients with hepatocellular carcinoma (HCC); however, few studies have evaluated tumor imaging characteristics associated with treatment responses. The aim of our study was to identify imaging characteristics associated with treatment responses and overall survival after DEB-TACE of HCC. METHODS: This is a retrospective cohort study of 33 tumors in 32 patients who underwent DEB-TACE for inoperable HCC in a single, large academic medical center. Arterial phase computed tomography data were reviewed to assess tumor size, edge characteristics, tumor enhancement on pixel density histogram, and heterogeneity using coefficient of variation. We assessed correlation between these markers of tumor morphology and response to DEB-TACE using mRECIST criteria, progression-free survival, and overall survival. RESULTS: Tumor heterogeneity (P = 0.01) and tumor enhancement greater than 50% (P = 0.05) were significantly associated with complete response to DEB-TACE in patients with HCC; however, neither was associated with overall or progression-free survival. Tumor size and edge characteristics were not associated with complete response to DEB-TACE, although tumor size greater than 6 cm was associated with worse overall survival (hazard ratio, 3.349; P = 0.02). CONCLUSIONS: Tumor heterogeneity and enhancement on arterial phase imaging may be predictive markers of treatment response to DEB-TACE among patients with HCC.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/instrumentación , Quimioembolización Terapéutica/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Adulto , Anciano , Estudios de Cohortes , Supervivencia sin Enfermedad , Doxorrubicina , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
13.
Vasa ; 46(2): 121-126, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28247824

RESUMEN

BACKGROUND: The long term efficacy of endovascular recanalization for chronic iliocaval occlusion secondary to inferior vena cava (IVC) filters is unknown. The purpose of this study was to evaluate the effectiveness of endovascular recanalization and stent placement across the filter in patients with filter-associated chronic iliocaval occlusion. PATIENTS AND METHODS: Seven patients (mean age 56 ± 15 yrs; seven males) with symptomatic chronic iliocaval occlusion and occluded IVC filter were included. Immediate technical success rate, long term clinical effectiveness of endovascular recanalization and patency rate of the stents were assessed. RESULTS: In all patients, the endovascular treatment consisted of percutaneous venous access, recanalization of the occluded iliac veins and the IVC, transluminal angioplasty and stenting of the infrarenal inferior vena cava and iliac veins with self-expanding stents. The IVC filter was not removed, but rather the stents were extended across the filter. In four of seven patients (57 %), adjunctive pharmaco-mechanical thrombolysis was performed. All patients received anticoagulation post procedure. The mean clinical follow-up was 51.1 ± 27 months. Technical success rate was 100 %. Clinical success rate with symptomatic improvement was 85.7 %; one patient developed post-thrombotic syndrome on long term follow-up despite initial symptomatic improvement. Poststenting, the primary patency rate was 85.7 % (six of seven patients) and the secondary patency rate was 100 % (seven of seven patients). CONCLUSIONS: Endovascular recanalization with balloon angioplasty and placement of a self-expanding stent across a chronically occluded IVC filer can be performed safely and effectively for patients with symptomatic iliocaval thrombosis. An adjunctive pharmacologic-mechanical thrombolysis may be considered for selected patients.


Asunto(s)
Procedimientos Endovasculares , Filtros de Vena Cava/efectos adversos , Vena Cava Inferior , Trombosis de la Vena/terapia , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Constricción Patológica , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flebografía/métodos , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/fisiopatología , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Trombosis de la Vena/fisiopatología
14.
J Vasc Interv Radiol ; 27(8): 1154-9, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27363298

RESUMEN

PURPOSE: To compare safety and effectiveness of intravascular ultrasound (US)-guided portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) creation with conventional TIPS technique. MATERIALS AND METHODS: In this retrospective study, TIPS creation using intravascular US guidance in 55 patients was compared with conventional TIPS creation in 54 patients by 10 operators over a 3-year period. Operators were classified as experienced if they had performed ≥ 20 TIPS procedures at the beginning of the study period. Time to portal vein access, total radiation dose, and needle pass-related capsular perforation were recorded. RESULTS: Baseline demographic characteristics of patients were similar (P > .05). Mean time to portal venous access was 46 minutes ± 37 for conventional TIPS and 31 minutes ± 19 for intravascular US-guided TIPS (P = .007). Intravascular US guidance allowed significantly shorter times (48 min ± 30 vs 28 min ± 16; P = .01) to portal vein access among operators (n = 5) with limited experience but failed to achieve any significant time savings (44 min ± 43 vs 34 min ± 22; P = .89) among experienced operators (n = 5). Needle pass-related capsular perforation occurred in 17/54 (34%) patients with conventional TIPS and 5/55 (9%) patients with intravascular US-guided TIPS (P = .004). Radiation dose was 2,376 mGy ± 1,816 for conventional TIPS and 1,592 mGy ± 1,263 for intravascular US-guided TIPS (P = .004). CONCLUSIONS: Intravascular US-guided portal vein access during TIPS creation is associated with shorter portal vein access times, decreased needle pass-related capsular perforations, and reduced radiation dose.


Asunto(s)
Hipertensión Portal/cirugía , Vena Porta/cirugía , Derivación Portosistémica Intrahepática Transyugular , Dosis de Radiación , Radiografía Intervencional , Ultrasonografía Intervencional , Medios de Contraste/administración & dosificación , Femenino , Fluoroscopía , Humanos , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/etiología , Hipertensión Portal/fisiopatología , Cirrosis Hepática/complicaciones , Cirrosis Hepática/diagnóstico , Masculino , Persona de Mediana Edad , Agujas , Tempo Operativo , Presión Portal , Vena Porta/diagnóstico por imagen , Vena Porta/fisiopatología , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Derivación Portosistémica Intrahepática Transyugular/instrumentación , Punciones , Exposición a la Radiación , Radiografía Intervencional/efectos adversos , Radiografía Intervencional/métodos , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos
16.
AJR Am J Roentgenol ; 207(6): W125-W132, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27610820

RESUMEN

OBJECTIVE: The purpose of this study was to compare the image quality of reduced-iodine-dose single-source dual-energy CT angiography (CTA) with that of standard-iodine-dose single-energy CTA in examinations of patients with abdominal aortic aneurysm and to assess the effect of the concentration of iodinated contrast medium on intravascular enhancement and image quality of reduced-iodine-dose CTA. SUBJECTS AND METHODS: In a prospective randomized clinical trial, 66 consecutively registered patients with abdominal aortic aneurysm who had previously undergone single-energy CTA (30-37 g I) underwent follow-up CTA at a reduced dose (21-27 g I) of iodinated contrast medium of either 270 mg I/mL (n = 33) or 320 mg I/mL (n = 33). Two readers independently evaluated virtual monochromatic imaging datasets (40-140 keV) and single-energy CTA images for image quality and noise and their preference for optimal energy virtual monochromatic imaging dataset. A value of p < 0.05 was considered statistically significant. RESULTS: All 66 dual-energy CTA examinations were rated diagnostic with mean image quality and image noise scores of 4.8 and 4.5 for reader 1 and 3.8 and 3.4 for reader 2 compared with single-energy CTA results of 4.5 and 4.2 for reader 1 and 4.5 and 4.1 for reader 2. Low-energy virtual monochromatic images (40-60 keV) from reduced-iodine-dose (28%) dual-energy CTA had significantly higher intravascular aortic attenuation (26-185%) and contrast-to-noise ratio (CNR) (20-25%) than standard-iodine-dose single-energy CTA images (p < 0.0001). No significant difference was found between patients who received 270 and those who received 320 mg I/mL with respect to intravascular aortic attenuation (p = 0.6331) or CNR (p = 0.9775). CONCLUSION: Low-energy virtual monochromatic imaging datasets from reduced-iodine (24 g I) single-source dual-energy CTA of the abdomen provide up to 185% higher attenuation and 25% higher CNR than standard-iodine-dose (33.3 g I) single-energy CTA while offering a wide range of energy settings irrespective of the concentration of IV contrast medium used.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Yodo/administración & dosificación , Exposición a la Radiación/análisis , Protección Radiológica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Anciano , Anciano de 80 o más Años , Aortografía/métodos , Medios de Contraste , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Exposición a la Radiación/prevención & control , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
18.
J Vasc Interv Radiol ; 26(4): 491-8.e1, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25636673

RESUMEN

PURPOSE: To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. MATERIALS AND METHODS: DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. RESULTS: IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. CONCLUSIONS: Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients.


Asunto(s)
Remoción de Dispositivos/normas , Embolia Pulmonar/prevención & control , Garantía de la Calidad de Atención de Salud/organización & administración , Mejoramiento de la Calidad/normas , Indicadores de Calidad de la Atención de Salud/organización & administración , Filtros de Vena Cava/normas , Adulto , Anciano , Anciano de 80 o más Años , Vías Clínicas/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos, Atención de Salud/normas , Adulto Joven
19.
AJR Am J Roentgenol ; 204(5): W592-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25905967

RESUMEN

OBJECTIVE: Ureteroarterial fistula (UAF) is an uncommon condition with only approximately 150 cases reported in the literature. Patients typically present with hematuria in the setting of prolonged ureteral stenting, prior pelvic surgery, malignancy, or radiation. Presentation can vary from intermittent hematuria to life-threatening hemorrhagic shock. CONCLUSION: Recognizing this condition in a prototypical patient is essential for accurate diagnosis and management. Angiography yields the highest diagnostic benefit, and arterial stent-graft placement is the treatment of choice.


Asunto(s)
Diagnóstico por Imagen , Fístula Urinaria/diagnóstico , Fístula Vascular/diagnóstico , Medios de Contraste , Diagnóstico Diferencial , Humanos , Fístula Urinaria/fisiopatología , Fístula Urinaria/terapia , Fístula Vascular/fisiopatología , Fístula Vascular/terapia
20.
J Vasc Interv Radiol ; 25(6): 847-51, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24657087

RESUMEN

PURPOSE: To evaluate the indications, complications, and clinical outcomes of transcatheter embolization for acute hemorrhage associated with gastric adenocarcinoma. MATERIALS AND METHODS: Ten patients underwent catheter-directed arterial embolization at two institutions for acute gastrointestinal hemorrhage related to pathology-proven gastric adenocarcinoma from March 2002 to March 2012. The electronic medical record for each patient was reviewed for clinical presentation, endoscopy history, procedural complications, and long-term follow-up results. RESULTS: Between March 2002 and March 2012, 10 patients (eight men; mean age, 61.1 y ± 15.3) underwent transcatheter arterial embolization for gastrointestinal hemorrhage caused by gastric adenocarcinoma. Endoscopic therapy had failed in all patients before embolization. Embolization involving branches of the left gastric artery was performed in all patients. No deaths or complications related to the procedure were identified. Mean survival was 301 days, but with a wide range, from 1 day to 1,852 days and counting. Those with unresectable disease (n = 7; 70%) had a median survival time of 9 days, significantly worse (P < .01) than those with resectable disease (n = 3; 30%), who had a median survival of 792 days. Six patients, all with unresectable disease, did not live beyond 30 days. Two of the three patients with resectable disease had subsequent curative resection. CONCLUSIONS: Transcatheter arterial embolization can be considered for cases of acute hemorrhagic gastric adenocarcinoma, with improved outcomes in patients with localized disease compared with nonresectable gastric adenocarcinoma.


Asunto(s)
Adenocarcinoma/complicaciones , Embolización Terapéutica/métodos , Hemorragia Gastrointestinal/terapia , Neoplasias Gástricas/complicaciones , Enfermedad Aguda , Adenocarcinoma/irrigación sanguínea , Adenocarcinoma/mortalidad , Adenocarcinoma/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Femenino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos , Neoplasias Gástricas/irrigación sanguínea , Neoplasias Gástricas/mortalidad , Neoplasias Gástricas/cirugía , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA