Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Bratisl Lek Listy ; 122(9): 636-642, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34463109

RESUMEN

PURPOSE: The geriatric nutritional risk index (GNRI) is a simple and objective nutritional assessment tool for elderly patients. Lower GNRI values are associated with a worse prognosis in heart failure with reduced ejection fraction (HFrEF). Our aim is to investigate the relationship between malnutrition and follow-up cardiovascular (CV) events in HFrEF. METHODS: A retrospective study was performed on 362 patients with HFrEF. The baseline GNRI was calculated at the first visit. The patients were divided into three groups according to the GNRI: >98, no-risk group; 92 to ≤98, low risk group; 82 to <92, moderate­to­high­risk group. The study endpoint was a composite of follow-upCV events, including all-cause mortality, non-valvular atrial fibrillation (NVAF) , need for cardioverter defibrillator (ICD) therapy, HfrEF­related hospitalizations and need for percutaneous coronary interventions (PCIs). RESULTS: Follow-up data showed that the group with moderate-to-high risk had a significantly higher incidence of NVAF, PCIs and all-cause mortality compared to other groups (p<0.001, p: 0.026 and p0.05). Mean GNRI value was 83.3 in NVAF patients and 101.1 in patients without NVAF (p<0.001). Kaplan Meier survival analysis showed that patients from the group with moderate-to-high risk had a significantly worse survival rate (p < 0.001). In the multivariate Cox regression analysis, the group with moderate-to­high risk (HR=3.872) and ICD implantations (HR=4.045) were associated with increased mortality. CONCLUSION: The GNRI value may have a potential role for predicting future events, especially NVAF in patients with HfrEF (Tab. 4, Fig. 2, Ref. 27).


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Evaluación Geriátrica , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Humanos , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico
2.
Med Phys ; 26(9): 1989-94, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10505889

RESUMEN

The depth distribution of the thermal neutron flux is a major factor in boron neutron capture therapy (BNCT) in determining the efficiency of cell sterilization. In this paper the fission detector method is developed and applied to measure the in-phantom thermal neutron flux depth distribution. Advantages of the fission detector include small size, direct measurement of thermal neutron flux in a mixed radiation field of BNCT beam, self-calibration, and the possibility of on-line measurement. The measurements were performed at epithermal a BNCT facility. The experimental results were compared with the thermal neutron flux calculated by the Monte Carlo method and found to be in good agreement.


Asunto(s)
Terapia por Captura de Neutrón de Boro/métodos , Radiometría/métodos , Fenómenos Biofísicos , Biofisica , Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Humanos , Método de Montecarlo , Neoplasias/radioterapia , Fantasmas de Imagen , Radiometría/instrumentación , Radiometría/estadística & datos numéricos , Semiconductores , Transistores Electrónicos , Uranio
3.
Med Phys ; 27(1): 239-44, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10659763

RESUMEN

Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires a dosimeter with a micron resolution. We investigated the use of a MOSFET dosimeter in an "edge-on" orientation with the gate insulating oxide layer parallel to the direction of the beam. We compared results using this technique to Gafchromic film measurements of a 200 micrometer wide planar x-ray microbeam. The microbeam was obtained by using a vernier micrometer-driven miniature collimator attached to a Therapax DXT300 x-ray machine operated at 100 kVp. The "edge-on" application allows utilization of the ultra thin sensitive volume of the MOSFET detector. Spatial resolution of both the MOSFET and Gafchromic film dosimeters appeared to be of about 1 micrometer. The MOSFET dosimeter appeared to provide more uniform dose profiles with the advantage of on-line measurements.


Asunto(s)
Monitoreo de Radiación/instrumentación , Fenómenos Biofísicos , Biofisica , Estudios de Evaluación como Asunto , Humanos , Fantasmas de Imagen , Monitoreo de Radiación/métodos , Monitoreo de Radiación/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador , Sincrotrones , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA