Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
World J Urol ; 42(1): 46, 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38244083

RESUMEN

PURPOSE: Urolithiasis has become increasingly prevalent, leading to higher disability-adjusted life years and deaths. Various stone classification systems have been developed to enhance the understanding of lithogenesis, aid urologists in treatment decisions, and predict recurrence risk. The aim of this manuscript is to provide an overview of different stone classification criteria. METHODS: Two authors conducted a review of literature on studies relating to the classification of urolithiasis. A narrative synthesis for analysis of the studies was used. RESULTS: Stones can be categorized based on anatomical position, size, medical imaging features, risk of recurrence, etiology, composition, and morphoconstitutional analysis. The first three mentioned offer a straightforward approach to stone classification, directly influencing treatment recommendations. With the routine use of CT imaging before treatment, precise details like anatomical location, stone dimensions, and Hounsfield Units can be easily determined, aiding treatment planning. In contrast, classifying stones based on risk of recurrence and etiology is more complex due to dependencies on multiple variables, including stone composition and morphology. A classification system based on morphoconstitutional analysis, which combines morphological stone appearance and chemical composition, has demonstrated its value. It allows for the rapid identification of crystalline phase principles, the detection of crystalline conversion processes, the determination of etiopathogenesis, the recognition of lithogenic processes, the assessment of crystal formation speed, related recurrence rates, and guidance for selecting appropriate treatment modalities. CONCLUSIONS: Recognizing that no single classification system can comprehensively cover all aspects, the integration of all classification approaches is essential for tailoring urolithiasis patient-specific management.


Asunto(s)
Litotricia , Urolitiasis , Humanos , Urolitiasis/terapia , Diagnóstico por Imagen , Litotricia/métodos , Urólogos
2.
World J Urol ; 42(1): 277, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38691160

RESUMEN

PURPOSE: To prospectively evaluate the rate and associated risk factors of early infectious complications after ureterorenoscopy for urolithiasis. METHODS: After ethical committee approval, 400 therapeutic retrograde ureterorenoscopy procedures between August 3, 2020 and November 24, 2021 were included for analysis in a single-center study. Postoperative infection was defined as an afebrile urinary tract infection, fever (≥ 38 °C) with pyuria (≥ 300 WBC/µL) or proven urinary pathogen, and urosepsis. The primary outcome was the rate of infectious complications after ureterorenoscopy. Secondary outcomes were the perioperative factors that increased the risk of infectious complications within 30 days of surgery using univariate and multivariate logistic regression analysis. RESULTS: Twenty-nine of four hundred (7.3%) patients developed an infectious complication within 30 days after ureterorenoscopy. Ten (2.5%) patients developed an afebrile urinary tract infection, eight (2.0%) developed fever with pyuria, five (1.3%) febrile urinary tract infection, and six (1.5%) urosepsis. On univariate analysis, preoperative stent-type JFil® pigtail suture stent was significantly associated with the dependent variable (p < 0.001). On multivariate logistic regression analysis, older age (OR 1.035; 95% CI 1.006-1.070; p = 0.02) was found to be significantly associated with developing a postoperative infectious complication. CONCLUSIONS: A 7.3% rate of postoperative infectious complications and 1.5% urosepsis rate were observed after therapeutic ureterorenoscopy, without the need of intensive care admission. The only significant risk factors were preoperative stent type (JFil® pigtail suture stent) on univariate analysis, and older age on multivariate logistic regression analysis. Further multicentric prospective observational data are needed in this field.


Asunto(s)
Complicaciones Posoperatorias , Ureteroscopía , Infecciones Urinarias , Humanos , Masculino , Femenino , Estudios Prospectivos , Factores de Riesgo , Ureteroscopía/efectos adversos , Persona de Mediana Edad , Infecciones Urinarias/epidemiología , Infecciones Urinarias/etiología , Adulto , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Factores de Tiempo , Sepsis/etiología , Sepsis/epidemiología , Urolitiasis/cirugía
3.
World J Urol ; 42(1): 487, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39158747

RESUMEN

OBJECTIVE: To evaluate the stone ablation rate and direct thermal damage from thulium fiber laser (TFL) lithotripsy using continuous (C) and burst (B) lasing techniques on an in vitro ureteral model. METHODS: The TFL Drive (Coloplast, Humlebaek, Denmark) was used in an in vitro saline-submerged ureteral model. Ten participants, including five junior and five experienced urologists, conducted the experimental setup with 7 different settings comparing two lasing techniques: steady-state lasing (0.5 J/10 Hz = 5W for 300 s and 0.5 J/20 Hz = 10W for 150 s) and burst, intermittent 5 s on/off lasing (0.5 J/20 Hz, 0.5 J/30 Hz, 0.5 J/60 Hz, 0.1 J/200 Hz, and 0.05 J/400 Hz) with a target cumulative energy of 1500 J using cubic 125 mm3 phantom BegoStonesTM. Ureteral damage was graded 1-3 based on the severity of burns and holes observed on the surface of the ureteral model. RESULTS: The were no significant differences in stone ablation mass neither between C and B lasing techniques, nor between expertise levels. At C lasing technique had only mild ureteral lesions with no significant differences between expertise levels (p: 0.97) or laser settings (p: 0.71). At B lasing technique, different types of thermal lesions were found with no expertise (p: 0.11) or setting (p: 0.83) differences. However, B laser setting had higher grade direct thermal lesions than C (p: 0.048). CONCLUSION: Regarding efficacy, C and B lasing techniques achieve comparable stone ablation rates. Safety-wise, B lasing mode showed higher grade of direct thermal lesions. These results should be further investigated to verify which of the lasing mode is the safest in vivo. Until then and unless proven otherwise, a C mode with low frequency should be recommended to avoid ureteral wall lesions.


Asunto(s)
Litotripsia por Láser , Tulio , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Humanos , Uréter/cirugía , Cálculos Ureterales/cirugía , Técnicas In Vitro , Láseres de Estado Sólido/uso terapéutico
4.
World J Urol ; 42(1): 310, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38722553

RESUMEN

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Urólogos , Humanos , Urología , Procedimientos Quirúrgicos Urológicos
5.
World J Urol ; 42(1): 298, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709327

RESUMEN

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Asunto(s)
Diseño de Equipo , Riñón , Iluminación , Ureteroscopios , Modelos Anatómicos , Humanos
6.
World J Urol ; 42(1): 355, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38796790

RESUMEN

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Asunto(s)
Diseño de Equipo , Iluminación , Ureteroscopios , Ureteroscopía , Luz , Humanos , Solución Salina , Color
7.
World J Urol ; 42(1): 294, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38704777

RESUMEN

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Asunto(s)
Ureteroscopios , Ureteroscopía , Humanos , Diseño de Equipo , Iluminación , Docilidad , Cálices Renales
8.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520528

RESUMEN

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Asunto(s)
Iluminación , Ureteroscopios , Humanos , Diseño de Equipo , Urólogos , Equipos Desechables , Ureteroscopía
9.
World J Urol ; 42(1): 453, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39073430

RESUMEN

PURPOSE: To examine temporal-spatial distribution of heat generated upon laser activation in a bench model of renal calyx. To establish reference values for a safety distance between the laser fiber and healthy tissue during laser lithotripsy. METHODS: We developed an in-vitro experimental setup employing a glass pipette and laser activation under various intra-operative parameters, such as power and presence of irrigation. A thermal camera was used to monitor both temporal and spatial temperature changes during uninterrupted 60-second laser activation. We computed the thermal dose according to Sapareto and Dewey's formula at different distances from the laser fiber tip, in order to determine a safety distance. RESULTS: A positive correlation was observed between average power and the highest recorded temperature (Spearman's coefficient 0.94, p < 0.001). Irrigation was found to reduce the highest recorded temperature, with a maximum average reduction of 9.4 °C at 40 W (p = 0.002). A positive correlation existed between average power and safety distance values (Spearman's coefficient 0.86, p = 0.001). A thermal dose indicative of tissue damage was observed at 20 W without irrigation (safety distance 0.93±0.11 mm). While at 40 W, irrigation led to slight reduction in mean safety distance (4.47±0.85 vs. 5.22±0.09 mm, p = 0.08). CONCLUSIONS: Laser settings with an average power greater than 10 W deliver a thermal dose indicative of tissue damage, which increases with higher average power values. According to safety distance values from this study, a maximum of 10 W should be used in the ureter, and a maximum of 20 W should be used in kidney in presence of irrigation.


Asunto(s)
Litotripsia por Láser , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Humanos , Calor , Cálices Renales , Irrigación Terapéutica/métodos
10.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38488927

RESUMEN

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Protección Radiológica , Humanos , Estudios Prospectivos , Exposición Profesional/prevención & control , Fluoroscopía/efectos adversos , Exposición a la Radiación/prevención & control , Dosis de Radiación
11.
World J Urol ; 42(1): 33, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38217743

RESUMEN

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Asunto(s)
Aluminio , Láseres de Estado Sólido , Litotripsia por Láser , Urolitiasis , Itrio , Humanos , Tulio , Urolitiasis/cirugía , Litotripsia por Láser/métodos , Láseres de Estado Sólido/uso terapéutico , Tecnología , Holmio
12.
BMC Urol ; 24(1): 24, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38287319

RESUMEN

INTRODUCTION: Extended pelvic lymph node dissection (ePLND) in men undergoing robot-assisted laparoscopic radical prostatectomy (RARP) is a widely used procedure. However, little is known about anatomical site-specific yields and subsequent metastatic patterns in these patients. PATIENTS AND METHODS: Data on a consecutive series of 1107 patients undergoing RARP at our centre between 2004 and 2018 were analysed. In men undergoing LN dissection, the internal, external and obturator nodes were removed and sent in separately. We performed an analysis of LN yields in total and for each anatomical zone, patterns of LN metastases and complications. Oncological outcome in pN+ disease was assessed including postoperative PSA persistence and survival. RESULTS: A total of 823 ePLNDs were performed in the investigated cohort resulting in 98 men being diagnosed as pN+ (8.9%). The median (IQR) LN yield was 19 (14-25), 10 (7-13) on the right and 9 (6-12) on the left side (P < 0.001). A median of six (4-8) LNs were retrieved from the external, three (1-6) from the internal iliac artery, and eight (6-12) from the obturator fossa. More men had metastatic LNs on the right side compared to the left (41 vs. 19). Symptomatic lymphoceles occurred exclusively in the ePLND group (2.3% vs. 0%, p = 0.04). Postoperatively, 47 (47.9%) of men with pN+ reached a PSA of < 0.1µg/ml. There was no association between a certain pN+ region and postoperative PSA persistence or BCRFS. The estimated cancer specific survival rate at 5 years was 98.5% for pN+ disease. CONCLUSION: Robot-assisted laparoscopic ePLND with a high LN yield and low complication rate is feasible. However, we observed an imbalance in more removed and positive LNs on the right side compared to the left. A high rate of postoperative PSA persistence and early recurrence in pN+ patients might indicate a possibly limited therapeutical value of the procedure in already spread disease. Yet, these men demonstrated an excellent survival.


Asunto(s)
Laparoscopía , Neoplasias de la Próstata , Robótica , Masculino , Humanos , Antígeno Prostático Específico , Metástasis Linfática , Escisión del Ganglio Linfático/métodos , Neoplasias de la Próstata/patología , Ganglios Linfáticos/patología , Pelvis/patología , Prostatectomía/métodos , Laparoscopía/métodos
13.
Turk J Med Sci ; 54(1): 185-193, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38812627

RESUMEN

Background/aim: Management of asymptomatic kidney stones is an ongoing debate with follow-up and treatment guidelines based on low-level evidence. Our aim was to evaluate current management of asymptomatic urinary stones. Materials and methods: A 70-question survey was designed in collaboration with European Association of Urology, Young Academic Urologists, Section of Uro-Technology and Section of Urolithiasis groups and distributed. Responders filled out hypothetical scenarios from 2 perspectives, either as treating physicians, or as patients themselves. Results: A total of 212 (40.01%) responses were obtained. Median responder age was 39 years. 75% of responders were interested in "urolithiasis". 82.5% had never experienced a renal colic, 89.6% had never undergone urolithiasis treatment.Overall, as the kidney stone scenarios got more complicated, the invasiveness of the treatment preference increased. As "the physician", responders preferred the conservative option in all situations more than they would choose as "the patient". For ureteral stones, conservative approach was most preferred for small stones and ureteroscopy became more preferred as the stone size increased.For smaller kidney stones, the most preferred follow-up schedule was 4-6 monthly, whereas for larger and complicated stones it was 0-3 monthly from both perspectives respectively. For all ureteral stone scenarios, 0-4 weekly follow-up was mostly preferred.Interestingly, having had a renal colic was an independent predictor of an interventional approach, whereas having had an intervention was an independent predictor of a conservative approach. Conclusion: Current treatment and follow-up patterns of asymptomatic urinary stones are in agreement with international guidelines on symptomatic stones.In most of the urolithiasis situations urologists chose a conservative approach for their patients compared to what they would prefer for themselves. Conversely, urologists, in the scenarios as "the patient", would like to have a more frequent follow-up schedule for their stones compared to how they would follow-up their patients.


Asunto(s)
Urólogos , Humanos , Adulto , Encuestas y Cuestionarios , Masculino , Femenino , Urología , Cálculos Renales/terapia , Ureteroscopía , Pautas de la Práctica en Medicina/estadística & datos numéricos , Urolitiasis/terapia , Persona de Mediana Edad , Europa (Continente) , Actitud del Personal de Salud , Enfermedades Asintomáticas/terapia
14.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37831156

RESUMEN

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Litotricia , Nefrolitiasis , Cálculos Urinarios , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Litotripsia por Láser/métodos , Cálculos Urinarios/terapia , Oxalato de Calcio , Holmio
15.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37587366

RESUMEN

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Cálculos Urinarios , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Polvo , Litotripsia por Láser/métodos , Cálculos Urinarios/terapia
16.
World J Urol ; 41(11): 3301-3308, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37682286

RESUMEN

INTRODUCTION: Several preclinical studies about a novel pulsed-thulium:yttrium-aluminum-garnet (p-Tm:YAG) device have been published, demonstrating its possible clinical relevance. METHODS: We systematically reviewed the reality and expectations for this new p-Tm:YAG technology. A PubMed, Scopus and Embase search were performed. All relevant studies and data identified in the bibliographic search were selected, categorized, and summarized. RESULTS: Tm:YAG is a solid state diode-pumped laser that emits at a wavelength of 2013 nm, in the infrared spectrum. Despite being close to the Ho:YAG emission wavelength (2120 nm), Tm:YAG is much closer to the water absorption peak and has higher absorption coefficient in liquid water. At present, there very few evaluations of the commercially available p-Tm:YAG devices. There is a lack of information on how the technical aspects, functionality and pulse mechanism can be maximized for clinical utility. Available preclinical studies suggest that p-Tm:YAG laser may potentially increase the ablated stone weight as compared to Ho:YAG under specific condition and similar laser parameters, showing lower retropulsion as well. Regarding laser safety, a preclinical study observed similar absolute temperature and cumulative equivalent minutes at 43° C as compared to Ho:YAG. Finally, laser-associated soft-tissue damage was assessed at histological level, showing similar extent of alterations due to coagulation and necrosis when compared with the other clinically relevant lasers. CONCLUSIONS: The p-Tm:YAG appears to be a potential alternative to the Ho:YAG and TFL according to these preliminary laboratory data. Due to its novelty, further studies are needed to broaden our understanding of its functioning and clinical applicability.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Temperatura , Agua , Holmio
17.
Eur Radiol ; 33(9): 6238-6244, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36988716

RESUMEN

OBJECTIVES: To assess the accuracy of low-dose dual-energy computed tomography (DECT) to differentiate uric acid from non-uric acid kidney stones in two generations of dual-source DECT with stone composition analysis as the reference standard. METHODS: Patients who received a low-dose unenhanced DECT for the detection or follow-up of urolithiasis and stone extraction with stone composition analysis between January 2020 and January 2022 were retrospectively included. Collected stones were characterized using X-ray diffraction. Size, volume, CT attenuation, and stone characterization were assessed using DECT post-processing software. Characterization as uric acid or non-uric acid stones was compared to stone composition analysis as the reference standard. Sensitivity, specificity, and accuracy of stone classification were computed. Dose length product (DLP) and effective dose served as radiation dose estimates. RESULTS: A total of 227 stones in 203 patients were analyzed. Stone composition analysis identified 15 uric acid and 212 non-uric acid stones. Mean size and volume were 4.7 mm × 2.8 mm and 114 mm3, respectively. CT attenuation of uric acid stones was significantly lower as compared to non-uric acid stones (p < 0.001). Two hundred twenty-five of 227 kidney stones were correctly classified by DECT. Pooled sensitivity, specificity, and accuracy were 1.0 (95%CI: 0.97, 1.00), 0.93 (95%CI: 0.68, 1.00), and 0.99 (95%CI: 0.97, 1.00), respectively. Eighty-two of 84 stones with a diameter of ≤ 3 mm were correctly classified. Mean DLP was 162 ± 57 mGy*cm and effective dose was 2.43 ± 0.86 mSv. CONCLUSIONS: Low-dose dual-source DECT demonstrated high accuracy to discriminate uric acid from non-uric acid stones even at small stone sizes. KEY POINTS: • Two hundred twenty-five of 227 stones were correctly classified as uric acid vs. non-uric acid stones by low-dose dual-energy CT with stone composition analysis as the reference standard. • Pooled sensitivity, specificity, and accuracy for stone characterization were 1.0, 0.93, and 0.99, respectively. • Low-dose dual-energy CT for stone characterization was feasible in the majority of small stones < 3 mm.


Asunto(s)
Cálculos Renales , Cálculos Urinarios , Humanos , Estudios Retrospectivos , Cálculos Renales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Ácido Úrico/análisis , Dosis de Radiación
18.
Curr Opin Urol ; 32(3): 330-338, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35256579

RESUMEN

PURPOSE OF REVIEW: This review provides most recent findings and developments relating to surgical laser fibers, strippers, cleavers, and protective glasses. RECENT FINDINGS: The smallest core diameter that can be used with Holmium:YAG lasers is 200 µm. Smaller core diameter fibers can be used with the Thulium fiber laser and offer better flexibility and lower risk of fracture, at the risk of greater burnback effect. Misleading discrepancies between the true diameter of laser fibers and their packaging labels must be considered. Fiber tip degradation from the burnback occurs within few minutes, thus questioning the need for time-consuming fiber tip reprocessing with fiber strippers and special cleaving tools. This shortcoming also applies to instrument-protecting ball-tip fibers. Cleavage of fiber tips through their protective jackets ('coated tips') is a cheaper alternative for instrument protection, additionally offering better visual control of the fiber tip. Third-generation side-firing greenlight laser fibers are still prone to rapid deterioration. Laser eyewear does not seem necessary for Holmium:YAG applications, whereas laser-specific protective glasses should be worn for greenlight laser applications. SUMMARY: With better understanding of laser accessories, practicing urologists may tailor their practice to reach optimal efficacy and safety for Holmium:YAG, Thulium fiber laser and Greenlight laser applications.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Litotripsia por Láser , Holmio , Humanos , Terapia por Láser/efectos adversos , Láseres de Estado Sólido/uso terapéutico , Tulio
19.
World J Urol ; 39(1): 187-194, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32270283

RESUMEN

PURPOSE: To propose a size-related definition of stone dust produced by lithotripsy of urinary stones. METHODS: Stone dust was defined as particles small enough to adhere to the following criteria: (1) spontaneous floating under 40 cm H2O irrigation pressure; (2) mean sedimentation time of > 2 s through 10 cm saline solution; (3) fully suitable for aspiration through a 3.6 F working channel. Irrigation, sedimentation, and aspiration tests were set up to evaluate each criterion. Primary outcome was particle size limit agreeing with all three criteria. Stone particles with a given size limit (≤ 2 mm, ≤ 1 mm, ≤ 500 µm, ≤ 250 µm, ≤ 125 µm and ≤ 63 µm) were obtained from laser lithotripsy, including samples from prevailing stone types: calcium oxalate monohydrate, calcium oxalate dihydrate, uric acid, carbapatite, struvite, brushite, and cystine. RESULTS: All particles ≤ 250 µm from all stone types were in agreement with all three criteria defining stone dust, except for struvite where size limit for a positive irrigation and sedimentation test was ≤ 125 µm. CONCLUSION: A size limit of ≤ 250 µm seems to generally adhere to our definition of stone dust, which is based on floating and sedimentation proprieties of stone particles, as well as on the ability to be fully aspirated through the working channel of a flexible ureteroscope.


Asunto(s)
Polvo , Litotripsia por Láser , Tamaño de la Partícula , Cálculos Urinarios/química , Humanos , Técnicas In Vitro , Cálculos Urinarios/terapia
20.
World J Urol ; 39(6): 1693-1698, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32363450

RESUMEN

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the thulium fiber laser (TFL) for lithotripsy. Where applicable, stone dust was further characterized by morpho-constitutional analysis. METHODS: Human urinary stones were submitted to in vitro lithotripsy using a FiberLase U2 TFL generator with 150 µm silica core fibers (IPG Photonics®, IPG Medical™, Marlborough, MA, USA). Laser settings were 0.05 J, 320 Hz and 200 µs. A total of 2400 J were delivered to each stone composition type. All evaluated stones had a > 90% degree of purity (calcium oxalate monohydrate, calcium oxalate dihydrate, uric acid, carbapatite, struvite, brushite and cystine). Spontaneously floating stone particles were considered as stone dust and collected for analysis by scanning electron microscopy and Fourier transform infrared spectroscopy. RESULTS: Stone dust could be retrieved from all evaluated urinary stones after TFL lithotripsy. Most stone dust samples revealed changes in crystalline organization, except for calcium oxalate monohydrate and carbapatite, which conserved their initial characteristics. Mean maximal width of stone dust particles did not exceed 254 µm. CONCLUSIONS: The TFL is capable to produce stone dust from all prevailing stone types. Morpho-constitutional changes found in stone dust suggest a photothermal interaction of laser energy with the stone matrix during TFL lithotripsy.


Asunto(s)
Litotripsia por Láser , Tulio/uso terapéutico , Cálculos Urinarios/química , Cálculos Urinarios/terapia , Polvo , Humanos , Técnicas In Vitro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA