Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
1.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 103(2): 367-375, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37890014

RESUMEN

AIMS: Characterize the impact of residual tricuspid regurgitation (TR) on right ventricle (RV) remodeling and clinical outcomes after transcatheter tricuspid valve intervention. METHODS: We performed a single-center retrospective analysis of transcatheter tricuspid valve repair (TTVr) or replacement (TTVR) patients. The primary outcomes were longitudinal tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), pulmonary artery systolic pressure (PASP), and RV dimensions (RVd). We used multivariable linear mixed models to evaluate association with replacement versus repair and degree of TR reduction with changes in these echo measures over time. Multivariable Cox regression was used to identify associations between changes in these echo measures and a composite clinical outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention. RESULTS: We included a total of 61 patients; mean age was 77.5 ± 11.7 and 62% were female. TTVR was performed in 25 (41%) and TTVr in 36 (59%). Initially, 72% (n = 44) had ≤ severe TR and 28% (n = 17) had massive or torrential TR. The median number of follow up echos was 2: time to 1st follow-up was 50 days (interquartile range [IQR]: 20, 91) and last follow-up was 147 (IQR: 90, 327). Median TR reduction was 1 (IQR: 0, 2) versus 4 (IQR: 3, 6) grades in TTVr versus TTVR (p < 0.0001). In linear mixed modeling, TTVR was associated with decline in TAPSE and PASP, and TR reduction was associated with decreased RVd. In multivariable Cox regression, greater RVd was associated with the clinical outcome (hazard ratio: 9.27, 95% confidence interval: 1.23-69.88, p = 0.03). CONCLUSION: Greater TR reduction is achieved by TTVR versus TTVr, which is in turn associated with RV reverse remodeling. RV dimension in follow-up is associated with increased risk of a composite outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Estudios Retrospectivos , Remodelación Ventricular , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia
3.
Catheter Cardiovasc Interv ; 103(6): 833-842, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639137

RESUMEN

BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Intervención Coronaria Percutánea , Stents , Tomografía de Coherencia Óptica , Calcificación Vascular , Humanos , Masculino , Femenino , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Anciano , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Prevalencia , Factores de Riesgo , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Diseño de Prótesis , Valor Predictivo de las Pruebas , Factores de Tiempo , Angiografía Coronaria , Remodelación Vascular
4.
Curr Cardiol Rep ; 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38809401

RESUMEN

PURPOSE OF REVIEW: To provide a summary of prevalence, pathogenesis, and treatment of coronary calcified nodules (CNs). RECENT FINDINGS: CNs are most frequently detected at the sites of hinge motion of severely calcified lesions such as in the middle segment of right coronary artery and left main coronary bifurcation. On histopathology, CNs exhibit two distinctive morphologies: eruptive and non-eruptive. Eruptive CNs, which have a disrupted fibrous cap with adherent thrombi, are biologically active. Non-eruptive CNs, which have an intact fibrous cap without thrombi, are biologically inactive, representing either healed eruptive CNs or protrusion of calcium due to plaque progression. Recent studies using optical coherence tomography (OCT) have shown a difference in the mechanism of stent failure in the two subtypes, demonstrating early reappearance of eruptive CNs in the stent (at ~ 6 months) as a unique mechanism of stent failure that does not seem to be preventable by simply achieving adequate stent expansion. The cause of CN reappearance in stent is not known and could be due to acute or subacute intrusion or continued growth of the CN. Whether modification of CN is needed, the most effective calcium modification modality and effectiveness of stent implantation in eruptive CNs has not been elucidated. In this review, we discuss pathogenesis of CNs and how intravascular imaging can help diagnose and manage patients with CNs. We also discuss medical and transcatheter therapies beyond conventional stent implantation for effective treatment of eruptive CNs that warrant testing in prospective studies.

5.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37793121

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
6.
Echocardiography ; 40(2): 137-142, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36647761

RESUMEN

In this case report, we illustrate the contemporary use of multi-modality cardiac imaging and three-dimensional (3D)-printing in the diagnosis and precise surgical planning of a large ventricular aneurysm with an extensive thrombus burden after myocardial infarction. We further discuss an integrated multimodality approach in the evaluation of ventricular outpouchings.


Asunto(s)
Aneurisma Falso , Aneurisma Cardíaco , Infarto del Miocardio , Humanos , Aneurisma Falso/diagnóstico por imagen , Aneurisma Cardíaco/diagnóstico por imagen , Aneurisma Cardíaco/etiología , Infarto del Miocardio/complicaciones , Imagen Multimodal , Impresión Tridimensional
7.
Catheter Cardiovasc Interv ; 99(5): 1668-1678, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35066989

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the incidence of and risk factors associated with cardiogenic shock (CS) following surgery versus transcatheter tricuspid valve intervention (TTVI) for tricuspid regurgitation (TR). BACKGROUND: Surgical therapy for TR is associated with high rates of CS. Postprocedural shock has not been studied following TTVI. METHODS: We performed a single-center retrospective analysis of isolated tricuspid valve (TV) surgery or TTVI for TR. The primary outcome was postprocedural class D or E CS according to Society for Cardiovascular Angiography and Interventions (SCAI) CS classification scheme, and secondary outcome was in-hospital mortality. Multivariable logistic regression modeling was performed for primary and secondary outcomes. Support vector machine analysis was performed for sensitivity analysis. RESULTS: From 2008 to 2020, a total of 122 patients underwent isolated TV surgery (n = 58, 14 TV repair, and 44 TV replacement) or TTVI (n = 64, 36 TV repair, and 28 TV replacement). Surgical patients were significantly younger than TTVI patients (67.5 vs. 80 years, p < 0.0001). Multivariable modeling revealed an association between the primary outcome and surgery (odds ratio [OR]: 8.75, 95% confidence interval [CI]: 2.83, 27.03, p = 0.0002), as well as baseline central venous pressure (CVP, OR: 1.12, 95% CI: 1.02, 1.22, p = 0.016). Additionally, class DE CS was independently associated with in-hospital mortality (OR: 5.21, 1.35, 20.09, p = 0.016). CVP and surgery were found to have highest importance indices in support vector machine analysis. CONCLUSION: In patients undergoing TV intervention for TR, surgery versus TTVI and elevated CVP are associated with advanced postprocedural CS. Patients developing advanced CS are at increased risk of in-hospital mortality.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Incidencia , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/epidemiología , Choque Cardiogénico/terapia , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/cirugía
8.
Catheter Cardiovasc Interv ; 100 Suppl 1: S44-S56, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36251325

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) is an adjunct to angiography-guided coronary stent placement. However, in the absence of dedicated, appropriately powered randomized controlled trials, the impact of OCT on clinical outcomes is unclear. OBJECTIVE: To conduct a systematic review and meta-analysis of all available studies comparing OCT-guided versus angiography-guided and intravascular ultrasound (IVUS)-guided coronary stent implantation. METHODS: MEDLINE and Cochrane Central were queried from their inception through July 2022 for all studies that sought to compare OCT-guided percutaneous coronary intervention (PCI) to angiography-guided and IVUS-guided PCI. The primary endpoint was minimal stent area (MSA) compared between modalities. Clinical endpoints of interest were all-cause and cardiovascular mortality, major adverse cardiovascular events (MACE), myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis (ST). Risk ratios (RRs) and mean differences (MDs) with their corresponding 95% confidence intervals (CIs) were pooled using a random-effects model. RESULTS: Thirteen studies (8 randomized control trials and 5 observational studies) enrolling 6312 participants were included. OCT was associated with a strong trend toward increased MSA compared to angiography (MD = 0.36, p = 0.06). OCT-guided PCI was also associated with a reduction in the incidence of all-cause mortality [RR = 0.59, 95% CI (0.35, 0.97), p = 0.04] and cardiovascular mortality [RR = 0.41, 95% CI (0.21, 0.80), p = 0.009] compared with angiography-guided PCI. Point estimates favored OCT relative to angiography in MACE [RR = 0.75, 95% CI (0.47, 1.20), p = 0.22] and MI [RR = 0.75, 95% CI (0.53, 1.07), p = 0.12]. No differences were detected in ST [RR = 0.71, 95% CI (0.21, 2.44), p = 0.58], TLR [RR = 0.71, 95% CI (0.17, 3.05), p = 0.65], or TVR rates [RR = 0.89, 95% CI (0.46, 1.73), p = 0.73]. Compared with IVUS guidance, OCT guidance was associated with a nonsignificant reduction in the MSA (MD = -0.16, p = 0.27). The rates of all-cause and cardiovascular mortality, MACE, MI, TLR, TVR, or ST were similar between OCT-guided and IVUS-guided PCI. CONCLUSIONS: OCT-guided PCI was associated with reduced all-cause and cardiovascular mortality compared to angiography-guided PCI. These results should be considered hypothesis generating as the mechanisms for the improved outcomes were unclear as no differences were detected in the rates of TLR, TVR, or ST. OCT- and IVUS-guided PCI resulted in similar post-PCI outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Angiografía Coronaria/efectos adversos , Tomografía de Coherencia Óptica/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Ultrasonografía Intervencional/métodos , Resultado del Tratamiento , Stents/efectos adversos , Infarto del Miocardio/etiología , Trombosis/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
Catheter Cardiovasc Interv ; 99(4): 1268-1276, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35084803

RESUMEN

OBJECTIVES: The purpose of this study was to characterize the anatomic relationship between the inferior vena cava (IVC) and tricuspid annulus (TA) and its potential impact on the performance of transcatheter TV interventions. BACKGROUND: Transcatheter tricuspid valve (TV) interventions are emerging as a therapeutic alternative for the treatment of severe, symptomatic tricuspid regurgitation (TR). Progression of TR is associated with right heart dilatation. These anatomic changes may distort the IVC-TA relationship and impact successful implantation of transcatheter devices. METHODS: Fifty patients who presented with symptomatic TR for consideration of transcatheter TV therapy with an available CT were included in the study. Comprehensive transesophageal echocardiogram and CT analyses were performed to assess the right-sided cardiac chambers, TA and IVC-TA relationship. RESULTS: The mean age of the study cohort was 78.4 ± 8.9 years. Torrential TR was present in 54% (n = 27). There was considerable variation in the short axis mid-IVC to mid-TA offset (SAXMID 18.2 ± 7.9 mm, range 4.7-42.1 mm). CONCLUSIONS: The IVC-to-TA relationship exhibits significant variability in patients with symptomatic TR. CT analysis of the tricuspid anatomy, including the relationship to the surrounding structures and the IVC, is essential for planning transcatheter TV interventions. Further studies are needed to define whether the IVC-to-TA relationship is a predictor of technical success in the context of specific transcatheter delivery systems.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Vena Cava Inferior/diagnóstico por imagen
10.
J Cardiovasc Magn Reson ; 24(1): 38, 2022 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-35725565

RESUMEN

The 25th Society for Cardiovascular Magnetic Resonance (SCMR) Annual Scientific Sessions saw 1524 registered participants from more than 50 countries attending the meeting virtually. Supporting the theme "CMR: Improving Cardiovascular Care Around the World", the meeting included 179 invited talks, 52 sessions including 3 plenary sessions, 2 keynote talks, and a total of 93 cases and 416 posters. The sessions were designed so as to showcase the multifaceted role of cardiovascular magnetic resonance (CMR) in identifying and prognosticating various myocardial pathologies. Additionally, various social networking sessions as well as fun activities were organized. The major areas of focus for the future are likely to be rapid efficient and high value CMR exams, automated and quantitative acquisition and post-processing using artificial intelligence and machine learning, multi-contrast imaging and advanced vascular imaging including 4D flow.


Asunto(s)
Inteligencia Artificial , Sistema Cardiovascular , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas
11.
Rev Cardiovasc Med ; 22(4): 1513-1521, 2021 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-34957790

RESUMEN

Transthoracic echocardiography (TTE) and Cardiac Magnetic Resonance (CMR) have complementary roles in the severity grading of mitral regurgitation (MR). Our objective was to systematically review the correlation of MR severity as assessed by TTE and CMR. We searched MEDLINE and Cochrane Library for original series published between January 1st, 2000 and March 23rd, 2020. We used Cohen's kappa coefficient to measure agreement between modalities. We plotted a hierarchical summary receiver operator characteristic (HSROC) curve and estimated the area under the curve (AUC) to assess the concordance between the two imaging modalities for the detection of severe MR. We identified 858 studies, of which 65 underwent full-text assessment and 8 were included in the meta-analysis. A total of 718 patients were included (425 males, 59%) in the final analysis. There was significant heterogeneity in the methods used and considerable variation in kappa coefficient, ranging from 0.10 to 0.48. Seven out of eight studies provided the necessary data to plot HSROC curves and calculate the AUC. The AUC for detecting severe MR was 0.83 (95% CI 0.80 to 0.86), whereas the AUC for detecting moderate to severe MR was 0.83 (95% CI 0.79 to 0.86). The agreement between TTE and CMR in MR severity evaluation is modest across the entire spectrum of severity grading. However, when focusing on patients with at least moderate MR the concordance between TTE and CMR is very good. Further prospective studies comparing hard clinical endpoints based on the CMR and TTE assessment of MR severity are needed.


Asunto(s)
Insuficiencia de la Válvula Mitral , Ecocardiografía/métodos , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
12.
J Card Surg ; 36(7): 2410-2418, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33797788

RESUMEN

BACKGROUND AND AIM OF THE STUDY: A systematic approach to quantify mitral annular calcification (MAC) in all-comers by multidetector computed tomography (MDCT) is essential to guide treatment, but lacking. METHODS: From September 2015 to July 2019, 82 patients with MAC underwent MDCT at two institutions to evaluate for surgical mitral valve replacement (SMVR), transcatheter mitral valve replacement (TMVR), or medical management. Type 1 MAC was defined as <270° annular calcium and Type 2 as ≥270°. Absence/presence of predicted left ventricular outflow tract (LVOT) obstruction with virtual valve placement was used to further define Type 2 MAC into 2A/B for our treatment algorithm. RESULTS: Type 1 MAC was present in 51.2%, Type 2A in 18.3%, and Type 2B in 30.5%. Operable Type 1 patients (50.0%) underwent hybrid transatrial TMVR or SMVR. Type 2A underwent a variety of treatments, and Type 2B surgical candidates (40.0%) underwent hybrid transatrial TMVR secondary to difficult suture anchoring with significant MAC and predicted LVOT obstruction. At a follow-up of 29.6 ± 12.0 months, mortality was 42.7% with 46.3% in the intervention group and 39.0% in the medical group (p = 0.47). All percutaneous TMVR patients expired. This translated to a disproportionate number of Type 2A deaths (80.0% with intervention), but all were high/extreme surgical risk. The hybrid TMVR group consisted of 95.0% Type 1/2B patients and had a lower Society of Thoracic Surgeons predicted risk of operative mortality (7.4% vs. 9.2%, p = 0.43)/mortality. CONCLUSIONS: The highest mortality was seen in percutaneous TMVR Type 2A MAC patients, but they were at the greatest risk. Here we provide an objective MAC treatment algorithm for all-comers based on operability/anatomy.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Obstrucción del Flujo Ventricular Externo , Cateterismo Cardíaco , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 95(6): 1178-1183, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31452322

RESUMEN

OBJECTIVES: To describe outcomes after suprasternal (SS) transcatheter aortic valve replacement (TAVR) as a new alternative access approach. BACKGROUND: There still remains a cohort of the TAVR population who are not suitable for a transfemoral (TF) approach. SS-TAVR is a safe and effective alternative to TF-TAVR and has now become our preferred alternative access route. METHODS: We retrospectively reviewed all patients from New York Presbyterian Hospital, Columbia University Medical Center and Princeton Baptist Medical Center who underwent SS-TAVR from 2015 to July 2018. A total of 84 patients were included in the study. RESULTS: Technical success was achieved in all cases. Thirty-day survival was 98.8% (n = 83). There were minimal complications. Most notably, there were no transient ischemic attacks or strokes (0%, n = 0). Reexploration for bleeding was 3.6% (n = 3), and major bleeding was 1.7% (n = 1). We also achieved satisfactory results with a mean aortic valve gradient of 6.07 ± 3.79 mmHg and an aortic valve area of 2.21 ± 0.51 cm2 . No patients had anything more than mild paravalvular leak. The mean length of stay (LOS) in the intensive care unit was 1.42 ± 1.23 days, and hospital LOS was 4.20 ± 3.29 days. CONCLUSIONS: SS access for TAVR is an extremely important technique to have in any valve team's alternative access armamentarium. This technique can be safely and reliably reproduced with any standard hybrid operating room setup and no additional equipment, and it can be used with any commercially available valve system. In the current experience, minimal complications and excellent early term results were obtained.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Alabama , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Ciudad de Nueva York , Complicaciones Posoperatorias/etiología , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
14.
J Cardiovasc Electrophysiol ; 30(4): 461-467, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30585678

RESUMEN

INTRODUCTION: Percutaneous left atrial appendage closure (LAAC) is typically performed utilizing transesophageal echocardiography (TEE) and fluoroscopy. Intracardiac echocardiography (ICE) can be a suitable alternative to guide implantation. Given the limited data, we performed a meta-analysis of all studies that compared ICE vs TEE for percutaneous LAAC. METHODS: A comprehensive literature search was performed in PubMed, Embase, Scopus, Google Scholar, and major scientific conference sessions for published abstracts and manuscripts until 1 August 2018. Studies reporting clinical outcomes comparing TEE vs ICE for endocardial LAAC in human subjects aged greater than or equal to 18 years were included. Two investigators independently extracted the data and individual quality assessment was performed. The analysis was performed using Cochrane Collaboration software, RevMan 5.3. RESULTS: Five eligible studies consisting of 1157 patients (ICE-391 patients and TEE-766 patients) were included. Four studies were retrospective and one was prospective, nonrandomized. Two studies included Watchman, two included the Amplatzer Cardiac Plug/Amulet device, and one included both devices. There was no significant difference in CHA2DS2VASC or HAS-BLED scores between both groups. There was no significant difference in acute procedural success between ICE vs TEE (risk ratio, 1.01; 95% CI, 0.99-1.04; P = 0.24). There was no significant difference in fluoroscopy time (mean difference [MD], 1.84 minutes; 95% CI, 0.59-4.27; P = 0.14) and total procedure time (MD, -5.06 minutes; 95% CI, -24.6-14.4; P = 0.61) between both groups. There was also no significant difference in complications including pericardial tamponade, device embolization, and stroke between both groups. CONCLUSION: In our meta-analysis, ICE was as effective as TEE during percutaneous LAAC.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Anciano , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 93(5): 996-1001, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30408318

RESUMEN

Transcatheter aortic valve replacement (TAVR) is not currently approved for pure native valve aortic incompetence, and is typically performed on a compassionate basis in selected patients who are at high risk for conventional surgery. We describe the first use of TAVR to treat iatrogenic severe acute pure aortic incompetence following mitral valve surgery. A 71-year-old gentleman developed life-threatening acute aortic regurgitation (AR) within hours of a very challenging fifth open heart mitral valve replacement. Careful inspection of echocardiographic and computed tomographic imaging identified the cause as a disrupted left coronary cusp at the commissure caused by the surgical mitral annular reconstruction. Medical management with afterload reduction failed with recurrent pulmonary edema, and a sixth open heart surgery was deemed prohibitively high risk. The lack of aortic annular calcium onto which anchors a transcatheter valve was a concern for TAVR. However, we postulated that the struts of the mitral valve bioprosthesis would offer some support to the TAVR valve. We opted for a self-expanding system because of concerns about potential unfavorable interaction between the balloon onto which balloon-expandable bioprosthesis is mounted and the struts of the mitral bioprosthesis, and because the Evolut R system has additional anchoring points at the crown which might enhance transcatheter valve stability in the non-calcified annulus, compared with the Edwards Sapien system. Transfemoral TAVR, performed with a Medtronic Evolut R 34 mm system under general anesthesia and using moderately rapid ventricular pacing, was successful with minimal residual AR. On follow-up 1 month later the patient was asymptomatic, and the aortic and mitral bioprostheses were functioning normally on echocardiogram.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Bioprótesis , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 93(6): 1152-1160, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30790417

RESUMEN

OBJECTIVES: To assess impact of left ventricular (LV) chamber remodeling on MitraClip (MClp) response. BACKGROUND: MitraClip is the sole percutaneous therapy approved for mitral regurgitation (MR) but response varies. LV dilation affects mitral coaptation; determinants of MClp response are uncertain. METHODS: LV and mitral geometry were quantified on pre- and post-procedure two-dimensional (2D) transthoracic echocardiography (TTE) and intra-procedural three-dimensional (3D) transesophageal echocardiography (TEE). Optimal MClp response was defined as ≤mild MR at early (1-6 month) follow-up. RESULTS: Sixty-seven degenerative MR patients underwent MClp: Whereas MR decreased ≥1 grade in 94%, 39% of patients had optimal response (≤mild MR). Responders had smaller pre-procedural LV end-diastolic volume (94 ± 24 vs. 109 ± 25 mL/m2 , p = 0.02), paralleling smaller annular diameter (3.1 ± 0.4 vs. 3.5 ± 0.5 cm, p = 0.002), and inter-papillary distance (2.2 ± 0.7 vs. 2.5 ± 0.6 cm, p = 0.04). 3D TEE-derived annular area correlated with 2D TTE (r = 0.59, p < 0.001) and was smaller among optimal responders (12.8 ± 2.1 cm2 vs. 16.8 ± 4.4 cm2 , p = 0.001). Both 2D and 3D mitral annular size yielded good diagnostic performance for optimal MClp response (AUC 0.73-0.84, p < 0.01). In multivariate analysis, sub-optimal MClp response was associated with LV end-diastolic diameter (OR 3.10 per-cm [1.26-7.62], p = 0.01) independent of LA size (1.10 per-cm2 [1.02-1.19], p = 0.01); substitution of mitral annular diameter for LV size yielded an independent association with MClp response (4.06 per-cm2 [1.03-15.96], p = 0.045). CONCLUSIONS: Among degenerative MR patients undergoing MClp, LV and mitral annular dilation augment risk for residual or recurrent MR, supporting the concept that MClp therapeutic response is linked to sub-valvular remodeling.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Ecocardiografía Doppler en Color , Ecocardiografía Doppler de Pulso , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ventrículos Cardíacos/fisiopatología , Hemodinámica , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
Cardiovasc Ultrasound ; 17(1): 31, 2019 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-31878931

RESUMEN

BACKGROUND: Echocardiography (echo) is widely used to guide therapeutic decision-making for patients being considered for MitraClip. Relative utility of two- (2D) and three-dimensional (3D) echo predictors of MitraClip response, and impact of MitraClip on mitral annular geometry, are uncertain. METHODS: The study population comprised patients with advanced (> moderate) MR undergoing MitraClip. Mitral annular geometry was quantified on pre-procedural 2D transthoracic echocardiography (TTE) and intra-procedural 3D transesophageal echocardiography (TEE); 3D TEE was used to measure MitraClip induced changes in annular geometry. Optimal MitraClip response was defined as ≤mild MR on follow-up (mean 2.7 ± 2.5 months) post-procedure TTE. RESULTS: Eighty patients with advanced MR underwent MitraClip; 41% had optimal response (≤mild MR). Responders had smaller pre-procedural global left ventricular (LV) end-diastolic size and mitral annular diameter on 2D TTE (both p ≤ 0.01), paralleling smaller annular area and circumference on 3D TEE (both p = 0.001). Mitral annular size yielded good diagnostic performance for optimal MitraClip response (AUC 0.72, p < 0.01). In multivariate analysis, sub-optimal MitraClip response was independently associated with larger pre-procedural mitral annular area on 3D TEE (OR 1.93 per cm2/m2 [CI 1.19-3.13], p = 0.007) and global LV end-diastolic volume on 2D TTE (OR 1.29 per 10 ml/m2 [CI 1.02-1.63], p = 0.03). Substitution of 2D TTE derived mitral annular diameter for 3D TEE data demonstrated a lesser association between pre-procedural annular size (OR 5.36 per cm/m2 [CI 0.95-30.19], p = 0.06) and sub-optimal MitraClip response. Matched pre- and post-procedural TEE analyses demonstrated MitraClip to acutely decrease mitral annular area and circumference (all p < 0.001) as well as mitral tenting height, area, and volume (all p < 0.05): Magnitude of MitraClip induced reductions in mitral annular circumference on intra-procedural 3D TEE was greater among patients with, compared to those without, sub-optimal MitraClip response (>mild MR) on followup TTE (p = 0.017); greater magnitude of device-induced annular reduction remained associated with sub-optimal MitraClip response even when normalized for pre-procedure annular circumference (p = 0.028). CONCLUSIONS: MitraClip alters mitral annular geometry as quantified by intra-procedural 3D TEE. Pre-procedural mitral annular dilation and magnitude of device-induced reduction in mitral annular size on 3D TEE are each associated with sub-optimal therapeutic response to MitraClip.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Ecocardiografía Tridimensional , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino
18.
Catheter Cardiovasc Interv ; 91(4): 765-773, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28470996

RESUMEN

OBJECTIVES: Determine the comparative impact of small prosthesis size on transcatheter and surgical aortic valve replacement (SAVR) outcomes. BACKGROUND: Patients with small aortic annuli tend to have worse postoperative outcomes and hemodynamics. We sought to describe surgical outcomes in patients with very small aortic annuli and then compare early hemodynamic and clinical outcomes in patients undergoing surgical or transcatheter aortic valve replacement (TAVR) with the smallest available valves to assist in optimal prosthesis selection for this challenging patient population. METHODS: A retrospective single-center study comparing patient data from 2143 patients undergoing SAVR with valves having a true internal diameter (ID) of ≥19 mm with 130 patients receiving surgical valves with true ID's <19 mm (SmSAVR). Outcomes of SmSAVR patients were then compared with 40 patients undergoing TAVR receiving small valves (SmTAVR). A representative SmSAVR cohort was then compared with the SmTAVR patients for post-operative hemodynamics. RESULTS: Receiving a small surgical valve may significantly increase 1-year mortality compared with standard-sized surgical valves (HR 1.93; 95% confidence interval 1.03-3.61). SmTAVR patients had significantly shorter lengths of stay than SmSAVR (median 5 vs. 9 days), and significantly better postoperative hemodynamic profiles (mean gradient 13.4 ± 7.8 vs. 18.1 ± 8.4 mm Hg, P = 0.006, peak velocity of 2.5 ± 0.6 vs. 2.9 ± 0.6 m/s, P = 0.003). CONCLUSIONS: TAVR is a safe and reasonable option for patients with small aortic annuli and is associated with shorter hospital stays and more favorable postoperative hemodynamic outcomes compared with SAVR. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Toma de Decisiones Clínicas , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Xenoinjertos , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Selección de Paciente , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
J Interv Cardiol ; 31(5): 543-552, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30225907

RESUMEN

This article is a continuation of our previously published annual reviews of transcatheter aortic valve replacement (TAVR). In 2017, TAVR further established a foothold in the management of intermediate risk patients with the publication of SURTAVI trial. Randomized trials also addressed the use of cerebral protection during TAVR and single versus dual antiplatelet therapy after TAVR. Newer generation valve systems continued to be studied for their efficacy and safety. This paper summarizes the major studies published in 2017.


Asunto(s)
Estenosis de la Válvula Aórtica , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Humanos , Pronóstico , Ajuste de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
20.
Eur Heart J ; 38(38): 2879-2887, 2017 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-29019612

RESUMEN

AIMS: Transthyretin cardiac amyloidosis (ATTR-CA) has been reported in patients with aortic stenosis (AS) but its prevalence and phenotype are not known. We examine elderly patients with severe symptomatic AS undergoing transcatheter aortic valve replacement (TAVR) and determine the prevalence and phenotype of ATTR-CA non-invasively. METHODS AND RESULTS: We performed technetium-99m pyrophosphate (99mTc-PYP) cardiac scintigraphy prospectively on patients who underwent TAVR, to screen for ATTR-CA. Transthoracic echocardiography and speckle-strain imaging were performed. We assessed the association of several parameters with ATTR-CA using multivariable logistic regression and constructed receiver operating curves to evaluate the best predictors of ATTR-CA. Among 151 patients (mean age 84 ± 6 years, 68% men), 16% (n = 24) screened positive for ATTR-CA with 99mTc-PYP scintigraphy. Compared with patients without ATTR-CA, ATTR-CA patients had a thicker interventricular septum (1.3 vs. 1.1 cm, P = 0.007), higher left ventricular (LV) mass index (130 vs. 98 g/m2, P = 0.002), and lower stroke volume index (30 vs. 36 mL/m2, P = 0.009). ATTR-CA patients had advanced diastolic dysfunction with higher E/A ratio (2.3 vs. 0.9, P = 0.001) and lower deceleration time (176 vs. 257 ms, P < 0.0001); impairment in systolic function with lower ejection fraction (48% vs. 56%, P = 0.011), myocardial contraction fraction (26 vs. 41, P < 0.0001), and average of lateral and septal mitral annular tissue Doppler S' (4.0 vs. 6.6 cm/s, P < 0.0001). While ATTR-CA patients had more impaired global longitudinal strain (-12 vs. -16%, P = 0.007), relative apical longitudinal strain was the same regardless of ATTR-CA diagnosis (0.98 vs. 0.98, P = 0.991). Average S' best predicted ATTR-CA in multivariable logistic regression (odds ratio 16.67 per 1 cm/s decrease with AUC 0.96, 95% confidence interval 0.90-0.99, P = 0.002) with a value ≤6 conferring 100% sensitivity for predicting a positive 99mTc-PYP amyloid scan. CONCLUSIONS: Transthyretin cardiac amyloidosis is prevalent in 16% of patients with severe calcific AS undergoing TAVR and is associated with a severe AS phenotype of low-flow low-gradient with mildly reduced ejection fraction. Average tissue Doppler mitral annular S' of < 6 cm/s may be a sensitive measure that should prompt a confirmatory 99mTc-PYP scan and subsequent testing for ATTR-CA. Prospective assessment of outcomes after TAVR is needed in patients with and without ATTR-CA.


Asunto(s)
Neuropatías Amiloides Familiares/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Cardiomiopatías/complicaciones , Calcificación Vascular/complicaciones , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Femenino , Humanos , Masculino , Fenotipo , Estudios Prospectivos , Cintigrafía , Radiofármacos , Volumen Sistólico/fisiología , Pirofosfato de Tecnecio Tc 99m , Reemplazo de la Válvula Aórtica Transcatéter , Calcificación Vascular/cirugía , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA