Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Aesthet Surg J ; 44(3): 311-316, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-37707558

RESUMEN

BACKGROUND: The safety of gluteal fat grafting is a global concern in plastic surgery. OBJECTIVE: The goal of this study was to test whether fat grafting to the buttocks with Auto Stop Reach (ASR) technology prevents penetration from the subcutaneous space into the fascia and muscle layers of the buttocks. METHODS: Fat transfer simulation was performed with blue dye on 8 fresh tissue cadaver buttocks by 3 board-certified plastic surgeons (S.S.K., S.C., B.W.). An open control was utilized to visualize the process in the different anatomic layers, and all of the other procedures were performed blindly, akin to live surgery. After blue dye transfer reached maximum capacity (ranging from 400-800 mL per buttock), dissection of the anatomical layers of the buttocks was performed to determine the plane(s) of injection. RESULTS: Blue dye fat transfer injection to the buttocks did not penetrate the gluteal fascia or muscle layers from the subcutaneous space while using ASR. CONCLUSIONS: Auto Stop Reach technology supports the safety of gluteal fat transfer in the subcutaneous space by board-certified plastic surgeons.


Asunto(s)
Procedimientos de Cirugía Plástica , Cirugía Plástica , Humanos , Grasa Subcutánea/trasplante , Tejido Subcutáneo/cirugía , Procedimientos de Cirugía Plástica/efectos adversos , Inyecciones , Nalgas/cirugía , Tejido Adiposo/trasplante
2.
Dermatol Surg ; 49(1): 48-53, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36533796

RESUMEN

BACKGROUND: Unwanted lateral fat most prominently affects the female population and may cause self-esteem issues. OBJECTIVE: To investigate the effectiveness and safety of synchronized high-intensity focused electromagnetic (HIFEM) + radiofrequency (RF) for the treatment of lateral thigh adipose tissue. MATERIALS AND METHODS: Ninety-three subjects (21-70 year old) received 4, 30-minute HIFEM + RF treatments of the lateral thighs. Magnetic resonance imaging (MRI) of the treated area was obtained at baseline, 1, 3, and 6 months post-treatment to document the changes in fat layer thickness. Furthermore, digital photographs, circumference measurements of the lateral thighs, subjects' satisfaction questionnaires, and therapy safety and comfort were documented. RESULTS: Magnetic resonance imaging revealed a significant reduction of fat tissue in the saddlebag region peaking at 3 months (-18 ± 5.5 mm; N = 51). The thigh circumference measured at 3 predefined levels decreased on average by 2.3 cm, with the greatest change at the level of 10 cm below the infragluteal fold (-3.5 cm, 3-month follow-up). Results were maintained at 6 months. No adverse events were recorded. The therapy was found comfortable with a high satisfaction rate. CONCLUSION: High-intensity focused electromagnetic + RF treatment to the lateral thigh area demonstrated effectiveness in long-term fat thickness reduction by MRI imaging. Secondary endpoint showed simultaneous effectiveness and safety.


Asunto(s)
Ondas de Radio , Muslo , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Ondas de Radio/efectos adversos , Obesidad , Radiación Electromagnética , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Resultado del Tratamiento
3.
Aesthet Surg J ; 43(8): 920-927, 2023 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-36883601

RESUMEN

BACKGROUND: With age, facial muscles lose the ability to complete contractions properly, resulting in limitation of facial expressions and fat shifting, and leading to skin creases and wrinkling. OBJECTIVES: The aim of this study was to determine the effects of the novel high intensity facial electromagnetic stimulation (HIFES) technology combined with synchronized radiofrequency on delicate facial muscles, using an animal porcine model. METHODS: Eight (n = 8, 60-80 kg) sows were divided into the active group (n = 6) and the control group (n = 2). The active group underwent four 20-minute treatments with radiofrequency (RF) and HIFES energies. The control group was not treated. Histology samples of muscle tissue were collected by a punch biopsy (6 mm in diameter) from the treatment area of each animal at baseline, 1-month, and 2-month follow-up. The evaluation included staining of the obtained tissue slices with hematoxylin and eosin and Masson's trichrome to determine the changes in muscle mass density, number of myonuclei, and muscle fibers. RESULTS: The active group showed muscle mass density increase (by 19.2%, P < .001), together with elevated numbers of myonuclei (by 21.2%, P < .05) and individual muscle fibers, which increased from 56.8 ± 7.1 to 68.0 ± 8.6 (P < .001). In the control group, no significant changes were seen in any of the studied parameters throughout the study (P > .05). Finally, no adverse events or side effects were observed in the treated animals. CONCLUSIONS: The results document favorable changes after the HIFES + RF procedure at the level of the muscle tissue, which may be of great importance in terms of maintenance of facial appearance in human patients.


Asunto(s)
Cara , Músculos Faciales , Humanos , Animales , Porcinos , Femenino , Modelos Animales , Ondas de Radio/efectos adversos , Piel
4.
Aesthet Surg J ; 40(12): NP686-NP693, 2020 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-32103232

RESUMEN

BACKGROUND: Several studies investigating high-intensity focused electromagnetic (HIFEM) treatments have recently been published. However, due to the novelty of the procedure, long-term data are still missing. OBJECTIVES: The aim of this study was to evaluate changes in abdominal tissues on average 1 year after a series of HIFEM treatments, to determine the long-term durability of patients' original body responses. METHODS: Magnetic resonance imaging (MRI) or computed tomography (CT) scanning were performed on 21 patients a mean of 332.6 [88.5] days after their original HIFEM treatment series. The scans were evaluated by a blinded radiologist for abdominal muscle thickness, subcutaneous fat changes, and abdominal separation. The results were compared with the MRI/CT-assisted measurements taken at baseline and 6-week follow-up. Correlations between collected data sets were calculated and tested. The incidence of any adverse events related to earlier treatments was monitored. RESULTS: When comparing the 1-year follow-up measurements with the baseline, the MRI/CT-assisted calculations revealed mean reductions of 14.63% (2.97 [2.11] mm) in fat, 19.05% (1.89 [0.88] mm) in muscle thickening, and 10.46% (1.96 [1.71] mm) in diastasis recti. All changes were significant (P < 0.05) and not related to weight fluctuations (P > 0.05). The baseline width of diastasis positively correlated with the degree of improvement at follow-up. No adverse events were reported. CONCLUSION: The HIFEM-induced muscle hypertrophy, fat reduction, and reduction in abdominal separation were maintained 1-year posttreatment. This suggests long-term durability of the original bodily response, which needs to be verified by continuing follow-up of this group and by further studies.


Asunto(s)
Magnetoterapia , Abdomen/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
5.
Lasers Surg Med ; 51(1): 40-46, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30302767

RESUMEN

OBJECTIVES: This study introduces an initial evaluation of a novel High-Intensity Focused Electromagnetic (HIFEM) technology. The primary goal is to quantify any effects the treatments may have on abdominal tissues, as well as to establish hypotheses for future research of this technology. METHODS: Twenty-two patients received four abdominal treatments using the EMSCULPT device (BTL Industries Inc., Boston, MA). Anthropometric evaluations were recorded and digital photographs were taken at baseline, at 2 months, and at 6 months post-treatments. The MRI without contrast determined by vertertebras T12 and S1 (FIESTA and FSPRG sequences) was used to measure dimensions in coronal cross-sectional images of abdominal muscle and fatty tissues, in order to assess any anatomical changes induced by the application. RESULTS: Analysis of the same MRI slices verified by tissue artefacts showed a statistically significant (all P < 0.0001) average 18.6% reduction of adipose tissue thickness, 15.4% increase in rectus abdominis muscle thickness, and 10.4% reduction in rectus abdominus separation (diastasis recti) as measured from the medial border of the muscle 2 months post-treatment. More significant improvements were observed in patients with BMI 18.5-24.9 (classified as "normal"). MRI data from 6-month follow-up suggest the changes can be preserved in longer term. Tape measurements showed on average 3.8 cm subumbilical circumference reduction. The weight of the subjects did not change significantly (average -0.5 lb; P > 0.05). No adverse events were reported. CONCLUSIONS: MRI, considered as a highly precise diagnostic method, revealed simultaneous muscle growth, fat reduction and reduced abdominal separation at 2 months and at 6 months post treatments, unrelated with dieting. Further research should investigate the exact physiological processes which stand behind the tissue changes observed in this study. Lasers Surg. Med. 51:40-46, 2019. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.


Asunto(s)
Contorneado Corporal/métodos , Magnetoterapia/métodos , Imagen por Resonancia Magnética , Grasa Subcutánea Abdominal/diagnóstico por imagen , Grasa Subcutánea Abdominal/efectos de la radiación , Adulto , Estética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos
6.
Aesthetic Plast Surg ; 43(2): 490-497, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30276456

RESUMEN

BACKGROUND: Bacterial biofilms have been implicated with breast implant complications including capsular contracture and anaplastic large-cell lymphoma. The actual mechanisms for either are still under active investigation and are not clear. Due to their increased surface area, implants with textured surfaces may harbor greater biofilm loads than those with smooth surfaces. METHODS: Biofilm formation on the outer surface material was compared using implants with various surface areas and roughness, including Natrelle® (Smooth), SmoothSilk®/SilkSurface® (Silk), VelvetSurface ® (Velvet), Siltex®, and Biocell®. The roughness and surface area of each material were assessed using non-contact profilometry. Bacterial attachment (2 h) and biofilm formation (24 h) were evaluated for Staphylococcus epidermidis, Pseudomonas aeruginosa, and Ralstonia pickettii over nine independent experiments using a CDC biofilm reactor and viable plate counts (VPCs) as well as confocal scanning laser microscopy. VPCs of the textured implants were compared relative to the Smooth implant. RESULTS: Surface areas increased with roughness and were similar among the three least rough implants (Smooth, Silk, and Velvet) and among the roughest implants (Siltex and Biocell). Overall, VPC indicated there was significantly more bacterial attachment and biofilm formation on the Siltex and Biocell implants than the Silk or Velvet implants, although there were differences between species and time points. CSLM confirmed the formation of thicker biofilms on the implants with rougher surface textures. CONCLUSION: This in vitro study confirmed that implant surfaces with rougher texture, resulting in more surface area, harbored greater biofilm loads than those with smoother surfaces. NO LEVEL ASSIGNED: This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Asunto(s)
Adhesión Bacteriana , Biopelículas , Implantes de Mama/microbiología , Pseudomonas aeruginosa/fisiología , Ralstonia pickettii/fisiología , Staphylococcus epidermidis/fisiología , Diseño de Prótesis
7.
Aesthet Surg J ; 39(Suppl_3): S95-S102, 2019 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-30958549

RESUMEN

BACKGROUND: Although general guidelines are available for established silicone gel breast implants, the unique characteristics of the latest Motiva implants warrant specific guidelines. OBJECTIVES: This study aimed to generate consensus recommendations and summarize expert-based advice to better understand current surgical practices and to establish guidelines for surgeons transitioning from other implant devices to the Motiva implants. METHODS: A survey was compiled by 12 plastic surgeon experts in aesthetic and reconstructive breast surgery and 1 biotechnology scientist, and distributed to 36 plastic surgeons to establish a consensus on the use of these devices. Surgical techniques, complication rates, and implant selection were among the topics discussed. RESULTS: The experts agreed on 3 core principles regarding the use of Motiva Round and Ergonomix implants. Firstly, the dissected pocket needs to be close fitting and steps must be taken to prevent expansion of the pocket. Secondly, implant selection must be individualized. Finally, surgical planning and technique must be carefully considered. When questioned about problems they had ecountered, 84.6% of the experts agreed that they experienced fewer overall complications and 76.9% confirmed reduced capsular contracture rates with these devices. Overall, 84.6% of the experts favored selecting Motiva Ergonomix implants over Round implants to achieve a more natural look. In addition, 92.3% of the experts agreed that Motiva implants, due to their innovative technology, reduce the risk of anaplastic large-cell lymphoma. CONCLUSIONS: This international consensus of leading practitioners will assist plastic surgeons with patient selection, preoperative planning, and surgical technique. These recommendations are designed to optimize surgical outcomes, resulting in lower overall complication rates, more natural-looking breasts, and highly satisfied patients.


Asunto(s)
Bioingeniería , Implantación de Mama/instrumentación , Implantes de Mama , Implantación de Mama/métodos , Femenino , Encuestas de Atención de la Salud , Humanos , Satisfacción del Paciente , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis
8.
J Drugs Dermatol ; 17(11): 1229-1232, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30500146

RESUMEN

Objective: Surgical intervention has been the only method to improve the aesthetic appearance of buttocks apart from physical exercising. This study evaluates the efficacy of high intensity focused electro-magnetic (HIFEM) treatments as a non-invasive solution for improvement of buttocks through toning and lifting of gluteal muscles. Materials and Methods: A total of 75 patients (aged 22-59) were treated using a device with HIFEM technology which stimulates gluteal muscles (EMSCULPT, BTL Industries, Boston, MA). The protocol included four 30-minute treatments. Patients' weight was monitored throughout the study. Standard photographs were taken at the baseline, after the 4th treatment, and at the 1-month follow-up. Two 7-point Likert scale questionnaires were used to evaluate patients' buttock and treatment satisfaction. Total score of buttock satisfaction was calculated as a sum of all individual questions to reflect the overall perception of patients' buttocks. The level of comfort during procedures was assessed on a visual analog scale (VAS). Results: The overall buttock satisfaction score (range, 4-28) of all subjects improved from 13.1±5.7 at baseline to 18.4±5.2 after the treatment and 18.9±5.1 at follow-up. For subjects with initial buttock dissatisfaction the scores improved from 8.7±1.6 to 16.3±3.1 after the treatment and to 17.3±3.1 at follow-up. The average score of all treatment satisfaction questions (range, 1-7) was 5.2±1.2 immediately after the treatments and 5.1±1.3 at follow-up. In total, patients initially dissatisfied with the appearance of their buttocks reported a significant 85% improvement after the fourth treatment. Immediately after the fourth treatment, all the subjects reported that their buttocks felt more lifted and toned. Results were maintained at one-month follow-up. Weight of the patients didn't change significantly. Digital photographs showed aesthetic improvements of the buttocks for most of the patients. No adverse events were reported. Conclusion: The results show that the investigated device safely and effectively improves the aesthetic appearance of buttocks non-invasively. The treatments not only resulted in a significant visual improvement but also increased patient confidence and satisfaction. The procedure is suitable for patients seeking improvement in tone, shape, lift, and tightness of the buttocks. J Drugs Dermatol. 2018;17(11):1229-1232.


Asunto(s)
Nalgas/anatomía & histología , Técnicas Cosméticas , Estética , Magnetoterapia/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Resultado del Tratamiento , Adulto Joven
9.
Dev Dyn ; 246(11): 946-955, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28850761

RESUMEN

BACKGROUND: The transcriptional co-repressor Sin3 is highly conserved from yeast to vertebrates and has multiple roles controlling cell fate, cell cycle progression, and senescence programming. Sin3 proteins recruit histone deacetylases and other chromatin modifying factors to specific loci through interactions with transcription factors including Myc, Rest, p53 and E2F. Most vertebrates have two Sin3 family members (sin3a and sin3b), but zebrafish have a second sin3a paralogue. In mice, sin3a and sin3b are essential for embryonic development. Sin3b knockout mice show defects in growth as well as bone and blood differentiation. RESULTS: To study the requirement for Sin3b during development, we disrupted zebrafish sin3b using CRISPR-Cas9, and studied the effects on early development and locomotor behavior. CONCLUSIONS: Surprisingly, Sin3b is not essential in zebrafish. sin3b mutants show a decrease in fitness, small size, changes to locomotor behavior, and delayed bone development. We did not detect a role for Sin3b in cell proliferation. Our analysis of the sin3b mutant revealed a more nuanced requirement for zebrafish Sin3b than would be predicted from analysis of mutants in other species. Developmental Dynamics 246:946-955, 2017. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Desarrollo Óseo/genética , Locomoción/genética , Proteínas Represoras/genética , Proteínas de Pez Cebra/genética , Pez Cebra/anomalías , Animales , Pez Cebra/anatomía & histología , Pez Cebra/genética , Pez Cebra/fisiología
10.
Planta ; 246(4): 673-685, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28631209

RESUMEN

MAIN CONCLUSION: Exogenous phenylalanine stunted annual ryegrass but not switchgrass or winter grain rye, with deuterium incorporation up to 3% from phenyalanine-d 8 . Toxicity to duckweed varied with illumination intensity and glucose uptake. Isotopic labeling of biomolecules through biosynthesis from deuterated precursors has successfully been employed for both structural studies and metabolic analysis. Phenylalanine is the precursor of many products synthesized by plants, including the monolignols used for synthesis of lignin. Possible allelochemical effects of phenylalanine have not been reported, although its deamination product cinnamic acid is known to have deleterious effects on root elongation and growth of several plant species. The effects of phenylalanine and its deuterated analog phenylalanine-d 8 added to growth media were studied for annual ryegrass (Lolium multiflorum), winter grain rye (Secale cereale), and switchgrass (Panicum virgatum) cultivated under hydroponic conditions. Growth of annual ryegrass was inhibited by phenylalanine while switchgrass and rye were not significantly affected. Growth was less affected by deuterated phenylalanine-d 8 than by its protiated counterpart, which may be a typical deuterium kinetic isotope effect resulting in slower enzymatic reaction rates. Deuterium incorporation levels of 2-3% were achieved in biomass of switchgrass and annual ryegrass. Both protiated and deuterated phenylalanine were moderately toxic (IC25 values 0.6 and 0.8 mM, respectively) to duckweed (Lemna minor) grown using a 12 h diurnal cycle under photoautotrophic conditions. A significant increase in toxicity, greater for the deuterated form, was noted when duckweed was grown under higher intensity, full spectrum illumination with a metal halide lamp compared to fluorescent plant growth lamps emitting in the blue and red spectral regions. Supplementation with glucose increased toxicity of phenylalanine consistent with synergy between hexose and amino acid uptake that has been reported for duckweed.


Asunto(s)
Araceae/efectos de los fármacos , Deuterio/metabolismo , Lolium/efectos de los fármacos , Panicum/efectos de los fármacos , Fenilalanina/toxicidad , Secale/efectos de los fármacos , Alelopatía , Araceae/crecimiento & desarrollo , Araceae/metabolismo , Biomasa , Germinación , Glucosa/metabolismo , Hidroponía , Lolium/crecimiento & desarrollo , Lolium/metabolismo , Panicum/crecimiento & desarrollo , Panicum/metabolismo , Fenilalanina/química , Hojas de la Planta/efectos de los fármacos , Hojas de la Planta/crecimiento & desarrollo , Hojas de la Planta/metabolismo , Raíces de Plantas/efectos de los fármacos , Raíces de Plantas/crecimiento & desarrollo , Tallos de la Planta/efectos de los fármacos , Tallos de la Planta/crecimiento & desarrollo , Tallos de la Planta/metabolismo , Secale/crecimiento & desarrollo , Secale/metabolismo
11.
J Cosmet Laser Ther ; 19(8): 444-450, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28665165

RESUMEN

INTRODUCTION: A new temperature-controlled device has been used as a percutaneous radio frequency probe to treat lax submental and other facial areas. It has significant advantages over other esthetic devices as it provides the dual benefit of fat lipolysis and skin tightening. Our goal here is to present consensus recommendations for treating the aging neck. METHODS: A panel of 11 expert physicians convened in Dallas, Texas, on October 15, 2016 to arrive at a consensus on the best current practice for submental skin tightening and contour improvement. Prior to the meeting, a comprehensive review of the literature was performed and a survey was sent to esthetic dermatologists and plastic surgeons who were queried about various aspects of neck rejuvenation. RESULTS: The literature search revealed 10 different technologies for neck rejuvenation evaluated in double-blind (n = 2) and single-blind (n = 1) clinical trials and other clinical evaluations (n = 21). The survey was sent via an email to 1248 individuals and was completed by 92 respondents. Review of the data and discussion by meeting attendees generated eight consensus recommendations. DISCUSSION: Subdermal monopolar radio frequency represents an effective means for disrupting fat volume and skin tightening of the face, neck, and jawline. For suitable patients, this treatment can be used to achieve significant esthetic improvements.


Asunto(s)
Técnicas Cosméticas/instrumentación , Cuello , Terapia por Radiofrecuencia , Rejuvenecimiento , Envejecimiento de la Piel , Consenso , Humanos , Ondas de Radio/efectos adversos
18.
J Cosmet Dermatol ; 23(3): 824-829, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38235951

RESUMEN

BACKGROUND: The application of radiofrequency (RF) and HIFES on the body provides improvement in skeletal muscle tissue, reduction in fatty tissue, reorganization of connective tissue, and skin texture improvement. However, overall facial appearance relies on both skin and underlying structures, specifically muscles and connective tissue which have to be treated as one unit to achieve proper care while preserving fatty layers that define youth facial appearance. AIMS: The aim of this study is to find whether the effect of novel RF + HIFES is safe and can induce the lifting of soft tissue and overall improvement in facial appearance. METHODS: In this study, 21 subjects were enrolled. The therapy was administered in four 20-min treatments on the forehead and cheeks. Photographs were evaluated by a Global Aesthetic Improvement Score (GAIS) and linear measurements of facial tissue lifting at 1- and 3-month follow-ups. Volumetric changes in the cheek area were investigated as well. The patients' satisfaction, safety, and comfort were documented throughout the study. RESULTS: The data indicated improvement in overall facial appearance, and 23% of average lifting was found in brows (p = 3.14 × 10-12 ) and cheeks (p = 6.00 × 10-15 ). The assessment of digital photographs showed an improvement in 100% of patients at 3-month follow-up. The treatments were safe, accompanied by high therapy comfort and subject satisfaction of 98%. CONCLUSIONS: The treatment by simultaneous RF and HIFES technology produces significant changes to the overall facial appearance, characterized by the lifting of facial tissues.


Asunto(s)
Técnicas Cosméticas , Envejecimiento de la Piel , Humanos , Adolescente , Cara , Satisfacción del Paciente , Piel
19.
Plast Reconstr Surg ; 153(4): 967-975, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37199437

RESUMEN

SUMMARY: A biosensor uses a biological molecule to measure a chemical reaction. Wearable biosensors that attach to the body externally, including tooth enamel biosensors, contact lens biosensors, sweat biosensors, and skin tattoo biosensors, are in development. Nanoparticle-based biosensors are being developed to allow for the early detection of cancerous biomarkers. Applications relevant to plastic surgery include the development of biosensors that can detect metastatic breast cancer cells, bioimpedance spectroscopy, and intraoperative point-of-care diagnostics.


Asunto(s)
Técnicas Biosensibles , Humanos , Técnicas Biosensibles/métodos
20.
Plast Reconstr Surg ; 153(1): 204e-217e, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-37075274

RESUMEN

SUMMARY: Artificial intelligence (AI) has been a disruptive technology within health care, from the development of simple care algorithms to complex deep-learning models. AI has the potential to reduce the burden of administrative tasks, advance clinical decision-making, and improve patient outcomes. Unlocking the full potential of AI requires the analysis of vast quantities of clinical information. Although AI holds tremendous promise, widespread adoption within plastic surgery remains limited. Understanding the basics is essential for plastic surgeons to evaluate the potential uses of AI. This review provides an introduction of AI, including the history of AI, key concepts, applications of AI in plastic surgery, and future implications.


Asunto(s)
Procedimientos de Cirugía Plástica , Cirujanos , Humanos , Inteligencia Artificial , Algoritmos , Atención a la Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA