1.
Med Dosim ; 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38556401

RESUMEN

Accurate information on set-up error during radiotherapy is essential for determining the optimal number of treatments in hypofractionated radiotherapy for prostate cancer. This necessitates careful control by the radiotherapy staff to assess the patient's condition. This study aimed to develop an evaluation method of the temporal trends in a patient's specific prostate movement during treatment using image matching and margin values. This study included 65 patients who underwent prostate volumetric modulated arc therapy (mean treatment time, 87.2 s). Set-up errors were assessed using bone, inter-, and intra-fraction marker matching across 39 fractions. The set-up margin was determined by dividing the four periods into 39 fractions using Stroom's formula and correlation coefficient. The intra-fraction set-up error was biased in the anterior-superior (AS) direction during treatment. The temporal trend of set-up errors during radiotherapy slightly increased based on bone matching and inter-fraction marker matching, with a 1.6-mm difference in the set-up margin fractions 11 to 20. The correlation coefficient of the mean prostate movement during treatment significantly decreased in the superior-inferior direction, while remaining high in the left-right and anterior-posterior directions. Image matching contributed significantly to the improvement of set-up errors; however, careful attention is needed for prostate movement in the AS direction, particularly during short treatment times. Understanding the trend of set-up errors during the treatment period is essential in numerical information sharing on patient condition and evaluating the margins for tailored hypo-fractionated radiotherapy, considering the facility's image-guided radiation therapy technology.

2.
Phys Med Biol ; 60(18): 7229-43, 2015 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-26348273

RESUMEN

This study developed a dedicated real-time monitoring system to detect intra-fractional head motion in intracranial radiotherapy using pressure sensors. The dedicated real-time monitoring system consists of pressure sensors with a thickness of 0.6 mm and a radius of 9.1 mm, a thermoplastic mask, a vacuum pillow, and a baseplate. The four sensors were positioned at superior-inferior and right-left sides under the occipital area. The sampling rate of pressure sensors was set to 5 Hz. First, we confirmed that the relationship between the force and the displacement of the vacuum pillow follows Hook's law. Next, the spring constant for the vacuum pillow was determined from the relationship between the force given to the vacuum pillow and the displacement of the head, detected by Cyberknife target locating system (TLS) acquisitions in clinical application. Finally, the accuracy of our system was evaluated by using the 2 × 2 confusion matrix. The regression lines between the force, y, and the displacement, x, of the vacuum pillow were given by y = 3.8x, y = 4.4x, and y = 5.0x when the degree of inner pressure was -12 kPa,-20 kPa, and -27 kPa, respectively. The spring constant of the vacuum pillow was 1.6 N mm(-1) from the 6D positioning data of a total of 2999 TLS acquisitions in 19 patients. Head motions of 1 mm, 1.5 mm, and 2 mm were detected in real-time with the accuracies of 67%, 84%, and 89%, respectively. Our system can detect displacement of the head continuously during every interval of TLS with a resolution of 1-2 mm without any radiation exposure.


Asunto(s)
Técnicas Biosensibles , Irradiación Craneana/instrumentación , Neoplasias de Cabeza y Cuello/radioterapia , Inmovilización/instrumentación , Posicionamiento del Paciente/instrumentación , Presión , Sistemas de Computación , Humanos , Inmovilización/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA