Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Tuberc Lung Dis ; 22(6): 622-627, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29862945

RESUMEN

SETTING: There remains a lack of effective and inexpensive diagnostic tools for active tuberculosis (TB) disease. Testing immune responses to proteins secreted by Mycobacterium tuberculosis, such as MPT64, may be a diagnostic option. OBJECTIVE: To evaluate the sensitivity and specificity of a patch test using MPT64 for the diagnosis of active TB disease. DESIGN: This randomised, double-blind, placebo-controlled, prospective study in Lima, Peru, involved 55 healthy controls and 457 symptomatic individuals referred for routine TB testing by the National TB Control Programme. All subjects underwent a comprehensive diagnostic workup, and received an active patch on one arm and a placebo patch on the opposite arm, which were read after 4 days. RESULTS: Eighty-one (18%) of the symptomatic participants were classified as having definite TB, while an additional 98 (21%) had probable TB. The patch tests performed the same in both groups, with a sensitivity of 27% and specificity of 74%. The area under the receiver operating characteristic curve was 0.495 (95%CI 0.425-0.565). CONCLUSIONS: Contrary to existing literature, the MPT64 patch was not sensitive and specific to detect active TB. Given the potential of the test, understanding possible differences in the protein source or underlying genetic factors should be explored further.


Asunto(s)
Tamizaje Masivo/métodos , Mycobacterium tuberculosis/aislamiento & purificación , Pruebas del Parche/métodos , Tuberculosis Pulmonar/diagnóstico , Adulto , Método Doble Ciego , Femenino , Humanos , Masculino , Perú/epidemiología , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Tuberculosis Pulmonar/epidemiología , Adulto Joven
2.
Arch Soc Esp Oftalmol ; 81(11): 647-52, 2006 Nov.
Artículo en Español | MEDLINE | ID: mdl-17136638

RESUMEN

PURPOSE: To show the utility of optical coherence tomography (OCT) for studying the anterior segment and to explain its potential advantages as compared to ultrasonic biomicroscopy (UBM). MATERIALS AND METHODS: We have described the findings in 5 patients with different pathologies of the anterior segment, all of whom were studied with UBM and OCT-3 adjusted for the anterior segment. There were 2 cases of an acute attack of closed angle glaucoma, 1 case of rubeosis iridis, 1 case of penetrating ocular trauma and 1 case of a primary stromal iris cyst. RESULTS: OCT was found to be as useful as UBM in detecting angle closure in patients affected by an acute attack of glaucoma. In addition, OCT was more comfortable for the patient and faster than UBM in obtaining images, with the exploration mean time using OCT being less than five minutes while that with UBM was over ten minutes. OCT has also been demonstrated to be a safe and valuable non-contact examination in other iris pathologies such as rubeosis iridis, for checking the permeability of iridotomies and even for studying iris masses such as primary stromal iris cysts. In these entities OCT may reach a higher resolution than ultrasonic biomicroscopy. CONCLUSION: OCT-3, with an adjustable focus, can obtain images from the scleral angle, as well as from other ocular structures like the iris, thus assisting in the diagnosis of numerous pathologies.


Asunto(s)
Segmento Anterior del Ojo , Oftalmopatías/diagnóstico , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica , Adulto , Femenino , Humanos , Masculino , Microscopía Acústica , Persona de Mediana Edad
4.
Arch Soc Esp Oftalmol ; 89(12): 495-9, 2014 Dec.
Artículo en Inglés, Español | MEDLINE | ID: mdl-24365400

RESUMEN

CLINICAL CASE: A 5 year-old child diagnosed with moderate anisometropic amblyopia secondary to primary cyst of iris pigment epithelium. He was evaluated with ultrasound biomicroscopy (BMU) and optical coherence tomography (OCT) of anterior segment. DISCUSSION: The OCT, although with some limitations, is a useful tool to study the anterior segment. It is probably more recommendable than BMU in the childhood.


Asunto(s)
Ambliopía/etiología , Enfermedades Hereditarias del Ojo/complicaciones , Iris/anomalías , Epitelio Pigmentado Ocular/anomalías , Tomografía de Coherencia Óptica , Astigmatismo/etiología , Catarata/complicaciones , Preescolar , Enfermedades Hereditarias del Ojo/diagnóstico por imagen , Humanos , Iris/diagnóstico por imagen , Masculino , Microscopía Acústica , Epitelio Pigmentado Ocular/diagnóstico por imagen , Lámpara de Hendidura
5.
Radiologia ; 50(5): 393-400, 2008.
Artículo en Español | MEDLINE | ID: mdl-19055917

RESUMEN

OBJECTIVE: To determine the usefulness of multislice computed tomography (MSCT) in the evaluation of renal vascular disease against a gold standard of digital subtraction angiography (DSA). MATERIAL AND METHODS: We evaluated 30 patients with arterial hypertension and/or kidney failure that underwent MSCT to rule out a vascular cause and DSA to confirm a vascular cause suspected at MSCT. MSCT examinations were performed on a 10-detector scanner with intravenous administration of 80 ml of iodinated contrast (300 mg iodine/ml) at a flow rate of 5 ml/s. A total of 71 renal arteries, 56 main and 15 accessory, were evaluated. Arterial stenoses were classified as: grade 0 (normal artery), grade I (stenosis < 50%), grade II (> or = 50% and < 70%), grade III (> or = 70%), grade IV (occlusion). Stenosis > or = grade II was considered hemodynamically significant. RESULTS: The findings at MSCT and DSA were identical in 56 (78.8%) renal arteries; MSCT overestimated the degree of stenosis in 13 (18.3%) cases. All grade III stenoses were detected at MSCT. In the diagnosis of hemodynamically significant stenosis, MSCT had a sensitivity of 96.5%, specificity 78.5%, accuracy 85.9%, positive predictive value 75.6%, and negative predictive value 97%. CONCLUSIONS: MSCT is a good noninvasive imaging technique for the evaluation of renal vessels; it is useful for screening patients with kidney disease to rule out potentially treatable vascular causes.


Asunto(s)
Obstrucción de la Arteria Renal/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos
6.
Head Neck ; 23(3): 189-93, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11428448

RESUMEN

OBJECTIVE: To identify whether there are differences in the use of drains and, if used, which would be the best for thyroid surgery. DESIGN: Prospective, longitudinal, comparative, randomized study. SETTING: General Hospital Mexico City, Mexico. PATIENTS AND METHODS: One hundred fifty patients were studied, divided into three groups: group A, without drain; group B, with a Penrose drain; and group C, with a semirigid suction drain. On the basis of the preoperative diagnosis, subtotal or total thyroidectomy or hemithyroidectomy was performed. Analyzed variables were thyroid volume (TV), transoperative bleeding (TOB), flow of postoperative drain (PD), length of hospital stay (HS), and complications, such as seromas, hematomas, and hemorrhages. Statistical Analysis. Multiple variant analysis, using Scheffe's procedure and chi2. RESULTS: Group A had an average TOB of 107 mL, HS of 2 days, and TV of 153.24 mL with two complications (seromas). Group B had an average TOB of 149.8 mL, HS of 2.6 days, TV of 175.4 mL, PD of 29.6 mL, and three complications (2 seromas and 1 hematoma). Group C had an average TOB of 161.5 mL, HS of 3.11 days, TV of 173.5 mL, PD of 25.84 mL, and two seromas. No differences existed regardless of the type of drain used between groups B and C. CONCLUSION: Statistical analysis showed that the size of the gland, diagnosis, type of surgery, transoperative bleeding, and complications are not valid arguments to leave an external drain in thyroid surgery. No advantages were found between the Penrose or the semirigid suction drains. Hospital stay was longer in patients with the suction drain. These results support the notion that the use of wound drainage cannot substitute for meticulous dissection and transoperative hemostasis.


Asunto(s)
Drenaje/instrumentación , Enfermedades de la Tiroides/diagnóstico , Enfermedades de la Tiroides/cirugía , Tiroidectomía/métodos , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Valores de Referencia , Sensibilidad y Especificidad , Resultado del Tratamiento , Cicatrización de Heridas/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA