Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circ J ; 77(10): 2535-41, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23877732

RESUMEN

BACKGROUND: The implantable loop recorder (ILR) is a useful tool for diagnosing paroxysmal conditions potentially related to arrhythmias. Most investigations have focused on selected clinical studies or high-volume centers. The aim of this study was to evaluate the indications and outcomes of the ILR in real clinical practice. METHODS AND RESULTS: This was a prospective, multicenter registry of patients undergoing ILR implantation for clinical indications (April 2006-December 2008). Clinical characteristics (symptoms, arrhythmias, treatments) were recorded in a database. Follow-up data at 1 year or after the occurrence of the first episode were also recorded. Total enrollment: 743 patients (male, 413, 55.6%; 64.9 ± 16 years); 228 (30.7%) had structural heart disease (SHD), and 183 (24.6%), bundle branch block (BBB). Recurrent syncope (76.4%) was the most common indication for implantation. Complete follow-up was obtained for 680 patients (91.5%). Three hundred and twenty-five patients (48%) presented 414 events, with a final diagnosis in 230 patients (70.8% of patients with events; 33.1% of patients with follow-up). Syncope secondary to bradyarrhythmia was the most frequent diagnosis. Similar rates of final diagnoses were noted in subgroups of SHD, BBB and normal heart. Regarding the cause of implantation, higher event rates were registered among patients with recurrent syncope. CONCLUSIONS: One-third of patients obtained a final diagnosis with the ILR, independent of the baseline characteristics. Only the cause of implantation provided different rates of final diagnosis.


Asunto(s)
Arritmias Cardíacas , Bases de Datos Factuales , Electrodos Implantados , Sistema de Registros , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , España
2.
Magn Reson Imaging ; 91: 9-15, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35526803

RESUMEN

BACKGROUND: The number of patients with cardiac implantable electronic devices in whom magnetic resonance imaging (MRI) is indicated is constantly increasing. The potential risk of electromagnetic interference has limited its use and it is still contraindicated by the Food and Drug Administration in some cases. The aim of this study is to evaluate the safety and efficacy of MRI in these patients. METHODS: A prospective registry comprising patients with a pacemaker (PM) or implantable cardioverter-defibrillator (ICD), MRI-conditional or not, who were candidates for MRI (at 1.5 T) with no suitable alternative diagnostic technique. All devices were programmed before the procedure and patients were monitored throughout the test. Clinical, electrical, and technical parameters were evaluated before and after MRI. RESULTS: 147 MRI examinations (132 PM and 15 ICD) were performed. There were no clinical events or significant differences in the electrical parameters of the leads after MRI. A variation in the impedance of the ventricular leads was detected, although the difference was not clinically relevant. In one patient with a PM, a failure in release of the safety impulse was detected in the auto-threshold test, although the threshold was correctly determined. In 11 of the 17 thoracic MRIs, image artifacts were detected, preventing the diagnosis in two of them. CONCLUSIONS: In patients with cardiac implantable electronic devices, MRIs performed under a specific protocol has been shown to be safe in the short term even in the thoracic region, as well as interpretable in most cases.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos
3.
Cardiol J ; 22(3): 241-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25428732

RESUMEN

BACKGROUND: The implantable loop recorder (ILR) is a useful tool for diagnosis of syncope or palpitations. Its easy use and safety have extended its use to secondary hospitals (those without an Electrophysiology Lab). The aim of the study was to compare results between secondary and tertiary hospitals. METHODS: National prospective and multicenter registry of patients with an ILR inserted for clinical reasons. Data were collected in an online database. The follow-up ended when the first diagnostic clinical event occurred, or 1 year after implantation. Data were analyzed according to the center of reference; hospitals with Electrophysiology Lab were considered Tertiary Hospitals, while those hospitals without a lab were considered Secondary Hospitals. RESULTS: Seven hundred and forty-three patients (413 [55.6%] men; 65 ± 16 year-old): 655 (88.2%) from Tertiary Centers (TC) and 88 (11.8%) from Secondary Centers (SC). No differences in clinical characteristics between both groups were found. The electrophysiologic study and the tilt table test were conducted more frequently in Tertiary Centers. Follow-up was conducted for 680 (91.5%) patients: 91% in TC and 94% in SC. There was a higher rate of final diagnosis among SC patients (55.4% vs. 30.8%; p < 0.001). Tertiary Hospital patients showed a trend towards a higher rate of neurally mediated events (20% vs. 4%), while bradyarrhythmias were more frequent in SC (74% vs. 60%; p = 0.055). The rate of deaths and adverse events was similar in both populations. CONCLUSIONS: Patients with an ILR in SC and TC have differences in terms of the use of complementary tests, but not in clinical characteristics. There was a higher rate of diagnosis in Secondary Hospital patients.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrodos Implantados , Centros de Atención Secundaria , Síncope/diagnóstico , Telemetría/instrumentación , Anciano , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Sistema de Registros , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , España , Síncope/mortalidad , Síncope/fisiopatología , Centros de Atención Terciaria , Pruebas de Mesa Inclinada
4.
Rev Esp Cardiol (Engl Ed) ; 68(3): 226-33, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25677720

RESUMEN

This article discusses the main advances in cardiac arrhythmias and pacing published between 2013 and 2014. Special attention is given to the interventional treatment of atrial fibrillation and ventricular arrhythmias, and on advances in cardiac pacing and implantable cardioverter defibrillators, with particular reference to the elderly patient.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Sistema de Conducción Cardíaco/fisiopatología , Arritmias Cardíacas/fisiopatología , Humanos , Guías de Práctica Clínica como Asunto
6.
Rev Esp Cardiol ; 61 Suppl 1: 132-50, 2008 Feb.
Artículo en Español | MEDLINE | ID: mdl-18341941

RESUMEN

This review summarizes recent scientific developments in ambulatory monitoring and its legal implications in appropriately selected patients. It also considers how new cardiac pacing devices can be used in the clinical monitoring of atrial fibrillation, sleep apnea and, in transplant patients, heart failure and transplant rejection. In addition, the system of accreditation for cardiac pacing services in Spain is outlined, with a focus on process development and quality indicators. Finally, the scientific articles on cardiac pacing that made the greatest impact in 2007 are summarized.


Asunto(s)
Estimulación Cardíaca Artificial , Acreditación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA