Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Foot Ankle Surg ; 26(1): 78-84, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30581061

RESUMEN

BACKGROUND: A medializing calcaneal osteotomy is frequently performed to correct adult-acquired flatfoot deformities, but there is lack of data on the associated three-dimensional variables defining the final correction. The aim of this study was to assess the correlation between the pre-operative hindfoot valgus deformity and calcaneal osteotomy angles and the post-operative calcaneal displacement. METHODS: Weight-bearing CT scans obtained pre- and post-operatively were retrospectively analyzed for sixteen patients. Corresponding three-dimensional bone models were used to measure valgus deformity pre- and post-operatively, inclination of the osteotomy and displacement of the calcaneus. Linear regression was conducted to assess the relationship between these measurements. RESULTS: On average, the hindfoot valgus changed from 13.1° (±4.6) pre-operatively to 5.7° (±4.3) post-operatively. A mean inferior displacement of 3.2mm (±1.3) was observed along the osteotomy with a mean inclination of 54.6° (±5.6), 80.5° (±10.7), -13.7° (±15.7) in the axial, sagittal and coronal planes, respectively. A statistically significant positive relationship (p<.05, R2=0.6) was found between the pre-operative valgus, the axial osteotomy inclination, and the inferior displacement. CONCLUSIONS: This study shows that the degree of pre-operative hindfoot valgus and the axial osteotomy angle are predictive factors for the amount of post-operative inferior displacement of the calcaneus. These findings demonstrate the added value of a computer-based pre-operative planning in clinical practice. Level of evidence II Prospective comparative study.


Asunto(s)
Calcáneo/cirugía , Pie Plano/diagnóstico , Imagenología Tridimensional , Osteotomía/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Calcáneo/diagnóstico por imagen , Femenino , Pie Plano/fisiopatología , Pie Plano/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Soporte de Peso , Adulto Joven
2.
J Orthop Traumatol ; 21(1): 16, 2020 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-32876778

RESUMEN

BACKGROUND: Computer navigation and patient-specific instrumentation for total ankle arthroplasty have still to demonstrate their theoretical ability to improve implant positioning and functional outcomes. The purpose of this paper is to present a new and complete total ankle arthroplasty customization process for severe posttraumatic ankle joint arthritis, consisting of patient-specific 3D-printed implant and instrumentation, starting from a ligament-compatible design. CASE PRESENTATION: The new customization process was proposed in a 57-year-old male patient and involved image analysis, joint modeling, prosthesis design, patient-specific implant and instrumentation development, relevant prototyping, manufacturing, and implantation. Images obtained from a CT scan were processed for a 3D model of the ankle, and the BOX ankle prosthesis (MatOrtho, UK) geometries were customized to best fit the model. Virtual in silico, i.e., at the computer, implantation was performed to optimize positioning of these components. Corresponding patient-specific cutting guides for bone preparation were designed. The obtained models were printed in ABS by additive manufacturing for a final check. Once the planning procedure was approved, the models were sent to final state-of-the-art additive manufacturing (the metal components using cobalt-chromium-molybdenum powders, and the guides using polyamide). The custom-made prosthesis was then implanted using the cutting guides. The design, manufacturing, and implantation procedures were completed successfully and consistently, and final dimensions and location for the implant corresponded with the preoperative plan. Immediate post-op X-rays showed good implant positioning and alignment. After 4 months, clinical scores and functional abilities were excellent. Gait analysis showed satisfactory joint moment at the ankle complex and muscle activation timing within normality. CONCLUSIONS: The complete customization process for total ankle arthroplasty provided accurate and reliable implant positioning, with satisfactory short-term clinical outcomes. However, further studies are needed to confirm the potential benefits of this complete customization process. LEVEL OF EVIDENCE: 5.


Asunto(s)
Articulación del Tobillo , Artritis/cirugía , Artroplastia de Reemplazo de Tobillo/instrumentación , Prótesis Articulares , Impresión Tridimensional , Diseño de Prótesis , Artritis/diagnóstico por imagen , Artroplastia de Reemplazo de Tobillo/métodos , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
3.
Knee Surg Sports Traumatol Arthrosc ; 25(12): 3834-3843, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27738741

RESUMEN

PURPOSE: Physiological elongation and orientation of patellar tendon fibres are among the scopes of total knee arthroplasty, but little is known in the three dimensions. The study aims to assess in vitro these variations at the intact and replaced knee, with and without patellar resurfacing. It was hypothesised that fibre patterns differ before and after prosthesis implantation, and between specific prosthesis designs. It was also expected that patellar resurfacing would affect relevant results. METHODS: Measurements from 16 intact cadaver knees free from anatomical defects are here reported using a surgical navigation system. Data were collected at the intact joint and after implantation with cruciate-retaining or posterior-stabilised prosthesis designs, with and without patellar resurfacing. Relevant anatomical landmarks and patellar tendon attachments were digitised. Anatomical reference frames in the femur, tibia and patella were defined to measure component implantation parameters. Representative tendon fibres were defined as the straight line segments joining the two extremities. Changes in length and orientation of these fibres were calculated and reported versus flexion at the intact knee and after prosthesis implantation, both with and without patellar resurfacing. RESULTS: A good intra- and inter-specimen repeatability was found at the intact and replaced knees. In both prosthesis designs, the patterns of fibre lengthening were similar to those in the intact knee, though significant differences were observed before and after patellar resurfacing. Corresponding fibre orientations in the frontal and sagittal planes showed significantly smaller ranges than those in the corresponding intact joints. More natural patterns were observed in the knees implanted with the posterior-stabilised design. Significant correlations were identified between patellar component implantation parameters and both patellar tendon fibre elongation and orientation. CONCLUSIONS: Differences, however small, in patellar tendon fibre elongation and orientation were observed after total knee arthroplasty. The posterior-stabilised design provided better results, whereas patellar resurfacing affected significantly normal patellar function. In the clinical practice, the present findings can contribute to the understanding of current prosthesis designs and patellar resurfacing, recommending also enhanced care during this surgery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Rótula/cirugía , Ligamento Rotuliano/cirugía , Rango del Movimiento Articular/fisiología , Anciano , Fenómenos Biomecánicos , Cadáver , Diseño de Equipo , Femenino , Fémur/cirugía , Humanos , Rodilla/cirugía , Prótesis de la Rodilla , Persona de Mediana Edad , Diseño de Prótesis , Reproducibilidad de los Resultados , Tibia/cirugía
4.
Knee Surg Sports Traumatol Arthrosc ; 22(8): 1719-27, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24408075

RESUMEN

PURPOSE: In total knee arthroplasty, surgical navigation systems provide tibio-femoral joint (TFJ) tracking for relevant bone preparation, disregarding the patello-femoral joint (PFJ). Therefore, the important intra-operative assessment of the effect of component positioning, including the patella, on the kinematics of these two joints is not available. The objective of this study is to explore in vivo whether accurate tracking of the patella can result in a more physiological TFJ and PFJ kinematics during surgery. METHODS: Ten patients underwent navigated knee replacement with patellar resurfacing. A secondary system was used to track patellar motion and PFJ kinematics using a special tracker. Patellar resection plane position and orientation were recorded using an instrumented probe. During all surgical steps, PFJ kinematics was measured in addition to TFJ kinematics. RESULTS: Abnormal PFJ motion patterns were observed pre-operatively at the impaired knee. Patellar resection plane orientation on sagittal and transverse planes of 3.9° ± 9.0° and 0.4° ± 4.1° was found. A good restoration of both TFJ and PFJ kinematics was observed in all replaced knees after resurfacing, in particular the rotations in the three anatomical planes and medio-lateral patellar translation. CONCLUSIONS: Patella tracking results in nearly physiological TFJ and PFJ kinematics in navigated knee arthroplasty with resurfacing. The intra-operative availability also of PFJ kinematics can support the positioning not only of the patellar component in case of resurfacing, but also of femoral and tibial components.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fémur/fisiopatología , Articulación de la Rodilla/fisiopatología , Articulación Patelofemoral/fisiopatología , Tibia/fisiopatología , Anciano , Fenómenos Biomecánicos , Femenino , Fémur/cirugía , Humanos , Artropatías/cirugía , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Rótula/cirugía , Articulación Patelofemoral/cirugía , Rango del Movimiento Articular , Cirugía Asistida por Computador , Tibia/cirugía
5.
Knee Surg Sports Traumatol Arthrosc ; 22(12): 3157-62, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24972998

RESUMEN

PURPOSE: Unicompartmental knee arthroplasty (UKA) has shown a higher rate of revision compared with total knee arthroplasty. The success of UKA depends on prosthesis component alignment, fixation and soft tissue integrity. The tibial cut is the crucial surgical step. The hypothesis of the present study is that tibial component malalignment is correlated with its risk of loosening in UKA. METHODS: This study was performed in twenty-three patients undergoing primary cemented unicompartmental knee arthroplasties. Translations and rotations of the tibial component and the maximum total point motion (MTPM) were measured using radiostereometric analysis at 3, 6, 12 and 24 months. Standard radiological evaluations were also performed immediately before and after surgery. Varus/valgus and posterior slope of the tibial component and tibial-femoral axes were correlated with radiostereometric micro-motion. A survival analysis was also performed at an average of 5.9 years by contacting patients by phone. RESULTS: Varus alignment of the tibial component was significantly correlated with MTPM, anterior tibial sinking, varus rotation and anterior and medial translations from radiostereometry. The posterior slope of the tibial component was correlated with external rotation. The survival rate at an average of 5.9 years was 89%. The two patients who underwent revision presented a tibial component varus angle of 10° for both. CONCLUSIONS: There is correlation between varus orientation of the tibial component and MTPM from radiostereometry in unicompartmental knee arthroplasties. Particularly, a misalignment in varus larger than 5° could lead to risk of loosening the tibial component. LEVEL OF EVIDENCE: Prognostic studies-retrospective study, Level II.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Artropatías/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Tibia/cirugía , Anciano , Anciano de 80 o más Años , Desviación Ósea/cirugía , Femenino , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Falla de Prótesis , Análisis Radioestereométrico , Estudios Retrospectivos , Rotación , Tibia/diagnóstico por imagen
6.
Gait Posture ; 109: 41-48, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38266422

RESUMEN

BACKGROUND: Ankle-foot orthoses (AFOs) are orthopaedic devices often prescribed to treat foot drop. For patients who are not satisfied with off-the-shelf solutions, custom AFOs personalized to the patient's lower limb anatomy are required. Dynamic AFOs provide stability while allowing for physiological ankle mobility in the stance phase of walking. RESEARCH QUESTION: Can a morphology-based dynamic custom AFO made of fiberglass-reinforced polyamide restore a quasi-normal gait pattern and improve comfort in patients with foot drop? METHODS: In this pilot study, the legs and feet of ten foot drop patients (age=64.9 ± 11.4 years; BMI=26.2 ± 2.1 kg/m2) were scanned using a Kinect-based 3D scanner. A custom AFO was designed and produced for each patient using a fiberglass-reinforced polyamide through selective laser sintering. To assess kinematics, skin markers were placed on relevant bony landmarks according to a validated protocol. Each patient was instructed to walk at a self-selected comfortable speed under three conditions: wearing the custom AFO, wearing an off-the-shelf orthosis (Codivilla spring), and without any AFO (shod condition). Muscle activation in the tibialis anterior, gastrocnemius, rectus femoris and biceps femoris muscles in both legs was recorded using wireless sEMG sensors. The comfort and of each AFO was evaluated using a Visual Analogue Scale. RESULTS: The custom AFO resulted in significant increase of stride length and walking speed compared to the shod condition. Except for the hip joint, which exhibited greater maximum flexion and reduced range of motion, the kinematic parameters of all other joints were similar to those observed in a healthy control population. Furthermore, the custom AFO received significantly higher comfort scores compared to the Codivilla spring. SIGNIFICANCE: This study has provided evidence supporting the effectiveness of custom orthotic solutions in restoring lower limb kinematics and improving the perceived comfort in foot drop patients compared to off-the-shelf solutions.


Asunto(s)
Ortesis del Pié , Vidrio , Neuropatías Peroneas , Humanos , Persona de Mediana Edad , Anciano , Proyectos Piloto , Nylons , Articulación del Tobillo , Debilidad Muscular , Paresia , Fenómenos Biomecánicos , Marcha/fisiología
7.
Knee Surg Sports Traumatol Arthrosc ; 21(10): 2375-83, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23114867

RESUMEN

PURPOSE: To compare intra-operative knee joint kinematic measurements immediately after total knee replacement with those of the same patients post-operatively at 6-month follow-up. METHODS: Fifteen patients who underwent total knee arthroplasty were analysed retrospectively. Eight were implanted with one prosthesis design and seven with another. The intra-operative measurements were performed by using a standard knee navigation system. This provided accurate three-dimensional positions and orientations for the femur and tibia by corresponding trackers pinned into the bones. At 6-month follow-up, the patients were analysed by standard three-dimensional video-fluoroscopy of the replaced knee during stair climbing, chair rising and step-up. Relevant three-dimensional positions and orientations were obtained by an iterative shape-matching procedure between the silhouette contours and the CAD-model projections. A number of traditional kinematic parameters were calculated from both measurements to represent the joint motion. RESULTS: Good post-operative replication of the intra-operative measurements was observed for most of the variables analysed. The statistical analysis also supported the good consistency between the intra- and post-operative measurements. CONCLUSIONS: Intra-operative kinematic measurements, accessible by a surgical navigation system, are predictive of the following motion performance of the replaced knees as experienced in typical activities of daily living. LEVEL OF EVIDENCE: Prognostic studies--investigating natural history and evaluating the effect of a patient characteristic, Level II.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Imagenología Tridimensional , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/instrumentación , Fenómenos Biomecánicos , Fluoroscopía , Estudios de Seguimiento , Humanos , Periodo Intraoperatorio , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Periodo Posoperatorio , Estudios Retrospectivos , Cirugía Asistida por Computador/instrumentación , Grabación en Video
8.
Front Bioeng Biotechnol ; 11: 1198120, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37545891

RESUMEN

Introduction: The "postural control system" acts through biomechanical strategies and functional neuromuscular adaptations to maintain body balance under static and dynamic conditions. Postural stability and body weight distribution can be affected by external sensory inputs, such as different visual stimuli. Little information is available about the influence of visual receptors on stabilometric and plantar pressure parameters. The aim of this study was to analyze variability, correlations, and changes in these parameters under open- (OE) and closed-eye (CE) conditions. Methods: A total of 31 stabilometric and plantar pressure parameters were acquired in 20 young and healthy adults during baropodometric examination performed in bipedal standing under both visual conditions. Variability of parameters was evaluated via the coefficient of variation, correlation analysis via Pearson's R2, and statistical differences via the Wilcoxon test. Results: High intra-subject repeatability was found for all plantar pressure parameters and CoP-speed (CV < 40%) under OE and CE conditions, while CoP-sway area (CoPsa) and length surface function (LSF) showed larger variability (CV > 50%). Mean and peak pressures at midfoot and total foot loads showed the least number of significant correlations with other parameters under both visual conditions, whereas the arch-index and rearfoot loads showed the largest number of significant correlations. The limb side significantly affected most plantar pressure parameters. A trend of larger LSF and lower CoPsa and mean and peak pressures at the right forefoot was found under the CE condition. Discussion: The present study provides a deeper insight into the associations between postural stability and foot load. Interesting postural adaptations, particularly with respect to different visual stimuli, the effect of the dominant side, and the specific role of the midfoot in balance control were highlighted.

9.
Knee Surg Sports Traumatol Arthrosc ; 20(3): 495-502, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21625830

RESUMEN

PURPOSE: The incorrect restoration of the joint line during TKA can result in joint instability, anterior knee pain, limited range of motion, and joint stiffness. The joint line level is usually measured only on pre- and post-operative radiographs. Current knee navigation systems can now potentially support intra-operatively joint line restoration by controlling the exact amount of the bone-cartilage removed and the corresponding overall thickness of the components implanted. The aim of this study was to assess how well the joint line level is restored and the tibiofemoral overstuffing prevented when standard knee surgical navigation is used carefully also with these purposes. Intra-operative measurements during navigated TKA were taken. METHODS: Sixty-seven primary TKAs were followed prospectively. The variation before and after prosthesis component implantation of the joint line level, both in the femoral and tibial reference, was measured intra-operatively by an instrumented probe. Overstuffing was measured as the difference between the overall craniocaudal thickness of the femoral and tibial prosthesis components inserted and the thickness of the bone-cartilage removed. RESULTS: A significant elevation in the joint line level after prosthesis implantation was found with respect to the tibial reference (1.9 ± 2.4 mm, mean ± SD), very little to the femoral reference (0.3 ± 2.1 mm), perhaps accounted for the femur-first operative technique utilized. Overstuffing was on the average of 2.2 ± 3.0 mm. CONCLUSIONS: These results suggest that a knee navigation system can also support well a proper restoration of the joint line level and limit the risk of overstuffing when relevant measurements are taken carefully during operation. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Femenino , Fémur/anatomía & histología , Humanos , Inestabilidad de la Articulación/prevención & control , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Ajuste de Prótesis
10.
J Biomech ; 142: 111239, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35940017

RESUMEN

Ankle-Foot Orthoses (AFOs) are the most common devices prescribed to support the ankle and restore a quasi-normal gait pattern in drop-foot patients. AFO stiffness is possibly the main mechanical property affecting foot and ankle biomechanics. A variety of methods to evaluate this property have been reported, however no standard procedure has been validated and widely used. This study is reporting the repeatability of a novel apparatus to measure AFO stiffness in ideal frictionless conditions. The apparatus is based on a servo-hydraulic testing machine and allows to apply a displacement-controlled rotation of the AFO shell, simulating the physiological ankle dorsi/plantarflexion movement. The repeatability of the apparatus in measuring AFO stiffness in dorsiflexion and plantarflexion was assessed intra- and inter-session in a sample of standard polypropylene AFOs of different sizes (Codivilla spring). The repeatability of the apparatus in measuring the AFO stiffness was high. The Intra- and Inter-session Coefficient of Variation ranged between 0.02 ÷ 1.3 % and 1.3 ÷ 5 %, respectively. The Intra Class Correlation Coefficient ranged between 0.999 ÷ 1 intra- and 0.993 ÷ 0.997 inter-session. AFOs stiffness was observed to increase with the AFO size. The setup is easy to replicate and can be implemented with any torsion-controlled servo-hydraulic testing machine and has resulted simple to use and flexible enough to adapt to AFOs with different sizes. The frictionless contacts characterizing the apparatus make it possible to measure the ideal AFO stiffness by excluding the effect of the fixation methods to the leg and help to improve the repeatability of measurements.


Asunto(s)
Ortesis del Pié , Tobillo , Articulación del Tobillo , Fenómenos Biomecánicos , Marcha/fisiología , Humanos
11.
Proc Inst Mech Eng H ; 225(8): 725-35, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21922950

RESUMEN

In-depth comprehension of human knee kinematics is necessary in prosthesis and orthosis design and in surgical planning but requires complex mathematical models. Models based on one-degree-of-freedom equivalent mechanisms have replicated well the passive relative motion between the femur and tibia, i.e. the knee joint motion in virtually unloaded conditions. In these mechanisms, fibres within the anterior and posterior cruciate and medial collateral ligaments were taken as isometric and anatomical articulating surfaces as rigid. A new one-degree-of-freedom mechanism is analysed in the present study, which includes isometric fibres within the two cruciates and a spherical pair at the pivot point of the nearly spherical motion as measured for this joint. Bounded optimization was applied to the mechanism to refine parameter first estimates from experimental measurements on four lower-limb specimens and to best-fit the experimental motion of these knees. Relevant results from computer simulations were compared with those from one previous equivalent mechanism, which proved to be very accurate in a former investigation. The spherical mechanism represented knee motion with good accuracy, despite its simple structure. With respect to the previous more complex mechanism, the less satisfactory results in terms of replication of natural motion were counterbalanced by a reduction of computational costs, by an improvement in numerical stability of the mathematical model, and by a reduction of the overall mechanical complexity of the mechanism. These advantages can make the new mechanism preferable to the previous ones in certain applications, such as the design of prostheses, orthoses, and exoskeletons, and musculoskeletal modelling of the lower limb.


Asunto(s)
Simulación por Computador , Articulación de la Rodilla/fisiología , Modelos Anatómicos , Rango del Movimiento Articular/fisiología , Fenómenos Biomecánicos , Ingeniería Biomédica , Ligamentos Colaterales/fisiología , Fémur/fisiología , Humanos , Rodilla/fisiología , Movimiento/fisiología , Aparatos Ortopédicos/tendencias , Tibia/fisiología
12.
Knee Surg Sports Traumatol Arthrosc ; 18(7): 949-54, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20162258

RESUMEN

The Patellar Tendon Angle is strongly correlated with both patello-femoral and tibio-femoral joint kinematics. Thus, the Patellar Tendon Angle might be regarded as a concise indicator of the antero-posterior translation of the femur with respect to the tibia. Twelve subjects, who had undergone total knee arthroplasty, were investigated by video-fluoroscopy during step-up/down. The kinematics at the replaced knee was reconstructed by means of 3D fluoroscopy. The Patellar Tendon Angle and the knee-flexion angle were measured on sagittal fluoroscopic images with software designed for the purpose. The slope of the linear trend of the Patellar Tendon Angle versus knee-flexion angle relationship correlated significantly with the mean (p = 0.001), most anterior (p = 0.001), and most posterior (p = 0.016) position reached by the femur over the tibia. The Patellar Tendon Angle versus knee-flexion angle relationship provides relevant information about the anterior or posterior positioning of the femur over the tibia, but it cannot be interpreted as quantification of the actual antero-posterior translation of the femur over the tibia.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/fisiología , Ligamento Rotuliano/fisiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Fluoroscopía , Humanos , Procesamiento de Imagen Asistido por Computador , Articulación de la Rodilla/diagnóstico por imagen , Persona de Mediana Edad , Ligamento Rotuliano/diagnóstico por imagen , Rango del Movimiento Articular/fisiología
13.
Proc Inst Mech Eng H ; 224(9): 1121-32, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21053776

RESUMEN

In-depth comprehension of human joint function requires complex mathematical models, which are particularly necessary in applications of prosthesis design and surgical planning. Kinematic models of the knee joint, based on one-degree-of-freedom equivalent mechanisms, have been proposed to replicate the passive relative motion between the femur and tibia, i.e., the joint motion in virtually unloaded conditions. In the mechanisms analysed in the present work, some fibres within the anterior and posterior cruciate and medial collateral ligaments were taken as isometric during passive motion, and articulating surfaces as rigid. The shapes of these surfaces were described with increasing anatomical accuracy, i.e. from planar to spherical and general geometry, which consequently led to models with increasing complexity. Quantitative comparison of the results obtained from three models, featuring an increasingly accurate approximation of the articulating surfaces, was performed by using experimental measurements of joint motion and anatomical structure geometries of four lower-limb specimens. Corresponding computer simulations of joint motion were obtained from the different models. The results revealed a good replication of the original experimental motion by all models, although the simulations also showed that a limit exists beyond which description of the knee passive motion does not benefit considerably from further approximation of the articular surfaces.


Asunto(s)
Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Ingeniería Biomédica , Cadáver , Simulación por Computador , Femenino , Humanos , Técnicas In Vitro , Masculino , Modelos Anatómicos , Modelos Biológicos
14.
J Biomech ; 40(8): 1871-6, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17014854

RESUMEN

Despite the fundamental value of wear simulation studies to assess wear resistance of total joint replacements, neither specialised simulators nor established external conditions are available for the human ankle joint. The aim of the present study was to verify the suitability of a knee wear simulator to assess wear rates in ankle prostheses, and to report preliminary this rate for a novel three-component total ankle replacement design. Four intact 'small' size specimens of the Box ankle were analysed in a four-station knee wear simulator. Special component-to-actuator holders were manufactured and starting spatial alignment of the three-components was sought. Consistent load and motion cycles representing conditions at the ankle joint replaced exactly with the prosthesis design under analysis were taken from a corresponding mechanical model of the stance phase of walking. The weight loss for the three specimens, after two million cycles, was 32.68, 14.78, and 62.28mg which correspond to a linear penetration of 0.018, 0.008, and 0.034mm per million-cycle, respectively for the specimens #1, #2, and #3. The knee wear simulator was able to reproduce load-motion patterns typical of a replaced ankle. Motion of the meniscal bearing in between the tibial and talar components was smooth, this component remaining in place and in complete congruence with the metal components throughout the test.


Asunto(s)
Articulación del Tobillo/fisiopatología , Biomimética/instrumentación , Análisis de Falla de Equipo/instrumentación , Prótesis Articulares , Articulación de la Rodilla/fisiopatología , Diseño de Prótesis/instrumentación , Falla de Prótesis , Articulación del Tobillo/cirugía , Biomimética/métodos , Análisis de Falla de Equipo/métodos , Humanos , Diseño de Prótesis/métodos
15.
Gait Posture ; 25(3): 453-62, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16965916

RESUMEN

This paper proposes a new protocol designed to track a large number of foot segments during the stance phase of gait with the smallest possible number of markers, with particular clinical focus on coronal plane alignment of the rear-foot, transverse and sagittal plane alignment of the metatarsal bones, and changes at the medial longitudinal arch. The shank, calcaneus, mid-foot and metatarsus were assumed to be 3D rigid bodies. The longitudinal axis of the first, second and fifth metatarsal bones and the proximal phalanx of the hallux were also tracked independently. Skin markers were mounted on bony prominences or joint lines, avoiding the course of main tendons. Trajectories of the 14 markers were collected by an eight-camera motion capture system at 100 Hz on a population of 10 young volunteers. Three-dimensional joint rotations and planar angles were calculated according to anatomically based reference frames. The marker set was well visible throughout the stance phase of gait, even in a camera configuration typical of gait analysis of the full body. The time-histories of the joint rotations and planar angles were well repeatable among subjects and consistent with clinical and biomechanical knowledge. Several dynamic measurements were originally taken, such as elevation/drop of the medial longitudinal arch and of three metatarsal bones, rear-foot to fore-foot rotation and transverse plane deformation of the metatarsus. The information obtained from this protocol, consistent with previous clinical knowledge, enhanced our understanding of the dynamics of the human foot during stance.


Asunto(s)
Pie/fisiología , Marcha/fisiología , Movimiento/fisiología , Adulto , Fenómenos Biomecánicos , Femenino , Pie/anatomía & histología , Huesos del Pie/anatomía & histología , Huesos del Pie/fisiología , Articulaciones del Pie/fisiología , Humanos , Masculino , Modelos Biológicos , Fotogrametría , Rotación
16.
Med Biol Eng Comput ; 45(3): 305-13, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17295023

RESUMEN

The paper presents a theoretical model of the ankle joint, i.e. tibio-talar articulation, which shows how the articular surfaces and the ligaments, acting together as a mechanism, can control the passive kinematics of the joint. The authors had previously shown that, in virtually unloaded conditions, the ankle behaves as a single degree-of-freedom system, and that two ligament fibres remain nearly isometric throughout the flexion arc. Two different equivalent spatial parallel mechanisms together with corresponding kinematic models were formulated. These assumed isometricity of fibres within the calcaneal-fibular and tibio-calcaneal ligaments and rigidity of the articulating surfaces, taken as three sphere-plane contacts in one model, and as a single spherical pair in the other. Geometry parameters for the models were obtained from three specimens. Motion predictions compare quite well with the measured motion of the specimens. The differences are accounted for by the simplifications adopted to represent the complex anatomical structures, and might be reduced by future more realistic representations of the natural articular surfaces.


Asunto(s)
Articulación del Tobillo/fisiología , Modelos Biológicos , Rango del Movimiento Articular/fisiología , Fenómenos Biomecánicos , Humanos , Ligamentos Articulares/fisiología
17.
J Orthop Res ; 24(4): 581-7, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16514660

RESUMEN

The relation between prosthesis component kinematics and posterior slope of the tibial component in total knee arthroplasty is much debated. Three-dimensional kinematics of the replaced knee was obtained by video fluoroscopy in 23 knees treated by cruciate-retaining or cruciate-substituting arthroplasty. Relative position and orientation of the metal components were calculated in stair ascending, getting up from and sitting down on a chair, and single step up-and-down. Significant correlations were found between tibial component posterior slope and anteroposterior position of tibiofemoral lateral contact and between this slope and maximum knee flexion. These correlations were task and design specific. However, the average of the tibiofemoral contact positions over all three motor tasks was slightly posterior to the midline of the tibial base plate, reaching at most 84% of its anteroposterior dimension. Performing a posterior slope of the tibial cut does not put total knee arthroplasty with high conforming designs at higher risk of failure, even when large posterior inclinations need to be achieved.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/fisiopatología , Tibia/fisiopatología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Fluoroscopía , Humanos
18.
J Biomech ; 39(8): 1435-43, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-15950979

RESUMEN

Total ankle replacement (TAR) designs have still several important issues to be addressed before the treatment becomes fully acceptable clinically. Very little is known about the performance, in terms of the contact pressures and kinematics of TAR when subjected to daily activities such as level gait. For this purpose, an explicit finite element model of a novel 3-component TAR was developed, which incorporated a previously validated mechanical model of the ankle ligament apparatus. The intermediate mobile polyethylene meniscal bearing was modelled as an elastic-plastic continuum while the articulating surfaces of the tibial and talar metal components as rigid bodies. Overall kinematics, contact pressures and ligament forces were analysed during passive, i.e. virtually unloaded, and active, i.e. stance phase of gait, conditions. Simulation of passive motion predicted similar kinematics as reported previously in an analytical four-bar linkage model. The meniscal bearing was observed to move 5.6 mm posteriorly during the simulated stance and the corresponding antero-posterior displacement of the talar component was 8.3 mm. The predicted pattern and the amount (10.6 degrees ) of internal-external rotation of the ankle complex were found to be in good agreement with corresponding in vivo measurements on normal ankles. A peak contact pressure of 16.8 MPa was observed, with majority of contact pressures below 10 MPa. For most ligaments, reaction forces remain within corresponding physiological ranges. A first realistic representation of the biomechanical behaviour of the human ankle when replaced by prosthetic joints is provided. The applied methodology can potentially be applied to other TAR designs.


Asunto(s)
Articulación del Tobillo , Artroplastia de Reemplazo , Análisis de Elementos Finitos , Marcha , Modelos Biológicos , Prótesis e Implantes , Humanos , Ensayo de Materiales/métodos , Polietileno , Diseño de Prótesis , Rango del Movimiento Articular , Estrés Mecánico , Soporte de Peso
19.
Clin Biomech (Bristol, Avon) ; 21(2): 152-8, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16260075

RESUMEN

BACKGROUND: The knowledge of cartilage wear patterns at the medial tibial plateau is important to understand the main causes of arthritis in varus knees. The most important factors influencing knee arthritis in fact seem to be the severity of the degenerative changes determined by the lower limb mechanical axis and the abnormal knee joint kinematics which frequently results from dysfunction of the anterior cruciate ligament. METHODS: We studied the wear patterns of cartilage damage in 70 medial tibial plateaus resected at operation during total knee arthroplasty indicated for varus osteoarthritic knee. Anterior cruciate ligament and medial meniscus integrity was assessed intra-operatively. Calibrated digital images were used to measure the wear patterns with a standard software tool. The medial compartment of the tibial plateau was divided into six zones, and the amount of cartilage and bone destruction in each zone was classified into two grades. FINDINGS: The wear pattern was found to be highly dependent upon knee varus deformity (Mann Whitney P<0.001) and anterior cruciate ligament integrity (Friedman P<0.0005). Anterior cruciate ligament was found intact in 35.7% of the cases. Wear patterns on intact anterior cruciate ligament knees occurred in the central to medial aspect of the tibial plateau. Anterior cruciate ligament deficient knees had significantly larger wear patterns anteriorly and posteriorly in the most medial region of the medial plateau. INTERPRETATION: These observations suggest altered joint mechanics exist in anterior cruciate ligament deficient varus knees, which would worsen cartilage degeneration and osteoarthritis progression.


Asunto(s)
Cartílago Articular/patología , Deformidades Adquiridas de la Articulación/patología , Articulación de la Rodilla/patología , Osteoartritis de la Rodilla/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Deformidades Adquiridas de la Articulación/etiología , Masculino , Meniscos Tibiales/patología , Persona de Mediana Edad , Tibia
20.
Clin Biomech (Bristol, Avon) ; 21(8): 870-9, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16684581

RESUMEN

BACKGROUND: Many clinical and biomechanical research studies, particularly in orthopaedics, nowadays involve forms of movement analysis. Gait analysis, video-fluoroscopy of joint replacement, pre-operative planning, surgical navigation, and standard radiostereometry would require tools for easy access to three-dimensional graphical representations of rigid segment motion. Relevant data from this variety of sources need to be organised in structured forms. Registration, integration, and synchronisation of segment position data are additional necessities. With this aim, the present work exploits the features of a software tool recently developed within a EU-funded project ('Multimod') in a series of different research studies. METHODS: Standard and advanced gait analysis on a normal subject, in vivo fluoroscopy-based three-dimensional motion of a replaced knee joint, patellar and ligament tracking on a knee specimen by a surgical navigation system, stem-to-femur migration pattern on a patient operated on total hip replacement, were analysed with standard techniques and all represented by this innovative software tool. Segment pose data were eventually obtained from these different techniques, and were successfully imported and organised in a hierarchical tree within the tool. FINDINGS: Skeletal bony segments, prosthesis component models and ligament links were registered successfully to corresponding marker position data for effective three-dimensional animations. These were shown in various combinations, in different views, from different perspectives, according to possible specific research interests. INTERPRETATION: Bioengineering and medical professionals would be much facilitated in the interpretation of the motion analysis measurements necessary in their research fields, and would benefit therefore from this software tool.


Asunto(s)
Ingeniería Biomédica/métodos , Imagenología Tridimensional/métodos , Sistema Musculoesquelético/patología , Anciano , Amputación Quirúrgica , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Gráficos por Computador , Simulación por Computador , Femenino , Marcha , Humanos , Articulación de la Rodilla/anatomía & histología , Modelos Biológicos , Sistema Musculoesquelético/anatomía & histología , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA