Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Mater Chem B ; 3(29): 5971-5977, 2015 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-32262653

RESUMEN

Electrical, label-free monitoring of cells is a non-invasive method for dynamically assessing the integrity of cells for diagnostic purposes. The organic electrochemical transistor (OECT) is a device that has been demonstrated to be advantageous for interfacing with biological systems and had previously been shown to be capable of monitoring electrically tight, resistant, barrier type tissue. Herein, the OECT is demonstrated not only for monitoring of barrier tissue cells such as MDCK I, but also for other, non-barrier tissue adherent cells including HeLa cells and HEK epithelial cells. Transistor performance, expressed as transconductance (gm) is measured as a function of frequency; barrier tissue type cells are shown to have a more abrupt drop in transconductance compared to non-barrier tissue cells, however both tissue types are clearly distinguishable. Simple modelling of the cell layers on the transistor allows extraction of a resistance term (Rc). OECT monitoring shows that barrier tissue cells lose their barrier function in a standard calcium switch assay, but remain adhered to the surface. Re-addition of calcium results in recovery of barrier tissue function. The entire process is continuously followed both electronically and optically. Finally, high resolution fluorescence imaging of live cells labelled with a red fluorescent actin marker demonstrates the versatility of this method for tracking molecular events optically, with direct correlation to electronic readouts.

2.
Phys Med Biol ; 20(2): 235-43, 1975 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1153513

RESUMEN

Neutron production from targets of Be, C, Mo, Cu, Ta and Au bombarded with deuterons of 16, 33 and 50 MeV has been studied at the isochronous cyclotron at Louvain-la-Neuve. Neutron spectra were measured by the time of flight method. The yields of neutrons and gamma rays were also measured, and the greatest ratio of neutrons to gamma rays in the forward direction was found to occur with 50 MeV deuterons on a Be target. The angular distribution of neutrons from Be was measured at 16, 33 and 50 MeV, and neutron spectra were measured as function of angle with 50 MeV deuterons on Be.


Asunto(s)
Deuterio , Neutrones Rápidos , Neutrones , Berkelio , Carbono , Cobre , Oro , Molibdeno , Física Nuclear , Reactores Nucleares , Tantalio
6.
Biol Neonate ; 55(1): 55-62, 1989.
Artículo en Inglés | MEDLINE | ID: mdl-2650746

RESUMEN

Prenatal care in Belgium is characterized by regional variations between the Flemish- and French-speaking communities. Generally, care in the former area is provided by a general practitioner or a gynecologist/obstetrician in private practice, and in the latter by a gynecologist/obstetrician on a private or public basis. The level of use of prenatal care observed is, on average, high, but variations do exist according to the socioeconomic and cultural characteristics of the families and the health care services which they frequent.


Asunto(s)
Atención Prenatal/organización & administración , Bélgica , Femenino , Humanos , Sistemas de Información , Embarazo , Atención Prenatal/normas , Factores Socioeconómicos
11.
Phys Rev C Nucl Phys ; 35(2): 402-406, 1987 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9953784
14.
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA