Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Vasc Surg ; 63(1): 234-6, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24865785

RESUMEN

A delayed secondary open conversion (SOC) after endovascular aneurysm repair may be necessary due to a failing graft. Many surgical techniques can be performed, and one such approach is partial explantation of the graft with resuturing of a new graft to the retained components of the endograft. No guidelines exist with regards to the follow-up of retained endovascular components after a delayed SOC. The theoretical risk of endoleaks remains with retained components, and this case demonstrates the development of a type Ib endoleak after SOC leading to free flow of blood into a partially resected aneurysm sac and causing a symptomatic aneurysm rupture.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/etiología , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Remoción de Dispositivos/efectos adversos , Endofuga/etiología , Procedimientos Endovasculares/instrumentación , Stents , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Rotura de la Aorta/diagnóstico , Rotura de la Aorta/cirugía , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/diagnóstico , Endofuga/cirugía , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Falla de Prótesis , Reoperación , Factores de Tiempo , Resultado del Tratamiento
2.
Indian Pacing Electrophysiol J ; 14(1): 37-43, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24493915

RESUMEN

It is established that cardiac resynchronisation therapy (CRT) reduces mortality and hospitalisation and improves functional class in patients with NYHA class 3-4 heart failure, an ejection fraction of ≤ 35% and a QRS duration of ≥ 120ms. Recent updates in the American guidelines have expanded the demographic of patients in whom CRT may be appropriate. Here we present two cases of complex CRT; one with a conventional indication but occluded central veins and the second with a novel indication for CRT post cardiac transplant.

3.
J Vasc Surg ; 49(4): 866-72, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19341882

RESUMEN

OBJECTIVE: This study assessed if emergency endovascular repair (eEVR) reduces the increase in intra-abdominal compartment pressure and host inflammatory response in patients with ruptured abdominal aortic aneurysm (AAA). METHODS: Thirty patients with ruptured AAA were prospectively recruited. Patients were offered eEVR or emergency conventional open repair (eOR) depending on anatomic suitability. Intra-abdominal pressure was measured postoperatively, at 2 and 6 hours, and then daily for 5 days. Organ dysfunction was assessed preoperatively by calculating the Hardman score. Multiple organ dysfunction syndrome, systemic inflammatory response syndrome, and lung injury scores were calculated regularly postoperatively. Hematologic analyses included serum urea and electrolytes, liver function indices, and C-reactive protein. Urine was analyzed for the albumin-creatinine ratio. RESULTS: Fourteen patients (12 men; mean age, 72.2 +/- 6.2 years) underwent eEVR, and 16 (14 men; mean age, 71.4 +/- 7.0 years) had eOR. Intra-abdominal pressure was significantly higher in the eOR cohort compared with the eEVR group. The eEVR patients had significantly less blood loss (P < .001) and transfused (P < .001) and total intraoperative intravenous fluid infusion (P = .001). The eOR group demonstrated a greater risk of organ dysfunction, with a higher systemic inflammatory response syndrome score at day 5 (P = .005) and higher lung injury scores at days 1 and 3 (P = .02 and P = .02) compared with eEVR. A significant correlation was observed between intra-abdominal pressure and the volume of blood lost and transfused, amount of fluid given, systemic inflammatory response syndrome score, multiple organ dysfunction score, lung injury score, and the length of stay in the intensive care unit and hospital. CONCLUSION: These results suggest that eEVR of ruptured AAA is less stressful and is associated with less intra-abdominal hypertension and host inflammatory response compared with eOR.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Síndromes Compartimentales/prevención & control , Síndrome de Respuesta Inflamatoria Sistémica/prevención & control , Procedimientos Quirúrgicos Vasculares , Abdomen , Anciano , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/complicaciones , Rotura de la Aorta/mortalidad , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea , Síndromes Compartimentales/etiología , Síndromes Compartimentales/mortalidad , Femenino , Fluidoterapia , Humanos , Unidades de Cuidados Intensivos , Tiempo de Internación , Lesión Pulmonar/etiología , Lesión Pulmonar/prevención & control , Masculino , Insuficiencia Multiorgánica/etiología , Insuficiencia Multiorgánica/prevención & control , Presión , Estudios Prospectivos , Medición de Riesgo , Síndrome de Respuesta Inflamatoria Sistémica/etiología , Síndrome de Respuesta Inflamatoria Sistémica/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
4.
JSLS ; 13(1): 73-6, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19366546

RESUMEN

BACKGROUND: Spillage of bile and gallstones due to accidental perforation of the gallbladder wall is often encountered during laparoscopic cholecystectomy. Although spilled stones were once considered harmless, there is increasing evidence that they can result in septic or other potential complications. CASE REPORT: We report a case of spilled gallstones mimicking peritoneal metastases on radiological investigations; diagnosis was confirmed by diagnostic laparoscopy. CONCLUSION: Every effort should be made to retrieve spilled gallstones during laparoscopic cholecystectomy. When all the stones cannot be retrieved, it should be documented in the patient's medical records to avoid delay in the diagnosis of late complications. Diagnostic laparoscopy is useful when the radiological investigations are inconclusive.


Asunto(s)
Colecistectomía Laparoscópica/efectos adversos , Vesícula Biliar/lesiones , Cálculos Biliares/diagnóstico , Complicaciones Intraoperatorias/diagnóstico , Anciano , Diagnóstico Diferencial , Femenino , Vesícula Biliar/cirugía , Cálculos Biliares/cirugía , Humanos , Complicaciones Intraoperatorias/cirugía , Laparoscopía , Neoplasias Peritoneales/diagnóstico , Tomografía Computarizada por Rayos X
5.
Vasc Endovascular Surg ; 41(6): 500-5, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-18166630

RESUMEN

BACKGROUND: Many devices are available for endovascular aneurysm repair (EVAR). Our aim was to analyze morphological effects of the Zenith and Talent systems. METHODS: Patients included underwent EVAR from June 1999 to June 2005 using a Zenith or Talent stent-graft, with computed tomography follow-up. Aortic dimensions over time and clinical outcome were analyzed. RESULTS: Twenty-nine patients with Zenith stent-grafts and 33 with Talent devices were included. Mean preoperative age was similar (75.5+/-6.0 years vs 74.2+/-6.7 years; P=.29). Preoperative neck length was longer in the Zenith group (29.9+/-15.2 mm vs 25.5 +/- 10.8 mm; P=.10), and stent-graft oversizing was greater in the Talent patients (20.2%+/-7.9% vs 23.0% +/- 11.3%). There was proximal aortic dilatation and aneurysm sac shrinkage in each group. Complication rates were comparable, with 83% of both groups free from 10-mm migration. CONCLUSION: Although device designs differ, there is no difference in clinical outcome between Zenith and Talent stent-grafts. Migration rates were not influenced by suprarenal fixation.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/etiología , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada Espiral , Resultado del Tratamiento
6.
Vascular ; 21(1): 39-42, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21715550

RESUMEN

Superior mesenteric artery (SMA) aneurysms are rare but associated with significant mortality (25-40%) when complicated by rupture or thrombosis. Symptomatic SMA aneurysms, asymptomatic aneurysms of ≥2 cm size and pseudoaneurysms need intervention. We report a case of a 6.5-cm symptomatic SMA aneurysm managed by open surgical repair. At intraoperative exploration, the aneurysm was recognized to be a pseudoaneurysm with a narrow neck (1 mm defect in the native vessel) and was dealt by primary repair. Clinical presentation, the role of radiological investigations and management are discussed. Detailed preoperative assessment of the anatomical characters is essential in planning the intervention for SMA aneurysms. The required information can be obtained by selective interventional angiogram or computed tomographic angiogram with three-dimensional reconstruction. Multi-institutional prospective databases might provide better evidence regarding the timing of intervention, treatment modality, postinterventional follow-up and surveillance of patients with mesenteric aneurysms.


Asunto(s)
Aneurisma Falso/cirugía , Arteria Mesentérica Superior/cirugía , Procedimientos Quirúrgicos Vasculares , Aneurisma Falso/diagnóstico por imagen , Femenino , Humanos , Arteria Mesentérica Superior/diagnóstico por imagen , Persona de Mediana Edad , Técnicas de Sutura , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
8.
Vasc Endovascular Surg ; 44(6): 449-53, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20547575

RESUMEN

INTRODUCTION: Reported mortality rates for endovascular repair (EVR) of ruptured abdominal aortic aneurysm (rAAA) vary from 0% to 50%. Selection bias, inaccurate reporting, and lack of uniform reporting standards are responsible for this significant discrepancy. MATERIAL AND METHODS: Existing literature about the classification/reporting systems of rAAA is reviewed. A standard way of reporting rAAA based on the physiological, radiological, and operative findings is proposed. CONCLUSION: The proposed system attempts to provide a universal language of communicating the severity of rupture, address the reporting bias, and allow comparing the outcomes of rAAA.


Asunto(s)
Aneurisma de la Aorta Abdominal/clasificación , Rotura de la Aorta/clasificación , Investigación sobre Servicios de Salud/normas , Garantía de la Calidad de Atención de Salud/normas , Indicadores de Calidad de la Atención de Salud/normas , Terminología como Asunto , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Rotura de la Aorta/cirugía , Aortografía/normas , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/normas , Guías como Asunto , Humanos , Evaluación de Procesos y Resultados en Atención de Salud/normas , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/normas , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad , Procedimientos Quirúrgicos Vasculares/normas
9.
Ulster Med J ; 78(3): 166-70, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19907682

RESUMEN

BACKGROUND: Angiographic assessment is an alternative to computerised tomography (CT) prior to endovascular aneurysm repair (EVAR). We evaluated angiography in aortic neck morphology assessment as an alternative investigation. METHODS: Patients admitted for elective or emergency EVAR were assessed by pre-operative CT and intra-operative angiography. The proximal and distal aortic neck diameters, and neck length were measured. Measurements were expressed as median (95% CI). RESULTS: 35 patients (20 male) were assessed from August 2003 to January 2005 for elective (26) and emergency (9) EVAR. In the overall group, the proximal neck diameter was 22.0mm (21.0-23.0) on CT, and 20.7 mm (19.3-22.3) on angiography. The distal neck diameter was 23.0mm (22.0-24.0) on CT, and 22.3mm (20.3-24.6) on angiography, while the neck length was only slightly greater on angiography [23.0mm (17.5-28.4)] relative to CT [23.0mm (20.0-28.0)]. The stent-grafts deployed were oversized by 26.8% (+/- 14.8%) relative to the CT measurements, and 33.7% (+/- 15.6%) relative to angiographic measurements. Good correlation was found for all three measurements between CT and angiography. CONCLUSIONS: Angiography alone is inadequate for endovascular aneurysm repair. Although it has timesaving potential, the accuracy achieved is not sufficient to use alone.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Stents , Anciano , Angiografía , Intervalos de Confianza , Urgencias Médicas , Femenino , Humanos , Cuidados Intraoperatorios , Masculino , Cuidados Preoperatorios , Estudios Prospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X
10.
J Endovasc Ther ; 14(4): 528-35, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17696628

RESUMEN

PURPOSE: To correlate the Hardman prognostic index with perioperative mortality in patients undergoing open and endovascular repair of ruptured abdominal aortic aneurysm (rAAA). METHODS: Over a 5-year period, 126 patients (109 men; mean age 74 years, range 51-91) underwent open (n=74) or endovascular (n=52) repair of rAAA in a single unit. Five Hardman factors (age>76 years, history of loss of consciousness, ECG evidence of ischemia, hemoglobin<9.0 g/dL, and serum creatinine>0.19 mmol/L) were assessed, and their association with in-hospital or 30-day mortality was evaluated retrospectively by chi-square or logistic regression analysis. RESULTS: The mortality for open repair was 51.4% (38/74) in comparison to 32.7% (17/52) for the endovascular group (p=0.05). On multivariate analysis, loss of consciousness (p=0.03, OR 2.9, 95% CI 1.1 to 7.5) was the only significant predictor of mortality in both groups. The mortality rates for open repair patients with Hardman scores<2 were 43.5% (20/46) in comparison to 22.9% (8/35) for the endovascular group (p=0.06), whereas mortality rates for patients with scores>or=2 were 64.3% (18/28) and 52.9% (9/17) for the respective groups (p=0.54). CONCLUSION: The Hardman index correlates well with mortality in both the open and endovascular groups. Those with a score<2 have a trend toward better survival following endovascular repair compared to open repair, while this benefit is not obvious in patients with a score>or=2.


Asunto(s)
Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/mortalidad , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/mortalidad , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/métodos , Bases de Datos como Asunto , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Reproducibilidad de los Resultados , Proyectos de Investigación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
11.
J Vasc Surg ; 44(3): 467-71, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16950418

RESUMEN

OBJECTIVE: The use of endovascular aneurysm repair (EVAR) for ruptured abdominal aortic aneurysm (AAA) has been restricted to a small number of specialized units on a selected group of patients. The aim of this study is to assess if the overall mortality in these patients with ruptured AAA may be reduced in a unit where all patients with ruptured AAA are considered first for EVAR. METHODS: During a 24-month period beginning in July 2002, 51 patients admitted with ruptured AAA were considered for EVAR as the treatment of choice and comprised the study group. EVAR was performed in 17 patients. Open repair was performed in 34 patients: 13 patients had hemodynamic instability and 16 patients had an unsuitable aortic neck anatomy. The study group was compared with a historical control group of 41 patients with ruptured AAA who were treated by open repair from July 2000 to June 2002. RESULTS: Mortality rate was 39% in the study group compared with 59% in the control group (P = .065). The duration of stay in the intensive care unit was significantly lower in the study group than in the control group (P = .01), although the total in-hospital stay was similar (17 days vs 14 days, P = .83). Within the study group, EVAR patients had a mortality rate of 24% compared with 47% in the open group (P = .14). CONCLUSION: Although the number of patients was small, offering EVAR to as many patients as possible with ruptured AAA has resulted in a 20% reduction in mortality, albeit statistically insignificant. However, it is in the unstable patients that EVAR will need to improve survival before it may be hailed to supersede the conventional approach.


Asunto(s)
Aneurisma Roto/mortalidad , Aneurisma Roto/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/cirugía , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular , Femenino , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Selección de Paciente , Complicaciones Posoperatorias/epidemiología , Tomografía Computarizada por Rayos X , Procedimientos Quirúrgicos Vasculares
12.
J Vasc Surg ; 44(2): 244-9, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16890848

RESUMEN

BACKGROUND: Endovascular repair of abdominal aortic aneurysm (AAA) is increasingly used. We evaluated if a difference exists in the rate of change of the aortic neck diameter between non-ruptured and ruptured AAAs after endovascular aneurysm repair (EVAR). METHODS: Details of patients undergoing elective (group I) and emergency (group II) EVAR using Talent stents between October 1999 and September 2005 were reviewed. Top neck diameters were prospectively recorded on the hospital database from computed tomography scans preoperatively and at 1, 3, 12, and 24 months postoperatively. The aortic neck diameter rate of change was calculated for each group. RESULTS: Endovascular repair was performed on 110 elective and 41 emergency patients, of which 100 (80 male) elective and 29 (26 male) emergency patients were included in this analysis. Mean age was similar in each group. Stents were oversized by 20.9% +/- 13.6% in group I and by 24.7% +/- 16.3% in group II (P = .37). The preoperative mean proximal aortic neck was larger in group II (25.0 +/- 3.3 mm vs 23.5 +/- 2.8 mm; P = .029). The growth rate of the top neck diameter was significantly greater at 12 months (1.48 +/- 2.4 mm/year vs 3.89 +/- 6.24 mm/year; P = .04) and 24 months (.99 +/- 1.1 mm/year vs 2.61 +/- 3.3 mm/year; P = .04) in group II than in group I. A decreasing sac size was found in 68.2% of patients whose neck dilated. The complication rate was similar in each group. CONCLUSION: Aneurysm necks in patients with ruptured aneurysms are larger and dilate at a greater rate than those with nonruptured aneurysms. The accelerated rate of expansion in some patients must be borne in mind during follow-up and in secondary endovascular interventions and conversion to open surgery.


Asunto(s)
Angioplastia , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Stents , Anciano , Angioplastia/métodos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/terapia , Rotura de la Aorta/cirugía , Rotura de la Aorta/terapia , Aortografía , Femenino , Humanos , Masculino , Sistemas de Registros Médicos Computarizados , Falla de Prótesis , Estudios Retrospectivos , Tomografía Computarizada Espiral , Resultado del Tratamiento
13.
Scand J Urol Nephrol ; 38(2): 179-81, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15204414

RESUMEN

The term varicocele describes a dilated, tortuous and elongated pampiniform plexus of veins, which is well known in relation to the spermatic cord. Recently varicocele has also been observed inside the testis, and this new entity is known as intra-testicular varicocele. We present a case of intra-testicular varicocele presenting as acute scrotum and discuss the management issues.


Asunto(s)
Escroto , Varicocele/diagnóstico , Enfermedad Aguda , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Enfermedades Testiculares/diagnóstico , Varicocele/complicaciones
14.
J Endovasc Ther ; 11(3): 319-22, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15174913

RESUMEN

PURPOSE: To compare the changes in aneurysm size following endovascular aneurysm repair (EVAR) for ruptured versus elective abdominal aortic aneurysms (AAA). METHODS: Aneurysm sac diameter was measured from computed tomographic (CT) scans in 14 hemodynamically stable patients (14 men; mean age 74+/-7 years, range 60 to 83) prior to emergent stent-graft repair for ruptured AAA. The aneurysm diameter change was followed postprocedurally with serial CT and the outcomes compared to 74 AAA patients (58 men; mean age 74+/-7 years, range 56 to 87) having elective EVAR in the same time period. The mean rate of sac decrease (mm/month) was calculated for each group. RESULTS: There were 3 postoperative deaths in the ruptured AAA cohort, leaving 11 patients available for follow-up analysis (mean 16 months, range 2-49). Eight (73%) patients with ruptured AAA demonstrated significantly decreased (>5 mm) aneurysm diameters compared with 32 (43%) elective cases (p=0.07) followed a mean 20 months (range 3-51). The mean rate of sac diameter decrease was 1.50+/-1.03 mm/month in the rupture group versus 0.73+/-0.86 mm/month in the elective group (p=0.04). CONCLUSIONS: This study suggests that ruptured AAAs treated with stent-graft experience sac regression at a higher rate compared with electively treated AAA. The reasons for these findings remain unclear.


Asunto(s)
Angioplastia de Balón/instrumentación , Aneurisma de la Aorta Abdominal/terapia , Rotura de la Aorta/terapia , Prótesis Vascular , Stents , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Aortografía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA