Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Diabet Med ; 34(6): 804-812, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28196274

RESUMEN

AIM: Higher haemoglobin levels and differences in glucose metabolism have been reported among high-altitude residents, which may influence the diagnostic performance of HbA1c . This study explores the relationship between HbA1c and fasting plasma glucose (FPG) in populations living at sea level and at an altitude of > 3000 m. METHODS: Data from 3613 Peruvian adults without a known diagnosis of diabetes from sea-level and high-altitude settings were evaluated. Linear, quadratic and cubic regression models were performed adjusting for potential confounders. Receiver operating characteristic (ROC) curves were constructed and concordance between HbA1c and FPG was assessed using a Kappa index. RESULTS: At sea level and high altitude, means were 13.5 and 16.7 g/dl (P > 0.05) for haemoglobin level; 41 and 40 mmol/mol (5.9% and 5.8%; P < 0.01) for HbA1c ; and 5.8 and 5.1 mmol/l (105 and 91.3 mg/dl; P < 0.001) for FPG, respectively. The adjusted relationship between HbA1c and FPG was quadratic at sea level and linear at high altitude. Adjusted models showed that, to predict an HbA1c value of 48 mmol/mol (6.5%), the corresponding mean FPG values at sea level and high altitude were 6.6 and 14.8 mmol/l (120 and 266 mg/dl), respectively. An HbA1c cut-off of 48 mmol/mol (6.5%) had a sensitivity for high FPG of 87.3% (95% confidence interval (95% CI) 76.5 to 94.4) at sea level and 40.9% (95% CI 20.7 to 63.6) at high altitude. CONCLUSION: The relationship between HbA1c and FPG is less clear at high altitude than at sea level. Caution is warranted when using HbA1c to diagnose diabetes mellitus in this setting.


Asunto(s)
Altitud , Glucemia/análisis , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/diagnóstico , Ayuno/sangre , Hemoglobina Glucada/análisis , Adulto , Anciano , Femenino , Geografía , Prueba de Tolerancia a la Glucosa , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Perú
2.
Diabet Med ; 32(11): 1470-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25761508

RESUMEN

AIM: To determine if changes in pupillary response are useful as a screening tool for diabetes and to assess whether pupillometry is associated with cardiac autonomic neuropathy. METHODS: We conducted a cross-sectional study with participants drawn from two settings: a hospital and a community site. At the community site, individuals with newly diagnosed diabetes as well as a random sample of control individuals without diabetes, confirmed by oral glucose tolerance test, were selected. Participants underwent an LED light stimulus test and eight pupillometry variables were measured. Outcomes were diabetes, defined by oral glucose tolerance test, and cardiac autonomic dysfunction, determined by a positive readout on two of four diagnostic tests: heart rate response to the Valsalva manoeuvre; orthostatic hypotension; 30:15 ratio; and expiration-to-inspiration ratio. The area under the curve, best threshold, sensitivity and specificity of each pupillometry variable was calculated. RESULTS: Data from 384 people, 213 with diabetes, were analysed. The mean (±sd) age of the people with diabetes was 58.6 (±8.2) years and in the control subjects it was 56.1 (±8.6) years. When comparing individuals with and without diabetes, the amplitude of the pupil reaction had the highest area under the curve [0.69 (sensitivity: 78%; specificity: 55%)]. Cardiac autonomic neuropathy was present in 51 of the 138 people evaluated (37.0%; 95% CI 28.8-45.1). To diagnose cardiac autonomic neuropathy, two pupillometry variables had the highest area under the curve: baseline pupil radius [area under the curve: 0.71 (sensitivity: 51%; specificity: 84%)], and amplitude of the pupil reaction [area under the curve: 0.70 (sensitivity: 82%; specificity: 55%)]. CONCLUSIONS: Pupillometry is an inexpensive technique to screen for diabetes and cardiac autonomic neuropathy, but it does not have sufficient accuracy for clinical use as a screening tool.


Asunto(s)
Enfermedades del Sistema Nervioso Autónomo/diagnóstico , Diabetes Mellitus Tipo 2/complicaciones , Cardiomiopatías Diabéticas/diagnóstico , Neuropatías Diabéticas/diagnóstico , Tamizaje Masivo , Pupila/efectos de la radiación , Adulto , Anciano , Enfermedades del Sistema Nervioso Autónomo/complicaciones , Enfermedades del Sistema Nervioso Autónomo/patología , Enfermedades del Sistema Nervioso Autónomo/fisiopatología , Estudios Transversales , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/patología , Diabetes Mellitus Tipo 2/fisiopatología , Retinopatía Diabética/diagnóstico , Diagnóstico Precoz , Femenino , Humanos , Luz , Masculino , Persona de Mediana Edad , Perú , Reflejo Pupilar/efectos de la radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Rev Gastroenterol Peru ; 27(3): 295-302, 2007.
Artículo en Español | MEDLINE | ID: mdl-17934544

RESUMEN

Three obese patients underwent sleeve gastrectomy. They developed gastric dehiscence with generalized peritonitis, sepsis and shock, being operated as total gastrectomy of the remanent stomach with Roux in Y esophago-jejunostomy reconstruction as a last chance of life saving procedure.


Asunto(s)
Gastrectomía/métodos , Derivación Gástrica , Sepsis/cirugía , Dehiscencia de la Herida Operatoria/cirugía , Adulto , Femenino , Derivación Gástrica/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Sepsis/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA