Int J Prosthodont ; (3): 319-326, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38905586

RESUMEN

PURPOSE: To analyze the effect of disinfectants on the roughness and mechanical properties of CAD/ CAM polymethylmethacrylate (PMMA) dentures. MATERIALS AND METHODS: Two groups of denture base resins were tested-heat-polymerized and milled blocks. For each resin, 120 specimens were produced for flexural strength (FS) and flexural modulus (FM) analyses (total: 240 specimens), and 40 were produced for microhardness and surface roughness evaluations (total: 80 specimens). They were categorized into the following groups based on immersion: control (deionized water); H1 (1% sodium hypochlorite); H05 (0.5% sodium hypochlorite); and C2 (2% chlorhexidine) groups. The immersion periods were 0 (T0), 130 (T1), and 260 (T2) cycles. Statistical analyses were performed for flexural properties using threeway ANOVA. Microhardness (KHN) and surface roughness (Ra) were analyzed using repeated-measures ANOVA. A significance level of 5% was set. RESULTS: CAD/CAM PMMA showed higher FS (P = .001) and FM (P < .001) than conventional PMMA. The KHN value was superior to the conventional PMMA (P < .001). The chemical solution affected the surface roughness of both resins (P = .007). The CAD/ CAM PMMA block showed increased Ra values when H1 was used. Cycling separately increased the FS of conventional PMMA (T1 vs baseline; P < .05). However, the FM of CAD/CAM PMMA was higher (T1 and T2 vs baseline; P < .05). The time factor increased the microhardness of both resins (T2 vs baseline; P < .05). CONCLUSIONS: The CAD/CAM resin showed higher values compared to conventional PMMA in all tests, regardless of the chemical solution used; however, the values obtained for both resins were clinically acceptable.


Asunto(s)
Diseño Asistido por Computadora , Resistencia Flexional , Ensayo de Materiales , Polimetil Metacrilato , Propiedades de Superficie , Polimetil Metacrilato/química , Dureza , Bases para Dentadura , Desinfección/métodos , Clorhexidina/química , Hipoclorito de Sodio/química
2.
J Appl Oral Sci ; 31: e20230054, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37646715

RESUMEN

Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing (CAD-CAM) bars. OBJECTIVE: To evaluate the performance of IODs involving CAD-CAM bars. METHODOLOGY: A comprehensive search of studies published until May 2023 was conducted in many databases, including PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The population, intervention, comparison, outcome (PICO) question was: "How do IODs retained by bars fabricated by CAD-CAM technology perform in daily clinical practice?" The meta-analysis included clinical studies based on effect size and a two-tailed null test with a 95% confidence interval (CI). RESULTS: Ten studies were included in the meta-analysis. Among them, nine reported a 100% implant survival rate for all CAD-CAM milled bars. Complications were reported in two studies with CAD/CAM-milled titanium bars, and one study reported more fractures in soldered gold bars used in maxillary rehabilitation. However, no fractures were observed in IODs retained by PEEK and zirconia bars. According to six studies, biological complications, including peri-implantitis, were minimal in the BioHPP and PEEK bar groups, while no cases were reported in the titanium or zirconia bar groups. CAD-CAM-milled zirconia bars had higher plaque and bleeding indices compared with titanium bars, as evidenced by findings from five studies. All four studies that evaluated Oral Health Impact Profile (OHIP) scores showed a positive effect of IODs retained by CAD-CAM milled titanium bars on quality of life. Patient satisfaction and acceptance by prosthodontists were significantly high, according to the results of five studies. CONCLUSION: Overdentures retained with CAD-CAM milled titanium bars show great potential for use in daily clinical practice. Moreover, patient and practitioner satisfaction was very high when this method was used.


Asunto(s)
Prótesis de Recubrimiento , Calidad de Vida , Humanos , Titanio , Diseño Asistido por Computadora
3.
Materials (Basel) ; 14(7)2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33810381

RESUMEN

The characteristics of the denture base surface, in combination with the oral environment, promote the colonization and development of Candida albicans biofilm, which is the main cause of denture stomatitis. This study evaluated the effectiveness of fibrin biopolymer with digluconate chlorhexidine or Punica granatum alcoholic extract to prevent C. albicans biofilm. Conventional heat polymerized and pre-polymerized poly(methyl methacrylate) (PMMA) circular specimens (10 × 2 mm) were fabricated (n = 504) and randomly divided into groups: no treatment (control-CT), fibrin biopolymer coating (FB), fibrin biopolymer with P. granatum (FBPg), or digluconate of chlorhexidine (FBCh) coating. The specimens were inoculated with C. albicans SC5314 (1 × 107 cells/mL) and incubated for 24, 48, and 72 h. Crystal violet and colony-forming unit assays were used to quantify the total biofilm biomass and biofilm-living cells. A qualitative analysis was performed using confocal laser scanning microscopy. Data obtained are expressed as means and standard deviations and were statistically analyzed using a three-way analysis of variance (α = 0.05). The FBPg and FBCh groups inhibited the growth of C. albicans biofilm in both PMMA materials analyzed, with FBCh performing better in all periods evaluated (p < 0.0001). The colony forming unit (CFU) assay showed that the FB group favored the C. albicans biofilm growth at 24 h and 48 h (p < 0.0001), with no differences with CT group at 72 h (p = 0.790). All groups showed an enhancement in biofilm development up to 72 h (p < 0.0001), except the FBCh group (p = 0.100). No statistical differences were found between the PMMA base materials (p > 0.050), except in the FB group (p < 0.0001). Fibrin biopolymer, albeit a scaffold for the growth of C. albicans, when combined with chlorhexidine digluconate or P. granatum, demonstrated excellent performance as a drug delivery system, preventing and controlling the formation of denture biofilm.

4.
J. appl. oral sci ; J. appl. oral sci;31: e20230054, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1506566

RESUMEN

Abstract Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing (CAD-CAM) bars. Objective: To evaluate the performance of IODs involving CAD-CAM bars. Methodology: A comprehensive search of studies published until May 2023 was conducted in many databases, including PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The population, intervention, comparison, outcome (PICO) question was: "How do IODs retained by bars fabricated by CAD-CAM technology perform in daily clinical practice?" The meta-analysis included clinical studies based on effect size and a two-tailed null test with a 95% confidence interval (CI). Results: Ten studies were included in the meta-analysis. Among them, nine reported a 100% implant survival rate for all CAD-CAM milled bars. Complications were reported in two studies with CAD/CAM-milled titanium bars, and one study reported more fractures in soldered gold bars used in maxillary rehabilitation. However, no fractures were observed in IODs retained by PEEK and zirconia bars. According to six studies, biological complications, including peri-implantitis, were minimal in the BioHPP and PEEK bar groups, while no cases were reported in the titanium or zirconia bar groups. CAD-CAM-milled zirconia bars had higher plaque and bleeding indices compared with titanium bars, as evidenced by findings from five studies. All four studies that evaluated Oral Health Impact Profile (OHIP) scores showed a positive effect of IODs retained by CAD-CAM milled titanium bars on quality of life. Patient satisfaction and acceptance by prosthodontists were significantly high, according to the results of five studies. Conclusion: Overdentures retained with CAD-CAM milled titanium bars show great potential for use in daily clinical practice. Moreover, patient and practitioner satisfaction was very high when this method was used.