RESUMEN
BACKGROUND: MRI with xenon-129 gas (Xe MRI) can assess airflow obstruction and heterogeneity in lung diseases. Specifically, Xe MRI may represent a sensitive modality for future therapeutic trials of cystic fibrosis (CF) therapies. The reproducibility of Xe MRI has not yet been assessed in the context of a multi-site study. PURPOSE: To determine the same-day repeatability and 28-day reproducibility of Xe MRI in children with CF. STUDY TYPE: Four-center prospective, longitudinal. POPULATION: Thirty-eight children (18 females, 47%), median interquartile range (IQR) age 12 (9-14) years old, with mild CF (forced expiratory volume in 1 second (FEV1) ≥85% predicted). FIELD STRENGTH/SEQUENCE: 3-T, two-dimensional (2D) gradient-echo (GRE) sequence. ASSESSMENT: Xe MRI, FEV1, and nitrogen multiple-breath wash-out for lung-clearance index (LCI2.5) were performed. To assess same-day reproducibility, Xe MRI was performed twice within the first visit, and procedures were repeated at 28 days. Xe hypoventilation was quantified using ventilation-defect percentage (VDP) and reader-defect volume (RDV). For VDP, hypoventilated voxels from segmented images were identified using a threshold of <60% mean whole-lung signal and expressed as a percentage of the lung volume. For RDV, hypoventilation was identified by two trained readers and expressed as a percentage. STATISTICAL TESTS: Inter-site comparisons were conducted using Kruskal-Wallis nonparametric tests with Dunn's multiple-comparisons tests. Differences for individuals were assessed using Wilcoxon matched-pairs tests. Bland-Altman tests were used to evaluate same-day repeatability, 28-day reproducibility, and inter-reader agreement. A P-value ≤0.05 was considered significant. RESULTS: Median FEV1 %-predicted was 96.8% (86%-106%), and median LCI2.5 was 6.6 (6.3-7.4). Xe MRI had high same-day reproducibility (mean VDP difference 0.12%, 95% limits of agreement [-3.2, 3.4]; mean RDV difference 0.42% [-2.5, 3.3]). At 28 days, 26/31 participants (84%) fell within the same-day 95% limits of agreement. DATA CONCLUSION: Xe MRI may offer excellent same-day and short-term reproducibility. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.
RESUMEN
PURPOSE: To develop and test compressed sensing-based multiframe 3D MRI of grid-tagged hyperpolarized gas in the lung. THEORY AND METHODS: Applying grid-tagging RF pulses to inhaled hyperpolarized gas results in images in which signal intensity is predictably and sparsely distributed. In the present work, this phenomenon was used to produce a sampling pattern in which k-space is undersampled by a factor of approximately seven, yet regions of high k-space energy remain densely sampled. Three healthy subjects received multiframe 3D 3 He tagging MRI using this undersampling method. Images were collected during a single exhalation at eight timepoints spanning the breathing cycle from end-of-inhalation to end-of-exhalation. Grid-tagged images were used to generate 3D displacement maps of the lung during exhalation, and time-resolved maps of principal strains and fractional volume change were generated from these displacement maps using finite-element analysis. RESULTS: Tags remained clearly resolvable for 4-6 timepoints (5-8 s) in each subject. Displacement maps revealed noteworthy temporal and spatial nonlinearities in lung motion during exhalation. Compressive normal strains occurred along all three principal directions but were primarily oriented in the head-foot direction. Fractional volume changes displayed clear bilateral symmetry, but with the lower lobes displaying slightly higher change than the upper lobes in 2 of the 3 subjects. CONCLUSION: We developed a compressed sensing-based method for multiframe 3D MRI of grid-tagged hyperpolarized gas in the lung during exhalation. This method successfully overcomes previous challenges for 3D dynamic grid-tagging, allowing time-resolved biomechanical readouts of lung function to be generated.
Asunto(s)
Compresión de Datos , Pulmón , Masculino , Humanos , Pulmón/diagnóstico por imagen , Respiración , Imagen por Resonancia Magnética/métodosRESUMEN
To investigate whether hyperpolarised xenon-129 MRI (HXeMRI) enables regional and physiological resolution of diffusing capacity limitations in chronic obstructive pulmonary disease (COPD), we evaluated 34 COPD subjects and 11 healthy volunteers. We report significant correlations between airflow abnormality quantified by HXeMRI and per cent predicted forced expiratory volume in 1 s; HXeMRI gas transfer capacity to red blood cells and carbon monoxide diffusion capacity (%DLCO); and HXeMRI gas transfer capacity to interstitium and per cent emphysema quantified by multidetector chest CT. We further demonstrate the capability of HXeMRI to distinguish varying pathology underlying COPD in subjects with low %DLCO and minimal emphysema.
Asunto(s)
Imagen por Resonancia Magnética/métodos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Intercambio Gaseoso Pulmonar , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Isótopos de XenónRESUMEN
PURPOSE: To characterize the differences between histogram-based and image-based algorithms for segmentation of hyperpolarized gas lung images. METHODS: Four previously published histogram-based segmentation algorithms (ie, linear binning, hierarchical k-means, fuzzy spatial c-means, and a Gaussian mixture model with a Markov random field prior) and an image-based convolutional neural network were used to segment 2 simulated data sets derived from a public (n = 29 subjects) and a retrospective collection (n = 51 subjects) of hyperpolarized 129Xe gas lung images transformed by common MRI artifacts (noise and nonlinear intensity distortion). The resulting ventilation-based segmentations were used to assess algorithmic performance and characterize optimization domain differences in terms of measurement bias and precision. RESULTS: Although facilitating computational processing and providing discriminating clinically relevant measures of interest, histogram-based segmentation methods discard important contextual spatial information and are consequently less robust in terms of measurement precision in the presence of common MRI artifacts relative to the image-based convolutional neural network. CONCLUSIONS: Direct optimization within the image domain using convolutional neural networks leverages spatial information, which mitigates problematic issues associated with histogram-based approaches and suggests a preferred future research direction. Further, the entire processing and evaluation framework, including the newly reported deep learning functionality, is available as open source through the well-known Advanced Normalization Tools ecosystem.
Asunto(s)
Semántica , Isótopos de Xenón , Algoritmos , Ecosistema , Humanos , Procesamiento de Imagen Asistido por Computador , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios RetrospectivosRESUMEN
Hyperpolarized (HP) 129 Xe MRI uniquely images pulmonary ventilation, gas exchange, and terminal airway morphology rapidly and safely, providing novel information not possible using conventional imaging modalities or pulmonary function tests. As such, there is mounting interest in expanding the use of biomarkers derived from HP 129 Xe MRI as outcome measures in multi-site clinical trials across a range of pulmonary disorders. Until recently, HP 129 Xe MRI techniques have been developed largely independently at a limited number of academic centers, without harmonizing acquisition strategies. To promote uniformity and adoption of HP 129 Xe MRI more widely in translational research, multi-site trials, and ultimately clinical practice, this position paper from the 129 Xe MRI Clinical Trials Consortium (https://cpir.cchmc.org/XeMRICTC) recommends standard protocols to harmonize methods for image acquisition in HP 129 Xe MRI. Recommendations are described for the most common HP gas MRI techniques-calibration, ventilation, alveolar-airspace size, and gas exchange-across MRI scanner manufacturers most used for this application. Moreover, recommendations are described for 129 Xe dose volumes and breath-hold standardization to further foster consistency of imaging studies. The intention is that sites with HP 129 Xe MRI capabilities can readily implement these methods to obtain consistent high-quality images that provide regional insight into lung structure and function. While this document represents consensus at a snapshot in time, a roadmap for technical developments is provided that will further increase image quality and efficiency. These standardized dosing and imaging protocols will facilitate the wider adoption of HP 129 Xe MRI for multi-site pulmonary research.
Asunto(s)
Pulmón , Isótopos de Xenón , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Multicéntricos como Asunto , Ventilación Pulmonar , RespiraciónRESUMEN
Background Apparent diffusion coefficient (ADC) maps of inhaled hyperpolarized gases have shown promise in the characterization of emphysema in patients with chronic obstructive pulmonary disease (COPD), yet an easily interpreted quantitative metric beyond mean and standard deviation has not been established. Purpose To introduce a quantitative framework with which to characterize emphysema burden based on hyperpolarized helium 3 (3He) and xenon 129 (129Xe) ADC maps and compare its diagnostic performance with CT-based emphysema metrics and pulmonary function tests (PFTs). Materials and Methods Twenty-seven patients with mild, moderate, or severe COPD and 13 age-matched healthy control subjects participated in this retrospective study. Participants underwent CT and multiple b value diffusion-weighted 3He and 129Xe MRI examinations and standard PFTs between August 2014 and November 2017. ADC-based emphysema index was computed separately for each gas and b value as the fraction of lung voxels with ADC values greater than in the healthy group 99th percentile. The resulting values were compared with quantitative CT results (relative lung area <-950 HU) as the reference standard. Diagnostic performance metrics included area under the receiver operating characteristic curve (AUC). Spearman rank correlations and Wilcoxon rank sum tests were performed between ADC-, CT-, and PFT-based metrics, and intraclass correlation was performed between repeated measurements. Results Thirty-six participants were evaluated (mean age, 60 years ± 6 [standard deviation]; 20 women). ADC-based emphysema index was highly repeatable (intraclass correlation coefficient > 0.99) and strongly correlated with quantitative CT (r = 0.86, P < .001 for 3He; r = 0.85, P < .001 for 129Xe) with high AUC (≥0.93; 95% confidence interval [CI]: 0.85, 1.00). ADC emphysema indices were also correlated with percentage of predicted diffusing capacity of lung for carbon monoxide (r = -0.81, P < .001 for 3He; r = -0.80, P < .001 for 129Xe) and percentage of predicted residual lung volume divided by total lung capacity (r = 0.65, P < .001 for 3He; r = 0.61, P < .001 for 129Xe). Conclusion Emphysema index based on hyperpolarized helium 3 or xenon 129 diffusion MRI provides a repeatable measure of emphysema burden, independent of gas or b value, with similar diagnostic performance as quantitative CT or pulmonary function metrics. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Schiebler and Fain in this issue.
Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Enfisema Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Estudios de Casos y Controles , Femenino , Helio , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Isótopos de XenónRESUMEN
Drying is one of the treatment techniques used for the dual purpose of safe disposal and energy recovery of faecal sludge (FS). Limited data are available regarding the FS drying process. In this paper the drying properties of FS were investigated using samples from ventilated improved pit (VIP) latrines and urine diversion dry toilets (UDDT) and an anaerobic baffle reactor (ABR) from a decentralized wastewater treatment systems. Moisture content, total solids content, volatile solids content, water activity, coupled thermogravimetry & differential thermal analysis (TGA-DTA) and calorific value tests were used to characterize FS drying. Drying kinetics and water activity measured at different moisture content during drying (100 °C) were similar for the samples from different on-site sanitation facilities. Experimental heat of drying results revealed that FS requires two to three times that of the latent heat of vaporization of water for drying. Drying temperature was more significant than the sludge source in determining the final volatile solids content of the dried samples. This was reinforced by the dynamic TGA that showed considerable thermal degradation (2-11% dry solid mass) near 200 °C. Below 200 C, the calorific value of the dried samples exhibited no significant difference. The average calorific values of VIP, UDDT and ABR samples at 100 °C were 14.78, 15.70, 17.26 MJ/kg dry solid, respectively. This suggests that the fuel value of FS from the aforementioned sanitation facilities will not be significantly affected by drying temperature below 200 °C. Based on this study, the most suitable temperature for drying of FS for a solid fuel application was found to be 150 °C.
Asunto(s)
Saneamiento , Aguas del Alcantarillado , Desecación , Heces , Aguas ResidualesRESUMEN
BACKGROUND/AIMS: "Whole-brain" infusions have emerged as a potential need with the promise of disease-modifying therapies for neurodegenerative diseases. In addition, several current clinical trials in brain cancer utilize direct delivery of drugs that are required to fill large volumes. Such requirements may not be well served by conventional single port catheters with their "point source" of delivery. Our aim is to examine infusions into large volumes of heterogeneous tissue, aiming for uniformity of distribution. METHODS: A porous catheter (porous brain infusion catheter, PBIC), designed by Twin Star TDS LLC, for brain infusions was developed for this study and compared with another convection-enhanced delivery catheter (SmartFlowTM NGS-NC-03 from MRI Interventions, a step end-port catheter, SEPC) in current use in clinical trials. The studies were in vivo in porcine brain. A total of 8 pigs were used: the size of the pig brain limited the porous length to 15 mm. The placements of the tips of the two catheters were chosen to be the same (at the respective brain hemispheres). RESULTS: The PBIC and SEPC both performed comparably and well, with the PBIC having some advantage in effecting larger distributions: p â¼ 0.045, with 5 infusions from each. CONCLUSIONS: Given the performance of the PBIC, it would be highly appropriate to use the device for therapeutic infusions in human clinical trials to assess its capability for large-volume infusions.
Asunto(s)
Encéfalo/efectos de los fármacos , Catéteres , Sistemas de Liberación de Medicamentos/instrumentación , Animales , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Imagen por Resonancia Magnética , PorcinosRESUMEN
PURPOSE: To evaluate T2 , T2*, and signal-to-noise ratio (SNR) for hyperpolarized helium-3 (3 He) MRI of the human lung at three magnetic field strengths ranging from 0.43T to 1.5T. METHODS: Sixteen healthy volunteers were imaged using a commercial whole body scanner at 0.43T, 0.79T, and 1.5T. Whole-lung T2 values were calculated from a Carr-Purcell-Meiboom-Gill spin-echo-train acquisition. T2* maps and SNR were determined from dual-echo and single-echo gradient-echo images, respectively. Mean whole-lung SNR values were normalized by ventilated lung volume and administered 3 He dose. RESULTS: As expected, T2 and T2* values demonstrated a significant inverse relationship to field strength. Hyperpolarized 3 He images acquired at all three field strengths had comparable SNR values and thus appeared visually very similar. Nonetheless, the relatively small SNR differences among field strengths were statistically significant. CONCLUSIONS: Hyperpolarized 3 He images of the human lung with similar image quality were obtained at three field strengths ranging from 0.43T and 1.5T. The decrease in susceptibility effects at lower fields that are reflected in longer T2 and T2* values may be advantageous for optimizing pulse sequences inherently sensitive to such effects. The three-fold increase in T2* at lower field strength would allow lower receiver bandwidths, providing a concomitant decrease in noise and relative increase in SNR. Magn Reson Med 78:1458-1463, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Asunto(s)
Helio/química , Procesamiento de Imagen Asistido por Computador/métodos , Isótopos/química , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Administración por Inhalación , Adulto , Helio/administración & dosificación , Humanos , Isótopos/administración & dosificación , Campos Magnéticos , Relación Señal-Ruido , Adulto JovenRESUMEN
There are many shortcomings of current animal models as surrogates of hepatocellular carcinoma that handicap preclinical testing of embolization agents. The present study explores the feasibility of using the woodchuck (Marmota monax) as an animal model for the testing of novel embolization agents. Four woodchucks underwent magnetic resonance imaging, angiography, and left lobar hepatic artery particle embolization. Percutaneous access, arteriography, and lobar embolization were successful in all animals, with angiographic stasis obtained in the target vessel with minimal reflux of embolic material. These results support the feasibility of the woodchuck as an animal model for preclinical testing of embolization agents.
Asunto(s)
Carcinoma Hepatocelular/terapia , Modelos Animales de Enfermedad , Embolización Terapéutica/métodos , Neoplasias Hepáticas/terapia , Marmota , Angiografía de Substracción Digital , Animales , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética , Ultrasonografía IntervencionalRESUMEN
PURPOSE: To investigate whether chemical shift saturation recovery (CSSR) MR spectroscopy with hyperpolarized xenon-129 is sensitive to the pulsatile nature of pulmonary blood flow during the cardiac cycle. METHODS: A CSSR pulse sequence typically uses radiofrequency (RF) pulses to saturate the magnetization of xenon-129 dissolved in lung tissue followed, after a variable delay time, by an RF excitation and subsequent acquisition of a free-induction decay. Thereby it is possible to monitor the uptake of xenon-129 by lung tissue and extract physiological parameters of pulmonary gas exchange. In the current studies, the delay time was instead held at a constant value, which permitted observation of xenon-129 gas uptake as a function of breath-hold time. CSSR studies were performed in 13 subjects (10 healthy, 2 chronic obstructive pulmonary disease [COPD], 1 second-hand smoke exposure), holding their breath at total lung capacity. RESULTS: The areas of the tissue/plasma and the red-blood-cell peaks in healthy subjects varied by an average of 1.7±0.7% and 15.1±3.8%, respectively, during the cardiac cycle. In 2 subjects with COPD these peak pulsations were not detectable during at least part of the measurement period. CONCLUSION: CSSR spectroscopy is sufficiently sensitive to detect oscillations in the xenon-129 gas-uptake rate associated with the cardiac cycle.
Asunto(s)
Capilares/diagnóstico por imagen , Pulmón/irrigación sanguínea , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón/química , Adulto , Femenino , Humanos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Isótopos de Xenón/análisis , Adulto JovenRESUMEN
PURPOSE: To develop and validate a method for acquiring helium-3 ((3) He) and proton ((1) H) three-dimensional (3D) image sets of the human lung with isotropic spatial resolution within a 10-s breath-hold by using compressed sensing (CS) acceleration, and to assess the fidelity of undersampled images compared with fully sampled images. METHODS: The undersampling scheme for CS acceleration was optimized and tested using (3) He ventilation data. Rapid 3D acquisition of both (3) He and (1) H data during one breath-hold was then implemented, based on a balanced steady-state free-precession pulse sequence, by random undersampling of k-space with reconstruction by means of minimizing the L1 norm and total variance. CS-reconstruction fidelity was evaluated quantitatively by comparing fully sampled and retrospectively undersampled image sets. RESULTS: Helium-3 and (1) H 3D image sets of the lung with isotropic 3.9-mm resolution were acquired during a single breath-hold in 12 s and 8 s using acceleration factors of 2 and 3, respectively. Comparison of fully sampled and retrospectively undersampled (3) He and (1) H images yielded mean absolute errors <10% and structural similarity indices >0.9. CONCLUSION: By randomly undersampling k-space and using CS reconstruction, high-quality (3) He and (1) H 3D image sets with isotropic 3.9-mm resolution can be acquired within an 8-s breath-hold.
Asunto(s)
Contencion de la Respiración , Imagenología Tridimensional/métodos , Pulmón/fisiología , Imagen por Resonancia Magnética/métodos , Protones , Adulto , Fibrosis Quística , Femenino , Helio/administración & dosificación , Helio/química , Humanos , Masculino , Adulto JovenRESUMEN
PURPOSE: To evaluate regional anisotropy of lung-airspace orientation by assessing the dependence of helium-3 ((3) He) apparent diffusion coefficient (ADC) values on the direction of diffusion sensitization at two field strengths. MATERIALS AND METHODS: Hyperpolarized (3) He diffusion-weighted magnetic resonance imaging (MRI) of the lung was performed at 0.43T and 1.5T in 12 healthy volunteers. A gradient-echo pulse sequence was used with a bipolar diffusion-sensitization gradient applied separately along three orthogonal directions. ADC maps, median ADC values, and signal-to-noise ratios were calculated from the diffusion-weighted images. Two readers scored the ADC maps for increased values at lung margins, major fissures, or within focal central regions. RESULTS: ADC values were found to depend on the direction of diffusion sensitization (P < 0.01, except for craniocaudal vs. anteroposterior directions at 1.5T) and were increased at the lateral and medial surfaces for left-right diffusion sensitization (12 of 12 subjects); at the apex and base (9 of 12), and along the major fissure (8 of 12), for craniocaudal diffusion sensitization; and at the most anterior and posterior lung (10 of 12) for anteroposterior diffusion sensitization. Median ADC values at 0.43T (0.201 ± 0.017, left-right; 0.193 ± 0.019, craniocaudal; and 0.187 ± 0.017 cm(2) /s, anteroposterior) were slightly lower than those at 1.5T (0.205 ± 0.017, 0.197 ± 0.017 and 0.194 ± 0.016 cm(2) /s, respectively; P < 0.05). CONCLUSION: These findings indicate that diffusion-weighted hyperpolarized (3) He MRI can detect regional anisotropy of lung-airspace orientation, including that associated with preferential orientation of terminal airways near pleural surfaces.
Asunto(s)
Medios de Contraste , Imagen de Difusión por Resonancia Magnética/métodos , Helio , Interpretación de Imagen Asistida por Computador/métodos , Pulmón/anatomía & histología , Modelos Biológicos , Adulto , Anisotropía , Simulación por Computador , Femenino , Humanos , Isótopos , Campos Magnéticos , Masculino , Radiofármacos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
Magnetic-resonance spectroscopy and imaging using hyperpolarized xenon-129 show great potential for evaluation of the most important function of the human lung -- gas exchange. In particular, chemical shift saturation recovery (CSSR) xenon-129 spectroscopy provides important physiological information for the lung as a whole by characterizing the dynamic process of gas exchange, while dissolved-phase (DP) xenon-129 imaging captures the time-averaged regional distribution of gas uptake by lung tissue and blood. Herein, we present recent advances in assessing lung function using CSSR spectroscopy and DP imaging in a total of 45 subjects (23 healthy, 13 chronic obstructive pulmonary disease (COPD) and 9 asthma). From CSSR acquisitions, the COPD subjects showed red blood cell to tissue-plasma (RBC-to-TP) ratios below the average for the healthy subjects (p < 0.001), but significantly higher septal wall thicknesses as compared with the healthy subjects (p < 0.005); the RBC-to-TP ratios for the asthmatic subjects fell outside two standard deviations (either higher or lower) from the mean of the healthy subjects, although there was no statistically significant difference for the average ratio of the study group as a whole. Similarly, from the 3D DP imaging acquisitions, we found that all the ratios (TP to gas phase (GP), RBC to GP, RBC to TP) measured in the COPD subjects were lower than those from the healthy subjects (p < 0.05 for all ratios), while these ratios in the asthmatic subjects differed considerably between subjects. Despite having been performed at different lung inflation levels, the RBC-to-TP ratios measured by CSSR and 3D DP imaging were fairly consistent with each other, with a mean difference of 0.037 (ratios from 3D DP imaging larger). In ten subjects the RBC-to-GP ratios obtained from the 3D DP imaging acquisitions were also highly correlated with their diffusing capacity of the lung for carbon monoxide per unit alveolar volume ratios measured by pulmonary function testing (R = 0.91).
Asunto(s)
Asma/fisiopatología , Pulmón/fisiopatología , Imagen por Resonancia Magnética/métodos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Pruebas de Función Respiratoria/métodos , Adolescente , Adulto , Monóxido de Carbono/metabolismo , Simulación por Computador , Eritrocitos/metabolismo , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Ventilación Pulmonar/fisiología , Análisis Espectral , Isótopos de Xenón , Adulto JovenRESUMEN
PURPOSE: To determine whether helium-3 diffusion MR can detect the changes in the lungs of healthy nonsmoking individuals who were regularly exposed to secondhand smoke. MATERIALS AND METHODS: Three groups were studied (age: 59 ± 9 years): 23 smokers, 37 exposure-to-secondhand-smoke subjects, and 29 control subjects. We measured helium-3 diffusion values at diffusion times from 0.23 to 1.97 s. RESULTS: One-way analysis of variance revealed that the mean area under the helium-3 diffusion curves (ADC AUC) of the smokers was significantly elevated compared with the controls and to the exposure-to-secondhand-smoke subjects (P < 0.001 both). No difference between the mean ADC AUC of the exposure-to-secondhand-smoke subjects and that of the controls was found (P = 0.115). However, application of a receiver operator characteristic-derived rule to classify subjects as either a "control" or a "smoker," based on ADC AUC, revealed that 30% (11/37) of the exposure-to-secondhand subjects were classified as "smokers" indicating an elevation of the ADC AUC. CONCLUSION: Using helium-3 diffusion MR, elevated ADC values were detected in 30% of nonsmoking healthy subjects who had been regularly exposed to secondhand smoke, supporting the concept that, in susceptible individuals, secondhand smoke causes mild lung damage.
Asunto(s)
Imagen de Difusión por Resonancia Magnética , Helio , Lesión Pulmonar/patología , Pulmón/efectos de los fármacos , Contaminación por Humo de Tabaco/efectos adversos , Anciano , Área Bajo la Curva , Enfisema/diagnóstico , Enfisema/patología , Exposición a Riesgos Ambientales , Femenino , Humanos , Pulmón/patología , Lesión Pulmonar/diagnóstico , Masculino , Persona de Mediana Edad , Curva ROC , Fumar/efectos adversosRESUMEN
PURPOSE: To develop a breathhold acquisition for regional mapping of ventilation and the fractions of hyperpolarized xenon-129 (Xe129) dissolved in tissue (lung parenchyma and plasma) and red blood cells (RBCs), and to perform an exploratory study to characterize data obtained in human subjects. MATERIALS AND METHODS: A three-dimensional, multi-echo, radial-trajectory pulse sequence was developed to obtain ventilation (gaseous Xe129), tissue, and RBC images in healthy subjects, smokers, and asthmatics. Signal ratios (total dissolved Xe129 to gas, tissue-to-gas, RBC-to-gas, and RBC-to-tissue) were calculated from the images for quantitative comparison. RESULTS: Healthy subjects demonstrated generally uniform values within coronal slices, and a gradient in values along the anterior-to-posterior direction. In contrast, images and associated ratio maps in smokers and asthmatics were generally heterogeneous and exhibited values mostly lower than those in healthy subjects. Whole-lung values of total dissolved Xe129 to gas, tissue-to-gas, and RBC-to-gas ratios in healthy subjects were significantly larger than those in diseased subjects. CONCLUSION: Regional maps of tissue and RBC fractions of dissolved Xe129 were obtained from a short breathhold acquisition, well tolerated by healthy volunteers and subjects with obstructive lung disease. Marked differences were observed in spatial distributions and overall amounts of Xe129 dissolved in tissue and RBCs among healthy subjects, smokers and asthmatics.
Asunto(s)
Imagenología Tridimensional/métodos , Enfermedades Pulmonares/metabolismo , Pulmón/metabolismo , Imagen por Resonancia Magnética/métodos , Intercambio Gaseoso Pulmonar , Isótopos de Xenón/farmacocinética , Administración por Inhalación , Adolescente , Adulto , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Enfermedades Pulmonares/diagnóstico , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular , Isótopos de Xenón/administración & dosificación , Adulto JovenRESUMEN
This study aimed to assess the efficacy of the radioprotector amifostine in limiting radiation toxicity in a rabbit model of lung stereotactic body radiation therapy (SBRT) by correlating contrast-enhanced magnetic resonance angiography (ce-MRA), computed tomography (CT), and helium-3 (He-3) magnetic resonance imaging (MRI) with histopathology. Multiple MRI techniques were tested to obtain complementing physiologic information. Thirteen rabbits received SBRT to the right lower lobe of the lung. Specifically, 4 received 3 × 11 Gray (Gy), 6 received 3 × 11 Gy and 50 mg/kg of amifostine pre-SRBT, and 3 received 3 × 7, 3 × 9, or 3 × 13 Gy. Imaging was performed at baseline and 4, 8, 12, and 16 weeks post-SBRT. Ce-MRA perfusion difference between lungs in the irradiated group at 16 weeks post-treatment was statistically significant (P = .04) whereas the difference in the irradiated + amifostine group was not (P = .30). Histologically observed low red blood cell (RBC) count and CT hypodensity suggests changes were primarily related to perfusion; however, structural changes, such as increased alveolar size, were also present. No changes in He-3 MRI lung ventilation were observed in either group. Although radiation-induced injury detected in rabbits as CT hypodensity contrasted with increased density observed in humans/rodents, the changes in ce-MRA and CT were still significantly reduced after the addition of amifostine to SBRT. Use of CT and selected MRI techniques helped to pinpoint primary physiologic changes.
Asunto(s)
Amifostina/farmacología , Pulmón/efectos de los fármacos , Pulmón/efectos de la radiación , Traumatismos Experimentales por Radiación/tratamiento farmacológico , Traumatismos Experimentales por Radiación/etiología , Protectores contra Radiación/farmacología , Radiocirugia/efectos adversos , Animales , Femenino , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Modelos Animales , Conejos , Traumatismos Experimentales por Radiación/patología , Tomografía Computarizada por Rayos X/métodosRESUMEN
Focused ultrasound (FUS) is a minimally invasive treatment that utilizes high-energy ultrasound waves to thermally ablate tissue. Magnetic resonance imaging (MRI) guidance may be combined with FUS (MRgFUS) to increase its accuracy and has been proposed for lung tumor ablation/debulking. However, the lungs are predominantly filled with air, which attenuates the strength of the FUS beam. This investigation aimed to test the feasibility of a new approach using an intentional lung collapse to reduce the amount of air inside the lung and a controlled hydrothorax to create an acoustic window for transcutaneous MRgFUS lung ablation. Eleven pigs had one lung mechanically ventilated while the other lung underwent a controlled collapse and subsequent hydrothorax of that hemisphere. The MRgFUS lung ablations were then conducted via the intercostal space. All the animals recovered well and remained healthy in the week following the FUS treatment. The location and size of the ablations were confirmed one week post-treatment via MRI, necropsy, and histological analysis. The animals had almost no side effects and the skin burns were completely eliminated after the first two animal studies, following technique refinement. This study introduces a novel methodology of MRgFUS that can be used to treat deep lung parenchyma in a safe and viable manner.
Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Pulmón , Animales , Porcinos , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Pulmón/patología , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Imagen por Resonancia Magnética/métodos , Estudios de Factibilidad , Modelos Animales , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/patologíaRESUMEN
Despite a myriad of technical advances in medical imaging, as well as the growing need to address the global impact of pulmonary diseases, such as asthma and chronic obstructive pulmonary disease, on health and quality of life, it remains challenging to obtain in vivo regional depiction and quantification of the most basic physiological functions of the lung-gas delivery to the airspaces and gas uptake by the lung parenchyma and blood-in a manner suitable for routine application in humans. We report a method based on MRI of hyperpolarized xenon-129 that permits simultaneous observation of the 3D distributions of ventilation (gas delivery) and gas uptake, as well as quantification of regional gas uptake based on the associated ventilation. Subjects with lung disease showed variations in gas uptake that differed from those in ventilation in many regions, suggesting that gas uptake as measured by this technique reflects such features as underlying pathological alterations of lung tissue or of local blood flow. Furthermore, the ratio of the signal associated with gas uptake to that associated with ventilation was substantially altered in subjects with lung disease compared with healthy subjects. This MRI-based method provides a way to quantify relationships among gas delivery, exchange, and transport, and appears to have significant potential to provide more insight into lung disease.
Asunto(s)
Pulmón/fisiología , Imagen por Resonancia Magnética/métodos , Ventilación Pulmonar/fisiología , Respiración , Isótopos de Xenón/metabolismo , Adulto , Anciano , Femenino , Gases/metabolismo , Humanos , Enfermedades Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Relación Ventilacion-Perfusión , Adulto JovenRESUMEN
Hyperpolarized 129Xe MRI comprises a unique array of structural and functional lung imaging techniques. Technique standardization across sites is increasingly important given the recent FDA approval of 129Xe as an MR contrast agent and as interest in 129Xe MRI increases among research and clinical institutions. Members of the 129Xe MRI Clinical Trials Consortium (Xe MRI CTC) have agreed upon best practices for each of the key aspects of the 129Xe MRI workflow, and these recommendations are summarized in a recent publication. This work provides practical information to develop an end-to-end workflow for collecting 129Xe MR images of lung ventilation according to the Xe MRI CTC recommendations. Preparation and administration of 129Xe for MR studies will be discussed and demonstrated, with specific topics including choice of appropriate gas volumes for entire studies and for individual MR scans, preparation and delivery of individual 129Xe doses, and best practices for monitoring subject safety and 129Xe tolerability during studies. Key MR technical considerations will also be covered, including pulse sequence types and optimized parameters, calibration of 129Xe flip angle and center frequency, and 129Xe MRI ventilation image analysis.