Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Indoor Air ; 29(5): 803-816, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31206776

RESUMEN

A particle exposure experiment inside a large climate-controlled chamber was conducted. Data on spatial and temporal distribution of nanoscale and fine aerosols in the range of mobility diameters 8-600 nm were collected with high resolution, for sodium chloride, fluorescein sodium, and silica particles. Exposure scenarios studied included constant and intermittent source emissions, different aggregation conditions, high (10 h-1 ) and low (3.5 h-1 ) air exchange rates (AERs) corresponding to chamber Reynolds number, respectively, equal to 1 × 105 and 3 × 104 . Results are presented and analyzed to highlight the main determinants of exposure and to determine whether the assumptions underlying two-box models hold under various scenarios. The main determinants of exposure found were the source generation rate and the ventilation rate. The effect of particles nature was indiscernible, and the decrease of airborne total number concentrations attributable to surface deposition was estimated lower than 2% when the source was active. A near-field/far-field structure of aerosol concentration was always observed for the AER = 10 h-1 but for AER = 3.5 h-1 , a single-field structure was found. The particle size distribution was always homogeneous in space but a general shift of particle diameter (-8% to +16%) was observed between scenarios in correlation with the AER and with the source position, presumably largely attributable to aggregation.


Asunto(s)
Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Humanos , Modelos Teóricos , Nanopartículas , Tamaño de la Partícula , Análisis Espacio-Temporal , Ventilación
2.
J Nanopart Res ; 20(6): 154, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29962901

RESUMEN

The assessment of the toxicity of airborne nanofibers is an important task. It relies on toxicological inhalation studies and validated exposure measurement techniques. Both require nanofiber-containing aerosols of known morphological composition and controlled fraction of individual fibers. Here, a dry powder dispersion method is presented that operates with mixtures of nanofibers and microscale beads. Aerosolization experiments of mixtures of multi-walled carbon nanotubes (MWCNTs) and glass beads that were continuously fed into a Venturi nozzle enabled high generation rates of aerosols composed of individual and agglomerate nanofiber structures. The aerosol process achieved good stability over more than 2 h with respect to concentration and aerodynamic size distribution. Its operation duration is limited only by the reservoir volume of the cyclone used to separate the beads from the aerosol. The aerosol concentration can be controlled by changing the mass ratio of MWCNTs and glass beads or by adapting the mass feed rate to the nozzle. For two agglomerated MWCNT materials, aerosol concentrations ranged from 1700 to 64,000 nano-objects per cm3. Comprehensive scanning electron microscope analysis of filter samples was performed to categorize and determine the morphological composition of the aerosol, its fiber content as well as fiber length and diameter distributions. High fractions of individual fibers of up to 34% were obtained, which shows the setup to be capable of dispersing also highly tangled MWCNT agglomerates effectively.

3.
Sci Total Environ ; 603-604: 793-806, 2017 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-28431758

RESUMEN

Exposure to airborne agents needs to be assessed in the personal breathing zone by the use of personal measurement equipment. Specific measurement devices for assessing personal exposure to airborne nanomaterials have only become available in the recent years. They can be differentiated into direct-reading personal monitors and personal samplers that collect the airborne nanomaterials for subsequent analyses. This article presents a review of the available personal monitors and samplers and summarizes the available literature regarding their accuracy, comparability and field applicability. Due to the novelty of the instruments, the number of published studies is still relatively low. Where applicable, literature data is therefore complemented with published and unpublished results from the recently finished nanoIndEx project. The presented data show that the samplers and monitors are robust and ready for field use with sufficient accuracy and comparability. However, several limitations apply, e.g. regarding the particle size range of the personal monitors and their in general lower accuracy and comparability compared with their stationary counterparts. The decision whether a personal monitor or a personal sampler shall be preferred depends strongly on the question to tackle. In many cases, a combination of a personal monitor and a personal sampler may be the best choice to obtain conclusive results.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente , Exposición por Inhalación/análisis , Nanoestructuras/análisis , Exposición Profesional/análisis , Humanos , Tamaño de la Partícula , Lugar de Trabajo
4.
Sci Total Environ ; 605-606: 929-945, 2017 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-28688352

RESUMEN

Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by coincidence, also nearly proportional to the alveolar lung-deposited surface area (LDSA), the metric reported by all three instruments. In addition, the miniDiSC/DiSCmini and the NanoTracer report particle number concentration and mean particle size. In view of their use for personal exposure studies, the comparability of these personal monitors was assessed in two measurement campaigns. Altogether 29 different polydisperse test aerosols were generated during the two campaigns, covering a large range of particle sizes, morphologies and concentrations. The data provided by the personal monitors were compared with those obtained from reference instruments: a scanning mobility particle sizer (SMPS) for LDSA and mean particle size and a ultrafine particle counter (UCPC) for number concentration. The results indicated that the LDSA concentrations and the mean particle sizes provided by all investigated instruments in this study were in the order of ±30% of the reference value obtained from the SMPS when the particle sizes of the test aerosols generated were within 20-400nm and the instruments were properly calibrated. Particle size, morphology and concentration did not have a major effect within the aforementioned limits. The comparability of the number concentrations was found to be slightly worse and in the range of ±50% of the reference value obtained from the UCPC. In addition, a minor effect of the particle morphology on the number concentration measurements was observed. The presence of particles >400nm can drastically bias the measurement results of all instruments and all metrics determined.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente/instrumentación , Nanopartículas/análisis , Exposición Profesional/análisis , Dispositivos Electrónicos Vestibles , Aerosoles , Humanos , Tamaño de la Partícula , Lugar de Trabajo
5.
Environ Pollut ; 215: 356-365, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27194367

RESUMEN

Waste disposal of carbon nanotube (CNT) containing products is expected to be the most important pathway for release of CNTs into the environment. In the present work, the use of radiolabelled CNTs ((14)C-CNT) for polycarbonate polymer nanocomposites with 1 wt% (14)C-CNT content allowed for the first time to quantify and differentiate the CNT release according to the type of impact along the materials' ageing history. After an initial exposure of the nanocomposite by solar-like irradiation, further environmental impacts were applied to composite material. They aimed at mimicking disposal site conditions that may induce further ageing effects and CNT release. This study included shaking in water, rapid temperature changes, soaking in humic acid solution as well as waste water effluent, and, finally, gentle mechanical abrasion. All ageing impacts were applied sequentially, both on pristine (control) and on solar-irradiated nanocomposites. All experiments were accompanied by absolute quantification of radioactive release as well as chemical and morphological analyses of the nanocomposite surfaces using infra-red (IR) spectroscopy, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The morphological analysis showed that spectral irradiation can uncover CNT networks on the outer nanocomposite surface layers by polymer degradation. After having subjected the solar-irradiated nanocomposite to all studied disposal site effect, the total radioactive release was quantified to amount to 64 mg CNT/m(2), whereas only 0.8 mg CNT/m(2) were found for the un-irradiated control sample. Solar degradation of polymers was thus found to significantly increase the propensity of the studied polymer nanocomposites to release CNTs during ageing effects at the product's end-of-life typical for disposal sites.


Asunto(s)
Isótopos de Carbono , Carbonatos/química , Nanocompuestos/química , Nanotubos de Carbono/química , Polímeros/química , Eliminación de Residuos/métodos , Luz Solar , Contaminantes Ambientales/química , Microscopía Electrónica de Rastreo , Espectroscopía de Fotoelectrones , Cemento de Policarboxilato/química , Radiactividad , Espectrofotometría Infrarroja
6.
Materials (Basel) ; 6(8): 3035-3063, 2013 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-28811421

RESUMEN

Indirect UV-absorption spectrometry was shown to be a valuable tool for chemical characterization of functionalized carbon nanotubes (CNTs). It complements data from X-ray photoelectron spectroscopy (XPS) or FTIR analysis since it helps to clarify the type and concentration of functional groups. The principles of indirect application of UV-spectrometry and its mathematical interpretation are discussed. Their facile application, together with their adequate sensitivity and high flexibility, make UV-absorption-based approaches a valuable alternative to fluorescence spectrometry. Here, the approach was applied to the chemical analysis of oxidizing substances on CNTs. For this, pristine CNTs of low but finite oxygen content as well as brominated CNTs were analyzed by reaction in suspension with UV-active thiol reagents and a styrene derivative. It was shown that carefully selected reagents allow differentiation and quantification of bromine and generally oxidizing entities like oxygen. For brominated CNTs, it was shown that physisorbed bromine may dominate the overall bromine content.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA