Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Environ Pollut ; 253: 667-679, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31330358

RESUMEN

Many cities fail to meet air quality standards, which results in increased risk for pulmonary disorders, including asthma. Human and experimental studies have shown that diesel exhaust (DE) particles are associated with worsening of allergic asthma. Biodiesel (BD), a cleaner fuel from renewable sources, was introduced in the eighties. Because of the reduction in particulate matter (PM) emissions, BD was expected to cause fewer adverse pulmonary effects. However, only limited data on the effect of BD emissions in asthma are available. OBJECTIVE: Determine whether BD exhaust exposure in allergic sensitized mice leads to different effects on inflammatory and functional responses compared to DE exposure. METHODS: Balb/C mice were orotracheally sensitized with House Dust Mite (HDM) or a saline solution with 3 weekly instillations. From day 9 until day 17 after sensitization, they were exposed daily to filtered air (FA), DE and BD exhaust (concentration: 600 µg/m3 PM2.5). Lung function, bronchoalveolar lavage fluid (BALF) cell counts, cytokine levels (IL-2, IL-4, IL-5, IL-17, TNF-α, TSLP) in the BALF, peribronchiolar eosinophils and parenchymal macrophages were measured. RESULTS: HDM-sensitized animals presented increased lung elastance (p = 0.046), IgG1 serum levels (p = 0.029), peribronchiolar eosinophils (p = 0.028), BALF levels of total cells (p = 0.020), eosinophils (p = 0.028), IL-5 levels (p = 0.002) and TSLP levels (p = 0.046) in BALF. DE exposure alone increased lung elastance (p = 0.000) and BALF IL-4 levels (p = 0.045), whereas BD exposure alone increased BALF TSLP levels (p = 0.004). BD exposure did not influence any parameters after HDM challenge, while DE exposed animals presented increased BALF levels of total cells (p = 0.019), lymphocytes (p = 0.000), neutrophils (p = 0.040), macrophages (p = 0.034), BALF IL-4 levels (p = 0.028), and macrophagic inflammation in the lung tissue (p = 0.037), as well as decreased IgG1 (p = 0.046) and IgG2 (p = 0.043) levels when compared to the HDM group. CONCLUSION: The results indicate more adverse pulmonary effects of DE compared to BD exposure in allergic sensitized animals.


Asunto(s)
Biocombustibles/toxicidad , Emisiones de Vehículos/toxicidad , Alérgenos , Animales , Asma/inducido químicamente , Biocombustibles/análisis , Líquido del Lavado Bronquioalveolar , Citocinas , Modelos Animales de Enfermedad , Humanos , Inflamación/inducido químicamente , Interleucina-17 , Pulmón/inmunología , Ratones , Ratones Endogámicos BALB C , Neutrófilos , Material Particulado/efectos adversos , Pruebas de Toxicidad , Emisiones de Vehículos/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA