Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Orthop Relat Res ; 480(11): 2232-2250, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36001022

RESUMEN

BACKGROUND: A nanostructured titanium surface that promotes antimicrobial activity and osseointegration would provide the opportunity to create medical implants that can prevent orthopaedic infection and improve bone integration. Although nanostructured surfaces can exhibit antimicrobial activity, it is not known whether these surfaces are safe and conducive to osseointegration. QUESTIONS/PURPOSES: Using a sheep animal model, we sought to determine whether the bony integration of medical-grade, titanium, porous-coated implants with a unique nanostructured surface modification (alkaline heat treatment [AHT]) previously shown to kill bacteria was better than that for a clinically accepted control surface of porous-coated titanium covered with hydroxyapatite (PCHA) after 12 weeks in vivo. The null hypothesis was that there would be no difference between implants with respect to the primary outcomes: interfacial shear strength and percent intersection surface (the percentage of implant surface with bone contact, as defined by a micro-CT protocol), and the secondary outcomes: stiffness, peak load, energy to failure, and micro-CT (bone volume/total volume [BV/TV], trabecular thickness [Tb.Th], and trabecular number [Tb.N]) and histomorphometric (bone-implant contact [BIC]) parameters. METHODS: Implants of each material (alkaline heat-treated and hydroxyapatite-coated titanium) were surgically inserted into femoral and tibial metaphyseal cancellous bone (16 per implant type; interference fit) and in tibial cortices at three diaphyseal locations (24 per implant type; line-to-line fit) in eight skeletally mature sheep. At 12 weeks postoperatively, bones were excised to assess osseointegration of AHT and PCHA implants via biomechanical push-through tests, micro-CT, and histomorphometry. Bone composition and remodeling patterns in adult sheep are similar to that of humans, and this model enables comparison of implants with ex vivo outcomes that are not permissible with humans. Comparisons of primary and secondary outcomes were undertaken with linear mixed-effects models that were developed for the cortical and cancellous groups separately and that included a random effect of animals, covariates to adjust for preoperative bodyweight, and implant location (left/right limb, femoral/tibial cancellous, cortical diaphyseal region, and medial/lateral cortex) as appropriate. Significance was set at an alpha of 0.05. RESULTS: The estimated marginal mean interfacial shear strength for cancellous bone, adjusted for covariates, was 1.6 MPa greater for AHT implants (9.3 MPa) than for PCHA implants (7.7 MPa) (95% CI 0.5 to 2.8; p = 0.006). Similarly, the estimated marginal mean interfacial shear strength for cortical bone, adjusted for covariates, was 6.6 MPa greater for AHT implants (25.5 MPa) than for PCHA implants (18.9 MPa) (95% CI 5.0 to 8.1; p < 0.001). No difference in the implant-bone percent intersection surface was detected for cancellous sites (cancellous AHT 55.1% and PCHA 58.7%; adjusted difference of estimated marginal mean -3.6% [95% CI -8.1% to 0.9%]; p = 0.11). In cortical bone, the estimated marginal mean percent intersection surface at the medial site, adjusted for covariates, was 11.8% higher for AHT implants (58.1%) than for PCHA (46.2% [95% CI 7.1% to 16.6%]; p < 0.001) and was not different at the lateral site (AHT 75.8% and PCHA 74.9%; adjusted difference of estimated marginal mean 0.9% [95% CI -3.8% to 5.7%]; p = 0.70). CONCLUSION: These data suggest there is stronger integration of bone on the AHT surface than on the PCHA surface at 12 weeks postimplantation in this sheep model. CLINICAL RELEVANCE: Given that the AHT implants formed a more robust interface with cortical and cancellous bone than the PCHA implants, a clinical noninferiority study using hip stems with identical geometries can now be performed to compare the same surfaces used in this study. The results of this preclinical study provide an ethical baseline to proceed with such a clinical study given the potential of the alkaline heat-treated surface to reduce periprosthetic joint infection and enhance implant osseointegration.


Asunto(s)
Antiinfecciosos , Oseointegración , Animales , Antiinfecciosos/farmacología , Durapatita/farmacología , Humanos , Prótesis e Implantes , Ovinos , Propiedades de Superficie , Titanio/farmacología
2.
Genes (Basel) ; 15(6)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38927587

RESUMEN

Landscapes are consistently under pressure from human-induced ecological change, often resulting in shifting species distributions. For some species, changing the geographical breadth of their niche space results in matching range shifts to regions other than those in which they are formally found. In this study, we employ a population genomics approach to assess potential conservation issues arising from purported range expansions into the south Texas Brush Country of two sister species of ducks: mottled (Anas fulvigula) and Mexican (Anas diazi) ducks. Specifically, despite being non-migratory, both species are increasingly being recorded outside their formal ranges, with the northeastward and westward expansions of Mexican and mottled ducks, respectively, perhaps resulting in secondary contact today. We assessed genetic ancestry using thousands of autosomal loci across the ranges of both species, as well as sampled Mexican- and mottled-like ducks from across overlapping regions of south Texas. First, we confirm that both species are indeed expanding their ranges, with genetically pure Western Gulf Coast mottled ducks confirmed as far west as La Salle county, Texas, while Mexican ducks recorded across Texas counties near the USA-Mexico border. Importantly, the first confirmed Mexican × mottled duck hybrids were found in between these regions, which likely represents a recently established contact zone that is, on average, ~100 km wide. We posit that climate- and land use-associated changes, including coastal habitat degradation coupled with increases in artificial habitats in the interior regions of Texas, are facilitating these range expansions. Consequently, continued monitoring of this recent contact event can serve to understand species' responses in the Anthropocene, but it can also be used to revise operational survey areas for mottled ducks.


Asunto(s)
Patos , Hibridación Genética , Animales , Patos/genética , Texas , Humanos , México
3.
ACS Appl Mater Interfaces ; 15(39): 46247-46260, 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37738302

RESUMEN

Bioinspired nanotopography artificially fabricated on titanium surfaces offers a solution for the rising issue of postoperative infections within orthopedics. On a small scale, hydrothermal etching has proven to deliver an effective antimicrobial nanospike surface. However, translation to an industrial setting is limited by the elevated synthesis temperature (150 °C) and associated equipment requirements. Here, for the first time, we fabricate surface nanostructures using comparatively milder synthesis temperatures (75 °C), which deliver physicochemical properties and antimicrobial capability comparable to the high-temperature surface. Using a KOH etchant, the simultaneous formation of titania and titanate crystals at both temperatures produces a one-dimensional nanostructure array. Analysis indicated that the formation mechanism comprises dissolution and reprecipitation processes, identifying the deposited titanates as hydrated layered tetra-titanates (K2Ti4O9·nH2O). A proposed nanospike formation mechanism was confirmed through the identification of a core and outer shell for individual nanostructures, primarily comprised of titanates and titania, respectively. Etching conditions dictated crystalline formation, favoring a thicker titanate core for nanorods under higher synthesis temperatures and etchant concentrations. A bactericidal investigation showed the efficacy against Gram-negative bacteria for a representative low-temperature nanosurface (34.4 ± 14.4%) was comparable to the higher temperature nanosurface (34.0 ± 17.0%), illustrating the potential of low-temperature hydrothermal synthesis. Our results provide valuable insight into the applicability of low-temperature etching protocols that are more favorable in large-scale manufacturing settings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA