Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Circ Res ; 134(10): 1306-1326, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38533639

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) demonstrate a prominent day-night rhythm, commonly presenting in the morning. Transcriptional rhythms in cardiac ion channels accompany this phenomenon, but their role in the morning vulnerability to VAs and the underlying mechanisms are not understood. We investigated the recruitment of transcription factors that underpins transcriptional rhythms in ion channels and assessed whether this mechanism was pertinent to the heart's intrinsic diurnal susceptibility to VA. METHODS AND RESULTS: Assay for transposase-accessible chromatin with sequencing performed in mouse ventricular myocyte nuclei at the beginning of the animals' inactive (ZT0) and active (ZT12) periods revealed differentially accessible chromatin sites annotating to rhythmically transcribed ion channels and distinct transcription factor binding motifs in these regions. Notably, motif enrichment for the glucocorticoid receptor (GR; transcriptional effector of corticosteroid signaling) in open chromatin profiles at ZT12 was observed, in line with the well-recognized ZT12 peak in circulating corticosteroids. Molecular, electrophysiological, and in silico biophysically-detailed modeling approaches demonstrated GR-mediated transcriptional control of ion channels (including Scn5a underlying the cardiac Na+ current, Kcnh2 underlying the rapid delayed rectifier K+ current, and Gja1 responsible for electrical coupling) and their contribution to the day-night rhythm in the vulnerability to VA. Strikingly, both pharmacological block of GR and cardiomyocyte-specific genetic knockout of GR blunted or abolished ion channel expression rhythms and abolished the ZT12 susceptibility to pacing-induced VA in isolated hearts. CONCLUSIONS: Our study registers a day-night rhythm in chromatin accessibility that accompanies diurnal cycles in ventricular myocytes. Our approaches directly implicate the cardiac GR in the myocyte excitability rhythm and mechanistically link the ZT12 surge in glucocorticoids to intrinsic VA propensity at this time.


Asunto(s)
Ritmo Circadiano , Miocitos Cardíacos , Receptores de Glucocorticoides , Animales , Receptores de Glucocorticoides/metabolismo , Receptores de Glucocorticoides/genética , Ratones , Miocitos Cardíacos/metabolismo , Masculino , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/genética , Ratones Endogámicos C57BL , Canal de Sodio Activado por Voltaje NAV1.5/metabolismo , Canal de Sodio Activado por Voltaje NAV1.5/genética , Conexina 43/metabolismo , Conexina 43/genética , Ratones Noqueados , Potenciales de Acción
2.
Circ Res ; 129(1): e1-e20, 2021 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-33849278
3.
Heart Lung Circ ; 32(10): 1198-1206, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37634968

RESUMEN

BACKGROUND: Atrial myopathy may underlie the progression of atrial fibrillation (AF) from a treatable disease to an irreversible condition with poor ablation outcomes. Electrophysiological methods to unmask areas prone to re-entry initiation could be key to defining latent atrial myopathy. METHODS: Consecutive patients referred for AF ablation were prospectively included at four institutions. Decrement evoked potential mapping (DEEP) was performed in eight left atrial sites and five right atrial sites, from two different pacing locations (endocardially from the left atrial appendage, epicardially from the proximal coronary sinus). The electrograms (EGMs) during S1 600 ms drive and after an extra stimulus (S2 at +30 ms above atrial refractoriness) were studied at each location and assessed for decremental properties. Follow-up was 12 months. RESULTS: Seventy-four patients were included and 85% had persistent AF. A total of 17,614 EGMs were individually analysed and measured. Nine percent of the EGMs showed DEEP properties (local delay of >10 ms after S2) with a mean decrement of 33±26 ms. DEEPs were more frequent in the left atrium than the right atrium (9.4% vs 8.0%; p<0.001) and more prevalent in persistent AF patients than paroxysmal AF patients (9.8% vs 4.6% p=0.001). Atrial DEEPs were more frequently unmasked in normal bipolar voltage areas and by epicardial pacing than endocardial pacing (9.6% vs 8.4%, respectively; p=0.004). Within the left atrium, the roof had the highest prevalence of DEEP EGMs. CONCLUSIONS: DEEP mapping of both atria is useful for highlighting areas with a tendency for unidirectional block and re-entry initiation. Those areas are more easily unmasked by epicardial pacing from the coronary sinus and more prevalent in persistent AF patients than in paroxysmal AF patients.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Enfermedades Musculares , Humanos , Atrios Cardíacos , Apéndice Atrial/cirugía , Enfermedades Musculares/cirugía , Potenciales Evocados
4.
J Cardiovasc Electrophysiol ; 33(1): 109-116, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34674346

RESUMEN

Endothelial dysfunction, a term used to describe both the physical damage and dysregulated physiology of this endothelial lining, is an increasingly recognized pathophysiological state shared by many cardiovascular diseases. Historically, the role of endothelial dysfunction in atrial fibrillation (AF) was thought to be limited to mediating atrial thromboembolism. However, there is emerging evidence that endothelial dysfunction both promotes and maintains atrial arrhythmic substrate, predicts adverse outcomes, and identifies patients at high risk of recurrence following cardioversion and ablation therapy. Treatments targeted at improving endothelial function also represent a promising new therapeutic paradigm in AF. This review summarizes the current understanding of endothelial function in AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Ablación por Catéter/efectos adversos , Cardioversión Eléctrica , Atrios Cardíacos , Humanos , Recurrencia , Resultado del Tratamiento
5.
Heart Lung Circ ; 31(7): 1015-1022, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35301985

RESUMEN

PURPOSE: Cardiac catheter ablations are an established treatment for supraventricular tachycardia (SVT) involving prolonged cannulation of the common femoral vein with multiple catheters. This study aimed to identify the risk of deep vein thrombosis (DVT) by studying the frequency of this complication after catheter ablation. METHODS: This was a prospective multi-centre cohort study of patients undergoing cardiac ablation for atrioventricular nodal re-entry tachycardia or right-sided accessory atrioventricular connection. Those taking anticoagulation or antiplatelet therapy prior to the procedure were excluded. Following the procedure, bilateral venous duplex ultrasonography from the popliteal vein to the inferior vena cava for DVT was undertaken at 24 hours and between 10 to 14 days. RESULTS: Eighty (80) patients (mean age 47.6 yrs [SD 13.4] with 67% female) underwent cardiac ablation (median duration 70 mins). Seven (7) patients developed acute DVT in either the femoral or external iliac vein of the intervention leg, giving a frequency of 8.8% (95% CI 3.6-17.2%). No thrombus was seen in the contralateral leg (p=0.023). An elevated D-dimer prior to the procedure was significantly more frequent in patients developing DVT (42.9% vs 4.1%, p=0.0081; OR 17.0). No other patient or procedural characteristics significantly influenced the risk of DVT. CONCLUSION: In patients without peri-procedural anticoagulation catheter ablation precipitated DVT in the catheterised femoral or iliac veins in 8.8% of patients. Peri-procedure prophylactic anticoagulation may be considered for all patients undergoing catheter ablation for SVT. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03877770.


Asunto(s)
Ablación por Catéter , Trombosis de la Vena , Anticoagulantes , Ablación por Catéter/efectos adversos , Estudios de Cohortes , Femenino , Productos de Degradación de Fibrina-Fibrinógeno , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Trombosis de la Vena/diagnóstico , Trombosis de la Vena/etiología
6.
Indian Pacing Electrophysiol J ; 22(4): 188-194, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35427782

RESUMEN

INTRODUCTION: - Local impedance (LI) guided ablation as a method of judging lesion effectiveness for cavotricuspid isthmus dependent atrial flutter (CTI-AFL), and ultra-high density (UHD) mapping when breakthrough occurred across an ablation line has not previously been assessed. METHODS: This retrospective observational study evaluated patients undergoing CTI-AFL ablation using conventional, contact force (CF) and LI guided strategies. Ablation metrics were collected, and in the LI cohort, the use of UHD mapping for breakthrough evaluated. RESULTS: 30 patients were included, 10 per group. Mean total ablation time was significantly shorter with LI (3.2 ± 1.3min) vs conventional (5.6 ± 2.7min) and CF (5.7 ± 2.0min, p = 0.0042). Time from start of ablation to CTI block was numerically shorter with LI (14.2 ± 8.0min) vs conventional and CF (19.7 ± 14.1 and 22.5 ± 19.1min, p = 0.4408). Mean lesion duration was significantly shorter with LI, but there were no differences in the number of lesions required to achieve block, procedural success, complication rates or recurrence. 15/30 patients did not achieve block following first-pass ablation. UHD mapping rapidly identified breakthrough in the five LI patients, including epicardial-endocardial breakthrough (EEB). CONCLUSION: - The use of LI during ablation for real-time lesion assessment was as efficacious as the conventional and CF methods. UHD mapping rapidly identified breakthrough, including EEB.

7.
Physiology (Bethesda) ; 34(5): 314-326, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31389775

RESUMEN

Athletes are prone to supraventricular rhythm disturbances including sinus bradycardia, heart block, and atrial fibrillation. Mechanistically, this is attributed to high vagal tone and cardiac electrical and structural remodeling. Here, we consider the supporting evidence for these three pro-arrhythmic mechanisms in athletic human cohorts and animal models, featuring current controversies, emerging data, and future directions of relevance to the translational research agenda.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Corazón/fisiopatología , Animales , Atletas , Humanos
8.
Circ Res ; 121(9): 1058-1068, 2017 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-28821541

RESUMEN

RATIONALE: Downregulation of the pacemaking ion channel, HCN4 (hyperpolarization-activated cyclic nucleotide gated channel 4), and the corresponding ionic current, If, underlies exercise training-induced sinus bradycardia in rodents. If this occurs in humans, it could explain the increased incidence of bradyarrhythmias in veteran athletes, and it will be important to understand the underlying processes. OBJECTIVE: To test the role of HCN4 in the training-induced bradycardia in human athletes and investigate the role of microRNAs (miRs) in the repression of HCN4. METHODS AND RESULTS: As in rodents, the intrinsic heart rate was significantly lower in human athletes than in nonathletes, and in all subjects, the rate-lowering effect of the HCN selective blocker, ivabradine, was significantly correlated with the intrinsic heart rate, consistent with HCN repression in athletes. Next-generation sequencing and quantitative real-time reverse transcription polymerase chain reaction showed remodeling of miRs in the sinus node of swim-trained mice. Computational predictions highlighted a prominent role for miR-423-5p. Interaction between miR-423-5p and HCN4 was confirmed by a dose-dependent reduction in HCN4 3'-untranslated region luciferase reporter activity on cotransfection with precursor miR-423-5p (abolished by mutation of predicted recognition elements). Knockdown of miR-423-5p with anti-miR-423-5p reversed training-induced bradycardia via rescue of HCN4 and If. Further experiments showed that in the sinus node of swim-trained mice, upregulation of miR-423-5p (intronic miR) and its host gene, NSRP1, is driven by an upregulation of the transcription factor Nkx2.5. CONCLUSIONS: HCN remodeling likely occurs in human athletes, as well as in rodent models. miR-423-5p contributes to training-induced bradycardia by targeting HCN4. This work presents the first evidence of miR control of HCN4 and heart rate. miR-423-5p could be a therapeutic target for pathological sinus node dysfunction in veteran athletes.


Asunto(s)
Bradicardia/metabolismo , Ejercicio Físico/fisiología , Marcación de Gen/métodos , Canales Regulados por Nucleótidos Cíclicos Activados por Hiperpolarización/metabolismo , MicroARNs/metabolismo , Proteínas Musculares/metabolismo , Condicionamiento Físico Animal/fisiología , Canales de Potasio/metabolismo , Adolescente , Adulto , Animales , Bradicardia/genética , Bradicardia/fisiopatología , Técnicas de Silenciamiento del Gen/métodos , Humanos , Canales Regulados por Nucleótidos Cíclicos Activados por Hiperpolarización/genética , Masculino , Ratones , Ratones Endogámicos C57BL , MicroARNs/genética , Proteínas Musculares/genética , Condicionamiento Físico Animal/métodos , Canales de Potasio/genética , Nodo Sinoatrial/metabolismo , Nodo Sinoatrial/fisiopatología , Adulto Joven
9.
Europace ; 19(12): 1958-1966, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28204434

RESUMEN

AIMS: Catheter ablation to achieve posterior left atrial wall (PW) isolation may be performed as an adjunct to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF). We aimed to determine whether routine adenosine challenge for dormant posterior wall conduction improved long-term outcome. METHODS AND RESULTS: A total of 161 patients with persistent AF (mean age 59 ± 9 years, AF duration 6 ± 5 years) underwent catheter ablation involving circumferential PVI followed by PW isolation. Posterior left atrial wall isolation was performed with a roof and inferior wall line with the endpoint of bidirectional block. In 54 patients, adenosine 15 mg was sequentially administered to assess reconnection of the pulmonary veins and PW. Sites of transient reconnection were ablated and adenosine was repeated until no further reconnection was present. Holter monitoring was performed at 6 and 12 months to assess for arrhythmia recurrence. Posterior left atrial wall isolation was successfully achieved in 91% of 161 patients (procedure duration 191 ± 49 min, mean RF time 40 ± 19 min). Adenosine-induced reconnection of the PW was demonstrated in 17%. The single procedure freedom from recurrent atrial arrhythmia was superior in the adenosine challenge group (65%) vs. no adenosine challenge (40%, P < 0.01) at a mean follow-up of 19 ± 8 months. After multiple procedures, there was significantly improved freedom from AF between patients with vs. without adenosine PW challenge (85 vs. 65%, P = 0.01). CONCLUSION: Posterior left atrial wall isolation in addition to PVI is a readily achievable ablation strategy in patients with persistent AF. Routine adenosine challenge for dormant posterior wall conduction was associated with an improvement in the success of catheter ablation for persistent AF.


Asunto(s)
Adenosina/administración & dosificación , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Electrocardiografía Ambulatoria , Femenino , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
10.
Circ J ; 78(6): 1272-82, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24837708

RESUMEN

The sinoatrial node (SAN) is the normal pacemaker of the heart. During a human lifetime it must initiate approximately 2 billion heartbeats and coordinate the cardiovascular response to our physiological and emotional demands. Disease of the SAN is common, and one of the leading indications for electronic pacemaker implantation. Advances in understanding the genetics and molecular mechanisms determining normal SAN function, and of the pathways controlling remodeling are revealing SAN disease to be heterogeneous. We review the contemporary concepts of SAN function, heart rate adaptation and SAN disease from the molecular level to clinical application.


Asunto(s)
Arritmias Cardíacas/genética , Arritmias Cardíacas/fisiopatología , Relojes Biológicos/genética , Fenómenos Electrofisiológicos , Nodo Sinoatrial/fisiopatología , Animales , Humanos , Marcapaso Artificial
11.
Acta Cardiol ; 69(5): 491-5, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25638836

RESUMEN

OBJECTIVE: Implantation of biventricular devices (BiV) with a transvenous left ventricular lead is complex requiring a significant fluoroscopy time and radiation dose. In the United Kingdom, the Health Protection Agency (HPA) collects data regarding radiographic procedures and sets national diagnostic reference levels (DRL) at the 75th percentile of the distribution of doses for a wide range of procedures. Insufficient data were returned to the HPA to allow them to set DRL for BiV devices at the last publication in 2010. Due to the large variation in data available and small datasets for BiV procedures we aimed to collect a large dataset to guide standards for implantation. METHODS: We collected retrospective data (fluoroscopy time and radiation dose [DAP]) for new BiV devices for the three years 2009-2011 from three high volume tertiary centres in the North West of England. Databases were scrutinised to ensure the quality of the data. RESULTS: From a total of 1374 implants we identified data for 1319 patients for fluoroscopy time and 1316 for DAP. The mean fluoroscopy time for all three centres combined was 18.7±0.3 min. The 75th percentile fluoroscopy time for the combined data was 24.2 min. The mean DAP for the three centres combined was 25.1±1.3 Gy cm2. The 75th percentile DAP for the combined data was 27.7 Gy cm2. CONCLUSIONS: We present a large dataset of new biventricular device implants, based on the 75th percentile data we suggest a DRL of 24.2 min and 27.7 Gy cm2.


Asunto(s)
Marcapaso Artificial , Dosis de Radiación , Radiografía Intervencional , Fluoroscopía , Humanos , Tempo Operativo , Estudios Retrospectivos
12.
JACC Case Rep ; 29(3): 102167, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361550

RESUMEN

The SMART Pass filter (Boston Scientific) aims to reduce inappropriate shocks (IASs) from subcutaneous implantable cardioverter-defibrillators by filtering out low-frequency signals such as T waves. However, this filter is deactivated in the presence of diminished R-wave sensing. We describe a case of IAS in the setting of extensive intra-abdominal hemorrhage.

13.
Heart Rhythm ; 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38428449

RESUMEN

Bradyarrhythmias including sinus bradycardia and atrioventricular (AV) block are frequently encountered in endurance athletes especially at night. While these are well tolerated by the young athlete, there is evidence that generally from the fifth decade of life onward, such arrhythmias can degenerate into pathological symptomatic bradycardia requiring pacemaker therapy. For many years, athletic bradycardia and AV block have been attributed to high vagal tone, but work from our group has questioned this widely held assumption and demonstrated a role for intrinsic electrophysiological remodeling of the sinus node and the AV node. In this article, we argue that bradyarrhythmias in the veteran athlete arise from the cumulative effects of exercise training, the circadian rhythm and aging on the electrical activity of the nodes. We consider contemporary strategies for the treatment of symptomatic bradyarrhythmias in athletes and highlight potential therapies resulting from our evolving mechanistic understanding of this phenomenon.

14.
J Cardiovasc Electrophysiol ; 24(9): 1059-65, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24016320

RESUMEN

Due to expanding clinical indications and an aging society there has been an increase in the use of implantable pacemakers. At the same time, due to increased diagnostic yield over other imaging modalities and the absence of ionizing radiation, there has been a surge in demand for magnetic resonance imaging (MRI) assessment, of both cardiac and noncardiac conditions. Patients with an implantable device have a 50-75% chance of having a clinical indication for MRI during the lifetime of their device. The presence of an implantable cardiac device has been seen as a relative contraindication to MRI assessment, limiting the prognostic and diagnostic utility of MRI in many patients with these devices. The introduction of MRI conditional pacemakers will enable more patients to undergo routine MRI assessment without risk of morbidity or device malfunction. This review gives a general overview of the principles and current evidence for the use of MRI conditional implantable cardiac devices. Furthermore, we appraise the differences between those pacemakers currently released to market.


Asunto(s)
Desfibriladores Implantables/normas , Imagen por Resonancia Magnética/normas , Marcapaso Artificial/normas , Animales , Desfibriladores Implantables/tendencias , Seguridad de Equipos/normas , Seguridad de Equipos/tendencias , Humanos , Imagen por Resonancia Magnética/tendencias , Marcapaso Artificial/tendencias
15.
Card Electrophysiol Clin ; 15(2): 169-181, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37076229

RESUMEN

This review summarizes the evidence for left atrial appendage closure (LAAC) as an alternative to oral anticoagulation (OAC) for stroke prevention in atrial fibrillation. LAAC reduces hemorrhagic stroke and mortality versus warfarin, but is inferior for ischemic stroke reduction based on randomized data. Whilst a feasible treatment in OAC-ineligible patients, questions remain over procedural safety, and the improvement in complications observed in nonrandomized registries is uncorroborated by contemporary randomized trials. Management of device-related thrombus and peridevice leak remain unclear, and robust randomized data versus direct OACs are required before recommendations can be made for widespread adoption in OAC-eligible populations.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/etiología , Apéndice Atrial/cirugía , Resultado del Tratamiento , Warfarina , Anticoagulantes/uso terapéutico
16.
J Innov Card Rhythm Manag ; 14(5): 5442-5450, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37216082

RESUMEN

The learning curve for the novel RHYTHMIA HDx™ 3-dimensional electroanatomic system is unknown. Retrospective data collection was carried out at 3 U.K. centers from the introduction of RHYTHMIA HDx™ (Boston Scientific, Marlborough, MA, USA) and associated mapping and ablation catheters. Patients were matched with controls using the CARTO® 3 mapping system (Biosense Webster Inc., Diamond Bar, CA, USA). Fluoroscopy, radiofrequency ablation, and procedure times; acute and long-term success; and complications were assessed. A total of 253 study patients along with 253 controls were included. Significant correlations existed between procedural efficiency metrics and center experience for de novo atrial fibrillation (AF) ablation (procedure time, Spearman's ρ = -0.624; ablation time, ρ = -0.795; both P < .0005) and de novo atrial flutter (AFL) ablation (ablation time, ρ = -0.566; fluoroscopy time, ρ = -0.520; both P = .001). No correlations existed for other assessed atrial arrhythmias. For de novo AF and AFL, metrics significantly improved after 10 procedures in each center (procedure time [AF only, P = .001], ablation time [AF, P < .0005; AFL, P < .0005], and fluoroscopy time [AFL only, P = .0022]) and became comparable to those of controls. Acute success and long-term success did not experience significant improvements with experience, but they were comparable to the control group throughout. Complications with RHYTHMIA HDx™ were comparable to those associated with CARTO® 3. In conclusion, a short learning curve exists with the use of RHYTHMIA HDx™ for standardized procedures (de novo AF/AFL). Procedural performance improved and became comparable to that seen with CARTO® 3 following 10 cases at each center. Clinical outcomes at 6 and 12 months and complications were no different from those observed in controls.

17.
Interv Cardiol Clin ; 11(2): 171-183, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35361462

RESUMEN

This review summarizes the evidence for left atrial appendage closure (LAAC) as an alternative to oral anticoagulation (OAC) for stroke prevention in atrial fibrillation. LAAC reduces hemorrhagic stroke and mortality versus warfarin, but is inferior for ischemic stroke reduction based on randomized data. Whilst a feasible treatment in OAC-ineligible patients, questions remain over procedural safety, and the improvement in complications observed in nonrandomized registries is uncorroborated by contemporary randomized trials. Management of device-related thrombus and peridevice leak remain unclear, and robust randomized data versus direct OACs are required before recommendations can be made for widespread adoption in OAC-eligible populations.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Accidente Cerebrovascular , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Warfarina
18.
Front Physiol ; 12: 592229, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33746765

RESUMEN

BACKGROUND: The sinoatrial/sinus node (SAN) is the primary pacemaker of the heart. In humans, SAN is surrounded by the paranodal area (PNA). Although the PNA function remains debated, it is thought to act as a subsidiary atrial pacemaker (SAP) tissue and become the dominant pacemaker in the setting of sinus node disease (SND). Large animal models of SND allow characterization of SAP, which might be a target for novel treatment strategies for SAN diseases. METHODS: A goat model of SND was developed (n = 10) by epicardially ablating the SAN and validated by mapping of emergent SAP locations through an ablation catheter and surface electrocardiogram (ECG). Structural characterization of the goat SAN and SAP was assessed by histology and immunofluorescence techniques. RESULTS: When the SAN was ablated, SAPs featured a shortened atrioventricular conduction, consistent with the location in proximity of atrioventricular junction. SAP recovery time showed significant prolongation compared to the SAN recovery time, followed by a decrease over a follow-up of 4 weeks. Like the SAN tissue, the SAP expressed the main isoform of pacemaker hyperpolarization-activated cyclic nucleotide-gated channel 4 (HCN4) and Na+/Ca2+ exchanger 1 (NCX1) and no high conductance connexin 43 (Cx43). Structural characterization of the right atrium (RA) revealed that the SAN was located at the earliest activation [i.e., at the junction of the superior vena cava (SVC) with the RA] and was surrounded by the paranodal-like tissue, extending down to the inferior vena cava (IVC). Emerged SAPs were localized close to the IVC and within the thick band of the atrial muscle known as the crista terminalis (CT). CONCLUSIONS: SAN ablation resulted in the generation of chronic SAP activity in 60% of treated animals. SAP displayed development over time and was located within the previously discovered PNA in humans, suggesting its role as dominant pacemaker in SND. Therefore, SAP in goat constitutes a promising stable target for electrophysiological modification to construct a fully functioning pacemaker.

19.
Prog Biophys Mol Biol ; 166: 61-85, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34197836

RESUMEN

The funny current, If, was first recorded in the heart 40 or more years ago by Dario DiFrancesco and others. Since then, we have learnt that If plays an important role in pacemaking in the sinus node, the innate pacemaker of the heart, and more recently evidence has accumulated to show that If may play an important role in action potential conduction through the atrioventricular (AV) node. Evidence has also accumulated to show that regulation of the transcription and translation of the underlying Hcn genes plays an important role in the regulation of sinus node pacemaking and AV node conduction under normal physiological conditions - in athletes, during the circadian rhythm, in pregnancy, and during postnatal development - as well as pathological states - ageing, heart failure, pulmonary hypertension, diabetes and atrial fibrillation. There may be yet more pathological conditions involving changes in the expression of the Hcn genes. Here, we review the role of If and the underlying HCN channels in physiological and pathological changes of the sinus and AV nodes and we begin to explore the signalling pathways (microRNAs, transcription factors, GIRK4, the autonomic nervous system and inflammation) involved in this regulation. This review is dedicated to Dario DiFrancesco on his retirement.


Asunto(s)
Fibrilación Atrial , Nodo Atrioventricular , Potenciales de Acción , Frecuencia Cardíaca , Humanos , Nodo Sinoatrial
20.
Pacing Clin Electrophysiol ; 33(11): 1392-406, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20946278

RESUMEN

The sinoatrial node is the primary pacemaker of the heart. Nodal dysfunction with aging, heart failure, atrial fibrillation, and even endurance athletic training can lead to a wide variety of pathological clinical syndromes. Recent work utilizing molecular markers to map the extent of the node, along with the delineation of a novel paranodal area intermediate in characteristics between the node and the surrounding atrial muscle, has shown that pacemaker tissue is more widely spread in the right atrium than previously appreciated. This can explain the phenomenon of a "wandering pacemaker" and concomitant changes in the P-wave morphology. Extensive knowledge now exists regarding the molecular architecture of the node (in particular, the expression of ion channels) and how this relates to pacemaking. This review is an up-to-date summary of the current state of our appreciation of the above topics.


Asunto(s)
Nodo Sinoatrial/anatomía & histología , Nodo Sinoatrial/fisiología , Envejecimiento , Animales , Arritmias Cardíacas/fisiopatología , Función del Atrio Derecho/fisiología , Relojes Biológicos/fisiología , Diabetes Mellitus Tipo 2/fisiopatología , Perros , Femenino , Uniones Comunicantes/fisiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Canales Iónicos/fisiología , Ratones , Resistencia Física/fisiología , Ratas , Síndrome del Seno Enfermo/genética , Síndrome del Seno Enfermo/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA