1.
BMC Oral Health ; 23(1): 207, 2023 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-37029396

RESUMEN

BACKGROUND: The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate. METHODS: 32 endocrowns were fabricated on prepared mandibular molars and divided into two groups (n = 16) according to the material. Group L: lithium disilicate and Group P: PEEK. Each group was further subdivided into two subgroups (n = 8) according to the occlusal preparation design: full occlusal coverage (LF and PF) and partial occlusal coverage (LP and PP). Samples were analyzed using microcomputed tomography (µCT) with a voxel size of 6 µm to evaluate internal fit, and an optical microscope was used to evaluate the marginal gap. Data were collected, tabulated, and statistically analyzed. Numerical data were described as mean and standard deviation and compared using the ANOVA test. The level of significance was set at α P ≤ 0.05. RESULTS: All groups' internal fit and marginal gaps values were within the acceptable clinical range. However, the lithium disilicates group recorded statistically significantly higher mean internal gap values than the PEEK groups. Regardless of the material, the difference between the two occlusal designs was not statistically significant in both internal fit and marginal gap records. CONCLUSION: Within the limitations of this study, PEEK endocrown restorations revealed better internal fit and marginal gap than lithium disilicate endocrown restorations. The marginal and internal fit of both lithium disilicate and PEEK endocrown restorations were within the clinically acceptable range. The occlusal preparation design had no influence on the internal fit and marginal gap of the endocrown restoration.


Asunto(s)
Cerámica , Coronas , Humanos , Microtomografía por Rayos X , Diseño Asistido por Computadora , Adaptación Marginal Dental , Diseño de Prótesis Dental/métodos , Éteres , Ensayo de Materiales
2.
Minerva Dent Oral Sci ; 72(6): 280-290, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37255305

RESUMEN

BACKGROUND: This in vitro study assessed the wear behavior of different CAD-CAM blocks and the abrasion of the enamel antagonist against these materials. METHODS: 64 disk-shaped specimens were prepared from 8 different CAD/CAM blocks as follow: one lithium disilicate glass ceramics block "IPS Emax CAD" as control group, two zirconia reinforced lithium silicate "Vita Suprinity & Celtra DUO," one interpenetrating network ceramic block "Vita Enamic," Three resin-based block composites "Lava Ultimate, Cerasmart & Brilliant-crios" as well as one hybrid nanoceramic "Shofu block HC". All specimens were mounted against canine and tested for two body wear analysis using a chewing simulating loading machine (100,000 cycles, 50 N, 5/55 °C). The amount of wear loss was measured for each specimen using a digital precise scale. Wear area before and after the chewing simulation were evaluated using an optical profilometer. Data analysed using one-way ANOVA test followed by Tukey's post hoc. RESULTS: The results showed a significantly higher wear loss in resin matrix ceramics in comparison to glass ceramics. However, for tooth wear glass ceramics had significantly higher value than hybrid ceramics. CONCLUSIONS: Resin based CAD/CAM Blocks gives a superior result when evaluating the wear behavior and its effect on the opposing tooth surface.


Asunto(s)
Materiales Dentales , Estética Dental , Ensayo de Materiales , Resinas de Plantas , Diseño Asistido por Computadora