Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Clin Microbiol ; 57(9)2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31217268

RESUMEN

Advanced microbiology technologies are rapidly changing our ability to diagnose infections, improve patient care, and enhance clinical workflow. These tools are increasing the breadth, depth, and speed of diagnostic data generated per patient, and testing is being moved closer to the patient through rapid diagnostic technologies, including point-of-care (POC) technologies. While select stakeholders have an appreciation of the value/importance of improvements in the microbial diagnostic field, there remains a disconnect between clinicians and some payers and hospital administrators in terms of understanding the potential clinical utility of these novel technologies. Therefore, a key challenge for the clinical microbiology community is to clearly articulate the value proposition of these technologies to encourage payers to cover and hospitals to adopt advanced microbiology tests. Specific guidance on how to define and demonstrate clinical utility would be valuable. Addressing this challenge will require alignment on this topic, not just by microbiologists but also by primary care and emergency room (ER) physicians, infectious disease specialists, pharmacists, hospital administrators, and government entities with an interest in public health. In this article, we discuss how to best conduct clinical studies to demonstrate and communicate clinical utility to payers and to set reasonable expectations for what diagnostic manufacturers should be required to demonstrate to support reimbursement from commercial payers and utilization by hospital systems.


Asunto(s)
Enfermedades Transmisibles/diagnóstico , Pruebas Diagnósticas de Rutina/métodos , Técnicas Microbiológicas/métodos , Pruebas Diagnósticas de Rutina/tendencias , Humanos , Técnicas Microbiológicas/tendencias , Sistemas de Atención de Punto/tendencias
2.
Sex Transm Infect ; 95(2): 87-93, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30126947

RESUMEN

OBJECTIVES: Infections due to Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are among the most common bacterial sexually transmitted infections worldwide, most of which are asymptomatic. Detection of infection using a variety of specimen types in symptomatic and asymptomatic subjects is important to effectively combat CT/NG infections. The performance of the cobas CT/NG v2.0 test was assessed for urogenital swabs, urine and cervical cytology samples collected in PreservCyt Solution from 5266 symptomatic and asymptomatic women (including 202 who were pregnant), and urine from 738 men. METHODS: Sensitivity and specificity were estimated compared with a patient infected status determined using two US Food and Drug Administration-cleared nucleic acid amplification tests. RESULTS: Among 6004 participants, 487 CT (8.1%) and 159 NG (2.6%) infections were identified. Sensitivity estimates for CT for women ranged from 91.2% to 97.6% depending on specimen type, and the estimate for male urine specimens was 98.4%. Specificity for CT ranged from 99.2% to 99.7%. Sensitivity estimates for NG ranged from 95.6% to 100.0% for women, and the estimate for men was 100.0%. Specificity for NG ranged from 99.3% to 100.0%. CONCLUSIONS: The cobas CT/NG v2.0 test performs well using urogenital swabs, urine and cervical samples collected in PreservCyt solution.


Asunto(s)
Infecciones por Chlamydia/diagnóstico , Chlamydia trachomatis/aislamiento & purificación , Gonorrea/diagnóstico , Neisseria gonorrhoeae/aislamiento & purificación , Juego de Reactivos para Diagnóstico , Adulto , Cuello del Útero/citología , Cuello del Útero/microbiología , Infecciones por Chlamydia/orina , Femenino , Gonorrea/orina , Humanos , Masculino , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico/métodos , Sensibilidad y Especificidad , Frotis Vaginal , Adulto Joven
3.
J Clin Microbiol ; 55(12): 3426-3436, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28954901

RESUMEN

Nucleic acid amplification tests (NAATs) are reliable tools for the detection of toxigenic Clostridium difficile from unformed (liquid or soft) stool samples. The objective of this study was to evaluate performance of the cobas Cdiff test on the cobas 4800 system using prospectively collected stool specimens from patients suspected of having C. difficile infection (CDI). The performance of the cobas Cdiff test was compared to the results of combined direct and broth-enriched toxigenic culture methods in a large, multicenter clinical trial. Additional discrepancy analysis was performed by using the Xpert C. difficile Epi test. Sample storage was evaluated by using contrived and fresh samples before and after storage at -20°C. Testing was performed on samples from 683 subjects (306 males and 377 females); 113 (16.5%) of 683 subjects were positive for toxigenic C. difficile by direct toxigenic culture, and 141 of 682 subjects were positive by using the combined direct and enriched toxigenic culture method (reference method), for a prevalence rate of 20.7%. The sensitivity and specificity of the cobas Cdiff test compared to the combined direct and enriched culture method were 92.9% (131/141; 95% confidence interval [CI], 87.4% to 96.1%) and 98.7% (534/541; 95% CI, 97.4% to 99.4%), respectively. Discrepancy analysis using results for retested samples from a second NAAT (Xpert C. difficile/Epi test; Cepheid, Sunnyvale, CA) found no false-negative and 4 false-positive cobas Cdiff test results. There was no difference in positive and negative results in comparisons of fresh and stored samples. These results support the use of the cobas Cdiff test as a robust aid in the diagnosis of CDI.


Asunto(s)
Toxinas Bacterianas/genética , Clostridioides difficile/aislamiento & purificación , Infecciones por Clostridium/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Clostridioides difficile/genética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Técnicas de Amplificación de Ácido Nucleico/métodos , Estudios Prospectivos , Sensibilidad y Especificidad , Temperatura , Adulto Joven
4.
J Appl Lab Med ; 4(3): 422-426, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31659080

RESUMEN

BACKGROUND: Healthcare providers who have access to tests at the point of care (POC) are increasingly requesting the same performance from the POC test as they expect from the laboratory. With the introduction of the cobas® Liat instrument, highly sensitive molecular diagnostic testing can be performed closer to the patient in CLIA-waived, POC settings. As more sensitive tests become available, there is concern regarding contamination of instrumentation owing to improper handling, mistakes made when processing, or environmental contamination. Recent concerns were raised when a nurse performed environmental surveillance for flu A/B by inserting a dry swab into the cobas Liat instrument and then ran it as a sample on the instrument, generating a positive result. This finding stimulated questions about the possibility of system contamination contributing to false-positive results, ultimately leading to the possibility of providing incorrect treatment to patients. METHODS: To assess the likelihood of system contamination contributing to the generation of false-positive results, in this study we contaminated a cobas Liat System with flu A/B-positive control material. The system contamination was then assessed by swabbing exposed surfaces. Following confirmed system contamination, negative control samples were processed to determine whether system contamination had an impact on the expected negative results. RESULTS: Instrument contamination was confirmed, and no detectable flu A/B signal was observed for any of the negative control tubes run immediately following confirmation of system contamination. CONCLUSION: Environmental contamination of the Liat instrument does not have an impact on the integrity of the result.


Asunto(s)
Contaminación de Equipos , Virus de la Influenza A/genética , Virus de la Influenza B/genética , Gripe Humana/diagnóstico , Gripe Humana/virología , Pruebas en el Punto de Atención , Reacción en Cadena de la Polimerasa , Humanos , Sistemas de Atención de Punto/normas , Pruebas en el Punto de Atención/normas , Reacción en Cadena de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Am J Clin Pathol ; 148(2): 119-127, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28898981

RESUMEN

OBJECTIVES: Health care-associated methicillin-resistant Staphylococcus aureus (MRSA) and Staphylococcus aureus (SA) infections are continuing problems. Rapidly determining the MRSA colonization status of a patient facilitates practice to reduce spread of MRSA clinical disease. Sensitive detection of all SA prior to surgery, followed by decolonization, can significantly reduce postoperative infection from this pathogen. Our goal was to validate a new automated assay for this testing. METHODS: We compared performance of the cobas MRSA/SA Test on the cobas 4800 System to direct and enriched chromogenic culture using nasal swabs collected from patients at six United States sites. RESULTS: Compared to direct and enriched culture, the sensitivity for MRSA and SA was 93.1% and 93.9%, and the specificity was 97.5% and 94.2%, respectively. After discrepancy analysis, the sensitivity for MRSA and SA was 97.1% and 98.6%, and the specificity was 98.3% and 95.5%, respectively. Compared to direct culture, sensitivity for detecting any SA was 99.6%. CONCLUSIONS: The cobas MRSA/SA Test is an effective tool to simultaneously perform surveillance testing for nasal colonization of both MRSA and MSSA.


Asunto(s)
Técnicas Bacteriológicas/métodos , Cavidad Nasal/microbiología , Infecciones Estafilocócicas/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , ADN Bacteriano/análisis , ADN Bacteriano/aislamiento & purificación , Femenino , Humanos , Masculino , Staphylococcus aureus Resistente a Meticilina/aislamiento & purificación , Persona de Mediana Edad , Líquido del Lavado Nasal/microbiología , Prevalencia , Reacción en Cadena en Tiempo Real de la Polimerasa , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/aislamiento & purificación , Adulto Joven
7.
J Mol Diagn ; 14(4): 367-75, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22584139

RESUMEN

Rapid detection of nasal colonization with methicillin-resistant Staphylococcus aureus (MRSA) followed by appropriate infection control procedures reduces MRSA infection and transmission. We compared the performance and workflow of two Food and Drug Administration-approved nucleic acid amplification assays, the LightCycler MRSA Advanced Test and the Xpert MRSA test, with those of directly plated culture (MRSASelect) using 1202 nasal swabs collected at three U.S. sites. The sensitivity of the LightCycler test (95.2%; 95% CI, 89.1% to 98.4%) and Xpert assay (99%; 95% CI, 94.8% to 100%) did not differ compared with that of culture; the specificity of the two assays was identical (95.5%; 95% CI, 94.1% to 96.7%) compared with culture. However, sequencing performed on 71 samples with discordant results among the three methods confirmed the presence of MRSA in 40% of samples that were positive by both molecular methods but negative by culture. Workflow analysis from all sites including batch runs revealed average hands-on sample preparation times of 1.40, 2.35, and 1.44 minutes per sample for the LightCycler, Xpert, and MRSASelect methods, respectively. Discrete event simulation analysis of workflow efficiencies revealed that the LightCycler test used less hands-on time for the assay when greater than eight batched samples were run. The high sensitivity and specificity, low hands-on time, and efficiency gains using batching capabilities make the LightCycler test suitable for rapid batch screening of MRSA colonization.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina/patogenicidad , Nariz/microbiología , Infecciones Estafilocócicas/diagnóstico , Humanos , Flujo de Trabajo
8.
J Biol Chem ; 278(5): 2792-8, 2003 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-12427760

RESUMEN

Shigella flexneri causes a self-limiting gastroenteritis in humans, characterized by severe localized inflammation and ulceration of the colonic mucosa. Shigellosis most often targets young children in underdeveloped countries. Invasion plasmid antigen C (IpaC) has been identified as the primary effector protein for Shigella invasion of epithelial cells. Although an initial model of IpaC function has been developed, no detailed structural information is available that could assist in a better understanding of the molecular basis for its interactions with the host cytoskeleton and phospholipid membrane. We have therefore initiated structural studies of IpaC, IpaC I', (residues 101-363 deleted), and IpaC Delta H (residues 63-170 deleted). The secondary and tertiary structure of the protein was examined as a function of temperature, employing circular dichroism and high resolution derivative absorbance techniques. ANS (8-anilino-1-napthalene sulfonic acid) was used to probe the exposure of the hydrophobic surfaces under different conditions. The interaction of IpaC and these mutants with a liposome model (liposomes with entrapped fluorescein) was also examined. Domain III (residues 261-363) was studied using linker-scanning mutagenesis. It was shown that domain III contains periodic, sequence-dependent activity, suggesting helical structure in this section of the protein. In addition to these structural studies, investigation into the actin nucleation properties of IpaC was conducted, and actin nucleation by IpaC and some of the mutants was exhibited. Structure-function relationships of IpaC are discussed.


Asunto(s)
Antígenos Bacterianos/química , Shigella flexneri/genética , Actinas/metabolismo , Antígenos Bacterianos/genética , Antígenos Bacterianos/fisiología , Dicroismo Circular , Liposomas/química , Plásmidos , Espectrometría de Fluorescencia/métodos , Termodinámica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA