Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 31(14): 1663-5, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20630896

RESUMEN

This follow-on article (see below) comparing the differences between the Edwards-Sapien valve (ESV) and the Medtronic CoreValve (MCV) discusses transcatheter valve technologies from the point of view of a world-renowned team of cardiac experts led by Dr Sanjeevan Pasupati from Waikato Hospital, New Zealand, which has deployed both the ESV and the MCV technology since 2008.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Angioplastia Coronaria con Balón/métodos , Humanos , Diseño de Prótesis , Stents
2.
Int J Cardiol ; 170(3): 406-12, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24309083

RESUMEN

BACKGROUND: We report the findings of the SOURCE-ANZ registry of the clinical outcomes of the Edwards SAPIEN™ Transcatheter Heart Valve (THV) in the Australian and New Zealand (ANZ) clinical environment. METHODS: This single arm registry of select patients treated in eight centres, represent the initial experience within ANZ with the balloon expandable Edwards SAPIEN THV delivered by transfemoral (TF) and transapical (TA) access. RESULTS: The total enrolment for the study was 132 patients, 63 patients treated by TF, 56 by TA, and 2 patients were withdrawn from the study. The mean ages: 83.7 (TF) and 81.7 (TA), female: 34.3% (TF) and 61.3% (TA), logistic EuroSCORE: 26.8% (TF) and 28.8% (TA), and with procedural success (successful implant without conversion to surgery or death): 92.4% (TF) and 87.1% (TA) (p=0.32). Outcomes were not significantly different between TF and TA implants. These included one year mortality of 13.6% (TF) and 21.7% (TA) (p=0.24), MACCE: 16.7% (TF) and 28.3% (TA) (p=0.12), pacemaker: 4.6% (TF) and 8.3% (TA) (p=0.39), and VARC major vascular complication of 4.6% (TF) and 5.0% (TA) (p=0.91). CONCLUSION: TAVI in the ANZ clinical environment has demonstrated excellent outcomes for both the TA and TF approaches in highly selected patients. These results are consistent with those demonstrated in European, Canadian registries and the pivotal US clinical trials. ACTRN12611001026910.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/mortalidad , Prevalencia , Estudios Prospectivos , Sistema de Registros/estadística & datos numéricos , Factores de Riesgo , Resultado del Tratamiento , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA