Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Gac Med Mex ; 158(6): 369-375, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36657112

RESUMEN

INTRODUCTION: Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients. OBJECTIVE: To evaluate the safety and efficacy of the National Institute of Cardiology (INC) bioprosthetic heart valve in humans. METHODS: Single-center study that included 341 patients who underwent single surgical aortic valve replacement with INC heart valve. RESULTS: 318 implants were performed de novo (93%) and 23 as redo surgery (7%); STS scores were 1.4 and 1.8%, and follow-up was for 42 and 46 months, respectively. There were no differences in clinical complications or pacemaker implantation rate. Both groups maintained a normal LVEF. Overall improvement in functional class was observed, with worsening only in two patients of the de novo group. INC prosthesis dysfunction requiring surgical reintervention was observed in eight patients (4.65%) of the de novo group vs. one patient in the redo group. CONCLUSIONS: The INC heart valve is efficacious and safe, and is associated with a low rate of complications and functional class improvement during long-term follow-up. Prospective, comparative studies of this valve are required.


INTRODUCCIÓN: Las bioprótesis de válvulas cardiacas son el estándar de oro para el reemplazo quirúrgico de la válvula aórtica en pacientes seleccionados. OBJETIVO: Evaluar la seguridad y eficacia de la válvula cardiaca bioprotésica del Instituto Nacional de Cardiología (INC) en humanos. MÉTODOS: Estudio unicéntrico que incluyó 341 pacientes que se sometieron a reemplazo valvular quirúrgico único de válvula aórtica con válvula INC. RESULTADOS: Se realizaron 318 implantes de novo (93 %) y 23 como segunda cirugía (7 %); las puntuaciones STS fueron de 1.4 y 1.8 % y el seguimiento de 42 y 46 meses, respectivamente. No existieron diferencias en las complicaciones ni en la tasa de implantación de marcapasos. Ambos grupos mantuvieron una FEVI normal. Se observó mejoría global en la clase funcional con empeoramiento solo en dos pacientes del grupo de novo. La disfunción de la prótesis INC que ameritó reintervención quirúrgica se observó en ocho pacientes (4.65 %) del grupo de novo versus un paciente (7.69 %) con segunda cirugía. CONCLUSIONES: La válvula cardiaca INC es eficaz y segura, se asocia a baja tasa de complicaciones y mejoría de la clase funcional durante el seguimiento a largo plazo. Se necesitan estudios prospectivos comparativos de esta válvula.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiología , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Prospectivos , Válvula Aórtica/cirugía , Falla de Prótesis , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Reoperación
2.
Rev Invest Clin ; 72(1): 19-24, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32132739

RESUMEN

BACKGROUND: Previous studies have shown an association between polymorphisms of the BAT1-NF-κB inhibitor-like-1 (NFKBIL1)-LTA genomic region and susceptibility to myocardial infarction and acute coronary syndrome (ACS). OBJECTIVE: The objective of the study was to study the role of three polymorphisms in the BAT1, NFKBIL1, and LTA genes on the susceptibility or protection against ACS; we included a group of cases-controls from Central Mexico. METHODS: The BAT1 rs2239527C/G, NFKBIL1 rs2071592T/A, and LTA rs1800683G/A polymorphisms were genotyped using a 5' TaqMan assay in a group of 625 patients with ACS and 617 healthy controls. RESULTS: Under a recessive model, the BAT1 -23C/G (rs2239527) polymorphism showed an association with protection against ACS (odds ratio = 0.56, and p-corrected = 0.019). In contrast, the genotype and allele frequencies of the NFKBIL1 rs2071592T/A and LTA rs1800683G/A polymorphisms were similar between ACS patients and controls and no association was identified. CONCLUSION: Our data suggest an association between the BAT1 -23C/G polymorphism and protection against ACS in Mexican patients.


Asunto(s)
Síndrome Coronario Agudo/genética , ARN Helicasas DEAD-box/genética , Infarto del Miocardio/genética , Proteínas Adaptadoras Transductoras de Señales/genética , Anciano , Estudios de Casos y Controles , Femenino , Frecuencia de los Genes , Predisposición Genética a la Enfermedad , Genotipo , Humanos , Linfotoxina-alfa/genética , Masculino , México , Persona de Mediana Edad , Polimorfismo de Nucleótido Simple
3.
Rev Invest Clin ; 72(1): 32-36, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32132738

RESUMEN

BACKGROUND: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. METHODS: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. PRESENTATION OF CASES: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. CONCLUSIONS: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Asunto(s)
Isquemia Miocárdica/cirugía , Diseño de Prótesis , Stents , Adulto , Anciano , Estudios de Seguimiento , Humanos , Masculino , México , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Proyectos Piloto , Resultado del Tratamiento , Ultrasonografía
4.
Gac Med Mex ; 156(4): 279-285, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32831335

RESUMEN

INTRODUCTION: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. OBJECTIVE: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs' antiproliferative activity and histological results. METHOD: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. RESULTS: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. CONCLUSIONS: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


INTRODUCCIÓN: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. OBJETIVO: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. MÉTODO: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. RESULTADOS: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. CONCLUSIONES: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Asunto(s)
Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Sirolimus/administración & dosificación , Animales , Modelos Animales de Enfermedad , Femenino , Estudios de Seguimiento , Masculino , Microscopía , Diseño de Prótesis , Conejos , Espectrofotometría Infrarroja , Porcinos
5.
Arch Cardiol Mex ; 93(4): 391-397, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37972366

RESUMEN

OBJECTIVE: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. METHODS: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. RESULTS: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. CONCLUSIONS: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.


OBJETIVO: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. MÉTODOS: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. RESULTADOS: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. CONCLUSIONES: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.


Asunto(s)
Cardiología , Respiración Artificial , Animales , Humanos , Porcinos , Espirometría , Respiración Artificial/instrumentación
6.
Arch Cardiol Mex ; 92(3): 334-341, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34594055

RESUMEN

OBJECTIVE: We evaluated whether cholesteryl ester transfer protein (CETP) gene polymorphisms are associated with the presence of coronary artery disease (CAD) and/or restenosis in patients with coronary stent. METHODS: Two polymorphisms of the CETP gene [-971 A/G (rs4783961), and Taq1B A/G (rs708272)] were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD (66 patients with restenosis and 153 without restenosis) and 607 control individuals. RESULTS: The distribution of polymorphisms was similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under dominant model, the G allele of the Taq1B A/G polymorphism was associated with increased risk of CAD (odds ratio [OR] = 1.48, pCDom = 0.032). In the same way, under codominant, dominant, and additive models, the A allele of the -971 A/G polymorphisms was associated with an increased risk of developing CAD (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0.008, and OR = 1.39, pCAdd = 0.011, respectively). In addition, the linkage disequilibrium showed that the "AG" haplotype was associated with increased risk of developing CAD (OR = 1.28, p = 0.03). CONCLUSION: This study demonstrates that CETP Taq1B A/G and CETP -971 A/G polymorphisms are associated with an increased risk of developing CAD, but no association with restenosis was observed.


OBJETIVO: Evaluamos si los polimorfismos del gen CETP están asociados con la presencia de enfermedad arterial coronaria (EAC) y/o restenosis en pacientes con stent coronario. MÉTODOS: En este estudio se genotiparon dos polimorfismos del gen CETP [−971 A/G (rs4783961) y Taq1B A/G (rs708272)] mediante ensayos de 5'exonucleasa TaqMan en 219 pacientes con EAC (66 pacientes con restenosis y 153 sin restenosis), y 607 individuos de control. RESULTADOS: La distribución de polimorfismos fue similar en pacientes con y sin restenosis. Sin embargo, cuando se comparó todo el grupo de pacientes (con y sin restenosis) con controles sanos, bajo el modelo dominante el alelo G del polimorfismo Taq1B A/G se asocia con un mayor riesgo de EAC (OR = 1.48, pCDom = 0.032). De la misma manera, bajo los modelos co-dominante, dominante y aditivo, el alelo A de los polimorfismos −971 A/G se asocia con un mayor riesgo de desarrollar EAC (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0,008 y OR = 1.39, pCAdd = 0.011, respectivamente). Adicionalmente, el desequilibrio de ligamiento mostró que el haplotipo "AG" se asocia con un mayor riesgo de desarrollar EAC (OR = 1.28, p = 0.03). CONCLUSIÓN: En resumen, este estudio demuestra que los polimorfismos CETP Taq1B A/G y CETP −971 A/G están asociados con un mayor riesgo de desarrollar CAD, pero no se observó asociación con restenosis.


Asunto(s)
Proteínas de Transferencia de Ésteres de Colesterol , Enfermedad de la Arteria Coronaria , Proteínas de Transferencia de Ésteres de Colesterol/genética , Enfermedad de la Arteria Coronaria/genética , Genotipo , Humanos , Desequilibrio de Ligamiento , Polimorfismo de Nucleótido Simple , Stents
7.
Cardiol Young ; 21(5): 551-5, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21729507

RESUMEN

BACKGROUND: Congenital cardiac diseases are the most frequent congenital malformations. In adult patients, the mineralisation of the aorta due to cardiovascular disease is very common, but vascular mineralisation in paediatric cardiopathies is a topic less studied. This study shows that children with a complex congenital cardiopathy show a high degree of vascular mineralisation in the ascending aorta. This can be part of the cardiac failure pathophysiology due to congenital cardiopathies. OBJECTIVE: The aim of this study was to determine the presence and degree of vascular mineralisation in samples of the ascending and descending aorta of children with complex congenital cardiopathies. DESIGN: We conducted a cross-sectional study. SUBJECTS: We obtained 34 vascular tissues from the autopsies of 17 children with congenital cardiac disease. METHODS: We used a scanning electron microscope with an energy-dispersive X-ray spectroscopy in order to analyse the vascular tissues. RESULTS: The amount of minerals was two times higher in the ascending aorta than in the descending aorta of children with congenital cardiac disease. CONCLUSIONS: The study provides evidence that vascular mineralisation can start at an early age, and that it is higher in the ascending aorta than in the descending aorta.


Asunto(s)
Aorta Torácica/química , Enfermedades de la Aorta/etiología , Cardiopatías/congénito , Cardiopatías/complicaciones , Minerales/análisis , Preescolar , Estudios Transversales , Humanos , Lactante , Recién Nacido
8.
Arch Cardiol Mex ; 90(2): 142-147, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32897265

RESUMEN

In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Asunto(s)
Vasos Coronarios/cirugía , Diseño de Prótesis , Stents , Animales , Aleaciones de Cromo/química , Enfermedad de la Arteria Coronaria/cirugía , Perros , Fluoroscopía , Humanos , Modelos Animales , Conejos
9.
Arch Cardiol Mex ; 90(2): 163-168, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32459214

RESUMEN

In this paper we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing and mechanic trials we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion and safety. As well as endothelial attachment, thrombogenicity and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion and complete endothelial attach. Also, we obtained a good post-implant balloon withdrawal, functional integrity and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Diseño de Prótesis , Stents , Animales , Modelos Animales de Enfermedad , Perros , Fluoroscopía , Humanos , Conejos
10.
Arch Cardiol Mex ; 88(5): 432-440, 2018 12.
Artículo en Español | MEDLINE | ID: mdl-29706554

RESUMEN

BACKGROUND: Reclassification of a large thrombus burden is an independent predictor of major adverse cardiac events and no-reflow in patients with ST- segment elevation myocardial infarction (STEMI). Patients with a greater residual thrombus burden have worse microvascular dysfunction and greater myocardial damage. METHODS: A retrospective analysis was performed on 833 STEMI patients who underwent primary percutaneous coronary intervention. The final residual thrombus burden was reclassified after the lesion was wired, and a thrombus aspiration or balloon dilatation was performed to restore and stabilise a thrombolysis in myocardial infarction (TIMI) 2-3 flow. Deferred stenting (DEI) was compared with immediate stenting (ISI) group, and the primary outcome was the incidence of no-/slow-reflow (TIMI ≤ 2, or TIMI 3 with myocardial blush grade < 2). RESULTS: Overall, 47 patients (6.8%) had a residual large thrombus burden reclassified. The right coronary artery was the culprit vessel in 34 cases. More patients had coronary ectasia in the DSI group (P=.005). Fewer patients in the DSI had no-/slow-reflow (36% vs. 58%), and the myocardial blush grade 3 was more frequent in the DSI group (P=.005). After repeat coronary angiography in the DSI group, stenting was not performed in 56%, and oral anticoagulation was more frequent in the follow-up (P=.031). Major cardiac adverse events were similar between groups. There was a tendency to better left ventricular function in the DSI group (P=.056). CONCLUSIONS: Deferred stenting may be an efficient option in STEMI patients with a residual large thrombus burden reclassified after achieving a stable TIMI 2-3 flow.


Asunto(s)
Angiografía Coronaria/métodos , Trombosis Coronaria/terapia , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio con Elevación del ST/terapia , Stents , Adulto , Anciano , Anticoagulantes/administración & dosificación , Trombosis Coronaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/fisiopatología , Factores de Tiempo , Función Ventricular Izquierda
11.
Eur J Heart Fail ; 20(2): 199-215, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29280256

RESUMEN

Heart failure (HF) is a complex clinical syndrome with multiple interactions between the failing myocardium and cerebral (dys-)functions. Bi-directional feedback interactions between the heart and the brain are inherent in the pathophysiology of HF: (i) the impaired cardiac function affects cerebral structure and functional capacity, and (ii) neuronal signals impact on the cardiovascular continuum. These interactions contribute to the symptomatic presentation of HF patients and affect many co-morbidities of HF. Moreover, neuro-cardiac feedback signals significantly promote aggravation and further progression of HF and are causal in the poor prognosis of HF. The diversity and complexity of heart and brain interactions make it difficult to develop a comprehensive overview. In this paper a systematic approach is proposed to develop a comprehensive atlas of related conditions, signals and disease mechanisms of the interactions between the heart and the brain in HF. The proposed taxonomy is based on pathophysiological principles. Impaired perfusion of the brain may represent one major category, with acute (cardio-embolic) or chronic (haemodynamic failure) low perfusion being sub-categories with mostly different consequences (i.e. ischaemic stroke or cognitive impairment, respectively). Further categories include impairment of higher cortical function (mood, cognition), of brain stem function (sympathetic over-activation, neuro-cardiac reflexes). Treatment-related interactions could be categorized as medical, interventional and device-related interactions. Also interactions due to specific diseases are categorized. A methodical approach to categorize the interdependency of heart and brain may help to integrate individual research areas into an overall picture.


Asunto(s)
Encéfalo/fisiopatología , Cardiología , Cognición/fisiología , Consenso , Insuficiencia Cardíaca/clasificación , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/fisiología , Sociedades Médicas , Progresión de la Enfermedad , Humanos
12.
Arch. cardiol. Méx ; Arch. cardiol. Méx;93(4): 391-397, Oct.-Dec. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1527715

RESUMEN

Abstract Objective: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. Methods: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. Results: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. Conclusions: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.


Resumen Objetivo: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. Métodos: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. Resultados: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. Conclusiones: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.

13.
Arch. cardiol. Méx ; Arch. cardiol. Méx;92(3): 334-341, jul.-sep. 2022. tab
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1393828

RESUMEN

Abstract Objective: We evaluated whether cholesteryl ester transfer protein (CETP) gene polymorphisms are associated with the presence of coronary artery disease (CAD) and/or restenosis in patients with coronary stent. Methods: Two polymorphisms of the CETP gene [−971 A/G (rs4783961), and Taq1B A/G (rs708272)] were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD (66 patients with restenosis and 153 without restenosis) and 607 control individuals. Results: The distribution of polymorphisms was similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under dominant model, the G allele of the Taq1B A/G polymorphism was associated with increased risk of CAD (odds ratio [OR] = 1.48, pCDom = 0.032). In the same way, under codominant, dominant, and additive models, the A allele of the −971 A/G polymorphisms was associated with an increased risk of developing CAD (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0.008, and OR = 1.39, pCAdd = 0.011, respectively). In addition, the linkage disequilibrium showed that the "AG" haplotype was associated with increased risk of developing CAD (OR = 1.28, p = 0.03). Conclusion: This study demonstrates that CETP Taq1B A/G and CETP −971 A/G polymorphisms are associated with an increased risk of developing CAD, but no association with restenosis was observed.


Resumen Objetivo: Evaluamos si los polimorfismos del gen CETP están asociados con la presencia de enfermedad arterial coronaria (EAC) y/o restenosis en pacientes con stent coronario. Métodos: En este estudio se genotiparon dos polimorfismos del gen CETP [−971 A/G (rs4783961) y Taq1B A/G (rs708272)] mediante ensayos de 5'exonucleasa TaqMan en 219 pacientes con EAC (66 pacientes con restenosis y 153 sin restenosis), y 607 individuos de control. Resultados: La distribución de polimorfismos fue similar en pacientes con y sin restenosis. Sin embargo, cuando se comparó todo el grupo de pacientes (con y sin restenosis) con controles sanos, bajo el modelo dominante el alelo G del polimorfismo Taq1B A/G se asocia con un mayor riesgo de EAC (OR = 1.48, pCDom = 0.032). De la misma manera, bajo los modelos co-dominante, dominante y aditivo, el alelo A de los polimorfismos −971 A/G se asocia con un mayor riesgo de desarrollar EAC (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0,008 y OR = 1.39, pCAdd = 0.011, respectivamente). Adicionalmente, el desequilibrio de ligamiento mostró que el haplotipo "AG" se asocia con un mayor riesgo de desarrollar EAC (OR = 1.28, p = 0.03). Conclusión: En resumen, este estudio demuestra que los polimorfismos CETP Taq1B A/G y CETP −971 A/G están asociados con un mayor riesgo de desarrollar CAD, pero no se observó asociación con restenosis.

14.
Gac. méd. Méx ; Gac. méd. Méx;158(6): 380-386, nov.-dic. 2022. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1430367

RESUMEN

Resumen Introducción: Las bioprótesis de válvulas cardiacas son el estándar de oro para el reemplazo quirúrgico de la válvula aórtica en pacientes seleccionados. Objetivo: Evaluar la seguridad y eficacia de la válvula cardiaca bioprotésica del Instituto Nacional de Cardiología (INC) en humanos. Métodos: Estudio unicéntrico que incluyó 341 pacientes que se sometieron a reemplazo valvular quirúrgico único de válvula aórtica con válvula INC. Resultados: Se realizaron 318 implantes de novo (93 %) y 23 como segunda cirugía (7 %); las puntuaciones STS fueron de 1.4 y 1.8 % y el seguimiento de 42 y 46 meses, respectivamente. No existieron diferencias en las complicaciones ni en la tasa de implantación de marcapasos. Ambos grupos mantuvieron una FEVI normal. Se observó mejoría global en la clase funcional con empeoramiento solo en dos pacientes del grupo de novo. La disfunción de la prótesis INC que ameritó reintervención quirúrgica se observó en ocho pacientes (4.65 %) del grupo de novo versus un paciente (7.69 %) con segunda cirugía. Conclusiones: La válvula cardiaca INC es eficaz y segura, se asocia a baja tasa de complicaciones y mejoría de la clase funcional durante el seguimiento a largo plazo. Se necesitan estudios prospectivos comparativos de esta válvula.


Abstract Introduction: Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients. Objective: To evaluate the safety and efficacy of the of the National Institute of Cardiology (INC) bioprosthetic heart alve of the National Institute of Cardiology (INC) bioprosthetic heart valve in humans. Methods: Single-center study that ncluded 341 patients who underwent single surgical aortic valve replacement with INC heart valve. Results: 318 implants were performed de novo (93%) and 23 as redo surgery (7%); STS scores were 1.4 and 1.8%, and follow-up was for 42 and 46 months, respectively. There were no differences in clinical complications or pacemaker implantation rate. Both groups maintained a normal LVEF. Overall improvement in functional class was observed, with worsening only in two patients of the de novo group. INC prosthesis dysfunction requiring surgical reintervention was observed in eight patients (4.65%) of the de novo group vs. one patient in the redo group. Conclusions: The INC heart valve is efficacious and safe, and is associated with a The INC heart valve is efficacious and safe, and is associated with a low rate of complications and functional class improvement during long-term follow-up. Prospective, comparative studies of this valve are required.

16.
Arch Cardiol Mex ; 75(3): 267-78, 2005.
Artículo en Español | MEDLINE | ID: mdl-16294815

RESUMEN

The use of a synthetic membrane-covered stent has been suggested to overcome some specific lesions in coronary arteries and to solve some potential complications that could arise in any procedure of coronary intervention. A synthetic membrane coronary stent graft (JOSTENT-JOMED) is constituted by a membrane of polytetrafluoroethylene (PTFE), fixed between two thin metallic stents. In this clinical review of our laboratory's experience, the Jostent graft was used in several angiographic circumstances in coronary arteries or in vein grafts. Our clinical experience consists of 17 patients that were treated with placement of PTFE stents for different indications: coronary rupture in two patients; thrombus and degenerative vein grafts in eight patients, coronary aneurysms in four patients, and thrombus in coronary arteries in three more. Our clinical results with this device suggest that its implant is feasible and safe with a clinical success of 100% without complications during in-hospital stay; during the clinical 11 +/- 3 months follow-up, only three patients exhibited major cardiac events. The indication for PTFE stent in vein grafts with degenerative and thrombus lesions has not been determined yet; however, recently, some randomized trials have shown little benefit in this circumstance. On the other side, coronary vessel rupture and coronary aneurysms are currently the most definitive indications.


Asunto(s)
Enfermedad Coronaria/cirugía , Politetrafluoroetileno , Stents , Adulto , Anciano , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/cirugía , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/cirugía , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/cirugía , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Seguridad , Factores de Tiempo , Resultado del Tratamiento
17.
Rev. invest. clín ; Rev. invest. clín;72(1): 19-24, Jan.-Feb. 2020. tab
Artículo en Inglés | LILACS | ID: biblio-1251830

RESUMEN

ABSTRACT Background: Previous studies have shown an association between polymorphisms of the BAT1-NF-κB inhibitor-like-1 (NFKBIL1)-LTA genomic region and susceptibility to myocardial infarction and acute coronary syndrome (ACS). Objective: The objective of the study was to study the role of three polymorphisms in the BAT1, NFKBIL1, and LTA genes on the susceptibility or protection against ACS; we included a group of cases-controls from Central Mexico. Methods: The BAT1 rs2239527C/G, NFKBIL1 rs2071592T/A, and LTA rs1800683G/A polymorphisms were genotyped using a 5' TaqMan assay in a group of 625 patients with ACS and 617 healthy controls. Results: Under a recessive model, the BAT1 -23C/G (rs2239527) polymorphism showed an association with protection against ACS (odds ratio = 0.56, and p-corrected = 0.019). In contrast, the genotype and allele frequencies of the NFKBIL1 rs2071592T/A and LTA rs1800683G/A polymorphisms were similar between ACS patients and controls and no association was identified. Conclusion: Our data suggest an association between the BAT1 -23C/G polymorphism and protection against ACS in Mexican patients.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , ARN Helicasas DEAD-box/genética , Síndrome Coronario Agudo/genética , Infarto del Miocardio/genética , Estudios de Casos y Controles , Linfotoxina-alfa/genética , Predisposición Genética a la Enfermedad , Polimorfismo de Nucleótido Simple , Proteínas Adaptadoras Transductoras de Señales/genética , Frecuencia de los Genes , Genotipo , México
18.
Rev. invest. clín ; Rev. invest. clín;72(1): 32-36, Jan.-Feb. 2020. graf
Artículo en Inglés | LILACS | ID: biblio-1251832

RESUMEN

ABSTRACT Background: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. Methods: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. Presentation of Cases: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. Conclusions: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Asunto(s)
Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Diseño de Prótesis , Stents , Isquemia Miocárdica/cirugía , Proyectos Piloto , Estudios de Seguimiento , Ultrasonografía , Resultado del Tratamiento , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/diagnóstico por imagen , México
19.
Gac. méd. Méx ; Gac. méd. Méx;156(4): 276-282, Jul.-Aug. 2020. graf
Artículo en Inglés | LILACS | ID: biblio-1249911

RESUMEN

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Asunto(s)
Animales , Masculino , Femenino , Conejos , Paclitaxel/administración & dosificación , Sirolimus/administración & dosificación , Stents Liberadores de Fármacos , Diseño de Prótesis , Espectrofotometría Infrarroja , Porcinos , Estudios de Seguimiento , Modelos Animales de Enfermedad , Microscopía
20.
Arch. cardiol. Méx ; Arch. cardiol. Méx;90(2): 142-147, Apr.-Jun. 2020. graf
Artículo en Inglés | LILACS | ID: biblio-1131023

RESUMEN

Abstract In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 μm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


Resumen En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 μm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Asunto(s)
Humanos , Animales , Perros , Conejos , Diseño de Prótesis , Stents , Vasos Coronarios/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Fluoroscopía , Aleaciones de Cromo/química , Modelos Animales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA