1.
J Biomech Eng ; 139(5)2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28267190

RESUMEN

Acute mechanical damage and the resulting joint contact abnormalities are central to the initiation and progression of post-traumatic osteoarthritis (PTOA). Study of PTOA is typically performed in vivo with replicate animals using artificially induced injury features. The goal of this work was to measure changes in a joint contact stress in the knee of a large quadruped after creation of a clinically realistic overload injury and a focal cartilage defect. Whole-joint overload was achieved by excising a 5-mm wedge of the anterior medial meniscus. Focal cartilage defects were created using a custom pneumatic impact gun specifically developed and mechanically characterized for this work. To evaluate the effect of these injuries on joint contact mechanics, Tekscan (Tekscan, Inc., South Boston, MA) measurements were obtained pre-operatively, postmeniscectomy, and postimpact (1.2-J) in a nonrandomized group of axially loaded cadaveric sheep knees. Postmeniscectomy, peak contact stress in the medial compartment is increased by 71% (p = 0.03) and contact area is decreased by 35% (p = 0.001); the center of pressure (CoP) shifted toward the cruciate ligaments in both the medial (p = 0.004) and lateral (p = 0.03) compartments. The creation of a cartilage defect did not significantly change any aspect of contact mechanics measured in the meniscectomized knee. This work characterizes the mechanical environment present in a quadrupedal animal knee joint after two methods to reproducibly induce joint injury features that lead to PTOA.


Asunto(s)
Cartílago/lesiones , Traumatismos de la Rodilla/etiología , Articulación de la Rodilla , Fenómenos Mecánicos , Meniscectomía/efectos adversos , Animales , Fenómenos Biomecánicos , Ovinos , Estrés Mecánico
2.
Clin Orthop Relat Res ; 471(2): 527-36, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23008021

RESUMEN

BACKGROUND: Hypothesized risk factors for fracture of ceramic liners include impingement, edge-loading, and cup malpositioning. These risk factors are similar to those for generation of stripe wear. However, it is unclear whether the biomechanical conditions contributing to stripe wear generation also increase the risk for ceramic liner fracture QUESTIONS/PURPOSES: We asked whether (1) head stripe wear propensity; and (2) cup orientation would correlate with alumina liner fracture risk for instances of normal and elevated body weight. METHODS: An eXtended Finite Element Method (XFEM) model was developed to investigate these mechanisms. Liner fracture risk for 36-mm alumina bearings was studied by simulating two fracture-prone motions: stooping and squatting. Twenty-five distinct cup orientations were considered with variants of both acetabular inclination and anteversion. Four separate body mass indices were considered: normal (25 kg/m(2)) and three levels of obesity (33, 42, and 50 kg/m(2)). Material properties were modified to simulate alumina with and without the presence of dispersed microflaws. The model was validated by corroboration with two previously published ceramic liner fracture studies. RESULTS: Of 200 XFEM simulations with flaw-free alumina, fracture occurred in eight instances, all of them involving obesity. Each of these occurred with cups in ≤ 37° inclination and in 0° anteversion. For 200 corresponding simulations with microflawed alumina, fracture propensity was greatest for cups with higher (edge loading-associated) scraping wear. Fracture risk was greatest for cups with lower inclination (average 42° for fractured cases versus 48° for nonfractured cases) and lower anteversion (9° versus 20°). CONCLUSIONS: Fracture propensity for 36-mm liners was elevated for cups with decreased anteversion and/or inclination and under conditions of patient obesity. CLINICAL RELEVANCE: Factors causing stripe wear, including obesity and cup malpositioning, also involve increased risk of ceramic liner fracture and merit heightened concern.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Obesidad/complicaciones , Falla de Prótesis/etiología , Acetábulo/cirugía , Cerámica , Simulación por Computador , Análisis de Falla de Equipo , Humanos , Modelos Teóricos , Diseño de Prótesis , Factores de Riesgo
3.
Clin Orthop Relat Res ; 471(3): 971-80, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22907474

RESUMEN

BACKGROUND: Obesity has reached epidemic proportions in the United States. Recently, obesity, especially morbid obesity, has been linked to increased rates of dislocation after THA. The reasons are unclear. Soft tissue engagement caused by increased thigh girth has been proposed as a possible mechanism for decreased joint stability. QUESTIONS/PURPOSES: We asked (1) whether thigh soft tissue impingement could decrease THA stability, and if so, at what level of BMI this effect might become evident; and (2) how THA construct factors (eg, head size, neck offset, cup abduction) might affect stability in the morbidly obese. METHODS: The obesity effect was explored by augmenting a physically validated finite element model of a total hip construct previously comprising just implant hardware and periarticular (capsular) soft tissue. The model augmentation involved using anatomic and anthropometric data to include graded levels of increased thigh girth. Parametric computations were run to assess joint stability for two head sizes (28 and 36 mm), for normal versus high neck offset, and for multiple cup abduction angles. RESULTS: Thigh soft tissue impingement lowered the resistance to dislocation for BMIs of 40 or greater. Dislocation risk increased monotonically above this threshold as a function of cup abduction angle, independent of hardware impingement events. Increased head diameter did not substantially improve joint stability. High-offset necks decreased the dislocation risk. CONCLUSIONS: Excessive obesity creates conditions that compromise stability of THAs. Given such conditions, our model suggests reduced cup abduction, high neck offset, and full-cup coverage would reduce the risks of dislocation events.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Luxación de la Cadera/etiología , Articulación de la Cadera/cirugía , Prótesis de Cadera , Inestabilidad de la Articulación/etiología , Obesidad Mórbida/complicaciones , Falla de Prótesis , Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos , Índice de Masa Corporal , Simulación por Computador , Análisis de Elementos Finitos , Luxación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Modelos Anatómicos , Obesidad Mórbida/diagnóstico , Obesidad Mórbida/fisiopatología , Diseño de Prótesis , Radiografía , Factores de Riesgo , Insuficiencia del Tratamiento
4.
J Arthroplasty ; 27(4): 520-6, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21855277

RESUMEN

Although improvements in materials engineering have greatly reduced fracture rates in ceramic femoral heads, concerns still exist for liners. Ceramics are vulnerable to fracture due to impact and from stress concentrations (point and line loading) such as those associated with impingement-subluxation. Thus, ceramic cup fracture propensity is presumably very sensitive to surgical cup positioning. A novel fracture mechanics finite element formulation was developed to identify cup orientations most susceptible to liner fracture propagation for several impingement-prone patient maneuvers. Other factors being equal, increased cup inclination and increased anteversion were found to elevate fracture risk. Squatting, stooping, and leaning shoe-tie maneuvers were associated with the highest fracture risk. These results suggest that fracture risk can be reduced by surgeons' decreasing cup abduction and by patients' avoiding of specific activities.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica , Pinzamiento Femoroacetabular/complicaciones , Análisis de Elementos Finitos , Luxación de la Cadera/complicaciones , Prótesis de Cadera , Falla de Prótesis , Fenómenos Biomecánicos , Simulación por Computador , Análisis de Falla de Equipo , Humanos , Modelos Biológicos , Movimiento , Postura , Factores de Riesgo
5.
J Arthroplasty ; 27(7): 1316-1323.e2, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22266047

RESUMEN

The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos , Necrosis de la Cabeza Femoral/cirugía , Luxación Congénita de la Cadera/cirugía , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Acetábulo/diagnóstico por imagen , Adulto , Artroplastia de Reemplazo de Cadera/instrumentación , Falla de Equipo , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Falla de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
6.
Clin Orthop Relat Res ; 469(2): 454-63, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20953853

RESUMEN

BACKGROUND: Impingement events, in addition to their role immediately proximate to frank dislocation, hold the potential to damage new-generation hard-on-hard bearings as a result of the relatively unforgiving nature of the materials and designs. Because of the higher stiffness and tighter design tolerances of metal-on-metal and ceramic implants, surgical positioning plausibly has become even more important. QUESTIONS/PURPOSES: We asked (1) whether, and under what cup orientation conditions, hard-on-hard impingements might challenge implant material failure strength; and (2) whether particle generation propensity at impingement and egress sites would show similar dependence on cup orientation. METHODS: Realistic computational simulations were enabled by multistage finite element analyses, addressing both global construct motion and loading, and focal stress concentrations at neck impingement and rim egress sites. The global model, validated by a cadaveric simulation in a servohydraulic hip simulator, included both hardware components and advanced anisotropic capsule characterization. Parametric computational runs explored the effect of cup orientation for both ceramic-on-ceramic and metal-on-metal bearing couples for two distinct motion sequences associated with dislocation. RESULTS: Stress concentrations from impingement increased nearly linearly with increased cup tilt and with cup anteversion. In some situations, peak values of stress approached or exceeded 1 GPa, levels challenging the yield strength of cobalt-chromium implants, and potentially the fracture strength of ceramics. The tendency for impingement events to generate debris, indexed in terms of a new scraping severity metric, showed orientation dependences similar to that for bulk material failure. CONCLUSIONS: Damage propensity arising from impingement events in hard total hip bearings is highly orientation-dependent.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Luxación de la Cadera/etiología , Articulación de la Cadera/cirugía , Prótesis de Cadera , Falla de Prótesis , Fenómenos Biomecánicos , Simulación por Computador , Análisis de Elementos Finitos , Luxación de la Cadera/patología , Luxación de la Cadera/fisiopatología , Articulación de la Cadera/patología , Articulación de la Cadera/fisiopatología , Humanos , Diseño de Prótesis , Estrés Mecánico
7.
Clin Orthop Relat Res ; 467(7): 1885-97, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19399565

RESUMEN

Aseptic loosening attributable to wear-related osteolysis historically has been the predominant cause of failure in THA. Advances in low-wear bearing couples show great promise to substantially reduce this long-standing problem. However, there always has been striking variability in wear rate in any given cohort of patients who are similarly implanted, with some individuals typically experiencing near order-of-magnitude elevations above group mean. Third-body wear is likely a major contributor to many of these most osteolysis-prone outliers. For the patients affected, third-body effects may obviate many of the gains otherwise achieved by contemporary bearing surface improvements. Toward heightening visibility in terms of consequences for patients, this review paper summarizes an interrelated series of investigations quantifying construct level manifestations of third-body wear. Long-term followup of a unique group of patients with elevated third-body challenge shows statistically significant and clinically important wear-rate increases. A series of finite element models, validated physically, shows the linkage of location of third-body damage with variability of volumetric wear-rate acceleration and shows the effects of various implant factors, surgeon factors, and patient factors in the presence of third-body challenge. Finally, a mechanism for third-body debris access to wear-critical locations on the bearing surface is identified analytically and corroborated in laboratory experiments and implant retrievals.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Distinciones y Premios , Prótesis de Cadera/efectos adversos , Osteólisis , Falla de Prótesis , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Osteólisis/diagnóstico por imagen , Osteólisis/etiología , Osteólisis/fisiopatología , Radiografía
8.
J Biomech ; 41(10): 2090-6, 2008 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-18561936

RESUMEN

In total joint arthroplasty, third body particle access to the articulating surfaces results in accelerated wear. Hip joint subluxation is an under-recognized means by which third body particles could potentially enter the otherwise closely conforming articular bearing space. The present study was designed to test the hypothesis that, other factors being equal, even occasional events of femoral head subluxation greatly increase the number of third body particles that enter the bearing space and become embedded in the acetabular liner, as compared to level-walking cycles alone. Ten metal-on-polyethylene hip joint head-liner pairs were tested in a multi-axis joint motion simulator, with CoCrMo third body particles added to the synovial fluid analog. All component pairs were tested for 2h of level walking; half were also subjected to 20 intermittent subluxation events. The number and location of embedded particles on the acetabular liners were then determined. Subluxation dramatically increased the number of third body particles embedded in the acetabular liners, and it considerably increased the amount of scratch damage on the femoral heads. Since both third body particles and subluxation frequently occur in contemporary total hip arthroplasty, their potent synergy needs to be factored prominently into strategies to minimize wear.


Asunto(s)
Prótesis de Cadera , Diseño de Prótesis/métodos , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera , Fenómenos Biomecánicos , Diseño de Equipo , Cabeza Femoral/patología , Articulación de la Cadera/cirugía , Humanos , Metales/química , Microscopía Electrónica de Rastreo , Ortopedia/métodos , Polietileno/química , Falla de Prótesis , Líquido Sinovial/metabolismo
9.
J Biomech ; 41(10): 2197-205, 2008 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-18561937

RESUMEN

Cryoinsult-induced osteonecrosis (ON) in the emu femoral head provides a unique opportunity to systematically explore the pathogenesis of ON in an animal model that progresses to human-like femoral head collapse. Among the various characteristics of cryoinsult, the maximally cold temperature attained is one plausible determinant of tissue necrosis. To identify the critical isotherm required to induce development of ON in the cancellous bone of the emu femoral head, a thermal finite element (FE) model of intraoperative cryoinsults was developed. Thermal material property values of emu cancellous bone were estimated from FE simulations of cryoinsult to emu cadaver femora, by varying model properties until the FE-generated temperatures matched corresponding thermocouple measurements. The resulting FE model, with emu bone-specific thermal properties augmented to include blood flow effects, was then used to study intraoperatively performed in vivo cryoinsults. Comparisons of minimum temperatures attained at FE nodes corresponding to the three-dimensional histologically apparent boundary of the region of ON were made for six experimental cryoinsults. Series-wide, a critical isotherm of 3.5 degrees C best corresponded to the boundary of the osteonecrotic lesions.


Asunto(s)
Necrosis de la Cabeza Femoral/patología , Cabeza Femoral/patología , Osteonecrosis/patología , Animales , Fenómenos Biomecánicos , Huesos/metabolismo , Dromaiidae , Cabeza Femoral/fisiopatología , Necrosis de la Cabeza Femoral/fisiopatología , Análisis de Elementos Finitos , Fluoroscopía/métodos , Humanos , Modelos Biológicos , Modelos Teóricos , Estrés Mecánico , Temperatura , Factores de Tiempo
10.
J Biomech ; 41(4): 770-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18206892

RESUMEN

The emu is a large, (bipedal) flightless bird that potentially can be used to study various orthopaedic disorders in which load protection of the experimental limb is a limitation of quadrupedal models. An anatomy-based analysis of normal emu walking gait was undertaken to determine hip contact forces for comparison with human data. Kinematic and kinetic data captured for two laboratory-habituated emus were used to drive the model. Muscle attachment data were obtained by dissection, and bony geometries were obtained by CT scan. Inverse dynamics calculations at all major lower-limb joints were used in conjunction with optimization of muscle forces to determine hip contact forces. Like human walking gait, emu ground reaction forces showed a bimodal distribution over the course of the stance phase. Two-bird averaged maximum hip contact force was approximately 5.5 times body weight, directed nominally axially along the femur. This value is only modestly larger than optimization-based hip contact forces reported in literature for humans. The interspecies similarity in hip contact forces makes the emu a biomechanically attractive animal in which to model loading-dependent human orthopaedic hip disorders.


Asunto(s)
Dromaiidae/fisiología , Articulación de la Cadera/fisiología , Fuerza Muscular/fisiología , Caminata/fisiología , Animales , Fenómenos Biomecánicos , Peso Corporal/fisiología , Dromaiidae/anatomía & histología , Marcha/fisiología , Articulación de la Cadera/anatomía & histología , Humanos , Masculino , Modelos Animales
11.
J Orthop Res ; 25(1): 30-43, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17019701

RESUMEN

Wear rate and wear direction vary considerably within total hip arthroplasty (THA) patient cohorts. Third body effects and wide-ranging differences in patient activity levels are two factors suspected of contributing to wear variability. A sliding-distance-coupled contact finite element formulation was used to test the hypothesis that nonidentical duty cycles (differing activities, or change of third body challenge) produce accelerations in polyethylene wear. Effects of nonidentical duty cycles, time-variant femoral head roughening, and outlier gait inputs were investigated. Without femoral head roughening, combination walk/stair-climb wear simulations did not result in appreciably higher volumetric wear than a walk-only simulation, but when a roughened zone was included, walk/stair-climb volumetric wear increased by approximately 57% above that of a similarly roughened walk-only simulation. To investigate time-variant femoral head roughening, wear simulations were begun with femoral head roughening at one location on the femoral head, switching to another location halfway through the simulation. Results varied depending on roughening sites, but cases of substantial increase in wear involved a transient jump in wear rate shortly after the change of head roughening location. Outlier duty cycles were simulated by increasing or decreasing the joint contact force and range of motion inputs, to levels at the 97.5th and 2.5th percentiles of a population of normal subjects. The resulting wear showed an increase or decrease closely proportional to the percentage by which each input (force or range of motion) was changed.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Ensayo de Materiales , Polietilenos , Falla de Prótesis , Fenómenos Biomecánicos , Cabeza Femoral , Humanos , Ensayo de Materiales/métodos
12.
J Biomech ; 40(8): 1676-85, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17400230

RESUMEN

Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the closely conforming articulating surfaces of the joint is not well understood. We hypothesize that one such mechanism is from convective fluid transport during subluxation of the total hip joint. To test this hypothesis, a three-dimensional (3D) computational fluid dynamics (CFD) model was developed and validated, to quantify fluid ingress into the bearing space during a leg-cross subluxation event. The results indicated that extra-articular joint fluid could be drawn nearly to the pole of the cup with even very small separations of the femoral head (<0.60mm). Debris suspended near the equator of the cup at the site of maximum fluid velocity just before the subluxation began could be transported to within 11 degrees from the cup pole. Larger head diameters resulted in increased fluid velocity at all sites around the entrance to the gap compared to smaller head sizes, with fluid velocity being greatest along the anterosuperolateral cup edge, for all head sizes. Fluid pathlines indicated that suspended debris would reach similar angular positions in the bearing space regardless of head size. Increased inset of the femoral head into the acetabular cup resulted both in higher fluid velocity and in transport of third-body debris further into the bearing space.


Asunto(s)
Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/fisiopatología , Luxación de la Cadera/etiología , Luxación de la Cadera/fisiopatología , Articulación de la Cadera/fisiopatología , Prótesis de Cadera/efectos adversos , Líquido Sinovial , Acetábulo/fisiopatología , Simulación por Computador , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Cabeza Femoral/fisiopatología , Humanos , Modelos Biológicos , Propiedades de Superficie
13.
Iowa Orthop J ; 27: 52-7, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17907430

RESUMEN

It is difficult to study the deformation of articular cartilage because it is an inhomogenous material with depth dependent constituents. In many experimental studies, cartilage is assumed to behave homogeneously and is subjected to only static or quasi-static loads. In this study, a thick walled, mechanically active culture device (TRIAX) was used to apply cyclic loading to cartilage explants at physiological stress levels. An arthroscope was fitted into the wall of the TRIAX to monitorand record the cyclic compressive behavior of the cartilage and to measure depth dependent cartilage strains. A common concern with arthroscopy systems is that the images obtained are radially distorted about a central point ("fisheye" view); therefore it is necessary to correct this distortion in order to accurately quantify distances between objects within the images. To do this, an algorithm was developed which used a calibration pattern to create an image transform. Digital video of the cyclic cartilage compression was recorded, and the distortion algorithm was applied to the images to measure the cartilage as it deformed. This technique will provide valuable and practical insight into cartilage mechanics and viability (via calcein AM-stained chondrocytes) during multiday cyclic loading of living cartilage explants. The implementation of an arthroscopy system provides the advantage of bringing microscope-level resolution into a cartilage compression device to allow for digital visualization of the entire explant at the whole-tissue level.


Asunto(s)
Artroscopía , Cartílago Articular/fisiología , Algoritmos , Calibración , Elasticidad , Humanos , Óptica y Fotónica , Estrés Mecánico , Grabación en Video
14.
Acta Bioeng Biomech ; 19(4): 103-108, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29507427

RESUMEN

PURPOSE: Estimation of hip joint loading is fundamental for understanding joint function, injury and disease. To predict patientspecific hip loading, a musculoskeletal model must be adapted to the patient's unique geometry. By far the most common and cost effective clinical images are whole pelvis plain radiographs. This study compared the accuracy of anisotropic and isotropic scaling of musculoskeletal model to hip joint force prediction by taking patient-specific bone geometry from standard anteroposterior radiograms. METHODS: 356 hips from 250 radiograms of adult human pelvis were analyzed. A musculoskeletal model was constructed from sequential images of the Visible Human Male. The common body position of one-legged stance was substituted for the midstance phase of walking. Three scaling methods were applied: a) anisotropic scaling by interhip separation, ilium height, ilium width, and lateral and inferior position of the greater trochanter, b) isotropic scaling by pelvic width and c) isotropic scaling by interhip separation. Hip joint force in one-legged stance was estimated by inverse static model. RESULTS: Isotropic scaling affects all proportions equally, what results in small difference in hip joint reaction force among patients. Anisotropic hip scaling increases variation in hip joint force among patients considerably. The difference in hip joint force estimated by isotropic and anisotropic scaling may surpass patient's body weight. CONCLUSIONS: Hip joint force estimated by isotropic scaling depends mostly on reference musculoskeletal geometry. Individual's hip joint reaction force estimation could be improved by including additional bone geometrical parameters in the scaling method.


Asunto(s)
Articulación de la Cadera/fisiología , Modelos Biológicos , Postura/fisiología , Adulto , Anisotropía , Fenómenos Biomecánicos , Humanos , Masculino , Valores de Referencia
15.
Artículo en Inglés | MEDLINE | ID: mdl-28203112

RESUMEN

BACKGROUND: Bone contusions are frequently encountered in magnetic resonance imaging (MRI) evaluation of knee anterior cruciate ligament (ACL) injuries. Their role as indicators of injury severity remains unclear, primarily due to indeterminate levels of joint injury forces and to a lack of preinjury imaging. PURPOSE: The purpose of this study was to 1) quantify bone contusion pathogenesis following traumatic joint injuries using fixed imaging follow-ups, and 2) assess the feasibility of using longitudinal bone contusion volumes as an indicator of knee injury severity. STUDY DESIGN: Prospective sequential MRI follow-ups of a goat cohort exposed to controlled stifle trauma in vivo were compared to parallel clinical MRI follow-ups of a human ACL tear patient series. METHODS: Reproducible cartilage impact damage of various energy magnitudes was applied in a survival goat model, coupled with partial resection of anterior portions of medial menisci. Both emulate injury patterns to the knee osteochondral structures commonly encountered in human ACL injury imaging as well as instability from resultant ligament laxity. Longitudinal clinical MRI sequences portrayed stifle bone contusion evolution through 6 months after the inciting event. RESULTS: In the first 2 weeks, biological response variability dominated the whole-joint response with no apparent correlation to trauma severity. Control goats subjected to partial meniscectomy alone exhibited minimal bone response. Thereafter, 0.6 J impact bone contusions portrayed a faster rate of resolution than those induced by 1.2 J cartilage impacts. CONCLUSION: Bone contusion sizes combined with time of persistence are likely better measures of joint injury severity than isolated bone contusion volume.

16.
J Orthop Res ; 35(3): 515-523, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27509320

RESUMEN

Two categories of joint overloading cause post-traumatic osteoarthritis (PTOA): single acute traumatic loads/impactions and repetitive overloading due to incongruity/instability. We developed and refined three classes of complementary models to define relationships between joint overloading and progressive cartilage loss across the spectrum of acute injuries and chronic joint abnormalities: explant and whole joint models that allow probing of cellular responses to mechanical injury and contact stresses, animal models that enable study of PTOA pathways in living joints and pre-clinical testing of treatments, and patient-specific computational models that define the overloading that causes OA in humans. We coordinated methodologies across models so that results from each informed the others, maximizing the benefit of this complementary approach. We are incorporating results from these investigations into biomathematical models to provide predictions of PTOA risk and guide treatment. Each approach has limitations, but each provides opportunities to elucidate PTOA pathogenesis. Taken together, they help define levels of joint overloading that cause cartilage destruction, show that both forms of overloading can act through the same biologic pathways, and create a framework for initiating clinical interventions that decrease PTOA risk. Considered collectively, studies extending from explants to humans show that thresholds of joint overloading that cause cartilage loss can be defined, that to at least some extent both forms of joint overloading act through the same biologic pathways, and interventions that interrupt these pathways prevent cartilage damage. These observations suggest that treatments that decrease the risk of all forms of OA progression can be discovered. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:515-523, 2017.


Asunto(s)
Modelos Animales de Enfermedad , Articulaciones/lesiones , Modelos Biológicos , Osteoartritis/etiología , Heridas y Lesiones/complicaciones , Animales , Humanos
17.
J Bone Joint Surg Am ; 88(7): 1481-5, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16818973

RESUMEN

UNLABELLED: The current study was performed to determine the status, at a minimum of twenty-five years, of a prospective, single-surgeon series of patients treated with primary Charnley total hip arthroplasty with a contemporary femoral cementing technique that included use of a distal cement plug and a retrograde cement-delivery system. Since our review at a minimum of twenty years postoperatively, two primary total hip prostheses were revised (one because of acetabular loosening, and one because of femoral loosening). Of the original cohort of 357 hips (320 patients), ten (2.8%) had revision of the femoral stem because of aseptic loosening. Forty-nine patients (fifty-two hips, 14.6%) who had been in the initial study group were still living at the time of the present review. Five hips (10%) in living patients had required a femoral revision because of aseptic loosening. Including those that were revised, eight femoral components (17%) in living patients were seen to be loose radiographically. Although this study demonstrates the remarkable durability of the femoral fixation obtained with the polished flatback Charnley prosthesis and the contemporary cementing technique, there was some deterioration of the results with time. These results provide a standard for comparison with cementless fixation after hips treated with that technique have been followed for a similar duration. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementación/métodos , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Factores de Tiempo , Resultado del Tratamiento
18.
J Biomech ; 39(7): 1208-16, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-15894322

RESUMEN

A computational model was developed to identify the sites of third body particle embedment in a total hip acetabular component surface that are most problematic in terms of roughening the overpassing regions of the femoral head counterface, leading in turn to most severely accelerated polyethylene wear. The analytical approach used was to calculate loci of acetabular sites that, during the gait cycle, overpass previously documented regions of kinetically most critical femoral head roughening. Instantaneous local contact stress and sliding distance were postulated as factors contributing to the severity of the femoral head scratching/roughening which would be expected, due to otherwise-similar particles embedded along each such acetabular overpass locus. The computational results showed that the location of debris embedment was a potent determinant of the amount of polyethylene wear acceleration expected. The data also showed that the supero-lateral aspect of the acetabular cup is consistently and by far the most problematic area for third body particle embedment.


Asunto(s)
Acetábulo/fisiopatología , Análisis de Falla de Equipo/métodos , Cabeza Femoral/fisiopatología , Prótesis de Cadera/efectos adversos , Inestabilidad de la Articulación/fisiopatología , Modelos Biológicos , Polietileno/química , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Simulación por Computador , Diseño Asistido por Computadora , Interpretación Estadística de Datos , Elasticidad , Cabeza Femoral/cirugía , Análisis de Elementos Finitos , Humanos , Inestabilidad de la Articulación/etiología , Cadenas de Markov , Ensayo de Materiales , Movimiento (Física) , Falla de Prótesis , Estrés Mecánico , Propiedades de Superficie
19.
J Biomech ; 39(5): 885-93, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16488227

RESUMEN

Constrained acetabular liners are utilized to deal with the infrequent but devastating problem of recurrent dislocation. While an encouraging treatment of last resort, the clinical performance of contemporary constrained liners has been somewhat mixed. There are multiple factors contributing to this variability, one of which is the limited understanding of the intrinsic mechanical characteristics of these specialty devices. To address this issue, a three-dimensional, materially nonlinear, multi-surface contact finite element model of a representative constrained liner was created. The model was physically validated, and then used for parametric testing to explore the effects of individual design features. The model was exercised for both intra-operative assembly and lever-out dislocation. It was found that the coefficient of friction between the femoral head and the liner substantially affected both the force required to seat the femoral head into the liner during assembly, and the peak moment resisting dislocation (226% increase in assembly force for friction coefficients of 0.2 versus 0.0; 49% reduction in dislocation moment for friction coefficients of 0.013 versus 0.135). As expected, the cup opening radius also had a dominant effect on both maneuvers: decreasing the opening radius from 13.9 to 13.6 mm increased assembly force by 506 N and increased the dislocation moment by over 3.5 N-m, whereas the influence of other design parameters was much more modest.


Asunto(s)
Acetábulo/fisiopatología , Acetábulo/cirugía , Diseño Asistido por Computadora , Análisis de Falla de Equipo/métodos , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/cirugía , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Simulación por Computador , Análisis de Elementos Finitos , Fricción , Humanos , Membranas Artificiales , Modelos Biológicos , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico , Resultado del Tratamiento
20.
J Biomech ; 39(4): 617-26, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-15927189

RESUMEN

Cartilage deformation demonstrates viscoelastic behavior due to its unique structure. However, nearly all contact studies investigating incongruity-associated changes in cartilage surface stresses have been static tests. These tests have consistently measured only modest increases in contact stresses, even with large incongruities. In this study, an experimental approach measuring real-time contact stresses in human cadaveric ankles during quasi-physiologic motion and loading was used to determine how stepoff incongruities of the distal tibia affected contact stresses and contact stress gradients. Peak instantaneous contact stresses, in ankles with stepoffs between 1.0 and 4.0mm of the anterolateral articular surface, increased by between 2.3 x and 3.0 x compared to the corresponding intact ankle values. Peak instantaneous contact stress gradients in stepoff configurations increased by between 1.9 x and 2.6 x the corresponding intact configuration values. Anatomic reduction of the displaced fragment restored intact contact stresses and contact stress gradients. Intact and anatomic configurations demonstrated a heterogeneous population of low-magnitude, randomly oriented contact stress gradient vectors in contrast to high-magnitude, preferentially oriented gradients in stepoff configurations. Peak instantaneous contact stresses may be important pathomechanical determinants of post-traumatic arthritis. Abnormal contact stress gradients could cause regional pathological disturbances in cartilage stress and interstitial fluid distribution. Measuring contact stresses and contact stress gradients during motion allowed potential incongruity-associated pathologic changes in loading that occur over the complete motion cycle to be investigated.


Asunto(s)
Articulación del Tobillo/fisiología , Locomoción/fisiología , Soporte de Peso/fisiología , Cadáver , Humanos , Técnicas In Vitro , Cinética , Estrés Mecánico , Propiedades de Superficie