Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-26479445

RESUMEN

A simple, fast, costless, sensitive and selective method of resonance light scattering coupled with HPLC was established for the determination of 6-mercaptopurine in human urine sample. In a Britton-Robinson buffer solution of pH5.5, the formation of coordination complex between 6-mercaptopurine and metal palladium (II) led to enhance the RLS intensity of the system. The RLS signal was detected by fluorescence detector at λ(ex)=λ(em)=315 nm. The analytical parameters were provided by the coupled system, the linear of 6-mercaptopurine response from 0.0615 to 2.40 µg L(-1) and the limit of detection (S/N=3) was 0.05 µg L(-1). The presented method has been applied to determine 6-mercaptopurine in human urine samples which obtained satisfactory results. Moreover, the reaction mechanism and possible reasons for enhancement of RLS were fully discussed.


Asunto(s)
Antimetabolitos Antineoplásicos/orina , Cromatografía Líquida de Alta Presión/métodos , Dispersión Dinámica de Luz/métodos , Mercaptopurina/orina , Cromatografía Líquida de Alta Presión/economía , Cromatografía Líquida de Alta Presión/instrumentación , Dispersión Dinámica de Luz/economía , Dispersión Dinámica de Luz/instrumentación , Diseño de Equipo , Humanos , Límite de Detección , Modelos Moleculares
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 147: 178-84, 2015 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-25840026

RESUMEN

Herein, a Rayleigh light-scattering (RLS) detection method combined with high performance liquid chromatograph (HPLC) without any post-column probe was developed for the separation and determination of three α1-adrenoceptor antagonists. The quantitative analysis is benefiting from RLS signal enhancement upon addition of methanol which induced molecular aggregation to form an hydrophobic interface between aggregates and water that produce a sort of superficial enhanced scattering effect. A good chromatographic separation among the compounds was achieved using a Gemini 5u C18 reversed phase column (250 mm × 4.6 mm; 4 µm) with a mobile phase consisting of methanol and ammonium acetate-formic acid buffer solution (25 mM; pH=3.0) at the flow rate of 0.7 mL min(-1). The RLS signal was monitored at λex=λem=354 nm. A limit of detection (LOD) of 0.065-0.70 µg L(-1) was reached and a linear range was found between peak height and concentration in the range of 0.75-15 µg L(-1) for doxazosin mesylate (DOX), 0.075-3.0 µg L(-1) for prazosin hydrochloride (PRH), and 0.25-5 µg L(-1) for terazosin hydrochloride (TEH), with linear regression coefficients all above 0.999. Recoveries from spiked urine samples were 88.4-99.0% which is within acceptable limits. The proposed method is convenient, reliable and sensitive which has been used successfully in human urine samples.


Asunto(s)
Antagonistas Adrenérgicos alfa/orina , Cromatografía Líquida de Alta Presión/métodos , Doxazosina/orina , Dispersión Dinámica de Luz/métodos , Prazosina/análogos & derivados , Prazosina/orina , Antagonistas Adrenérgicos alfa/análisis , Dimerización , Doxazosina/análisis , Humanos , Enlace de Hidrógeno , Límite de Detección , Modelos Moleculares , Prazosina/análisis
3.
Anal Chim Acta ; 630(1): 101-6, 2008 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-19068331

RESUMEN

A new reversed-phase high performance liquid chromatography with resonance Rayleigh scattering detection (HPLC-RRS) was developed for simultaneous separation and determination of four tetracycline antibiotics (TCs). A good chromatographic separation among the compounds was achieved using a Synergi Fusion-RP column (150 mm x 4.6 mm; 4 microm) and a mobile phase consisting of methanol-acetonitrile-oxalic acid (5mM) at the flow rate of 0.8 mLmin(-1). Column temperature was 30 degrees C. The RRS signal was detected at lambda(ex)=lambda(em)=370 nm. The recoveries of sample added standard ranged from 95.3% to 103.5%, and the relative standard deviation was below 2.79%. A detection limit of 2.12-5.12 microgmL(-1) was reached and a linear range was found between peak height and concentration in the range of 10.36-518.0 microgmL(-1) for oxytetracycline (OTC), 12.11-605.5 microgmL(-1) for tetracycline (TC), 11.79-589.5 microgmL(-1) for chlortetracycline (CTC) and 10.32-516.0 microgmL(-1) for doxycycline (DC). The linear regression coefficients were all above 0.999. The method has been applied successfully to the determination of OTC, TC, CTC, DC in pharmaceutical formulations and in honey. The method was simple, rapid and showed a better linear relation and high repeatability.


Asunto(s)
Antibacterianos/análisis , Cromatografía Líquida de Alta Presión/métodos , Tetraciclinas/análisis , Clortetraciclina/análisis , Cromatografía Liquida/métodos , Doxiciclina/análisis , Residuos de Medicamentos/análisis , Miel/análisis , Indicadores y Reactivos , Análisis de Regresión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Fluorescencia/métodos , Tetraciclina/análisis
4.
Se Pu ; 20(6): 550-3, 2002 Nov.
Artículo en Zh | MEDLINE | ID: mdl-12683006

RESUMEN

A method for the separation and determination of theanine in tea leaves has been developed, based on inhibited chemiluminescence of cobalt-catalyzed luminol-H2O2 reaction by theanine. Separations were performed on a YWG-C18 column using a mobile phase of 0.01 mol.L-1 sodium acetate-acetic acid buffer at pH 5.5 at a flow rate of 0.8 mL.min-1. The optimum concentrations of Co2+, luminol, and H2O2 were 2 micrograms.L-1, 0.25 mmol.L-1, and 0.5 mmol.L-1, respectively. Under the conditions mentioned above, the relative peak area (Y) of inhibited chemiluminescence of theanine was linear with the concentration (X) of theanine in the range of 0.2 g.L-1-5.0 g.L-1 and its linear regression equation was Y = 33,862 x + 1.0605 (r = 0.9983). The average recovery was 97.82% with a RSD of 2.16%.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Glutamatos/análisis , Té/química , Catálisis , Cobalto , Mediciones Luminiscentes , Luminol , Hojas de la Planta/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA