Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Prosthodont ; 24(1): 25-31, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25082075

RESUMEN

PURPOSE: To determine the dimensional stability of a poly(methyl methacrylate) (PMMA) acrylic resin when subjected to multiple sessions of repeated microwave irradiation at power settings of 700 and 420 W. MATERIALS AND METHODS: Twenty standardized denture bases were fabricated using a PMMA resin. Points of measurement were marked on each denture base with a standardized template, and the distances between points were recorded using a digital microscope. The denture bases were randomly placed into two experimental groups of 10 bases each. Individual denture bases were placed into a glass beaker containing 200 ml of room temperature deionized water and then exposed to either 700 or 420 W of microwave radiation for 3 minutes. The denture bases were allowed to cool to room temperature, and measurements between points were recorded. This process was carried out for two microwave periods with measurements being completed after each period. The data were then analyzed for any significant changes in distances between points using a Student's t-test. RESULTS: All denture bases experienced 1.0 to 2.0 mm or approximately 3% linear dimensional change after each period of microwaving. Results were significant with all t-tests having values of p < 0.05. CONCLUSION: This report showed that the denture bases deformed significantly under experimental conditions at either 700 W for 3 minutes in 200 ml of water or 420 W for 3 minutes in 200 ml of water.


Asunto(s)
Resinas Acrílicas/efectos de la radiación , Materiales Dentales/efectos de la radiación , Bases para Dentadura , Dentaduras , Resinas Acrílicas/química , Resinas Acrílicas/uso terapéutico , Materiales Dentales/química , Materiales Dentales/uso terapéutico , Humanos , Microondas , Polimetil Metacrilato/química , Polimetil Metacrilato/efectos de la radiación , Polimetil Metacrilato/uso terapéutico
3.
Implant Dent ; 15(3): 290-7, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16966903

RESUMEN

OBJECTIVES: To our knowledge, it has not as yet been determined if mini-dental implants can be used as a long-term treatment method compared to endosseous standard root-form dental implant fixtures. This in vitro study investigates the stability of 2 different implants, 1 mini-dental implant and 1 endosseous standard root form dental implant, under lateral forces. METHODS: There were 2 different screw-type dental implants with the O-ring/ball attachment prosthetic heads used. A mini-dental implant (Sendax MDI MAX; IMTEC, Corp., Ardmore, OK) 13 mm in length and 2.2 mm in diameter, and root form implant (Brånemark; Nobel Biocare AB, Goteborg, Sweden) 13 mm in length and 4 mm in diameter. These implants were then embedded into a matrix mixture of pumice, two-fifths BaSO4 powder and one-fifth plaster. Parallel periapical radiographs were taken pretest and after lateral forces were applied. The implants were vibrated using electric toothbrushes. They were attached to O-rings on the implants. Periapical radiographs were secured periodically every 5 minutes. The first discrepancy was observed at the 35th minute. Mobility and discrepancy values were recorded at the instances of 35th, 60th, 90th, and 120th minutes. Stability was measured and recorded using a manual stress and tension gauge. Radiographic discrepancy values were measured using a stereomicroscope. RESULTS: The Brånemark implant showed less mobility and discrepancy values than the mini-dental implant. The discrepancies were observed mostly at the cervical region of the 2 implants. CONCLUSIONS: According to the experimental results of this study, the Brånemark implant was more stable than the mini-dental implant at the end of 2 minutes.


Asunto(s)
Implantes Dentales , Movilidad Dentaria/diagnóstico por imagen , Diente Artificial , Técnicas In Vitro , Radiografía , Soporte de Peso
4.
Implant Dent ; 12(3): 232-4, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14560483

RESUMEN

The unitized (one-piece) dowel-crown technique described in this article uses routine clinical and laboratory procedures, minimizes clinical appointments, and provides a simplified prosthetic restoration for a single dental implant.


Asunto(s)
Implantes Dentales de Diente Único , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Técnica de Perno Muñón , Pilares Dentales , Aleaciones de Oro/química , Humanos , Técnica de Perno Muñón/instrumentación
5.
J Prosthodont ; 13(1): 52-4, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15032897

RESUMEN

Dental implant screw fracture involves attempting to retrieve the screw fragment or, as an alternative, attempting to salvage the dental implant. Circumstances that do not allow for screw retrieval require a solution in which the internal configuration of the dental implant can provide for a custom direct dowel fabrication. The proposed technique is to retrofit the fabrication of a custom cast dowel-core and provisional use of a direct procedure, which provides accuracy of fit, retention, and ease of production.


Asunto(s)
Pilares Dentales , Implantes Dentales , Fracaso de la Restauración Dental , Técnica de Perno Muñón , Coronas , Diseño de Prótesis Dental , Retención de Prótesis Dentales , Humanos , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA