Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 262(9): 2925-2936, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38530450

RESUMEN

PURPOSE: To determine if early central corneal thickness (CCT) and best-corrected visual acuity (BCVA) changes indicate graft detachment after uncomplicated Descemet membrane endothelial keratoplasty (DMEK). METHODS: In this analysis of our prospectively collected ADDA registry data ( https://drks.de/search/de/trial/DRKS00027180 ), 45 pseudophakic eyes underwent DMEK surgery at the Department of Ophthalmology, RWTH Aachen University. Anterior segment optical coherence tomography (AS-OCT), the presence of stromal ripples on the posterior corneal surface, and BCVA measurements were assessed prior to, 1 day, 1 week, 1 month, and 6 months after surgery. RESULTS: Eyes were categorized into three groups: no graft detachment (group 1) (20/45; 44.4%), < 1/3 graft detachment (group 2) (14/45; 31.1%), ≥ 1/3 graft detachment followed by rebubbling (group 3) (11/45; 24.4%). Eyes in group 3 had a greater CCT prior to (746.8 ± 95.8 µm vs. 665.0 ± 74.4 µm, P = 0.041), and 1 week (666.8 ± 119.5 µm vs. 556.5 ± 56.8 µm, P = 0.001) after DMEK compared to group 1. By 1 month, CCT in all groups aligned. Comparing prior to and 1 week after DMEK, none of the eyes in group 1 had an increase in CCT, while the CCT increased in 25.0% of eyes in group 2 and 22.2% in group 3. In group 1, 90.0% had a CCT of < 600 µm 1 week after DMEK, compared to only 50.0% in group 2 and 36.4% in group 3. In group 1, 90.0% (18/20) had an improved BCVA 1 week after DMEK, while in groups 2 and 3, 86.7% (12/14) and 18.2% (2/11) improved, respectively. One patient in group 3 showed posterior stromal ripples 1 day and 1 week after DMEK. CONCLUSION: If 1 week after uncomplicated DMEK CCT is < 600 µm and has decreased from before surgery, BCVA has improved, and there are no posterior stromal ripples, a graft detachment ≥ 1/3 and the need for rebubbling are very unlikely. In all other cases, meticulous slit-lamp and OCT inspection of the peripheral graft for detachments should be advised.


Asunto(s)
Córnea , Queratoplastia Endotelial de la Lámina Limitante Posterior , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Masculino , Femenino , Tomografía de Coherencia Óptica/métodos , Anciano , Estudios Prospectivos , Córnea/patología , Córnea/diagnóstico por imagen , Estudios de Seguimiento , Persona de Mediana Edad , Rechazo de Injerto/diagnóstico , Supervivencia de Injerto , Complicaciones Posoperatorias , Anciano de 80 o más Años , Enfermedades de la Córnea/cirugía , Enfermedades de la Córnea/diagnóstico , Endotelio Corneal/patología , Lámina Limitante Posterior/cirugía , Lámina Limitante Posterior/patología , Distrofia Endotelial de Fuchs/cirugía , Distrofia Endotelial de Fuchs/diagnóstico
2.
Int Ophthalmol ; 44(1): 406, 2024 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-39400779

RESUMEN

PURPOSE: To evaluate the treatment success and safety of ab interno canaloplasty (AbiC) combined with cataract surgery in glaucoma patients. METHODS: The prospective case study included 43 eyes that received an AbiC combined with cataract surgery (age 73.3 ± 8.2 years). The 360° microcatheterization and viscodilatation of the Schlemm's canal was conducted using VISCO 360 (Sight Sciences, CA, USA). The observation period was 12 months with visits at 2 and 6 as well as 12 months, 7 eyes were lost to follow up. RESULTS: The preoperative IOP was 19.8 ± 4.9 mmHg and was reduced to 14.5 ± 2.8 mmHg 12 months after AbiC (p < 0.0001). The relative IOP reduction was 23.6 ± 23.1% after 12 months. Topical glaucoma medication was also reduced from 2.4 ± 1.1 drugs to 1.1 ± 1.4 (p < 0.001) after 12 months. The complete surgical success rate (defined as IOP < 18 mmHg without topical therapy) was 31.6% whereas the qualified surgical success was 89.5% (IOP < 18 mmHg, with local therapy) There were no relevant intra- or postoperative complications. CONCLUSION: AbiC in combination with cataract surgery is a safe and effective procedure to achieve a significant reduction of IOP and local glaucoma medication 12 months after surgery.


Asunto(s)
Cirugía Filtrante , Glaucoma , Presión Intraocular , Agudeza Visual , Humanos , Estudios Prospectivos , Anciano , Masculino , Femenino , Presión Intraocular/fisiología , Cirugía Filtrante/métodos , Anciano de 80 o más Años , Glaucoma/cirugía , Glaucoma/fisiopatología , Glaucoma/complicaciones , Estudios de Seguimiento , Resultado del Tratamiento , Extracción de Catarata/métodos , Persona de Mediana Edad
3.
Int Ophthalmol ; 43(8): 2605-2612, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36862355

RESUMEN

PURPOSE: To evaluate the efficacy and safety of excisional goniotomy performed with the Kahook Dual Blade (KDB) combined with cataract surgery in patients with pimary open angle glaucoma (POAG) and Normal Tension Glaucoma (NTG) under topical therapy. Further sub-analysis was performed to compare between 90 and 120 degrees goniotomy. METHODS: This was a prospective case series of 69 eyes from 69 adults (age 78 ± 5.9 years; male = 27, female = 42). Indications for surgery included insufficient IOP control with topical medication, glaucomatous damage progression under topical therapy and reduction of medication burden. Complete success was defined as IOP lowering below 21 mmHg without the need for topical medication. For NTG patients, complete success was defined as IOP lowering below 17 mmHg without the need for topical medication. RESULTS: IOP was significantly lowered from 19.7 ± 4.7 to 15.1 ± 2.7 at 2 months, 15.8 ± 2.3 at 6 months and 16.1 ± 3.2 at 12 months (p < 0.05) for POAG and 15.1 ± 2.5 to 14.1 ± 2.4 at 2 months, 14.1 ± 3.1 at 6 months and 13.6 ± 1.8 at 12 months (p > 0.08) for NTG, respectively. Complete success was achieved in 64% of the patients. IOP lowering under 17 mmHg without the need for topical medication was achieved in 60% of the patients at 12 months. In NTG patients (14 eyes) IOP lowering under 17 mmHg without the need for topical medication was achieved in 71%. No significant difference was recorded in terms of IOP lowering at 12 months in-between 90° and 120° of treated trabecular meshwork (p > 0.7). No severe adverse reactions were recorded in this study. CONCLUSION: One-year results show that KDB combined with cataract surgery is an effective treatment option for glaucoma patients. IOP lowering was successfully achieved in NTG patients with complete success in 70% of the patients. In our study, no significant differences were recorded in-between 90° and 120° of treated trabecular meshwork.


Asunto(s)
Catarata , Glaucoma de Ángulo Abierto , Glaucoma , Glaucoma de Baja Tensión , Trabeculectomía , Adulto , Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Trabeculectomía/métodos , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Baja Tensión/cirugía , Glaucoma de Baja Tensión/etiología , Presión Intraocular , Tonometría Ocular , Estudios Retrospectivos , Glaucoma/cirugía , Resultado del Tratamiento , Catarata/complicaciones
4.
Int Ophthalmol ; 42(9): 2685-2696, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35357642

RESUMEN

PURPOSE: Single-use dual blade goniotomy (SBG) is a novel ab interno procedure that removes three to five clock hours of trabecular meshwork (TM). We analysed the reduction of intraocular pressure (IOP) and topical glaucoma medication (Meds) in eyes following combined cataract surgery and SBG (Cat-SBG). METHODS: IOP and Meds were evaluated retrospectively in 55 eyes of 38 patients. 44 eyes had high tension glaucoma (HTG) and eleven eyes had normal tension glaucoma (NTG). Complete success (no Meds) and qualified success (with Meds) for IOP levels ≤ 21, ≤ 18 , ≤ 16 mmHg or ≥ 20% IOP reduction at the two- and six-month follow-up were evaluated. RESULTS: IOP and Meds were significantly reduced from before to two months after Cat-SBG in HTG- and NTG-patients (HTG: IOP 19.4 ± 3.3 to 15.1 ± 3.3 mmHg; p < 0.001; Meds 2.1 ± 1.3 to 0.8 ± 1.3; p < 0.001; NTG: IOP 14.0 ± 2.3 to 11.5 ± 2.3 mmHg; p = 0.004; Meds 1.6 ± 0.7 to 0.3 ± 0.7; p < 0.001). IOP and Meds did not change significantly from two to six months after Cat-SBG. In HTG, complete and qualified success rates were 43% (19/44) and 93% (41/44) for IOP ≤ 18 mmHg, 36% (16/44) and 64% (28/44) for IOP ≤ 16 mmHg and 30% (13/44) and 43% (19/44) for ≥ 20% IOP reduction six months after surgery. In NTG, complete and qualified success was 81% (9/11) and 100% (11/11) for IOP ≤ 18 and ≤ 16 mmHg, and 27% (3/11) for IOP reduction ≥ 20%. IOP and Meds reduction were comparable between HTG and NTG eyes. Only minor postoperative complications occurred. CONCLUSION: Cat-SBG is an efficient method to significantly lower IOP in patients with HTG and NTG.


Asunto(s)
Catarata , Glaucoma , Glaucoma de Baja Tensión , Hipotensión Ocular , Trabeculectomía , Humanos , Presión Intraocular , Estudios Retrospectivos , Resultado del Tratamiento
5.
Graefes Arch Clin Exp Ophthalmol ; 259(8): 2251-2257, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34019151

RESUMEN

PURPOSE: To investigate the relationship of ocular blood flow (via arteriovenous passage time, AVP) and contrast sensitivity (CS) in healthy as well as normal tension glaucoma (NTG) subjects. DESIGN: Mono-center comparative prospective trial METHODS: Twenty-five NTG patients without medication and 25 healthy test participants were recruited. AVP as a measure of retinal blood flow was recorded via fluorescein angiography after CS measurement using digital image analysis. Association of AVP and CS at 4 spatial frequencies (3, 6, 12, and 18 cycles per degree, cpd) was explored with correlation analysis. RESULTS: Significant differences regarding AVP, visual field defect, intraocular pressure, and CS measurement were recorded in-between the control group and NTG patients. In NTG patients, AVP was significantly correlated to CS at all investigated cpd (3 cpd: r = - 0.432, p< 0.03; 6 cpd: r = - 0.629, p< 0.0005; 12 cpd: r = - 0.535, p< 0.005; and 18 cpd: r = - 0.58, p< 0.001), whereas no significant correlations were found in the control group. Visual acuity was significantly correlated to CS at 6, 12, and 18 cpd in NTG patients (r = - 0.68, p< 0.002; r = - 0.54, p< .02, and r = - 0.88, p< 0.0001 respectively), however not in healthy control patients. Age, visual field defect MD, and PSD were not significantly correlated to CS in in the NTG group. MD and PSD were significantly correlated to CS at 3 cpd in healthy eyes (r = 0.55, p< 0.02; r = - 0.47, p< 0.03). CONCLUSION: Retinal blood flow alterations show a relationship with contrast sensitivity loss in NTG patients. This might reflect a disease-related link between retinal blood flow and visual function. This association was not recorded in healthy volunteers.


Asunto(s)
Glaucoma de Baja Tensión , Sensibilidad de Contraste , Ojo , Humanos , Presión Intraocular , Glaucoma de Baja Tensión/diagnóstico , Estudios Prospectivos
6.
Graefes Arch Clin Exp Ophthalmol ; 259(9): 2731-2741, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33977320

RESUMEN

PURPOSE: To determine retinal thickness (RT) changes and the incidence of macular edema after uncomplicated Descemet membrane endothelial keratoplasty (DMEK-ME) in patients without ME risk factors. METHODS: In this retrospective study, 107 pseudophakic eyes of 74 patients with Fuchs endothelial dystrophy (FED) (79.4%) or bullous keratopathy (BK) (20.6%) underwent DMEK surgery between 2016 and 2019 at the Department of Ophthalmology, RWTH Aachen University. Patients with intra- or postoperative complications as well as pre-existing risk factors for ME were excluded. Macular spectral-domain optical coherence tomography (SD-OCT) and best spectacle-corrected visual acuity (BSCVA) measurements were performed before, 1 week, 1 month, and 6 months after surgery. Retinal thickness (RT) was analyzed in the central foveal 1 mm (CSF), parafoveal 3 mm and 6 mm subfield. RESULTS: Eight eyes (7.5%) developed DMEK-ME 1 month after surgery. Six DMEK-ME eyes (75%) were rebubbled, compared with 31.3% (31 of 99; P = 0.02) of the non DMEK-ME eyes. DMEK-ME eyes had a significantly thicker CSF 1 month after surgery (432.0 ± 97.6 µm) compared with non-DMEK-ME eyes (283.7 ± 22.2 µm; P = 0.01). The other subfields and time points showed no significant RT changes. DMEK-ME significantly impaired BSCVA (0.38 ± 0.92 logMAR) only 1 month after surgery in comparison to the non DMEK-ME eyes (0.23 ± 0.87 logMAR, P = 0.015). CONCLUSION: Excluding systemic and surgery-related risk factors, rebubbling increases the risk of DMEK-ME. Performing a CSF scan 1 month after surgery, particularly in rebubbled eyes, efficiently detects DMEK-ME and allows the prompt initiation of treatment, e.g., topical corticosteroid and non-steroidal (NSAID) eye drops.


Asunto(s)
Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Recuento de Células , Lámina Limitante Posterior , Endotelio Corneal , Distrofia Endotelial de Fuchs/cirugía , Humanos , Estudios Retrospectivos , Agudeza Visual
7.
Int Ophthalmol ; 41(9): 3109-3119, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34009518

RESUMEN

PURPOSE: Vascular risk factors and ocular perfusion are heatedly discussed in the pathogenesis of glaucoma. The retinal vessel analyzer (RVA, IMEDOS Systems, Germany) allows noninvasive measurement of retinal vessel regulation. Significant differences especially in the veins between healthy subjects and patients suffering from glaucoma were previously reported. In this pilot-study we investigated if localized vascular regulation is altered in glaucoma patients with altitudinal visual field defect asymmetry. METHODS: 15 eyes of 12 glaucoma patients with advanced altitudinal visual field defect asymmetry were included. The mean defect was calculated for each hemisphere separately (-20.99 ± 10.49 profound hemispheric visual field defect vs -7.36 ± 3.97 dB less profound hemisphere). After pupil dilation, RVA measurements of retinal arteries and veins were conducted using the standard protocol. The superior and inferior retinal vessel reactivity were measured consecutively in each eye. RESULTS: Significant differences were recorded in venous vessel constriction after flicker light stimulation and overall amplitude of the reaction (p < 0.04 and p < 0.02 respectively) in-between the hemispheres. Vessel reaction was higher in the hemisphere corresponding to the more advanced visual field defect. Arterial diameters reacted similarly, failing to reach statistical significance. CONCLUSION: Localized retinal vessel regulation is significantly altered in glaucoma patients with asymmetric altitudinal visual field defects. Veins supplying the hemisphere concordant to a less profound visual field defect show diminished diameter changes. Vascular dysregulation might be particularly important in early glaucoma stages prior to a significant visual field defect.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Glaucoma/diagnóstico , Humanos , Presión Intraocular , Proyectos Piloto , Estudios Prospectivos , Vasos Retinianos , Pruebas del Campo Visual , Campos Visuales
8.
Int Ophthalmol ; 41(5): 1585-1592, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33521894

RESUMEN

PURPOSE: We assessed the accuracy of lens power calculation in highly myopic patients implanting plus and minus intraocular lenses (IOL). METHODS: We included 58 consecutive, myopic eyes with an axial length (AL) > 26.0 mm, undergoing phacoemulsification and IOL implantation following biometry using the IOLMaster 500. For lens power calculation, the Haigis formula was used in all cases. For comparison, refraction was back-calculated using the Barrett Universal II (Barrett), Holladay I, Hill-RBF (RBF) and SRK/T formulae. RESULTS: The mean axial length was 30.17 ± 2.67 mm. Barrett (80%), Haigis (87%) and RBF (82%) showed comparable numbers of IOLs within 1 diopter (D) of target refraction. Visual acuity (BSCVA) improved (p < 0.001) from 0.60 ± 0.35 to 0.29 ± 0.29 logMAR (> 28-days postsurgery). The median absolute error (MedAE) of Barrett 0.49 D, Haigis 0.38, RBF 0.44 and SRK/T 0.44 did not differ. The MedAE of Haigis was significantly smaller than Holladay (0.75 D; p = 0.01). All median postoperative refractive errors (MedRE) differed significantly with the exception of Haigis to SRK/T (p = 0.6): Barrett - 0.33 D, Haigis 0.25, Holladay 0.63, RBF 0.04 and SRK/T 0.13. Barrett, Haigis, Holladay and RBF showed a tendency for higher MedAEs in their minus compared to plus IOLs, which only reached significance for SRK/T (p = 0.001). Barrett (p < 0.001) and RBF (p = 0.04) showed myopic, SRK/T (p = 002) a hyperopic shift in their minus IOLs. CONCLUSIONS: In highly myopic patients, the accuracies of Barrett, Haigis and RBF were comparable with a tendency for higher MedAEs in minus IOLs. Barrett and RBF showed myopic, SRK/T a hyperopic shift in their minus IOLs.


Asunto(s)
Lentes Intraoculares , Miopía , Facoemulsificación , Biometría , Humanos , Interferometría , Implantación de Lentes Intraoculares , Miopía/diagnóstico , Óptica y Fotónica , Refracción Ocular , Estudios Retrospectivos
9.
Graefes Arch Clin Exp Ophthalmol ; 258(2): 303-310, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31863398

RESUMEN

PURPOSE: Nonperfusion of retinal tissue due to arterial occlusion leads inevitably to mostly irreversible retinal damage. Until today no evidence-based treatment exists. Inhalation of 100% oxygen at high atmospheric pressure causes an increased solubility of oxygen in the blood that helps the retinal tissue to survive through diffusion in case of an artery occlusion till vascular recanalization occurs. Hence the purpose of this study is to compare the visual outcome in patients with retinal branch artery obstruction treated with hyperbaric oxygen versus patients treated with hemodilution only. METHODS: Non-randomized, monocentric, retrospective study. Patients with diagnosis of non-arteritic retinal branch artery occlusion (BRAO) treated with hyperbaric oxygen therapy between 1997 and 2017. Exclusion criteria were central retinal artery occlusion, presence of a cilioretinal artery and arteritic cases. The control group was matched based on visual acuity (VA) at admission, age, and delay between symptoms and beginning of clinical care. RESULTS: The control group and the matching oxygen group contained 14 patients each. Initial VA in the matched HBO group was 0.18 ± 0.19 and 0.23 ± 0.19 in the control group (p = 0.57). Final VA at discharge was 0.69 ± 0.29 in the matched oxygen group and 0.32 ± 0.23 in the control group (p = 0.0009). HBO-treated patients had a significant visual increase compared with the control group. The most common comorbidities were arterial hypertension and vascular sclerosis. CONCLUSION: HBO treatment appears to have a beneficial effect on visual outcome in patients with retinal branch artery occlusion. HBO treatment could be a rescue therapy at an early stage of BRAO, especially to bridge the time of a potential reperfusion. However, further, prospective, randomized clinical trials are required to verify this assumption.


Asunto(s)
Arterias Ciliares/patología , Oxigenoterapia Hiperbárica/métodos , Retina/patología , Oclusión de la Arteria Retiniana/terapia , Agudeza Visual , Anciano , Femenino , Angiografía con Fluoresceína/métodos , Estudios de Seguimiento , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/metabolismo , Oclusión de la Arteria Retiniana/diagnóstico , Oclusión de la Arteria Retiniana/metabolismo , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
10.
Graefes Arch Clin Exp Ophthalmol ; 258(2): 387-393, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31811364

RESUMEN

BACKGROUND: Canaloplasty is a well-established non-penetrating glaucoma surgery. Unsuccessful outcomes can be enhanced by micro-invasive 360° suture trabeculotomy (360°trabeculotomy), analyzed in this study. METHODS: This retrospective study included twenty eyes of 19 patients, mean age 59.7±17.2 years, with primary open-angle glaucoma (POWG n = 14), pseudoexfoliation glaucoma (PEX n = 3), juvenile glaucoma (n = 2) and aphakic glaucoma (n = 1), who underwent micro-invasive 360° trabeculotomy after unsuccessful (intraocular pressure (IOP) >21 mmHg under maximum glaucoma eye drop therapy (Meds)) canaloplasty. IOPs, Meds, complications and failure rates (IOP >21 mmHg at two consecutive follow-ups) were evaluated. Complete success (no Meds) and qualified success (with Meds) rates for IOP levels ≤21 mmHg and ≤ 18 mmHg at the last follow-up were evaluated. RESULTS: IOPs and Meds were significantly reduced from before to 1 week (10.3±3.1 days) after 360° trabeculotomy (IOP, 28.3±6.0 mmHg to 15.8±4.5 mmHg; p < 0.001; Meds, 3.1 ± 1.2 to 1.0 ± 1.2; p < 0.001). IOPs (p = 0.37) and Meds (p = 0.33) did not decrease further from 1 week until the last follow-up (18.3 ± 8.2 months (IOP, 14.4±3.8 mmHg; Meds, 1.5±1.3)). Complete and qualified success was 25% (5/20) and 70% (14/20) for IOP ≤21 mmHg, as well as 25% (5/20) and 60% (12/20) for IOP ≤18 mmHg. Four eyes had postoperative hyphema, which resolved after a mean period of 4.0 ± 2.2 days. Five failures occurred after a mean of 40.6 ± 51.9 days after 360° trabeculotomy. All failures underwent trabeculectomy. Eyes that needed early (≤3 months post canaloplasty) 360° trabeculotomy showed higher IOPs before (p < 0.001) and lower (p = 0.03) IOPs 2 months post 360° trabeculotomy than eyes with late (>3 months) 360° trabeculotomy surgery. CONCLUSIONS: 360° trabeculotomy is a safe, micro-invasive, simple and successful method to enhance failed canaloplasty.


Asunto(s)
Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular/fisiología , Técnicas de Sutura/instrumentación , Suturas , Trabeculectomía/métodos , Agudeza Visual , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
11.
Klin Monbl Augenheilkd ; 236(1): 88-95, 2019 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-28683479

RESUMEN

We repeatedly examined 17 subjects with presumed bilateral physiological excavation labeled as pathological and/or borderline via HRT to verify the diagnosis of physiological cupping or to monitor the long-term progression into normal tension glaucoma. PATIENTS AND METHODS: 17 Subjects with presumed bilateral physiological cupping and large optic discs were included in this long-term follow-up study. All subjects underwent regular detailed ophthalmologic examinations, including intraocular pressure measurement via Goldmann applanation tonometry (GAT), retinal nerve fiber layer imaging via optical coherence tonometry (OCT) and visual field testing and optic disc imaging using the HRT. Glaucomatous progression was identified using the HRT's tools (stereometric trend analysis [STA] and topographic change analysis [TCA]). RESULTS: In the initial examination, all 17 subjects were classified as "pathological", by the HRT's Moorfield's Regression Analysis (MRA). Over the observation period of 9.2 ± 5 years, only 1 of the 17 subjects showed an ensured conversion to normal tension glaucoma with glaucomatous visual field defects. The remaining 16 subjects show no visual field defects to date. STA showed significant changes in 3 subjects alone, in 1 subject TCA showed a significant change alone, and in 1 subject both analyses showed a progressive change. CONCLUSION: After 9 years of regular examinations, 16 of the 17 subjects that were classified as "pathological" using MRA showed no glaucomatous visual field defects. In 5 out of these 16 subjects, progressive changes of the optic disc could be recorded via HRT. Therefore, the diagnostic precision of the HRT measurements seems to be limited in patients with large discs and physiological cupping.


Asunto(s)
Oftalmoscopía , Disco Óptico , Campos Visuales , Estudios de Seguimiento , Humanos , Presión Intraocular , Oftalmoscopía/métodos , Pruebas del Campo Visual
12.
Int Ophthalmol ; 39(3): 597-604, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29442245

RESUMEN

PURPOSE: Evaluation of ocular haemodynamics in patients with acute non-arteritic anterior ischaemic optic neuropathy (NAION) by colour Doppler imaging and fluorescein angiography and correlation of blood flow parameters to visual field loss and visual acuity. METHODS: Blood flow velocities (peak systolic velocity (PSV), end-diastolic velocity (EDV)) of the ophthalmic artery (OA), central retinal artery (CRA) and nasal and temporal posterior ciliary arteries (PCAs) were measured via colour Doppler imaging. Resistive index (RI) of all vessels was calculated (PSV-EDV/PSV). Retinal arteriovenous passage times (AVP) were evaluated using fluorescein angiography (scanning laser ophthalmoscope) and digital image analysis. The visual field global index mean deviation (MD, 30-2 programme, Humphrey Field Analyzer) and visual acuity (logMar) was used for analysis of functional impairment after NAION. RESULTS: Twenty patients (age: 64.62 ± 11.63 years) with acute NAION were included. Mean duration of symptoms was 7.6 ± 6.9 days. Mean defect was 15.4 ± 8.9 dB, AVP was determined with 1.66 ± 0.37 s. EDV of the CRA was significantly correlated to visual field MD (r = 0.52, p = 0.017) and AVP (r = - 0.49, p = 0.025). The RI of the OA was significantly correlated to visual acuity (r = 0.493, p < 0.037). No significant correlations were recorded for the PCAs. A significant correlation was found between AVP and the EDV of the CRA (r = - 0.49, p = 0.025). CONCLUSION: Decreased EDV in the CRA and increased RI in the OA seem to be linked to the functional damage in NAION. An improvement of the retrobulbar circulation might be beneficial in the treatment of NAION.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Arterias Ciliares/fisiopatología , Arteria Oftálmica/fisiopatología , Neuropatía Óptica Isquémica/fisiopatología , Arteria Retiniana/fisiopatología , Trastornos de la Visión/etiología , Arterias Ciliares/diagnóstico por imagen , Femenino , Angiografía con Fluoresceína , Fondo de Ojo , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Arteria Oftálmica/diagnóstico por imagen , Neuropatía Óptica Isquémica/complicaciones , Neuropatía Óptica Isquémica/diagnóstico , Flujo Sanguíneo Regional/fisiología , Arteria Retiniana/diagnóstico por imagen , Ultrasonografía Doppler en Color , Trastornos de la Visión/fisiopatología , Agudeza Visual , Campos Visuales/fisiología
13.
Graefes Arch Clin Exp Ophthalmol ; 256(6): 1117-1126, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29623460

RESUMEN

PURPOSE: Amniotic membrane (AM) is an essential tool in ocular surface reconstruction. In this study, we analyzed the differential effects of glycerol and straight storage at - 80 °C for up to 6 months on the structural, biological, and mechanical properties of amniotic membrane (AM). METHODS: Human placentae of 11 different subjects were analyzed. AMs were stored at - 80 °C, either with a 1:1 mixture of Dulbecco's modified Eagle medium and glycerol (glycerol) or without any medium or additives (straight). Histological image analysis, tensile strength, cell viability, and basic fibroblast growth factor (bFGF) secretion were evaluated at 0.5, 1, 3, and 6 months. RESULTS: Histologically, neither glycerol nor straight storage significantly altered the epithelial or stromal structure of the AM. However, the cell number of the stroma was significantly reduced during the freezing process, independently of the storage method (p = 0.05-0.001). Tensile strength and Young's modulus were not influenced by the storage method, but longer storage periods significantly increased the tensile strength of the AMs (p = 0.028). Cell viability was higher in glycerol rather than straight AM samples for up to 3 months of storage (p = 0.047-0.03). Secretion of bFGF at 3 months of storage was significantly higher in glycerol versus straight frozen AM samples (p = 0.04). DISCUSSION: Glycerol led to higher cell viability and higher bFGF secretion for up to 3 months of AM storage. However, no significant differences between the two methods were observed at 6 months of storage at - 80 °C.


Asunto(s)
Amnios/citología , Criopreservación/métodos , Glicerol/farmacología , Amnios/trasplante , Células Cultivadas , Oftalmopatías/cirugía , Femenino , Humanos , Embarazo
14.
Clin Exp Ophthalmol ; 46(5): 473-479, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29136327

RESUMEN

IMPORTANCE: To investigate the long-term safety of a novel intraocular telemetric pressure sensor. BACKGROUND: Acquisition of accurate intraocular pressure (IOP) data is vital for sufficient medical care of glaucoma patients. Non-invasive self-tonometry with a telemetric IOP sensor can provide important information regarding the individual IOP profile. DESIGN: Retrospective analysis of long-term follow-up data assessed during outpatient visits in a university hospital. PARTICIPANTS: Six patients with open-angle glaucoma were included. Unfortunately, one patient passed away shortly after completion of the original 1-year study. METHODS: Within the scope of a prospective 1-year pilot clinical trial, a telemetric IOP sensor was inserted into the ciliary sulcus after intracapsular lens implantation during planned cataract surgery. Patients were regularly examined as outpatients even beyond the duration of the 1-year study. Data concerning sensor functionality, safety parameters and home self-tonometry were assessed. MAIN OUTCOME MEASURES: Long-term sensor functionality and safety. RESULTS: Sensor measurements were always successful in every patient. Additionally, home self-tonometry was conducted without any problems by every patient. The average follow-up period was 37.5 months (21-50 months). During this period, the average number of IOP measurements performed per patient was 1273 (223-2884 measurements). No severe adverse events were reported. A varying degree of pupillary distortion was observed after 6-12 months in every patient; this remained unchanged thereafter with only one exception. CONCLUSIONS AND RELEVANCE: Telemetric IOP sensors showed good functionality and tolerability during long-term follow-up. Non-invasive self-tonometry with a telemetric IOP sensor can provide useful additional data for future monitoring of patients with glaucoma.


Asunto(s)
Glaucoma/fisiopatología , Presión Intraocular/fisiología , Telemetría/instrumentación , Tonometría Ocular/instrumentación , Transductores , Anciano , Diseño de Equipo , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Glaucoma/diagnóstico , Gonioscopía , Humanos , Masculino , Proyectos Piloto , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo
15.
Ophthalmic Res ; 58(2): 74-80, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28449000

RESUMEN

PURPOSE: To evaluate the long-term outcome of trabeculectomy with intra- and postoperative 5-fluorouracil (5-FU) application in glaucoma. METHODS: Eighty-six patients with glaucoma planned for primary trabeculectomy with 5-FU and a minimum follow-up of 3 years were retrospectively analyzed. Success rates, postsurgical 5-FU injections, needling procedures, and complications were analyzed. RESULTS: Mean intraocular pressure (IOP) decreased from 27.2 ± 6.7 to 13.2 ± 4.2 mm Hg at 1 year and 13.8 ± 3.7 mm Hg at the 3-year follow-up. The complete success rates (no IOP-lowering medication) were 83, 79, 73, and 45% at 1 year for IOP ≤21, ≤18, ≤16, and ≤12 mm Hg, respectively, and 64, 59, 56, and 20% for these criteria at 3 years. The average number of medications decreased from preoperatively 2.9 ± 1.4 to 0.2 ± 0.5 at 1 year and 0.7 ± 1.1 at 3 years. During the first 6 months, subconjunctival 5-FU injections were performed in 49 cases. Eleven patients underwent bleb needling during the first 6 months and 13 patients underwent the procedure between the 6th month and the 3rd year. Malignant glaucoma and bleb-related endophthalmitis occurred in 1 patient each. CONCLUSIONS: Trabeculectomy with 5-FU is an efficient surgical procedure for glaucoma treatment when combined with intensified postsurgical care.


Asunto(s)
Fluorouracilo/administración & dosificación , Glaucoma/cirugía , Presión Intraocular , Complicaciones Posoperatorias/prevención & control , Trabeculectomía/métodos , Adulto , Anciano , Conjuntiva , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Glaucoma/fisiopatología , Humanos , Inmunosupresores/administración & dosificación , Incidencia , Inyecciones , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
16.
Graefes Arch Clin Exp Ophthalmol ; 253(7): 1105-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25896108

RESUMEN

PURPOSE: The purpose of this study is to determine the influence of post-surgical corneal edema on the reliability and reproducibility of central corneal thickness (CCT) measurements by a Scheimpflug camera (Pentacam), ultrasound pachymetry (USP), and anterior-segment spectral-domain optical coherence tomography (AS-OCT). METHODS: Thirty-two patients planned for cataract surgery (n = 16) or vitrectomy (n = 6) were included in a prospective study. The non-surgery eye was used as control. Two investigators acquired two measurements each, with the Pentacam (Oculus, Germany) and the AS-OCT (Heidelberg Engineering, Germany) in a randomized order, followed by USP (Tomey SP-100, Germany). CCT was evaluated using the apex value for Pentacam, the corneal apex cut in AS-OCT and averaging eight single measurements for USP. Coefficients of variation (COV) and intra-class correlation coefficients (ICC) were determined. RESULTS: Post-surgery corneas showed a thickness of (investigators 1 and 2): Pentacam (615.9 ± 58.02 µm and 615.1 ± 60.17 µm), USP (601.4 ± 63.77 µm and 614.5 ± 70.91 µm), AS-OCT (608.8 ± 65.67 µm and 606.9 ± 64.41 µm) ,with no significant difference (ANOVA p > 0.99). The COVs (investigators 1 and 2) for control eyes were: Pentacam (0.78 ± 0.52 and 0.70 ± 0.76), USP (0.66 ± 0.29 and 0.98 ± 0.44), AS-OCT (0.59 ± 0.61 and 0.59 ± 0.40). The COVs (investigators 1 and 2) for post-surgical eyes were: Pentacam (0.98 ± 1.25 and 0.97 ± 0.73), USP (0.73 ± 0.64 and 1.35 ± 0.85), AS-OCT (1.34 ± 1.57 and 1.19 ± 1.18).The ICC was determined in post-surgery corneas (ICC > 0.96) and control corneas (ICC > 0.95). CONCLUSION: USP measurements have the highest user dependence. Post-surgical corneal edema leads to higher intraobserver variability. All methods reached a high level of agreement in CCT determination in edematous as well as healthy corneas.


Asunto(s)
Extracción de Catarata , Córnea/patología , Edema Corneal/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Complicaciones Posoperatorias , Vitrectomía , Anciano , Anciano de 80 o más Años , Edema Corneal/etiología , Paquimetría Corneal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Tamaño de los Órganos , Fotograbar , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica
17.
Graefes Arch Clin Exp Ophthalmol ; 253(12): 2255-61, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26338820

RESUMEN

PURPOSE: Blue-yellow short wavelength testing (BY-VEPs) has proven diagnostic relevance in detecting early ganglion cell damage, e.g., in glaucoma. To date testing has generally been conducted using individual protocols without consideration of the lens status. In this study, we compared changes in BY-VEPs and standard pattern VEPs in phakic and pseudophakic glaucoma patients and controls. METHODS: The eyes of 57 healthy controls (18 pseudophakic and 39 phakic) and 67 glaucoma patients (29 pseudophakic and 38 phakic) were included in a prospective study. Phakic eyes were arranged in three groups according to the Lens Opacities Classification System III. Transient on/off isoluminant blue-yellow 2° checks were used for BY-VEPs, transient large 1° (M1) and small 0.25° (M2) black-white checks for standard pattern reversal VEPs, according to the ISCEV standards. RESULTS: Latencies and amplitudes of M1 and M2 did not differ significantly between groups or lens status. ANOVA analysis revealed significantly longer BY-VEP latencies in glaucoma compared to controls (p = 0.002), independently of the lens status. The amplitudes showed no such pattern (p = 0.93). Mean defect (MD) was significantly negatively correlated to BY-VEP latency (r = -0.54, p = 0.003) only in pseudophakic glaucoma patients. Different stages of cataract did not show a significant effect on the BY-VEP latencies. CONCLUSIONS: Glaucoma led to a significant increase of BY-VEPs latencies, while standard pattern VEPs were not influenced. The correlation of MD and BY-VEP latency only in pseudophakic glaucoma patients indicates a substantial confounding effect of lens opacifications on the diagnostic value of BY-VEPs in glaucoma.


Asunto(s)
Catarata/fisiopatología , Potenciales Evocados Visuales/fisiología , Glaucoma/fisiopatología , Cristalino/fisiología , Seudofaquia/fisiopatología , Anciano , Anciano de 80 o más Años , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tiempo de Reacción , Corteza Visual/fisiología , Vías Visuales/fisiología
18.
Ophthalmic Physiol Opt ; 35(2): 194-200, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25529068

RESUMEN

PURPOSE: Previous reports showed increased flow velocities in retrobulbar vessels after glaucoma surgery in the first weeks. Colour Doppler imaging was performed to investigate the long-term effects of trabeculectomy on retrobulbar haemodynamics in patients with primary open-angle glaucoma (POAG). METHODS: In a prospective study 30 patients (mean age 63.2 ± 15.4 years) with POAG were included. Colour Doppler imaging was performed before 1-2 weeks, after 2 months, after 4-6 months, and up to 3 years after trabeculectomy to determine the peak systolic and end-diastolic velocities in the ophthalmic artery, central retinal artery, and the short nasal and temporal posterior ciliary arteries. RESULTS: Mean follow-up was 416 ± 246 days. In the first postsurgical period mean intraocular pressure (IOP) decreased after trabeculectomy from 25 ± 6 mmHg to 9 ± 4 mm Hg (p < 0.0001) and then increased in the further follow-up to 13 ± 3 mmHg (p < 0.05) without any anti-glaucomatous medication. Colour Doppler imaging revealed a significant increase of the end-diastolic velocities of the central retinal artery at all postoperative visits compared to pre-surgery (p < 0.003) and of the end-diastolic velocities in the temporal posterior ciliary arteries (p < 0.003). The change of blood flow parameters that increased during follow-up was significantly correlated to the change in ocular perfusion pressure and IOP. CONCLUSIONS: End-diastolic velocities of the central retinal artery and of the temporal posterior ciliary arteries increased after successful trabeculectomy and remained stable in a longer period - even if IOP rose significantly in the follow-up.


Asunto(s)
Arterias/fisiopatología , Glaucoma de Ángulo Abierto/cirugía , Flujo Sanguíneo Regional/fisiología , Trabeculectomía/efectos adversos , Anciano , Arterias/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Arterias Ciliares/fisiopatología , Femenino , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Arteria Oftálmica/fisiopatología , Estudios Prospectivos , Arteria Retiniana/fisiopatología , Ultrasonografía Doppler en Color
19.
Graefes Arch Clin Exp Ophthalmol ; 252(11): 1831-7, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25030240

RESUMEN

PURPOSE: Blue-yellow visual-evoked potentials (BY-VEPs) may be used for diagnostics of functional ganglion cell damage in glaucoma and other ocular diseases. In this study we investigated the impact of lenticular opacities on BY- and standard pattern reversal VEPs by examining patients before and after cataract surgery. METHODS: Eighteen patients with moderate cataract were included in a prospective study. Transient on/off isoluminant blue-yellow 2° checks were used for short-wavelength stimulation (BY-VEP), transient large 1° (M1) and small 0.25° (M2) black-white checks for standard pattern reversal VEPs. VEPs were acquired before (24 ± 30 days) and after cataract surgery (14 ± 16 days). The contralateral eye was used as a control. RESULTS: Amplitude and latency of M1 and M2 peaks did not change significantly from before to after surgery. The amplitude of the BY-VEPs did not change significantly after cataract surgery (pre-surgery, -7.42 ± 3.43 µV, post-surgery, -7.93 ± 3.65 µV, p = 0.42), yet the latency of the main negative peak showed a significant decrease (pre-surgery, 143.9 ± 12.9 ms, post-surgery, 133.2 ± 7.7 ms, p = 0.0006). The BCVA improvement was significant from before to after cataract surgery (pre-surgery, 0.344 ± 0.125 LogMAR, post-surgery, 0.224 ± 0.179 LogMAR, p = 0.013) yet not correlated to the absolute decrease in latency of the BY-VEP after surgery (r = 0.309, p = 0.22). No significant changes were found in the contralateral eye. CONCLUSIONS: The BY-VEP is sensitive to lenticular opacities of the human lens, presumably due to the increased short-wavelength absorption in the aging eye. This fact should be considered when applying BY-VEPs for diagnostics.


Asunto(s)
Catarata/fisiopatología , Potenciales Evocados Visuales/fisiología , Implantación de Lentes Intraoculares , Facoemulsificación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Células Ganglionares de la Retina/fisiología , Agudeza Visual/fisiología , Vías Visuales/fisiopatología
20.
Ophthalmic Physiol Opt ; 34(4): 438-44, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24731161

RESUMEN

PURPOSE: Direct drug delivery by intravitreal injection is an essential tool in the treatment of retinal diseases and can trigger transient and intermediate intraocular pressure (IOP) peaks. So far no reliable risk factors for pronounced IOP increments have been outlined, which might be particularly important for patients with increased IOP susceptibility such as glaucoma. In this prospective, interventional study IOP changes were analysed directly before and after injection in sitting and supine positions using the Icare rebound tonometer (RT). METHODS: The IOP of 29 patients with macular oedema, who underwent intravitreal injection of 0.05 mL Ranibizumab, was measured in a sitting position 5 min before and two, five and 10 min after surgery. In addition, IOP was also acquired 30 s before and 10 s after injection in a supine position. The effect of age, gender, pseudophakia, axial length, anterior chamber depth, central corneal thickness, scleral thickness and iridocorneal angle width was analysed. RESULTS: Mean pre-injection IOP sitting was 14.3 ± 2.6 mmHg for the treated and 15.5 ± 2.2 mmHg for the control eye. After injection mean IOP rose to 47.2 ± 11.2 mmHg on the treated eye. The IOP of 17 patients returned to values ≤21 mmHg within 10 min. In 12 patients, IOP remained above 21 mmHg after 10 min. No specific risk factor for this group was found. The absolute IOP increase 10 s after injection was significantly correlated to scleral thickness (r = 0.49, p = 0.036) and to the absolute (r = 0.40, p = 0.03) and relative increase (r = 0.39, p = 0.035) of IOP from sitting 5 min before injection to supine position 10 s before injection. CONCLUSIONS: Posture change related IOP increments might have a predictive value for post injection IOP increase. In 40% of the eyes higher IOP-levels (>21 mmHg) remained persistent for a longer period of time. This should be considered especially for glaucomatous eyes.


Asunto(s)
Inhibidores de la Angiogénesis/administración & dosificación , Anticuerpos Monoclonales Humanizados/administración & dosificación , Presión Intraocular/efectos de los fármacos , Inyecciones Intravítreas/efectos adversos , Edema Macular/tratamiento farmacológico , Hipertensión Ocular/inducido químicamente , Posicionamiento del Paciente , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Edema Macular/fisiopatología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Ranibizumab , Factores de Riesgo , Tonometría Ocular/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA