Eur J Orthop Surg Traumatol ; 34(2): 757-769, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37690026

RESUMEN

BACKGROUND: Fracture sequelae of the proximal humerus were classified by Boileau into four types. Since there are pathomorphological differences and specific characteristics within the four types, we have developed a subclassification. For elderly patients, shoulder arthroplasty is mostly recommended. Based on the available literature and clinical trial results, a subclassification could be created that suggests a specific therapy for each subgroup. The aim of this study was to evaluate the endoprosthetic therapy according to the proposed subclassification and to provide an overview of the clinical and radiological results after endoprosthetic treatment of proximal humerus fracture sequelae. METHODS: Patients with fracture sequelae of the proximal humerus who underwent arthroplasty according to the suggestion of the subclassification were included. Minimum time to follow-up was twelve months. General condition and several specific shoulder scores as the Constant-Murley Score (CS) were recorded at the follow-up examination. Complication and revision rates were analyzed. RESULTS: In total, 59 patients (72.6 ± 10.0 years, 47 females, 12 males) were included. Mean follow-up time was 31.3 ± 17.0 months. Reverse shoulder arthroplasty was performed in 49 patients and anatomic shoulder arthroplasty was performed in ten patients. The CS increased by 47.3 points from preoperative (15.0) to postoperative (62.3). Good or very good clinical results were seen in 61% of the patients. Complications were observed in twelve (20%) patients and revision surgery was performed in nine (15%) patients. CONCLUSION: Due to of the variety of fracture sequelae of the proximal humerus, a modification of the Boileau classification seems necessary. This study shows that endoprosthetic treatment for fracture sequelae can significantly improve the shoulder function in elderly patients. Good clinical results can be achieved with a comparatively low revision rate following the treatment suggestions of the proposed subclassification of the Boileau classification. LEVEL OF EVIDENCE IV: Case series.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Fracturas del Hombro , Articulación del Hombro , Masculino , Femenino , Humanos , Anciano , Hombro/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Resultado del Tratamiento , Húmero/cirugía , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios Retrospectivos
2.
BMC Musculoskelet Disord ; 24(1): 63, 2023 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-36694169

RESUMEN

BACKGROUND: Proximal humerus fractures are often treated with a fixed-angle titanium plate osteosynthesis. Recently, plates made of alternative materials such as carbon fibre-reinforced polyetheretherketone (CFR-PEEK) have been introduced. This study presents the postoperative results of patients treated with a CFR-PEEK plate. METHODS: Patients with proximal humerus fractures treated with a CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) were included. In follow-up examination, age and gender adjusted Constant-Murley Score (ACS), Subjective Shoulder Value (SSV), Quick Disabilities of the Arm, Shoulder and Hand Score (QDASH) and pain score (Visual Analog Scale (VAS)) were analyzed. General condition at follow-up was measured by European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-3L). Range of motion was recorded. In addition, radiographs at follow-up, unfavorable events and revision rate were analyzed. RESULTS: In total, 98 patients (66.0 ± 13.2 years, 74 females, 24 males) were reexamined. Mean follow-up was 27.6 ± 13.2 months. There were 15 2-part, 28 3-part and 55 4-part fractures. The functional scores showed good results: SSV 83.3 ± 15.6%, QDASH 13.1 ± 17.0 and ACS 80.4 ± 16.0. A 4-part-fracture, head split component, nonanatomic head shaft reposition and preoperative radiological signs of osteoarthritis were significant negative predictors for poorer clinical scores. Unfavourable events were observed in 27 patients (27.6%). Revision surgery was performed in 8 (8.2%) patients. Risk factors for an unfavourable event were female gender, age of 50 years and older, diabetes, affected dominant hand, 4-part fracture, head split and preoperative radiological signs of osteoarthritis. CONCLUSION: There are several advantages of the CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) such as the polyaxial screw placement and higher stability of locking screws. In summary, the CFR-PEEK plate osteosynthesis is a good alternative with comparable clinical results and some biomechanical advantages. Proximal humerus fractures show good clinical results after treatment with a CFR-PEEK plate. The revision rate and the risk of unfavorable events are not increased compared to conventional titanium plate osteosynthesis. LEVEL OF EVIDENCE: IV.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Masculino , Humanos , Femenino , Persona de Mediana Edad , Titanio , Calidad de Vida , Polímeros , Fibra de Carbono , Polietilenglicoles , Cetonas , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Fracturas del Hombro/etiología , Placas Óseas/efectos adversos , Fracturas del Húmero/etiología , Resultado del Tratamiento , Húmero/cirugía
3.
J Orthop Traumatol ; 24(1): 54, 2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37816859

RESUMEN

BACKGROUND: Plate osteosynthesis with implants made of carbon-fibre-reinforced polyetheretherketone (CFR-PEEK) has recently been introduced for the treatment of fractures of the proximal humerus (PHFs). The advantages of the CFR-PEEK plate are considered to be its radiolucency, its favourable modulus of elasticity, and the polyaxial placement of the screws with high variability of the angle. The primary aim of this study is to investigate the influence of calcar screw positioning on the complication and revision rates after CFR-PEEK plating of PHFs. The secondary aim is to assess its influence on functional outcome. MATERIAL AND METHODS: Patients were identified retrospectively. Minimum follow-up was 12 months. The cohort was divided into two groups depending on the distance of the calcar screw to the calcar (group I: < 12 mm, group II: ≥ 12 mm). The range of motion (ROM), Subjective Shoulder Value Score (SSV) and Constant-Murley Score (CS) were analysed at follow-up examination. Subjective complaints, complications (e.g. humeral head necrosis, varus dislocation) and the revision rate were evaluated. RESULTS: 51 patients (33 female, 18 male) with an average age of 68.6 years were included after a period of 26.6 months (group I: 32 patients, group II: 19 patients). Apart from the gender distribution, no significant differences were seen in the patient characteristics. The outcome scores showed significantly better clinical results in group I: SSV 83.4 vs 71.2, p = 0.007; CS 79.1 vs 67.8, p = 0.013. Complications were seen less frequently in group I (18.8 % vs 47.4 %, p = 0.030). CONCLUSION: This study shows that the positioning of the calcar screw is relevant for CFR-PEEK plate osteosynthesis in PHFs with a good reduction of the fracture. Optimal positioning of the calcar screw close to the calcar (< 12 mm) is associated with a lower rate of complications, resulting in significantly superior functional outcomes. LEVEL OF EVIDENCE: III, retrospective cohort study.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Humanos , Masculino , Femenino , Anciano , Fibra de Carbono , Estudios Retrospectivos , Polietilenglicoles , Cetonas , Fijación Interna de Fracturas/métodos , Tornillos Óseos/efectos adversos , Húmero/cirugía , Fracturas del Hombro/cirugía , Fracturas del Hombro/diagnóstico , Placas Óseas/efectos adversos , Resultado del Tratamiento