1.
J Mater Sci Mater Med ; 23(4): 891-901, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22391991

RESUMEN

Isolation and characterization of metal-on-metal (MoM) wear particles from simulator lubricants is essential to understand wear behaviour, ion release and associated corrosive activity related to the wear particles. Substantial challenges remain to establish a simple, precise and repeatable protocol for the isolation and analysis of wear particles due to their extremely small size, their tendency to agglomerate and degrade. In this paper, we describe a simple and efficient method for the bulk isolation and characterisation of wear particles from MoM bearings. Freeze drying was used to remove the large volume of water from the serum lubricant, enzymes used to digest the proteins and ultracentrifugation to finally isolate and purify the particles. The present study involved a total of eight steps for the isolation process and a wear particle extraction efficiency of 45% was achieved.


Asunto(s)
Prótesis de Cadera , Metales/química , Microscopía Electrónica de Transmisión , Espectrofotometría Atómica
2.
J Arthroplasty ; 24(1): 144-51, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18823742

RESUMEN

The aim of this dry bone study was to determine the range of hip motion to impingement for different hip resurfacing cup positions and component sizes. The maximum angles of hip flexion, extension, abduction, and adduction were calculated from 3-dimensional coordinates for: 1. Cup inclination of 30 degrees , 40 degrees , 50 degrees , 60 degrees , and 70 degrees with fixed anteversion; 2. Cup anteversion of 0 degrees , 10 degrees , 25 degrees , 35 degrees , and 45 degrees with fixed inclination; and 3. 3 different component sizes on the same size dry bones. An acetabular component inclination of 50 degrees and an anteversion of 25 degrees allowed the most physiologic range of hip motion. A larger-diameter femoral component relative to the native femoral neck diameter resulted in a greater range of hip motion to impingement.


Asunto(s)
Articulación de la Cadera/fisiología , Prótesis de Cadera , Metales , Modelos Biológicos , Rango del Movimiento Articular/fisiología , Acetábulo/anatomía & histología , Acetábulo/diagnóstico por imagen , Artroplastia de Reemplazo de Cadera/instrumentación , Fenómenos Biomecánicos , Aleaciones de Cromo , Humanos , Radiografía