Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 173
Filtrar
1.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38588025

RESUMEN

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Estimación de Kaplan-Meier , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Riesgo , Alemania
2.
Eur J Clin Invest ; : e14274, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38925546

RESUMEN

BACKGROUND: Invasive coronary angiography (ICA) is the standard for pre-procedural assessment of coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI). However, it requires hospitalization and can be associated with complications. Computed tomography angiography (CTA) may be a viable alternative to rule out prognostically relevant CAD. METHODS: The EASE-IT CT Registry is an investigator-initiated, prospective, observational, multicentre pilot registry involving patients aged ≥75 years with severe aortic stenosis (AS) intended to implant a transcatheter heart valve (THV) of the SAPIEN family. A total of 150 patients will be recruited from four sites in Germany and Austria. The registry will consist of two prospective cohorts: the investigational CTA-only cohort and the CTA + ICA control cohort. The CTA-only cohort will enrol 100 patients in whom significant (≥50%) left main (LM) and/or proximal left anterior descending artery (LAD) stenosis are ruled out on CTA. The CTA + ICA control cohort will enrol 50 patients who have undergone both CTA and ICA before TAVI and in whom ≥50% LM/proximal LAD stenosis has been ruled out by CTA. Three composite endpoints will be assessed at 3 months post-TAVI: CAD-specific endpoints, VARC-3-defined device success and early safety. CONCLUSION: The EASE-IT CT Registry evaluates whether TAVI can be carried out safely without performing ICA if prognostically relevant CAD of the LM/proximal LAD is ruled out with CTA. If so, the omission of ICA would help streamline the pre-procedural workup of TAVI patients.

3.
Cardiology ; 148(6): 547-555, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37586346

RESUMEN

INTRODUCTION: The management of patients with severe aortic stenosis may differ according to patients' age. The aim of this analysis was to describe patterns of aortic valve replacement (AVR) use in European countries stratified by age. METHODS: Procedure volume data for AVR, including surgical aortic valve replacement (sAVR) and transcatheter aortic valve implantation (TAVI), for the years 2015-2020 were obtained from national databases for twelve European countries (Austria, the Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland). Procedure volumes were reported by patient age (<50 years, 5-year age groups between 50 and 85 years, and ≥85 years). Patients per million (PPM) population undergoing AVR each year were calculated using population estimates from Eurostat. RESULTS: AVR PPM varied widely between countries, from 508 PPM in Germany to 174 PPM in Poland in 2020. TAVI rates ranged from 61% in Switzerland and Finland to 25% in Poland. AVR PPM increased with age to a peak at 80-84 years, after which it decreased again. AVR procedures increased from 2015 to 2019 at an average annual rate of 3.9%. AVR increased more substantially in people aged ≥80 years than in younger age groups; these older age groups accounted for 30% of all AVR procedures in 2015 and 35% in 2019. TAVI accounted for an increasing proportion of all AVR procedures as patient age increased; an overall average of 96% of males and 98% of females aged ≥85 years received TAVI as the treatment modality, although adoption of TAVI differed between countries. CONCLUSIONS: There is considerable variation in the rates of AVR use and the adoption of TAVI versus sAVR between European countries. The use of TAVI has increased in recent years, particularly for older patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Masculino , Humanos , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Europa (Continente) , Implantación de Prótesis de Válvulas Cardíacas/métodos
4.
Heart Vessels ; 38(8): 1009-1018, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37067577

RESUMEN

Randomized trials suggest benefits for fractional flow reserve (FFR)-guided vs. angiography-guided treatment strategies in well-defined and selected patient cohorts with acute coronary syndromes (ACS). The long-term prognostic value of FFR measurement in unselected all-comer ACS patients, however, remains unknown. This subanalysis of the Fractional FLOw Reserve In cardiovascular DiseAses (FLORIDA) study sought to investigate the long-term effects of FFR in the management of lesions in patients with acute coronary syndrome (ACS). FLORIDA was an observational all-comer cohort study performed in Germany, that was population-based and unselected. Patients enrolled into the anonymized InGef Research Database presenting with ACS and undergoing coronary angiography between January 2014 and December 2015 were included in the analysis. Patients were stratified into either the FFR-guided or the angiography-guided treatment arm, based on the treatment received. A matched cohort study design was used. The primary endpoint was all-cause mortality. The secondary endpoint was major adverse cardiovascular events (MACE), a composite of death, non-fatal myocardial infarction (MI), and repeat revascularization. Follow-up time was 3 years. Rates of 3-year mortality were 10.2 and 14.0% in the FFR-guided and the angiography-guided treatment arms (p = 0.04), corresponding to a 27% relative risk reduction for FFR in ACS patients. Rates of MACE were similar in both arms (47.7 vs. 51.5%, p = 0.14), including similar rates of non-fatal MI (27.7 vs. 25.4%, p = 0.47) and revascularization (9.9 vs. 12.1%, p = 0.17). In this large, all-comer observational study of ACS patients, FFR-guided revascularization was associated with a lower mortality at 3 years. This finding encourages the routine use of FFR to guide lesion revascularization in patients presenting with ACS.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Pronóstico , Estudios de Cohortes , Florida , Angiografía Coronaria/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/terapia , Resultado del Tratamiento
5.
Thorac Cardiovasc Surg ; 71(2): 94-100, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-34521136

RESUMEN

OBJECTIVE: This study aimed to assess short-term outcomes of patients with failed aortic valve bioprosthesis undergoing valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) or redo surgical aortic valve replacement (rSAVR). METHODS: Between 2009 and 2019, 90 patients who underwent ViV-TAVR (n = 73) or rSAVR (n = 17) due to failed aortic valve bioprosthesis fulfilled the inclusion criteria. Groups were compared regarding clinical end points, including in-hospital all-cause mortality. Patients with endocarditis and in a need of combined cardiac surgery were excluded from the study. RESULTS: ViV-TAVR patients were older (78.0 ± 7.4 vs. 62.1 ± 16.2 years, p = 0.012) and showed a higher prevalence of baseline comorbidities such as atrial fibrillation, diabetes mellitus, hyperlipidemia, and arterial hypertension. In-hospital all-cause mortality was higher for rSAVR than in the ViV-TAVR group (17.6 vs. 0%, p < 0.001), whereas intensive care unit stay was more often complicated by blood transfusions for rSAVR patients without differences in cerebrovascular events. The paravalvular leak was detected in 52.1% ViV-TAVR patients compared with 0% among rSAVR patients (p < 0.001). CONCLUSION: ViV-TAVR can be a safe and feasible alternative treatment option in patients with degenerated aortic valve bioprosthesis. The choice of treatment should include the patient's individual characteristics considering ViV-TAVR as a standard of care.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Riesgo , Reoperación , Falla de Prótesis , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos
6.
Eur Heart J ; 43(25): 2388-2403, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35165695

RESUMEN

AIMS: Current troponin cut-offs suggested for the post-operative workup of patients following coronary artery bypass graft (CABG) surgery are based on studies using non-high-sensitive troponin assays or are arbitrarily chosen. We aimed to identify an optimal cut-off and timing for a proprietary high-sensitivity cardiac troponin I (hs-cTnI) assay to facilitate post-operative clinical decision-making. METHODS AND RESULTS: We performed a retrospective analysis of all patients undergoing elective isolated CABG at our centre between January 2013 and May 2019. Of 4684 consecutive patients, 161 patients (3.48%) underwent invasive coronary angiography after surgery, of whom 86 patients (53.4%) underwent repeat revascularization. We found an optimal cut-off value for peak hs-cTnI of >13 000 ng/L [>500× the upper reference limit (URL)] to be significantly associated with repeat revascularization within 48 h after surgery, which was internally validated through random repeated sampling with 1000 iterations. The same cut-off also predicted 30-day major adverse cardiovascular events and all-cause mortality after a median follow-up of 3.1 years, which was validated in an external cohort. A decision tree analysis of serial hs-cTnI measurements showed no added benefit of hs-cTnI measurements in patients with electrocardiographic or echocardiographic abnormalities or haemodynamic instability. Likewise, early post-operative hs-cTnI elevations had a low yield for clinical decision-making and only later elevations (at 12-16 h post-operatively) using a threshold of 8000 ng/L (307× URL) were significantly associated with repeat revascularization with an area under the curve of 0.92 (95% confidence interval 0.88-0.95). CONCLUSION: Our data suggest that for hs-cTnI, higher cut-offs than currently recommended should be used in the post-operative management of patients following CABG.


Asunto(s)
Puente de Arteria Coronaria , Infarto del Miocardio , Troponina I , Biomarcadores/sangre , Toma de Decisiones Clínicas , Humanos , Cuidados Posoperatorios , Estudios Retrospectivos , Troponina I/sangre
7.
Catheter Cardiovasc Interv ; 100(7): 1323-1330, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36259741

RESUMEN

OBJECTIVES: This study evaluates the impact of transcatheter tricuspid valve interventions (TTVI) on cognitive function (CF), quality of life (QOL), and exercise capacity in late-stage heart failure with preserved ejection fraction (HFpEF) and relevant tricuspid regurgitation (TR). BACKGROUND: Reduced cardiac output (CO) critically affects CF. Severe TR aggravates CO reduction in HFpEF, while TTVI has been demonstrated to re-establish CO to a significant extent. The effect of TTVI on CF of HFpEF patients has so far not been investigated. METHODS: Assessment of CF was performed using the standardized Montreal Cognitive Assessment test in 34 symptomatic HFpEF patients with at least severe TR before and 3 months after TTVI alongside echocardiographic examinations and assessment of exercise capacity and QOL. RESULTS: Median age of the patients was 81.0 [78.8; 83.0] years and 50.0% were female. CF was impaired in 67.6% of the patients. TR ≤ moderate was achieved in 94.1% of the cases. Overall CF improved significantly (from 20.6 ± 3.9 to 23.0 ± 4.4; p = 0.001). Particularly, significant improvements were identified in the executive function (p < 0.001) and memory (p = 0.008). In addition, linear regression analysis demonstrated a significant collinearity of improvement between executive function as well as memory and increased CO (ρ = 0.695; p < 0.001 and ρ = 0.628; p < 0.001, respectively). The walked distance and QOL also improved significantly 3 months after TTVI. CONCLUSION: Cognitive impairment is highly prevalent in HFpEF patients with severe TR. TTVI results in an improved CF, especially with regard to executive function and memory. These improvements also correlate with more efficient hemodynamics reflected by increased CO.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Masculino , Válvula Tricúspide , Calidad de Vida , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Volumen Sistólico , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Factores de Tiempo , Cognición , Índice de Severidad de la Enfermedad
8.
Pacing Clin Electrophysiol ; 45(1): 149-153, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34564879

RESUMEN

Limited data exists about the effectiveness of the coronary sinus reducer (CSR) device in patients with angina pectoris and atrial fibrillation (AF). This case demonstrates beneficial effects of AF ablation in a patient with CSR. We report four major findings: Rhythm control has a relevant effect on angina pectoris symptoms in patients with coronary artery disease and AF. In these patients, AF ablation should be considered at an early stage. Patients with persistent angina pectoris and CSR may require sinus rhythm for an optimal effect of the device. Selected coronary sinus (CS) interventions can still be performed through the mesh of the CSR device.


Asunto(s)
Angina de Pecho/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Seno Coronario/cirugía , Stents , Anciano , Electrocardiografía , Humanos , Masculino
9.
Catheter Cardiovasc Interv ; 97(5): 876-884, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32886851

RESUMEN

OBJECTIVES: To investigate 4-year, post-transcatheter aortic valve implantation (TAVI) survival and predictors of survival by sex, in a real-world cohort that underwent transfemoral TAVI with SAPIEN 3 transcatheter heart valve. BACKGROUND: Previous TAVI investigations of first-generation devices demonstrated an early- to mid-term survival advantage in women compared with men. METHODS: SOURCE 3 (SAPIEN 3 Aortic Bioprosthesis European Outcome) is a post-approval, multicentre, observational registry. Patients (N = 1,694, 49.2% women, age 81.7 ± 6.7 years) with severe aortic stenosis and high surgical risk (logistic EuroSCORE 17.8%) underwent TAVI between 2014 and 2015. Kaplan-Meier event estimates were used to determine mortality by sex. Predictors of overall mortality were identified using a cox multivariate proportional hazard model. RESULTS: At 4 years, women had lower all-cause mortality than men (36.0 vs 39.7%; p = .0911; HR: 0.87 [95% CI: 0.75-1.02]). No difference was observed for cardiac mortality between women 24.2% and men 24.7% (p = .76; HR: 0.97 [95% CI: 0.79-1.19]). When adjusted for baseline characteristics (age, height, weight, NYHA functional class, renal insufficiency, EuroScore, and tricuspid regurgitation), sex had no impact on mortality. CONCLUSIONS: In this large, real-world cohort, all-cause mortality trended lower in women than men at 4 years post TAVI; however, several baseline factors, but not sex, were predictors of mortality. No difference between sexes was observed for cardiovascular mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Thorac Cardiovasc Surg ; 69(5): 420-427, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33761569

RESUMEN

BACKGROUND: Rapid deployment aortic valve replacement (RDAVR) and transcatheter aortic valve implantation (TAVI) have emerged as increasingly used alternatives to conventional aortic valve replacement to treat patients at higher surgical risk. Therefore, in this single-center study, we retrospectively compared clinical outcomes and hemodynamic performance of two self-expanding biological prostheses, the sutureless and rapid deployment valve (RDV) Perceval-S (PER) and the transcatheter heart valve (THV) ACURATE neo/TF (NEO) in a 1:1 propensity-score-matching (PSM) patient cohort. METHODS: A total of 332 consecutive patients with symptomatic aortic valve stenosis underwent either singular RDAVR with PER (119) or TAVI with NEO (213) at our institutions between 2012 and 2017. To compare the unequal patient groups, a 1:1 PSM for preoperative data and comorbidities was conducted. Afterward, 59 patient pairs were compared with regard to relevant hemodynamic parameter, relevant paravalvular leak (PVL), permanent postoperative pacemaker (PPM) implantation rate, and clinical postoperative outcomes. RESULTS: Postoperative clinical short-term outcomes presented with slightly higher rates for 30-day all-cause mortality (PER = 5.1% vs. NEO = 1.7%, p = 0.619) and major adverse cardiocerebral event in PER due to cerebrovascular events (transient ischemic attack [TIA]-PER = 3.4% vs. TIA-NEO = 1.7%, p = 0.496 and Stroke-PER = 1.7% vs. Stroke-NEO = 0.0%, p = 1). Moreover, we show comparable PPM rates (PER = 10.2% vs. NEO = 8.5%, p = 0.752). However, higher numbers of PVL (mild-PER = 0.0% vs. NEO = 55.9%, p = 0.001; moderate or higher-PER = 0.0% vs. NEO = 6.8%, p = 0.119) after TAVI with NEO were observed. CONCLUSION: Both self-expanding bioprostheses, the RDV-PER and THV-NEO provide a feasible option in elderly and patients with elevated perioperative risk. However, the discussed PER collective showed more postoperative short-term complications with regard to 30-day all-cause mortality and cerebrovascular events, whereas the NEO showed higher rates of PVL.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Herz ; 46(Suppl 1): 15-23, 2021 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-31938804

RESUMEN

The regulation of coronary flow is mainly located in the resistance vessels of the microcirculation, so that the functional relevance of a coronary stenosis arises from the interaction between the epicardial stenosis and the downstream microcirculation. These complex interactions are precisely detectable by physiological measurements, such as the instantaneous wave-free ratio (iwFR) or the fractional flow reserve (FFR). In contrast, the purely visual assessment of the coronary anatomy could lead to misinterpretation and possibly to incorrect revascularization decisions. Consequently, in the current guidelines on myocardial revascularization of the European Society of Cardiology (ESC) the measurement of iwFR and FFR has a class IA indication in intermediate stenoses with unclear hemodynamic relevance. Despite this clear recommendation, physiological measurements are not yet regularly used in the clinical routine. Besides the purely hemodynamic assessment, novel methods such as co-registration and coronary mapping can be used for virtual planning of percutaneous coronary interventions, especially in vessels with diffuse lesions and serial stenoses. Furthermore, invasive flow measurements are also helpful for risk stratification between conservative and interventional treatment of patients with acute coronary syndrome, where additional factors of flow limitation, such as coronary spasm, thrombus and acute disturbance of the microcirculation play an important role.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Cateterismo Cardíaco , Catéteres , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Laboratorios , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
12.
Heart Vessels ; 35(12): 1735-1745, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32591894

RESUMEN

Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%; p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes.Clinical Trial: NCT03497611.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Estimulación Cardíaca Artificial , Bloqueo Cardíaco/terapia , Frecuencia Cardíaca , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Europa (Continente) , Femenino , Bloqueo Cardíaco/diagnóstico , Bloqueo Cardíaco/etiología , Bloqueo Cardíaco/fisiopatología , Humanos , Masculino , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Thorac Cardiovasc Surg ; 68(2): 158-161, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-29490387

RESUMEN

BACKGROUND: Advanced visualization software tools have been used in clinics to improve the safety and accuracy of transcatheter procedure. Imaging techniques have greatly evolved during the era of transcatheter aortic valve implantation (TAVI). In a retrospective analysis, we investigated the feasibility of augmented fluoroscopy for iliofemoral access using a novel "Vascular Outlining" roadmapping technology. METHODS: The Vascular Outlining prototype device (Philips Healthcare) application was used with iliofemoral angiography of 10 patients undergoing transfemoral TAVI. The software processes any conventional angiographic sequences, extracting the static outline of vessels and projecting the two-dimensional vessel margins as a roadmap on live fluoroscopy. Post-processed results were clinically assessed to determine whether the technical performance of the tool is sufficient. RESULTS: Augmented imaging was possible in all investigated angiography sequences. The analysis of software-generated images showed accurate projection of the two-dimensional outline of the iliofemoral vessels as an overlay on the live fluoroscopy image in most cases. Overlay inaccuracy was only observed in cases with low contrast or patient movement. CONCLUSION: In static and contrasted angiography sequences, "Vascular Outlining" showed accurate image overlay. We identified that the quality of the vascular outline is dependent on the opacification of the contrast injection and the stability of the patient on the table. With further development. this application might increase the accuracy of femoral puncture and reduce the incidence of vascular complications. Clinical trials are needed to confirm these hypotheses.


Asunto(s)
Angiografía , Cateterismo Periférico , Arteria Femoral/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Fluoroscopía , Humanos , Valor Predictivo de las Pruebas , Punciones , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter
14.
Eur Heart J ; 40(38): 3156-3165, 2019 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-31230081

RESUMEN

AIMS: Peri-procedural transcatheter valve embolization and migration (TVEM) is a rare but potentially devastating complication of transcatheter aortic valve implantation (TAVI). We sought to assess the incidence, causes, and outcome of TVEM in a large multicentre cohort. METHODS AND RESULTS: We recorded cases of peri-procedural TVEM in patients undergoing TAVI between January 2010 and December 2017 from 26 international sites. Peri-procedural TVEM occurred in 273/29 636 (0.92%) TAVI cases (age 80.8 ± 7.3 years; 53.8% female), of which 217 were to the ascending aorta and 56 to the left ventricle. The use of self-expanding or first-generation prostheses and presence of a bicuspid aortic valve were independent predictors of TVEM. Bail-out measures included repositioning attempts using snares or miscellaneous tools (41.0%), multiple valve implantations (83.2%), and conversion to surgery (19.0%). Using 1:4-propensity matching, we identified a cohort of 235 patients with TVEM (TVEMPS) and 932 patients without TVEM (non-TVEMPS). In the matched cohort, all-cause mortality was higher in TVEMPS than in non-TVEMPS at 30 days (18.6% vs. 4.9%; P < 0.001) and after 1 year (30.5% vs. 16.6%; P < 0.001). Major stroke was more frequent in TVEMPS at 30 days (10.6% vs. 2.8%; P < 0.001), but not at 1 year (4.6% vs. 1.9%; P = 0.17). The need for emergent cardiopulmonary support, major stroke at 30 days, and acute kidney injury Stages 2 and 3 increased the risk of 1-year mortality, whereas a better renal function at baseline was protective. CONCLUSION: Transcatheter valve embolization and migration occurred in approximately 1% and was associated with increased morbidity and mortality.


Asunto(s)
Embolia , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Embolia/epidemiología , Embolia/etiología , Embolia/mortalidad , Femenino , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Falla de Prótesis/efectos adversos , Falla de Prótesis/etiología , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 94(3): 469-478, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30866154

RESUMEN

AIMS: We aimed to assess whether the level of aortic root calcification is associated with BAV performance/omission during transcatheter aortic valve implantation (TAVI), and to explore related outcomes. METHODS AND RESULTS: EASE-IT TF was a prospective, observational, multicenter registry of patients undergoing TF-TAVI with the Edwards SAPIEN 3, with or without BAV predilation. Valvular calcification was quantified from pre-procedural multi-slice computed tomography images and compared between BAV and no BAV patients. Data for 178 patients (55 BAV; 123 no BAV) were analyzed. There were no significant differences between groups in terms of regional/leaflet sector calcification volumes, maximum asymmetry between the different leaflet sectors, or total calcification scores. Overall, a greater-than-average leaflet calcification volume was independently predictive of ≥mild PVL (OR: 5.116; 95% CI: 1.042-38.35) and the need for post-dilation (OR: 3.592; 95% CI: 1.173-12.14). The latter effect was abated in patients with BAV (OR: 1.837; 95% CI: 0.223-18.00) and intensified in those without BAV (OR: 5.575; 95% CI: 1.114-38.74). No other BAV-dependent effects of calcification on outcomes were observed. CONCLUSIONS: In the majority of transfemoral valve implantations, calcification does not appear to be the main driving factor in the decision to perform/omit BAV. Predilation may be valuable for reducing post-dilation requirements in patients only with a greater degree of leaflet calcification.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Calcinosis/cirugía , Cateterismo Periférico , Arteria Femoral , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Cateterismo Periférico/efectos adversos , Toma de Decisiones Clínicas , Femenino , Humanos , Masculino , Estudios Prospectivos , Punciones , Recuperación de la Función , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Circ Res ; 121(1): 56-70, 2017 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-28404615

RESUMEN

RATIONALE: Ventricular arrhythmias remain the leading cause of death in patients suffering myocardial ischemia. Myeloperoxidase, a heme enzyme released by polymorphonuclear neutrophils, accumulates within ischemic myocardium and has been linked to adverse left ventricular remodeling. OBJECTIVE: To reveal the role of myeloperoxidase for the development of ventricular arrhythmias. METHODS AND RESULTS: In different murine models of myocardial ischemia, myeloperoxidase deficiency profoundly decreased vulnerability for ventricular tachycardia on programmed right ventricular and burst stimulation and spontaneously as assessed by ECG telemetry after isoproterenol injection. Experiments using CD11b/CD18 integrin-deficient (CD11b-/-) mice and intravenous myeloperoxidase infusion revealed that neutrophil infiltration is a prerequisite for myocardial myeloperoxidase accumulation. Ventricles from myeloperoxidase-deficient (Mpo-/-) mice showed less pronounced slowing and decreased heterogeneity of electric conduction in the peri-infarct zone than wild-type mice. Expression of the redox-sensitive gap junctional protein Cx43 (Connexin 43) was reduced in the peri-infarct area of wild-type compared with Mpo-/- mice. In isolated wild-type cardiomyocytes, Cx43 protein content decreased on myeloperoxidase/H2O2 incubation. Mapping of induced pluripotent stem cell-derived cardiomyocyte networks and in vivo investigations linked Cx43 breakdown to myeloperoxidase-dependent activation of matrix metalloproteinase 7. Moreover, Mpo-/- mice showed decreased ventricular postischemic fibrosis reflecting reduced accumulation of myofibroblasts. Ex vivo, myeloperoxidase was demonstrated to induce fibroblast-to-myofibroblast transdifferentiation by activation of p38 mitogen-activated protein kinases resulting in upregulated collagen generation. In support of our experimental findings, baseline myeloperoxidase plasma levels were independently associated with a history of ventricular arrhythmias, sudden cardiac death, or implantable cardioverter-defibrillator implantation in a cohort of 2622 stable patients with an ejection fraction >35% undergoing elective diagnostic cardiac evaluation. CONCLUSIONS: Myeloperoxidase emerges as a crucial mediator of postischemic myocardial remodeling and may evolve as a novel pharmacological target for secondary disease prevention after myocardial ischemia.


Asunto(s)
Arritmias Cardíacas/metabolismo , Isquemia Miocárdica/metabolismo , Miocitos Cardíacos/metabolismo , Peroxidasa/deficiencia , Remodelación Ventricular/fisiología , Animales , Arritmias Cardíacas/patología , Células Cultivadas , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Isquemia Miocárdica/patología , Miocitos Cardíacos/patología , Técnicas de Cultivo de Órganos
17.
BMC Cardiovasc Disord ; 19(1): 172, 2019 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-31324150

RESUMEN

BACKGROUND: To evaluate the outcomes of transcatheter aortic valve implantation (TAVI) without balloon aortic valvuloplasty (BAV) in a real-world setting through a patient-level meta-analysis. METHODS: The meta-analysis included patients of three European multicenter, prospective, observational registry studies that compared outcomes after Edwards SAPIEN 3 or XT TAVI with (n = 339) or without (n = 355) BAV. Unadjusted and adjusted pooled odds ratios (with 95% confidence intervals) were calculated for procedural and 30-day outcomes. RESULTS: Median procedural time was shorter in the non-BAV group than in the BAV group (73 versus 93 min, p = 0.001), as was median fluoroscopy time (7 versus 11 min, p = 0.001). Post-delivery balloon dilation (15.5% versus 22.4%, p = 0.02) and catecholamine use (9.0% vs. 17.9%; p = 0.016) was required less often in the non-BAV group than in the BAV group with the difference becoming insignificant after multiple adjustment. There was a reduced risk for periprocedural atrioventricular block during the intervention (1.4% versus 4.1%, p = 0.035) which was non-significant after adjustment. The rate of moderate/severe paravalvular regurgitation post-TAVI was 0.6% in the no-BAV group versus 2.7% in the BAV group. There were no between-group differences in the risk of death, stroke or other adverse clinical outcomes at day 30. CONCLUSIONS: This patient-level meta-analysis of real-world data indicates that TAVI performed without BAV is advantageous as it has an adequate device success rate, reduced procedure time and no adverse effects on short-term clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Europa (Continente) , Femenino , Prótesis Valvulares Cardíacas , Hemodinámica , Humanos , Masculino , Estudios Multicéntricos como Asunto , Estudios Observacionales como Asunto , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
18.
Thorac Cardiovasc Surg ; 67(4): 236-242, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29172210

RESUMEN

BACKGROUND: The latest generation of balloon-expandable valve, the Edwards Sapien 3 valve (S3V), was designed to reduce paravalvular regurgitation (PVR). We retrospectively compared S3V with Edwards Sapien XT valve (SXTV) with regard to postprocedural transvalvular pressure gradients (PGs). METHODS: Analysis of 152 patients receiving SXTV and 125 patients receiving S3V between February 2009 and April 2015 was performed. Transvalvular PGs and the incidence and extent of aortic regurgitation (AR) were compared postprocedurally by echocardiography for each valve size. RESULTS: Postprocedurally, mean PGs for the 23 mm valves were 10.9 ± 5.3 versus 13.9 ± 5.1 (p = 0.017), whereas maximum PGs were 19.9 ± 8.3 versus 26.1 ± 10.4 mm Hg (p = 0.005) in SXTV and S3V patients, respectively. For the 26 mm valves, gradients were also significantly higher in S3V patients (mean PG: 11.6 ± 4.9 vs. 9.2 ± 4.2 [p = 0.004]; maximum PG: 23.0 ± 10.1 vs. 17.2 ± 7.4 mm Hg [p < 0.001]). Analysis revealed no significant differences in postprocedural transvalvular PGs for 29 mm valves (mean PG of 9.3 ± 3.9 and 11.2 ± 4.3 mm Hg [p = ns] and maximum PG of 17.5 ± 7.2 vs. 20.9 ± 6.8 mm Hg [p = ns]) between SXTV and S3V groups, respectively. With respect to PVR, the incidence of AR was significantly lower in S3V group (p = 0.001). CONCLUSION: S3V shows lower incidence of PVR; however, it is associated with significantly higher postprocedural transvalvular PGs for 23 and 26 mm valve sizes. These data might contribute to the scientific discussion, especially with respect to prosthesis selection in individual patients with small annular dimension.


Asunto(s)
Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Alemania/epidemiología , Humanos , Incidencia , Masculino , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Eur Heart J ; 39(8): 676-684, 2018 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-29253177

RESUMEN

Aims: Life-threatening complications occur during transcatheter aortic valve implantation (TAVI) which can require emergent cardiac surgery (ECS). Risks and outcomes of patients needing ECS during or immediately after TAVI are still unclear. Methods and results: Incidence, risk factors, management, and outcomes of patients requiring ECS during transfemoral (TF)-TAVI were analysed from a contemporary real-world multicentre registry. Between 2013 and 2016, 27 760 patients underwent TF-TAVI in 79 centres. Of these, 212 (0.76%) patients required ECS (age 82.4 ± 6.3 years, 67.5% females, logistic EuroSCORE: 17.1%, STS-score 5.8%). The risk of ECS declined from 2013 (1.07%) to 2014 (0.70%) but remained stable since. Annual TF-TAVI numbers have more than doubled from 2013 to 2016. Leading causes for ECS were left ventricular perforation by the guidewire (28.3%) and annular rupture (21.2%). Immediate procedural mortality (<72 h) of TF-TAVI patients requiring ECS was 34.6%. Overall in-hospital mortality was 46.0%, and highest in case of annular rupture (62%). Independent predictors of in-hospital mortality following ECS were age > 85 years [odds ratio (OR) 1.87, 95% confidence interval (95% CI) (1.02-3.45), P = 0.044], annular rupture [OR 1.96, 95% CI (0.94-4.10), P = 0.060], and immediate ECS [OR 3.12, 95% CI (1.07-9.11), P = 0.037]. One year of survival of the 114 patients surviving the in-hospital period was only 40.4%. Conclusion: Between 2014 and 2016, the need for ECS remained stable around 0.7%. Left ventricular guidewire perforation and annular rupture were the most frequent causes, accounting for almost half of ECS cases. Half of the patients could be salvaged by ECS-nevertheless, 1 year of all-cause mortality was high even in those ECS patients surviving the in-hospital period.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Mortalidad Hospitalaria/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Procedimientos Quirúrgicos Cardíacos/tendencias , Tratamiento de Urgencia/tendencias , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Masculino , Sistema de Registros , Medición de Riesgo
20.
Catheter Cardiovasc Interv ; 92(6): 1021-1027, 2018 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-29508518

RESUMEN

OBJECTIVES: To date, experience with bioresorbable scaffolds (BRS) that elute agents other than everolimus is limited. Thus, a post-marketing clinical follow-up study was conducted to evaluate the continued safety and effectiveness of the DESolve® NOVOLIMUS™ Eluting BRS as treatment for patients with stable coronary artery disease. BACKGROUND: The DESolve BRS combines a poly-l-lactide-based backbone with a biodegradable polylactide-based polymer and Novolimus, a macrocyclic lactone mTOR inhibitor. METHODS: One hundred and two patients (mean age 62 years, 77.5% male) were enrolled at 10 European sites. Comparison of baseline and post-procedural angiographic assessment was performed, and a device-oriented composite endpoint (comprising cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) and rate of scaffold thrombosis at 12 months were examined. RESULTS: The device was successfully delivered and deployed in 98.2% (107/109) of the lesions, with two failures to cross the lesion. A total of 100 patients (109 lesions) were treated with a DESolve BRS. Post-procedural angiographic assessment indicated an in-scaffold acute gain of 1.54 ± 0.44 mm, with a reduction in % diameter stenosis from 61.00 ± 11.29 to 12.69 ± 0.44. At 12 months, the device-oriented composite endpoint had occurred in 3.0% (3/100) of patients, with 1.0% (1/100) experiencing scaffold thrombosis and myocardial infarction and 3.0% (3/100) undergoing target lesion revascularization. There were no cardiac deaths. CONCLUSIONS: Results through 12 months indicate that the DESolve BRS is a safe and effective treatment for coronary lesions, though larger, long-term prospective studies are needed.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Macrólidos/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Alemania , Humanos , Italia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA