Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Artif Organs ; 48(6): 577-585, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38577853

RESUMEN

PURPOSE: LVAD outflow graft stenosis continues to remain prevalent with a high complication rate. We sought to pool the existing evidence on indications, utilization patterns, and outcomes of transcatheter interventions for outflow graft stenosis in the HeartMate 3 LVAD. METHODS: An electronic search was performed to identify all studies in the English literature reporting on HeartMate 3 LVAD outflow graft stenting. Patient-level data were extracted for analysis. RESULTS: Thirteen published reports and one unpublished case comprising a total of 28 patients were included. Median patient age was 68.5 years [Interquartile range: 58, 71] and 25.9% (7/27) were female. Dyspnea [60.7% (17/28)] was the most common presenting symptom. Low flow alarms were present in 60% (15/25) of patients. Findings included external compression [35.7% (10/28)], graft twist [21.4% (6/28)], graft twist and external compression [14.3% (4.28)], intraluminal thrombus [10.7% (3/28)], graft twist and intraluminal thrombus [3.6% (1/28)], and pseudoaneurysm of outflow graft [3.6% (1/28)]. Median time from LVAD implantation to stenting was 2.1 years [1.4, 3]. Immediate flow normalization after stenting was observed in 85.7% (24/28). The 30-day mortality was 12% (3/25). Overall mortality was 12% (3/25) at a median follow-up of 3.9 months [1, 17]. CONCLUSION: Outflow graft stenting in the HeartMate 3 LVAD appears to be a reasonable treatment option for outflow graft stenosis, with low overall rates of complications and mortality. Further refinement of indications and approaches may improve outcomes.


Asunto(s)
Corazón Auxiliar , Stents , Humanos , Corazón Auxiliar/efectos adversos , Stents/efectos adversos , Resultado del Tratamiento , Insuficiencia Cardíaca/cirugía , Femenino , Persona de Mediana Edad , Anciano , Masculino
2.
Artif Organs ; 47(6): 934-942, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36691820

RESUMEN

BACKGROUND: Microaxial circulatory support devices have been used to support patients treated with percutaneous coronary intervention (PCI) for acute myocardial infarction complicated by cardiogenic shock (AMICS). The purpose of this systematic review and meta-analysis was to pool and analyze the existing evidence on the baseline characteristics, periprocedural data, and outcomes of microaxial support before and after PCI in AMICS. METHODS: An electronic database search was performed to identify all cohort studies on Impella and PCI for cardiogenic shock in the English language. A total of five articles comprising 543 patients were included. These patients received microaxial support either before (pre-PCI) or after (post-PCI) undergoing PCI. Comparative analyses were done between both groups. RESULTS: The mean patient age was 66 years [95% Confidence Interval (58-74)], and 22% (89/396) of patients were female. ST-elevation myocardial infarctions (MI) comprised 64% (44-80) of MIs and 50% (44-56) of MIs involved the left anterior descending artery. The mean number of diseased vessels was 2.21 (1.62-2.80). The mean left ventricular ejection fraction was 31% (23.4-38.6). The mean arterial pressure was 66.3 mm Hg (54.1-78.5). Mean serum lactate [6.1 mmol/L (3.3-8.9)] and serum creatinine [1.4 mg/dl (1.0-1.7)] were similar between groups. 30-day mortality was lower in the pre-PCI group [41% (34%-49%)] compared to the post-PCI group [61% (42%-77%), p < 0.01]. Pooled Kaplan-Meier analysis showed better early survival in the pre-PCI group (p < 0.001). CONCLUSION: Patients presenting with AMICS were similar at baseline in both pre-PCI and post-PCI groups. Nevertheless, pre-PCI group showed better early survival compared to post-PCI group.


Asunto(s)
Corazón Auxiliar , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Femenino , Anciano , Masculino , Choque Cardiogénico/terapia , Intervención Coronaria Percutánea/efectos adversos , Volumen Sistólico , Corazón Auxiliar/efectos adversos , Función Ventricular Izquierda , Infarto del Miocardio/complicaciones , Resultado del Tratamiento
3.
Curr Opin Hematol ; 28(5): 292-300, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34261880

RESUMEN

PURPOSE OF REVIEW: Although a patent foramen ovale (PFO) is an established risk factor for cryptogenic ischemic stroke, strategies for secondary prevention remain controversial. Increasing evidence over the past decade from well designed clinical trials supports transcatheter PFO closure for selected patients whose stroke was likely attributable to the PFO. However, patient selection using imaging findings, clinical scoring systems, and in some cases, thrombophilia testing, is crucial for determining patients most likely to benefit from closure, anticoagulation, or antiplatelet therapy. RECENT FINDINGS: Recent studies have found that patients with a high Risk of Paradoxical Embolism (RoPE) score and those with a thrombophilia benefit more from closure than medical therapy (including antiplatelet or anticoagulant therapy) alone. Meta-analyses have demonstrated an increased short-term risk of atrial fibrillation in closure patients, and that residual shunt after closure predicts stroke recurrence. Last, recent data have been inconclusive as to whether patients receiving medical therapy only benefit more from anticoagulation or antiplatelet therapy, so this remains an area of controversy. SUMMARY: Transcatheter PFO closure is an evidence-based, guideline-supported therapy for secondary stroke prevention in patients with a PFO and cryptogenic stroke. However, proper patient selection is critical to achieve benefit, and recent studies have helped clarify those patients most likely to benefit from closure.


Asunto(s)
Anticoagulantes/uso terapéutico , Embolia Paradójica , Foramen Oval Permeable , Prevención Secundaria , Accidente Cerebrovascular , Embolia Paradójica/etiología , Embolia Paradójica/prevención & control , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/tratamiento farmacológico , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
5.
Catheter Cardiovasc Interv ; 90(7): 1086-1090, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28319321

RESUMEN

OBJECTIVE: The goal of this study was to demonstrate the importance of intracoronary nitroglycerin (IC NTG) administration during diagnostic coronary angiography and prior to percutaneous coronary intervention (PCI). BACKGROUND: PCI has been a mainstay treatment for patients with symptomatic coronary artery disease. While current guidelines emphasize the importance of periprocedural antithrombotic medications, they fail to mention the use of nitroglycerin prior to PCI. METHODS: Retrospective chart and angiographic review was performed to identify patients referred for PCI who had significant angiographic stenoses that resolved after administration of IC NTG. RESULTS: The study group consisted of 6 patients (3 men, 3 women) with mean age 52 ± 4years (range 46-57 years). All had anginal symptoms and significant (>70%) stenosis on diagnostic coronary angiography. None had documented ST segment elevation. The median interval between diagnostic and staged PCI procedures was 3 days. IC NTG was not administered to any of the patients at the time of diagnostic coronary angiography. In each case, repeat coronary angiography following administration of IC NTG (155 ± 46 mcg) before planned PCI demonstrated resolution of the target stenosis. PCI was deferred and all patients were successfully managed medically. CONCLUSION: Coronary artery spasm is an under-recognized cause of chest pain in patients with significant angiographic lesions. Coronary spasm should be suspected especially in younger patients (less than 60 years old) with apparent single vessel disease. IC NTG should be routinely administered during diagnostic angiography and before PCI to avert unnecessary coronary interventions. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Estenosis Coronaria/tratamiento farmacológico , Vasoespasmo Coronario/tratamiento farmacológico , Nitroglicerina/administración & dosificación , Intervención Coronaria Percutánea , Vasodilatadores/administración & dosificación , Toma de Decisiones Clínicas , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Vasoespasmo Coronario/diagnóstico por imagen , Vasoespasmo Coronario/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nitroglicerina/efectos adversos , Intervención Coronaria Percutánea/normas , Guías de Práctica Clínica como Asunto , Valor Predictivo de las Pruebas , Derivación y Consulta , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos Innecesarios , Vasodilatadores/efectos adversos
6.
Artif Organs ; 40(3): 261-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26148217

RESUMEN

Extracorporeal membrane oxygenation (ECMO) in our institution resulted in near total mortality prior to the establishment of an algorithm-based program in July 2010. We hypothesized that an algorithm-based ECMO program improves the outcome of patients with acute myocardial infarction complicated with cardiogenic shock. Between March 2003 and July 2013, 29 patients underwent emergent catheterization for acute myocardial infarction due to left main or proximal left anterior descending artery occlusion complicated with cardiogenic shock (defined as systolic blood pressure <90 mm Hg despite multiple inotropes, with or without intra-aortic balloon pump, lactic acidosis). Of 29 patients, 15 patients were treated before July 2010 (Group 1, old program), and 14 patients were treated after July 2010 (Group 2, new program). There were no significant differences in the baseline characteristics, including age, sex, coronary risk factors, and left ventricular ejection fraction between the two groups. Cardiopulmonary resuscitation prior to ECMO was performed in two cases (13%) in Group 1 and four cases (29%) in Group 2. ECMO support was performed in one case (6.7%) in Group 1 and six cases (43%) in Group 2. The 30-day survival of Group 1 versus Group 2 was 40 versus 79% (P = 0.03), and 1-year survival rate was 20 versus 56% (P = 0.01). The survival rate for patients who underwent ECMO was 0% in Group 1 versus 83% in Group 2 (P = 0.09). In Group 2, the mean duration on ECMO was 9.8 ± 5.9 days. Of the six patients who required ECMO in Group 2, 100% were successfully weaned off ECMO or were bridged to ventricular assist device implantation. Initiation of an algorithm-based ECMO program improved the outcomes in patients with acute myocardial infarction complicated by cardiogenic shock.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Choque Cardiogénico/complicaciones , Choque Cardiogénico/terapia , Anciano , Cateterismo Cardíaco/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis de Supervivencia , Resultado del Tratamiento
7.
Radiol Cardiothorac Imaging ; 6(1): e230153, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38358329

RESUMEN

Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.


Asunto(s)
Compuestos Férricos , Hierro , Microburbujas , Óxidos , Humanos , Corazón , Ventrículos Cardíacos
8.
Stroke ; 44(4): 1172-4, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23422084

RESUMEN

BACKGROUND AND PURPOSE: Benchmark trials of carotid endarterectomy often did not include elderly patients, and the results may not be easily extrapolated to the general population. Using the Carotid Artery Revascularization and Endarterectomy registry, we sought to determine real-world outcomes of carotid endarterectomy in the elderly. METHODS: This was a retrospective cohort study of patients aged >70 years. We compared outcomes stratified by age among symptomatic and asymptomatic patients. RESULTS: There were 4149 patients who underwent carotid endarterectomy; 1376 (33.1%) were symptomatic. Overall mortality rate was 0.5%. The primary outcome of in-hospital death, stroke, and myocardial infarction showed a significant trend and was highest in the age >85 years group (5.6%). Among symptomatic patients, mortality and the primary outcome were not statistically different between those aged >75 years and those aged 70 to 74 years. Among asymptomatic elderly patients, mortality rate was significantly higher in age group >75 years compared with <75 years (0.7% vs 0.0%); however, the combined outcome of stroke, death, and myocardial infarction was not statistically different. CONCLUSIONS: Elderly patients >85 years of age were at increased risk for death or perioperative complications of stroke, death, and myocardial infarction compared with those who were relatively younger. More elderly patients underwent carotid endarterectomy for asymptomatic carotid stenosis and had higher mortality than the younger counterparts, underlining need for caution in subjecting them to the procedure.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Endarterectomía Carotidea/métodos , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/mortalidad , Estenosis Carotídea/mortalidad , Estenosis Carotídea/patología , Estudios de Cohortes , Femenino , Humanos , Masculino , Infarto del Miocardio/patología , Evaluación de Resultado en la Atención de Salud , Sistema de Registros , Estudios Retrospectivos , Riesgo , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/terapia , Resultado del Tratamiento , Estados Unidos
9.
Am J Cardiol ; 204: 122-129, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37541148

RESUMEN

An anomalous origin of the right coronary artery from the opposite sinus of Valsalva with an intramural course (R-ACAOS-IM) may cause sudden cardiac death in children and adolescents. However, the natural history and management of patients in whom this anomaly is detected later during adulthood remains uncertain. The goals of this study were to assess the impact of an R-ACAOS-IM on the clinical outcomes in an adult population and to determine if adult patients with this anomaly who do not have significant coronary artery disease (CAD) can be managed safely without surgical intervention. A database review identified patients aged >35 years with anomalous coronary arteries diagnosed by cardiac catheterization or coronary computed tomography angiography. The outcomes of patients with R-ACAOS-IM were compared with patients with anomalous left circumflex coronary arteries with retroaortic course (LCx-RA) (an anomaly not associated with ischemic events). The primary outcome was all-cause mortality. The study population consisted of 185 patients aged 59 ± 12 years. Clinical characteristics were similar in the R-ACAOS-IM (n = 88) and LCx-RA (n = 97) groups. At a follow-up of 6.6 ± 4.5 years, there was no difference in mortality (hazard ratio 0.64, 95% confidence interval 0.32 to 1.28, p = 0.20) when adjusted for gender, age, and CAD. A subgroup analysis of 88 patients with no obstructive CAD managed nonoperatively found no difference between the LCx and R-ACAOS-IM groups in mortality (hazard ratio 2.45, 95% confidence interval 0.45 to 13.40, p = 0.30). There was no significant difference between the 2 groups in the composite outcome of death, nonfatal myocardial infarction, or survived cardiac arrest. The outcome of adult patients who have anomalous R-ACAOS-IM are similar to patients who have anomalous LCx-RA with a known benign course. In conclusion, these results suggest that most patients who survive this anomaly into adulthood may be managed conservatively without intervention.


Asunto(s)
Enfermedad de la Arteria Coronaria , Anomalías de los Vasos Coronarios , Seno Aórtico , Niño , Adolescente , Humanos , Adulto , Seno Aórtico/diagnóstico por imagen , Seno Aórtico/anomalías , Estudios Retrospectivos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/complicaciones
10.
JACC Cardiovasc Imaging ; 16(2): 224-235, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36648035

RESUMEN

BACKGROUND: Noninvasive and accurate assessment of intracardiac pressures has remained an elusive goal of noninvasive cardiac imaging. OBJECTIVES: The purpose of this study was to investigate if errors in intracardiac pressures obtained noninvasively using contrast microbubbles and the subharmonic-aided pressure estimation (SHAPE) technique are <5 mm Hg. METHODS: In a nonrandomized institutional review board-approved clinical trial (NCT03243942), patients scheduled for a left-sided and/or right-sided heart catheterization procedure and providing written informed consent were included. A standard-of-care catheterization procedure was performed advancing clinically used pressure catheters into the left and/or right ventricles and/or the aorta. After pressure catheter placement, patients received an infusion of Definity microbubbles (n = 56; 2 vials diluted in 50 mL of saline; infusion rate: 4-10 mL/min) (Lantheus Medical Imaging). Then SHAPE data was acquired using a validated interface developed on a SonixTablet scanner (BK Medical Systems) synchronously with the pressure catheter data. A conversion factor (mm Hg/dB) was derived from SHAPE data and measurements with a SphygmoCor XCEL PWA device (ATCOR Medical) and was combined with SHAPE data from the left and/or the right ventricles to obtain clinically relevant systolic and diastolic ventricular pressures. RESULTS: The mean value of absolute errors for left ventricular minimum and end diastolic pressures were 2.9 ± 2.0 and 1.7 ± 1.2 mm Hg (n = 26), respectively, and for right ventricular systolic pressures was 2.2 ± 1.5 mm Hg (n = 11). Two adverse events occurred during Definity infusion; both were resolved. CONCLUSIONS: These results indicate that the SHAPE technique with Definity microbubbles is encouragingly efficacious for obtaining intracardiac pressures noninvasively and accurately. (Noninvasive, Subharmonic Intra-Cardiac Pressure Measurement; NCT03243942).


Asunto(s)
Medios de Contraste , Microburbujas , Humanos , Ultrasonografía/métodos , Valor Predictivo de las Pruebas , Cateterismo Cardíaco/efectos adversos
11.
Am J Cardiol ; 198: 101-107, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37183091

RESUMEN

Aortic stenosis (AS) and cardiac amyloidosis (CA) occur concomitantly in a significant number of patients and portend a higher risk of all-cause mortality. Previous studies have investigated outcomes in patients with concomitant CA/AS who underwent transcatheter aortic valve implantation (TAVI) versus medical therapy alone, but no evidence-based consensus regarding the ideal management of these patients has been established. Medline, Scopus, and Cochrane Central Register of Controlled Trials were systematically searched to identify relevant studies. Methodologic bias was assessed using the modified Newcastle-Ottawa scale for observational studies. A total of 4 observational studies comprising 83 patients were included. Of these, 45 patients (54%) underwent TAVI, whereas 38 (46%) were managed conservatively. Of the 3 studies that included baseline characteristics by treatment group, 30% were women. The risk of all-cause mortality was found to be significantly lower in patients who underwent TAVI than those treated with conservative medical therapy alone (odds ratio 0.24, 95% confidence interval 0.08 to 0.73). In conclusion, this meta-analysis suggests a lower risk of all-cause mortality in patients with CA with AS who underwent TAVI than those managed with medical therapy alone.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Oportunidad Relativa , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
JACC Adv ; 2(1): 100167, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38939027

RESUMEN

Background: Patients with severe aortic stenosis and cancer are often denied surgical aortic valve replacement (SAVR) due to a prohibitive risk of perioperative mortality. Objectives: The purpose of this study was to determine the safety of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and cancer. Methods: The Nationwide Inpatient Sample database (2002-2018) was used to study the outcomes of TAVI vs SAVR in patients with active or prior history of prostate, lung, colorectal, breast, and renal cancer. A propensity score-matched analysis to calculate adjusted odds ratios (aORs) for major adverse cardiovascular events (MACEs) and its components. Results: A total of 1,505,995 crude population and a subset of 345,413 noncancer and 33,565 cancer patients were selected on propensity score-matched analysis. The yearly trend showed a steep increase in the utilization of TAVI. Compared with SAVR, TAVI had a lower risk of in-hospital mortality in prostate cancer, while there was no difference among other cancer types. Patients with lung (aOR: 0.65; 95% CI: 0.43-0.97) and prostate cancer (aOR: 0.79; 95% CI: 0.66-0.96) had lower, while colorectal cancer (aOR: 1.43; 95% CI: 1.08-1.90) had higher odds of MACE with TAVI. The incidence of major bleeding was lower with TAVI (except for lung cancer), while the risk of stroke was similar (except for colorectal cancer) between TAVI and SAVR. Conclusions: TAVI in patients with prostate, breast, lung, and renal cancer appears to be a reasonable alternative to SAVR with lower or similar risks of mortality and MACE.

13.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36858660

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Mortalidad Hospitalaria , Resultado del Tratamiento , Corazón
14.
Ann Vasc Surg ; 26(1): 110-24, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21920700

RESUMEN

Despite major advances in pharmacologic and endovascular therapies, acute limb ischemia (ALI) continues to result in significant morbidity and mortality. The incidence of ALI may be as high as 13-17 cases per 100,000 people per year, with mortality rates approaching 18% in some series. This review will address the contemporary endovascular management of ALI encompassing pharmacologic and percutaneous interventional treatment strategies.


Asunto(s)
Procedimientos Endovasculares/métodos , Isquemia/cirugía , Pierna/irrigación sanguínea , Enfermedad Aguda , Humanos , Resultado del Tratamiento
15.
Ann Card Anaesth ; 25(3): 362-365, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35799570

RESUMEN

The Tempo® Temporary Pacing Lead is a temporary, transvenous, active fixation pacemaker lead used exclusively in structural heart and electrophysiology procedures since regulatory approval in 2016. We utilized the Tempo lead for four patients undergoing redo-robotic cardiac surgery in which surgical epicardial leads could not be placed. No failure-to-pace events were encountered and patients were able to participate in various levels of physical activity without limitation.


Asunto(s)
Estimulación Cardíaca Artificial , Procedimientos Quirúrgicos Cardíacos , Marcapaso Artificial , Humanos , Reoperación , Procedimientos Quirúrgicos Robotizados
16.
J Am Soc Echocardiogr ; 35(5): 460-468, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34954049

RESUMEN

BACKGROUND: Accurate expected effective orifice area (EOA) values for balloon-expandable (BE) transcatheter heart valves (THV) are crucial for preventing patient-prosthesis mismatch (PPM) and assessment of THV function. Currently published reference EOAs, however, are based on transthoracic echocardiography (TTE), which may be subject to left ventricular outflow tract diameter underestimation and/or suboptimal THV Doppler interrogation. The objective of this study was to establish reference EOA values for BE THVs on the basis of Doppler and three-dimensional (3D) transesophageal echocardiography (TEE). METHODS: Two hundred twelve intraprocedural transesophageal echocardiographic examinations performed during BE THV implantation with optimal postimplantation Doppler and 3D imaging were retrospectively reviewed. Continuity equation-derived EOAs were compared with geometric orifice areas by 3D planimetry (GOA3D). Performance indices (i.e., EOA normalized to valve size) and PPM rates were determined. TTE-based EOAs obtained within 30 days were also calculated in a subset of 170 patients. RESULTS: The average EOA for all BE THV valves (77% SAPIEN 3) was 2.3 ± 0.5 cm2, while the average EOA was 1.6 ± 0.2 cm2 for 20-mm, 2.0 ± 0.2 cm2, for 23-mm, 2.5 ± 0.3 cm2 for 26-mm, and 3.0 ± 0.3 cm2 for 29-mm THV size (P < .001). Bland-Altman analysis demonstrated very good agreement between EOA and GOA3D (bias -0.04 ± 0.15 cm2). There were strong correlations between annular area and TEE-based EOA (R = 0.84) and GOA3D (R = 0.87). The mean performance index was 47 ± 5% and was similar for all THV sizes (P = .21). EOAs based on TTE were smaller compared with those based on TEE, while the correlation with annular area (R = 0.67) and agreement with GOA3D (bias -0.26 ± 0.43 cm2) was not as strong. The overall PPM rate was 2% in the TEE cohort and 12% in the TTE cohort. CONCLUSIONS: EOAs for BE THVs based on intraprocedural Doppler and 3D TEE suggest that previously published TTE-based reference values for EOA are underestimated, while PPM rates may be overestimated. Our findings have important clinical implications for preimplantation decision-making and for the evaluation of THV hemodynamics and function during follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Ecocardiografía Transesofágica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
17.
J Orthop Res ; 40(3): 738-749, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-33913534

RESUMEN

Dupuytren's disease is a benign fibroproliferative disorder of the hand that results in disabling digital contractures that impair function and diminish the quality of life. The incidence of this disease has been correlated with chronic inflammatory states, but any direct association between inflammatory cytokines and Dupuytren's disease is not known. We hypothesized that advanced fibroproliferation is associated with increased levels of circulating inflammatory cytokines. Blood and fibrotic cord tissue were collected preoperatively from patients with severe contracture and control patients. Blood plasma concentrations of known inflammatory cytokines were evaluated using a multiplex immunoassay. Proteins from the cord tissue were analyzed by RNA sequencing and immunohistochemistry. Moreover, collagen-rich cords were analyzed using Fourier-transform infrared spectroscopy. The results indicate that patients exhibited significantly elevated circulating inflammatory cytokines, including tumor necrosis factor-α (TNF-α), interleukin (IL)-2, and IL-12p70, as compared with controls. Similarly, IL-4 and IL-13 were detected significantly more frequently in Dupuytren's disease as compared with control. RNA sequencing revealed 5311 differentially expressed genes and distinct clustering between diseased and control samples. In addition to increased expression of genes associated with fibroproliferation, we also observed upregulation of transcripts activated by inflammatory cytokines, including prolactin inducible protein and keratin intermediate filaments. IL-2, but not TNF-α, was detected in fibrotic cord tissue by immunohistochemistry. Finally, spectroscopic assays revealed a significant reduction of the collagen content and alterations of collagen cross-linking within the Dupuytren's disease tissues. In total, our results illustrate that patients with severe Dupuytren's disease exhibit substantially elevated circulating inflammatory cytokines that may drive fibroproliferation. Clinical Significance: The results from this study establish the basis for a specific cytokine profile that may be useful for diagnostic testing and therapeutic intervention in Dupuytren's disease.


Asunto(s)
Citocinas , Contractura de Dupuytren , Colágeno , Citocinas/metabolismo , Contractura de Dupuytren/etiología , Contractura de Dupuytren/patología , Fibrosis/genética , Fibrosis/metabolismo , Mano , Humanos , Inflamación/metabolismo , Factor de Necrosis Tumoral alfa
18.
Am J Hypertens ; 35(5): 397-406, 2022 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-35079778

RESUMEN

BACKGROUND: This study compared aortic pressures estimated using a SphygmoCor XCEL PWA device (ATCOR, Naperville, IL) noninvasively with aortic pressures obtained using pressure catheters during catheterization procedures and analyzed the impact of a linear-fit function on the estimated pressure values. METHODS: One hundred and thirty-six patients scheduled for cardiac catheterization procedure were enrolled in IRB approved studies. Catheterization procedures were performed according to standard-of-care to acquire aortic pressure measurements. Immediately after the catheterization procedure with the pressure catheters removed, while the patients were still in the catheterization laboratory, central aortic pressures were estimated with the SphygmoCor device (using its inbuilt transfer function). The error between measured and estimated aortic pressures was evaluated using Bland-Altman analysis (n = 93). A linear-fit was performed between the measured and estimated pressures, and using the linear equation the error measurements were repeated. A bootstrap analysis was performed to test the generalizability of the linear-fit function. In a subset of cases (n = 13), central aortic pressure values were also obtained using solid-state high-fidelity catheters (Millar, Houston, TX), and the error measurements were repeated. RESULTS: The magnitude of errors between the measured and estimated aortic pressures (mean errors >6.4 mm Hg; mean errors >8.0 mm Hg in the subset) were reduced to less than 1 mm Hg after using the linear-fit function derived in this study. CONCLUSIONS: For the population examined in this study, the SphygmoCor data must be used with the linear-fit function to obtain aortic pressures that are comparable to the measurements obtained using pressure catheters. CLINICAL TRIALS REGISTRATION: Trial Numbers NCT03243942 and NCT03245255.


Asunto(s)
Presión Arterial , Determinación de la Presión Sanguínea , Presión Sanguínea , Determinación de la Presión Sanguínea/métodos , Cateterismo Cardíaco , Catéteres , Humanos
19.
JACC Case Rep ; 4(24): 101682, 2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36438893

RESUMEN

An 80-year-old man with severe nonischemic cardiomyopathy status post left ventricular assist device (LVAD) placement 11 years prior presented for recurrent LVAD alarms from internal driveline fracture. Given his partial myocardial recovery and his preference to avoid surgical procedures, percutaneous LVAD decommissioning was performed by occlusion of the outflow graft and subsequently driveline removal. (Level of Difficulty: Advanced.).

SELECCIÓN DE REFERENCIAS