Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Biotechnol Appl Biochem ; 69(1): 376-382, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33538049

RESUMEN

Thyroid cancer appears in endocrine glands and specific to thyroid glands has been reported widely. This work was targeted to identify and quantify thyroglobulin by using antithyroglobulin antibody complexed silane surface on interdigitated electrode (IDE) sensing surface. (3-Aminopropyl)triethoxysilane linker was used to make silane-coupling with antibody and attached on the hydroxylated IDE. This electroanalytical IDE revealed the dose-dependent responses with thyroglobulin concentrations. By getting increments with the thyroglobulin concentrations, the current responses were enhanced concomitantly and the thyroglobulin detection limit was noted as 1 pM on the linear curve [y = 0.1311x + 0.5386; R² = 0.9707] with the sensitivity at lower picomolar range. Moreover, the control experiments with thyroid peroxidase and nonimmune antibody cannot yield any response of current, confirming the specific detection of thyroglobulin. This research set-up is useful to determine and quantify the thyroglobulin and diagnose thyroid cancer.


Asunto(s)
Tiroglobulina , Neoplasias de la Tiroides , Electrodos , Humanos , Silanos , Neoplasias de la Tiroides/diagnóstico
2.
Molecules ; 25(16)2020 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-32796504

RESUMEN

Graphene and its hybrids are being employed as potential materials in light-sensing devices due to their high optical and electronic properties. However, the absence of a bandgap in graphene limits the realization of devices with high performance. In this work, a boron-doped reduced graphene oxide (B-rGO) is proposed to overcome the above problems. Boron doping enhances the conductivity of graphene oxide and creates several defect sites during the reduction process, which can play a vital role in achieving high-sensing performance of light-sensing devices. Initially, the B-rGO is synthesized using a modified microwave-assisted hydrothermal method and later analyzed using standard FESEM, FTIR, XPS, Raman, and XRD techniques. The content of boron in doped rGO was found to be 6.51 at.%. The B-rGO showed a tunable optical bandgap from 2.91 to 3.05 eV in the visible spectrum with an electrical conductivity of 0.816 S/cm. The optical constants obtained from UV-Vis absorption spectra suggested an enhanced surface plasmon resonance (SPR) response for B-rGO in the theoretical study, which was further verified by experimental investigations. The B-rGO with tunable bandgap and enhanced SPR could open up the solution for future high-performance optoelectronic and sensing applications.


Asunto(s)
Técnicas Biosensibles/métodos , Boro/química , Electroquímica/métodos , Grafito/química , Resonancia por Plasmón de Superficie/métodos
3.
Molecules ; 25(18)2020 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-32937975

RESUMEN

In recent years, the field of nanophotonics has progressively developed. However, constant demand for the development of new light source still exists at the nanometric scale. Light emissions from graphene-based active materials can provide a leading platform for the development of two dimensional (2-D), flexible, thin, and robust light-emitting sources. The exceptional structure of Dirac's electrons in graphene, massless fermions, and the linear dispersion relationship with ultra-wideband plasmon and tunable surface polarities allows numerous applications in optoelectronics and plasmonics. In this article, we present a comprehensive review of recent developments in graphene-based light-emitting devices. Light emissions from graphene-based devices have been evaluated with different aspects, such as thermal emission, electroluminescence, and plasmons assisted emission. Theoretical investigations, along with experimental demonstration in the development of graphene-based light-emitting devices, have also been reviewed and discussed. Moreover, the graphene-based light-emitting devices are also addressed from the perspective of future applications, such as optical modulators, optical interconnects, and optical sensing. Finally, this review provides a comprehensive discussion on current technological issues and challenges related to the potential applications of emerging graphene-based light-emitting devices.


Asunto(s)
Grafito/química , Luz , Nanotecnología/métodos , Conductividad Eléctrica , Electroquímica , Electrodos , Electrónica , Electrones , Luminiscencia , Dispositivos Ópticos , Óptica y Fotónica , Resonancia por Plasmón de Superficie/métodos , Temperatura
5.
Micromachines (Basel) ; 13(8)2022 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-36014224

RESUMEN

In this work, a composite strain sensor is fabricated by synthesizing MXene and deposition of polypyrrole on top of the flexible electrospun PVDF nanofibers. The fabricated sensor exhibits a conductive network constructed with MXene and polypyrrole of microcracks network structure, demonstrating its strain sensing properties. The presence of these microcracks serves as mechanical weak points, which leads to sensitivity enhancement, while the electrospun fiber substrate act as a cushion for strain loading under large deformations. The as-prepared MXene@Polypyrrole PVDF sensor has a gauge factor range of 78-355 with a sensing range between 0-100%. Besides strain deformations, the sensor can operate in torsional deformation and human motion, indicating the sensor's potential as a wearable health monitoring device.

6.
Food Chem ; 390: 133105, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35580522

RESUMEN

Ochratoxin A (OTA) has harmful effects to human and animal health; therefore, sensitive and selective detection of OTA is highly demanded. Herein, an ultrasensitive electrochemical aptasensor electrode comprising electrospun MXene/polyvinylidene fluoride (Ti3C2Tx/PVDF) nanofiber composite is presented. Addition of Ti3C2Tx up to 13% effectively increased the fiber diameter and lowered the ß-phase of PVDF nanofibers, consequently lowering the charge transfer resistance. The nanofiber composite is then coated on the screen-printed carbon electrode to chemically functionalized with saline and aldehyde groups for efficient aptamer loading. The optimized aptasensor demonstrated sensitive detection of OTA over the dynamic concentration range from 1 fg mL-1 to 1 ng mL-1 with a limit of detection of 2.15 fg mL-1 and quantification limit of 6.52 fg mL-1, with high selectivity. The aptasensor could detect the OTA at femtogram per milliliter concentration in grape juice samples, demonstrating its enormous potential for OTA detection in food industry.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Nanofibras , Ocratoxinas , Técnicas Electroquímicas , Polímeros de Fluorocarbono , Límite de Detección , Ocratoxinas/análisis , Polivinilos
7.
Micromachines (Basel) ; 13(7)2022 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-35888816

RESUMEN

The optoelectronic advantages of anchoring plasmonic silver and copper particles and non-plasmonic titanium particles onto zinc oxide (ZnO) nanoflower (NF) scaffolds for the fabrication of perovskite solar cells (PSCs) are addressed in this article. The metallic particles were sputter-deposited as a function of sputtering time to vary their size on solution-grown ZnO NFs on which methylammonium lead iodide perovskite was crystallized in a controlled environment. Optical absorption measurements showed impressive improvements in the light-harvesting efficiency (LHE) of the devices using silver nanoparticles and some concentrations of copper, whereas the LHE was relatively lower in devices used titanium than in a control device without any metallic particles. Fully functional PSCs were fabricated using the plasmonic and non-plasmonic metallic film-decorated ZnO NFs. Several fold enhancements in photoconversion efficiency were achieved in the silver-containing devices compared with the control device, which was accompanied by an increase in the photocurrent density, photovoltage, and fill factor. To understand the plasmonic effects in the photoanode, the LHE, photo-current density, photovoltage, photoluminescence, incident photon-to-current conversion efficiency, and electrochemical impedance properties were thoroughly investigated. This research showcases the efficacy of the addition of plasmonic particles onto photo anodes, which leads to improved light scattering, better charge separation, and reduced electron-hole recombination rate.

8.
Nano Converg ; 7(1): 27, 2020 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-32776254

RESUMEN

Owing to the unique structural characteristics as well as outstanding physio-chemical and electrical properties, graphene enables significant enhancement with the performance of electrospun nanofibers, leading to the generation of promising applications in electrospun-mediated sensor technologies. Electrospinning is a simple, cost-effective, and versatile technique relying on electrostatic repulsion between the surface charges to continuously synthesize various scalable assemblies from a wide array of raw materials with diameters down to few nanometers. Recently, electrospun nanocomposites have emerged as promising substrates with a great potential for constructing nanoscale biosensors due to their exceptional functional characteristics such as complex pore structures, high surface area, high catalytic and electron transfer, controllable surface conformation and modification, superior electric conductivity and unique mat structure. This review comprehends graphene-based nanomaterials (GNMs) (graphene, graphene oxide (GO), reduced GO and graphene quantum dots) impregnated electrospun polymer composites for the electro-device developments, which bridges the laboratory set-up to the industry. Different techniques in the base polymers (pre-processing methods) and surface modification methods (post-processing methods) to impregnate GNMs within electrospun polymer nanofibers are critically discussed. The performance and the usage as the electrochemical biosensors for the detection of wide range analytes are further elaborated. This overview catches a great interest and inspires various new opportunities across a wide range of disciplines and designs of miniaturized point-of-care devices.

9.
Heliyon ; 6(2): e03364, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32072054

RESUMEN

The current work presents structural change and band gap tunability using hybrid organic-inorganic perovskite with the incorporation of long chain ammonium halide. Thin films of MAPbI3 with different ratio of n-butylammonium iodide (BAI) have been successfully deposited on the substrate using a single step coating technique. X-ray diffraction scans revealed the transition of the 3D structure of MAPbI3 to quasi-2D perovskite structure when BAI loading increase with a crystallite size range approximately 16 nm. This structural changeis reflected in the band gap as it increased from 1.59 eV for bulk crystal MAPbI3 to 2.13 eV for BAI and MAPbI3 ratio of 1:1. Correspondingly, photoluminescence measurement showed a blue shift in perovskite emission due to the transition of 3D to 2D layered structure perovskite. Raman spectra confirm that all fabricated films are of pristine quality and no corresponding degradation peaks of PbI2 is observed. These characteristics are important to address the single step deposition method of hybrid perovskite for perovskite solar cells application.

10.
Biosens Bioelectron ; 154: 112088, 2020 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-32056954

RESUMEN

Deoxynivalenol (DON), a cosmopolitan mycotoxin found in agricultural commodities causes serious health maladies to human and animals when accidently consumed even at a low quantity. It necessitates selective and sensitive devices to analyse DON as the conventional methods are complex and time-consuming. This study is focused on developing a selective biosensing system using iron nanoflorets graphene nickel (INFGN) as the transducer and a specific aptamer as the biorecognition element. 3D-graphene is incorporated using a low-pressure chemical vapour deposition followed by the decoration of iron nanoflorets using electrochemical deposition. INFGN enables a feasible bio-capturing due to its large surface area. The X-ray photoelectron spectroscopy analysis confirms the presence of the hydroxyl groups on the INFGN surface, which acts as the linker. Clear Fourier-transform infrared peak shifts affirm the changes with surface chemical modification and biomolecular assembly. The limit of detection attained is 2.11 pg mL-1 and displays high stability whereby it retains 30.65% of activity after 48 h. The designed INFGN demonstrates remarkable discrimination of DON against similar mycotoxins (zearalenone and ochratoxin A). Overall, the high-performance biosensor shown here is an excellent, simple and cost-effective alternative for detecting DON in food and feed samples.


Asunto(s)
Técnicas Biosensibles , Grafito/química , Hierro/química , Tricotecenos/aislamiento & purificación , Nanoestructuras/química , Níquel/química , Tricotecenos/química
11.
Int J Biol Macromol ; 116: 765-773, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29775720

RESUMEN

There are different clotting factors present in blood, carries the clotting cascade and excessive bleeding may cause a deficiency in the clotting Diagnosis of this deficiency in clotting drastically reduces the potential fatality. For enabling a sensor to detect the clotting factors, suitable probes such as antibody and aptamer have been used to capture these targets on the sensing surface. Two major clotting factors were widely studied for the diagnosis of clotting deficiency, which includes factor IX and thrombin. In addition, factor IX is considered as the substitute for heparin and the prothrombotic associated with the increased thrombin generation are taking into account their prevalence. The biosensors, surface plasmon resonance, evanescent-field-coupled waveguide-mode sensor, metal-enhanced PicoGreen fluorescence and electrochemical aptasensor were well-documented and improvements have been made for high-performance sensing. We overviewed detecting factor IX and thrombin using these biosensors, for the potential application in medical diagnosis.


Asunto(s)
Aptámeros de Nucleótidos/química , Trastornos de la Coagulación Sanguínea/sangre , Trastornos de la Coagulación Sanguínea/diagnóstico , Factor IX/metabolismo , Resonancia por Plasmón de Superficie/métodos , Trombina/metabolismo , Animales , Humanos
12.
Biosens Bioelectron ; 116: 116-122, 2018 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-29879537

RESUMEN

Tuberculosis (TB) is a chronic and infectious airborne disease which requires a diagnosing system with high sensitivity and specificity. However, the traditional gold standard method for TB detection remains unreliable with low specificity and sensitivity. Nanostructured composite materials coupled with impedimetric sensing utilised in this study offered a feasible solution. Herein, novel gold (Au) nanorods were synthesized on 3D graphene grown by chemical vapour deposition. The irregularly spaced and rippled morphology of 3D graphene provided a path for Au nanoparticles to self-assemble and form rod-like structures on the surface of the 3D graphene. The formation of Au nanorods were showcased through scanning electron microscopy which revealed the evolution of Au nanoparticle into Au islets. Eventually, it formed nanorods possessing lengths of ~ 150 nm and diameters of ~ 30 nm. The X-ray diffractogram displayed appropriate peaks suitable to defect-free and high crystalline graphene with face centered cubic Au. The strong optical interrelation between Au nanorod and 3D graphene was elucidated by Raman spectroscopy analysis. Furthermore, the anchored Au nanorods on 3D graphene nanocomposite enables feasible bio-capturing on the exposed Au surface on defect free graphene. The impedimetric sensing of DNA sequence from TB on 3D graphene/Au nanocomposite revealed a remarkable wide detection linear range from 10 fM to 0.1 µM, displays the capability of detecting femtomolar DNA concentration. Overall, the novel 3D graphene/Au nanocomposite demonstrated here offers high-performance bio-sensing and opens a new avenue for TB detection.


Asunto(s)
Técnicas Biosensibles , Oro/química , Grafito/química , Mycobacterium tuberculosis/aislamiento & purificación , Nanocompuestos/química , Nanotubos/química , Tuberculosis/diagnóstico , Técnicas Electroquímicas , Humanos , Límite de Detección , Nanopartículas del Metal/química , Conformación Molecular , Mycobacterium tuberculosis/química , Mycobacterium tuberculosis/genética , Sondas de Oligonucleótidos/química , Sondas de Oligonucleótidos/genética , Espectrometría Raman , Tuberculosis/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA