Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Gastroenterol Hepatol ; 17(10): 2016-2023.e6, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30366156

RESUMEN

BACKGROUND & AIMS: Serrated polyposis syndrome (SPS), characterized by multiple and/or large proximal serrated lesions, increases the risk of colorectal cancer. Serrated lesions often are missed during colonoscopy but panchromoendoscopy can increase their detection in an average-risk population. We performed a randomized controlled study to determine the efficacy of panchromoendoscopy in detection of polyps in patients with SPS. METHODS: Patients with SPS (n = 86 patients) underwent tandem high-definition (HD) colonoscopies from February 2015 through July 2016 at 7 centers in Spain. Patients were assigned randomly to groups that received 2 HD white-light endoscopy examinations (HD-WLE group; n = 43) or HD-WLE followed by 0.4% indigo carmine panchromoendoscopy (HD-CE group; n = 43). For each procedure, polyps detected were described, removed, and analyzed by histology. The primary outcome was additional polyp detection rate, defined as the number of polyps detected during the second inspection divided by the total number of polyps detected during the first and the second examination. RESULTS: A total of 774 polyps were detected (362 in the HD-WLE group and 412 in the HD-CE group); 54.2% were hyperplastic, 13.8% were adenomas, and 10.9% were sessile serrated polyps. There was a significantly higher additional polyp detection rate in the HD-CE group (0.39; 95% CI, 0.35-0.44) than in the HD-WLE group (0.22; 95% CI, 0.18-0.27) (P < .001). A higher additional rate of serrated lesions proximal to the sigmoid colon were detected in the second inspection with HD-CE (0.40; 95% CI, 0.33-0.47) than with HD-WLE (0.24; 95% CI, 0.19-0.31) (P = .001). Detection of adenomas and serrated lesions greater than 10 mm did not differ significantly between groups. In a multivariate logistic regression analysis, only use of HD-CE was associated independently with increased polyp detection throughout the colon. CONCLUSIONS: In a randomized controlled trial, we found that panchromoendoscopy increases detection of polyps (mostly of small serrated lesions) and should be considered the standard of care in patients with SPS. Studies are needed to determine the effects of this strategy on the incidence of advanced neoplasia during long-term follow-up evaluation. ClinicalTrials.gov no: NCT03476434.


Asunto(s)
Pólipos Adenomatosos/diagnóstico , Pólipos del Colon/diagnóstico , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Colorantes , Adenoma/diagnóstico , Adenoma/patología , Pólipos Adenomatosos/patología , Pólipos del Colon/patología , Neoplasias Colorrectales/patología , Femenino , Humanos , Carmin de Índigo , Masculino , Persona de Mediana Edad , Síndrome
2.
Med Clin (Barc) ; 134(2): 49-56, 2010 Jan 30.
Artículo en Español | MEDLINE | ID: mdl-19913837

RESUMEN

BACKGROUND AND OBJECTIVES: Before starting programs for colorectal cancer screening it is necessary to evaluate the quality of colonoscopy. Our objectives were to develop a group of quality indicators of colonoscopy easily applicable and to determine the variability of their achievement. PATIENTS AND METHODS: After reviewing the bibliography we prepared 21 potential indicators of quality that were submitted to a process of selection in which we measured their facial validity, content validity, reliability and viability of their measurement. We estimated the variability of their achievement by means of the coefficient of variability (CV) and the variability of the achievement of the standards by means of chi(2). RESULTS: Six indicators overcome the selection process: informed consent, medication administered, completed colonoscopy, complications, every polyp removed and recovered, and adenoma detection rate in patients older than 50 years. 1928 colonoscopies were included from eight endoscopy units. Every unit included the same number of colonoscopies selected by means of simple random sampling with substitution. There was an important variability in the achievement of some indicators and standards: medication administered (CV 43%, p<0.01), complications registered (CV 37%, p<0.01), every polyp removed and recovered (CV 12%, p<0.01) and adenoma detection rate in older than fifty years (CV 2%, p<0.01). CONCLUSIONS: We have validated six quality indicators for colonoscopy which are easily measurable. An important variability exists in the achievement of some indicators and standards. Our data highlight the importance of the development of continuous quality improvement programmes for colonoscopy before starting colorectal cancer screening.


Asunto(s)
Colonoscopía/normas , Indicadores de Calidad de la Atención de Salud , Humanos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA